Home

User Manual - Witura Technology Sdn Bhd

image

Contents

1. WT 1672C GSM Remote Control Switch USER MANUAL WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 INTRODUCTION The GSM Remote Control Switch is a wireless remote control on off switch that connect to the GSM cell phone network It has 1 independent relay switches these can be programmed to switch off or on whenever the GSM Remote Control Switch is called The GSM Control Switch will recognise an authorised telephone numbers calling it and action the call without answering Therefore there is no call charges incurred when calling it One Call to the SIM Card Number will switch the device OFF permanently Another Call to the SIM Card will switch the device ON permanently This system has been developed to minimize the need for over complicated programming The GSM Remote Control system supports timer function the user can set schedule to turn on off the switch For example put your pump motor on a schedule Turn off in 5 minutes turn on at 17 00 turn on 1 year later This function is important to use in the renting and leasing industry of electrical appliances heavy vehicle and rental of site equipment to turn off the machines when off hire time completed This function also important as the reminder to the owner to monitor the SIM Card expiry date User can instruct the unit to trigger the relay in the specified times and sent the SMS to the user to keep the SIM Card
2. active when expiry dates When first booting up the system you will see Green LED Lights on the side of the Enclosure and it should light up when the Network is applied to the unit The Green LED is the network Indicator and this will light up when attempting to log on to the network flash inconsistently until it locates the network A Phone Call to the SIM Card Number will now Latch the Relay permanently ON and Switch the device being Controlled On The Status of the Relay will remain as on until the unit receives a second Call to the Unit of which will now Latch the Relay Permanently off WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 Both Calls used to Latch the Relay either on or off are automatically disconnected once the relays are activated and never incur any Network Call Costs Beside calls to switch off or on the unit also can be permanently switch off and on by sending the unit a text message command Step 1 The simplest set up methods to set up Administrator number Applied the KISS Principle keep it simple stupid The GSM Remote Control Switch is easy to setup and use Insert the SIM card simply use your mobile phone call to the unit your mobile phone number will automatically register as the 1st Administrators You will receive the following SMS message from the unit Administrator 1 18617185299 your phone number 2 3 4 5 Call to the SIM Card N
3. 3 2 For example if you want to 3 Delete 3rd admin 3 3 delete admin no 2 4 Delete 4th admin 3 4 just enter 3 2 5 Delete 5th admin 3 5 2013 10 10 16 08 Thu 6 Check the relay status in ON or OFF 4 Master relay lt ON gt The unit will return Master Mode relay lt ON gt if the relay is on 2013 10 10 16 10 Thu The unit will return Master relay lt OFF gt if the relay is off 7 Check Signal Strength T5 CSQ lt 28 gt You must confirm the signal strength at site before you 2013 10 10 16 11 Thu install the unit If the signal too weak the unit will not function properly CSQ 5 12 Signal too weak system not function CSQ 13 24 Signal Good System function well CSQ 25 32 Signal Excellent System working well 8 Setting the year month day hours 12 YYYYMMDDHHMMX Time change OK YYYY 4 digit for Year minutes week 2013 10 10 16 05 Thu MM 2 digit for Month DD 2 digit for Date HH 2 digit for Hour MM 2 digit for Minutes X 1 7 Day of the Week Example set as 12 2013101016054 which means 2013 10 10 16 05 Thu If reprogram the date it will take the last as the accurate date The date have to be correct if setting 2014 2 29 or 2013 11 31 this is the incorrect date which is not occur the system will verify the date time day if correct the date have to be after year 2013 WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 o 9 S
4. Reply system ON OFF 2013 10 10 17 06 Thu Message when the system OFF N 1 means SMS Reply Message when the system ON Factory Default as SMS Reply Message when the system ON If setting to not receive SMS Reply Message when the system OFF the unit will return a message indicate successful setting for the command and it will no longer sending SMS reply until the setting of SMS Reply Message when the system ON is done When the system having the temperature alert it will automatically sending the alert message to the Admin WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 13 To receive SMS Reply Message or not to receive SMS Reply Message when the system trigger by phone call 22 N When sending command 22 0 Status switch lt OFF gt 2013 10 10 17 10 Thu When sending command 22 1 Status switch lt ON gt 2013 10 10 17 08 Thu N 1 means after make the phone call to the system it will return the SMS for the status to the caller N 0 means after make the phone call to the system it will not return the SMS for the Status to the caller Factory Default as return SMS for the status after make the phone call If you decide not to allow the system to text you for any acknowledgement after you call to the unit You can switch OFF the text message Some Customer request this function because texts reply involved call cost 14 Security
5. mode Open Mode 23 N When Setting as Security Mode 23 1 Mode switch lt ON gt 2013 10 10 17 13 Thu When Setting as Open Mode 23 0 Mode switch lt OFF gt 2013 10 10 17 13 Thu N 1 means in security mode Only allow the number in the list can text to the unit to control the system N 0 means in open mode Anybody can call to the unit to control the system Please take note that the Privacy and Security before you decide to use the Open Mode Factory Default is N 1 for Security Mode 15 SMS Text Message to Switch On Off Relay 24 N When Setting as 24 1 Master relay lt ON gt 2013 10 10 17 13 Thu When Setting as 24 0 Master relay lt OFF gt 2013 10 10 17 13 Thu N 1 means switch on the relay by SMS Message N 0 means switch off the relay by SMS Message WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 le Step 3 Installation Reset Button 3G GSM Module SIM Card Holder Antenna Timer Network LED Green Power LED RED Relay LED Connectto backup battery Pulse Counter Temperature Input Industry Power Supply input FCC CE Approved Digital Input 30A Relay Insert the SIM card to access the SIM card carrier gently push the button adjacent to it insert the SIM card and carefully close the carrier Connect the cable to terminals 220V amp N ensuring positive is connected to terminal 200V switch on the power s
6. 9 Example Connection with Freezer Wiring Diagram Model WT 1672C GSM Remote Switch NO NC COM Production Specifications Operation Voltage 12 volts DC Operating Current Maximum 500mA typically 55mA Relay Contacts 1 x Normally Open and Normally Closed Contacts maximum switching capacity 20 amps 230v ac per relay GSM Frequency MHz GSM850 GSM900 GSM1800 GSM1900 Humidity Less Than 80 RH Operating Temperature 20c to 55c Physical Size 130 x 100 x 50mm Protection IP 65 Weather Proof Casing Approvals CE FCG ETSI WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 Preparing the SIM card All new SIM cards have to be registered with the network provider before they can be used usually by calling the network provider or registering on their website please refer to the instructions supplied with your SIM card During the registration procedure a confirmation code or text message is usually sent to the SIM cards telephone number to be able to read and react to the message you will need to insert the SIM card into an unlocked mobile phone After successfully registering the SIM card ensure there is sufficient credit on the card for programming confirmation texts to be sent from the GSM Remote Control Switch You MUST ensure that the PIN request is disabled from the SIM card before inserting it into the GSM Remote Control Switch If you do not disabl
7. chedule the ON OFF for the 13 N YYYYMMDDHHMM Master relay off time N 0 Switch Off the Master Master Relay 2013 10 10 16 33 Relay N 1 Switch On the Master 2013 10 10 16 31 Thu Relay When the programmed ne time is reach the relay is YYYY 4 digit for Year either on or off all the MM 2 digit for Month admin will get the reply DD 2 digit for Date SMS as per below HH 2 digit for Hour MM 2 digit for Minutes Since time is up Master relay lt OFF gt E 2013 10 10 16 33 Thu vere ser 13 0 201310101633 which Note if the system is means 2013 10 10 16 33 to only ON after the switch off the master relay scheduled time the unit Hitu F If reprogram the date it will will still running take the last as the correct accordingly date If you program the date System startup that already past the system Master Replay lt OFF gt will alert you 2013 10 10 16 33 Thu 10 Checking the schedule time for T Master relay on time Checking the schedule time for Master Relay ON OFF Master relay off time Master Relay ON OFF when 2013 10 10 16 33 the time reach the system will operate and it will delete the 2013 10 10 16 35 Thu schedule time automatically 11 Delete the schedule time for the 15 N Master relay on time N 0 Delete schedule of Relay Master Relay ON OFF Master relay off time OFF Time N 1 Delete schedule of Relay 2013 10 14 11 08 Mon ON Time 12 SMS Reply Message when the 21 N Message switch lt ON gt N 0 means SMS
8. e the PIN request the GSM Remote Control Switch will not work If the PIN request is not disabled and the unit is switched on more than 3 times you will have to reset the PIN using the PUK code which will have to be obtained from the service provider To check the PIN request status of your SIM card place the card in an unlocked mobile phone switch the phone on If you are able to make calls without entering a PIN number the PIN request is disabled If a PIN number is requested refer to the instructions supplied with the SIM card and then look through the phones options for the disable PIN request and disable it You MUST disable any voicemail that is set up on the SIM card the codes shown below are for UK networks only please refer to your network operator if outside the UK Vodafone 1210 gt Send you will hear order is accepted and confirmed O2 Call 1760 gt Send you will hear order is accepted and confirmed T Mobile Call 222 and follow instructions Orange Call 450 and follow instructions The SIM card is now ready to use We recommend that if you are using a pay as you go PAYG SIM card that you choose to automatically Top Up when the cards credit falls below a certain limit please contact your network provider or visit their website for more details Most but not a using post paid SIM cards will be de activated by the network if not used to make an outgoing voice call or send an SMS text messag
9. e within a specific period To prevent this simply send the GSM Remote Control Switch a text command 0 PWH then 2 it will reply by text message do this once a month to keep the SIM card active WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 Troubleshooting 1 Red power LED not alight Ensure that your DC power supply is connected correctly positive to terminal 220v and negative to terminal N Verify 12 volts is present using a volt meter 2 Blue network LED flashing every one second and not every 3 seconds Ensure your SIM card has been activated and that the PIN request has been disabled If the unit is in a low signal strength area consider using an external GSM antenna or changing to another network provider 3 lam not receiving confirmation test messages when program the administrators number Ensure your telephone number is in the Administrator list and that sending text messages to your number is enabled 4 lam not receiving any text messages when initially programming the unit Ensure the unit is connected to the GSM network by observing the blue network LED it should be flashing once every 3 seconds see 2 above Ensure the SIM card has credit 5 The unit has been working for several months and has now stopped responding to calls and text commands Most but not all PAY SIM cards will be de activated by the network if not used t
10. must perform the next command in 10 minutes If you did not do anything the system will exit from programming mode Change Password 0 1234 new password For example if you need to change to the new PW of 1212 0 1234 1212 New password lt 1212 gt 2013 10 10 16 07 Thu Maximum 4 digits of passwords If you decide to protect your privacy you can change the factory password to your new password Enter the factory password follow by your new password 3 Add telephone number into the admin list 1 1 telephone number For example set Admin number 18617185300 into admin 2 1 2 18617185300 Administrator 1 15989427391 2 18617185300 3 4 5 2013 10 10 16 08 Thu Set Admin Numbers 1 1 set Ist admin number 1 2 set 2nd admin number 1 3 set 3rd admin number 1 4 set 4th admin number 1 5 set Sth admin number Only the number in the list can receive alarm texts message and active the relay output You can add up to 5 telephone number into the admin list 4 Check phone number you program in the list XJF Administrator 1 15989427391 2 18617185300 3 4 5 2013 10 10 16 08 Thu WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 5 Delete the admin number in the list 3 N Administrator Delete Admin Number 1 15989427391 Delete 1st admin 3 1 N Admin number 1 5 2 Delete 2nd admin
11. o Of WT 1672 ZIN pm lt Messages WT 1672 Administrator 18617185299 You already finish the set up Now you can use your mobile phone call to the SIM Card number switch the device on permanently Another call to the SIM Card will switch the device off permanently If you do not required to go through details setting please process to STEP3 Final Installation and Setup WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 Factory Reset If you required to change the administrator number in the future simply press the button FACTORY at the mother board until you hear the du This means the unit back to the factory default Press until you hear the du sound This means you already reset the unit to factory default Now you can start to call again to set the administrator This method of setting is only allowed to set 1 administrator number If you wish to set more administrators please go to Step 3 Installation and set up WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 Step 2 Advance Set Up First Step of programming you must enter the factory passwords of 1234 and go programming mode inside the You only can perform the next commands after enter into programming mode 0 1234 You get administrator privileges 2013 10 09 00 33 Wed When you enter 0 1234 you enter into the programming mode You
12. o make an outgoing voice call or send an SMS text message within a specific period To prevent this simply send a txt command 0 PWH then 2 it will reply by text message do this once a month to keep the SIM card active WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 Warranty Witura Technology Sdn Bhd warrantees the WT 1672C GSM Remote Control Switch against defective parts and workmanship Witura Technology Sdn Bhd shall at its option repair or replace the defective equipment upon the return of such equipment to any Witura branch This warranty applies ONLY to defects in components and workman ship and NOT to damage due to causes beyond the control of Witura such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper application of the equipment Note Wherever possible return only the PCB to Witura Service Centres DO NOT return the enclosure The WT 1672C is a product of Witura Technology Sdn Bhd And is manufactured by Shenzhen Witura Telecommunications Co Ltd WARNING For safety reasons only connect equipment with a telecommunications compliance label This includes customer equipment previously labelled permitted or certified WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9
13. upply the red power LED will light indicating power is present the blue network LED indicator will initially flash quickly once logged onto the network it will flash more slowly approximately one every 3 4 seconds It is recommended that the GSM Remote Control Switch be programmed to operate as required before final installation WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 a Connection Details If you are unsure how to connect the device you wish to control refer to a qualified person Connector 1 2 3 1 2 3 4 5 Description Digital Analogue Input Relay Connection aa Pulse Digital Or Temperature NO NC COM L N Counter Analogue Input Note 1 The Temperature Input is only work with Witura Temperature Sensors 2 The Connect 4 and 5 is inside the Industry Power Supply Example Connection with Washing Machine Washing Machine Internal Circuit WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1 9 Example Connection with Coffee Machine P2075 White BATTERY NO NC COM E oN 12VDC P2168 Ghee P20 Whie or Goel Ga i DD Eme RIS Seams 5 c P2179 Bhe Example Connection with Catering Equipment Wiring Diagram Model WT 1672C GSM Remote Switch id aS GN L NO NC COM L WITURA TECHNOLOGY SDN BHD WT 1672C GSM Remote Control Switch User Manual V1

Download Pdf Manuals

image

Related Search

Related Contents

Velocità di spostamento - ESAB Welding & Cutting Products  Dossier d`information Euro Pharmat DISPOSITIF MEDICAL PINCE  Manual - softime  FLX Quick Start Guide  EMOBILE GL09P 取扱説明書  Istruzioni - INNO  Retrouvez plus d`infos dans le fichier PDF  Digi PO-HS500 User's Manual  cgâyo - Eberhard & Co  充填機用電磁流量計 MGR形(口径8mm仕様) 取扱説明書  