User Manual STIM210 and STIM300 Evaluation Kit-PCI
Contents
1. Comm cable to PCI card port DOK411 rev O 11 23 2014 USER MANUAL Evaluation Tools AP Ag sensonor STIM210 STIM300 Evaluation Kit PCI 6 First PC software start up 1 Navigate to the Sensonor evaluation tools folder from Windows start menu Click on the shortcut named STIM300 EVK or STIM210 EVK to start the PC software For full functionality the computer user should have Local Administrator rights Devices and Printers Default Programs a 1 m 1 FL Ly T 11 SharePoint 4 Back Help and Support d Search programs and files Figure 10 Starting PC software from Windows 7 start menu 2 A pop up box for software registration appears Fill in the open fields and press Submit The default email client opens Press Send in order to complete this step user information is sent to Sensonor for support issues This step will only have to be completed once ME 5 STIM300 EVK PC Software V1 0 File Help RNS Normal mode Service mode Measure Logging STIM 300 Param Apply voltage Connect a Reset Request Request Request to HW device config DG identity DG serial DG V Off Response Disconnect Device Registration from HW SSS Welcome to STIM300 Evaluation Kit Please spend short time to register this installation NORMALM ODE Figure 11 Welcome message and software regi
2. ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI Table of contents Nu udiiizc MEHR 2 1 1 GENELDE CRP ION eaea ET 3 1 2 CONFIGURABLE AND READABLE PARAMETERS 1 20 ss sa sess sese ess sese 3 2 KI CONTENTS incana AA A E E A aa h NE E A RE 4 Jj SYSTEM REQUIREMENTS 2 05 a aA A A a a a Gone Aa N aAA 4 REP 4 4 1 INSTALLATION OF NI SERIAL DRIVER va 2 Lus vu Ere odes 5 4 2 VERIFICATION OF SERIAL DRIVER 5 888 6 4 3 INSTALLATION OF PC 7 4 4 INSTALLATION PCI CARD 11 5 CONNECTING THE TO 11 FIRST PC SOFTWARE START UP De LE 12 7 INTRODUCTION TO PC SOFTWARE ce nscr aee Uess Unas ases xu paa nnmnnn nnnm 17 7 1 P
3. g Development Inertia Products Projects STIM300 D400 Test STIM300 EVAL kit Software STIHW connected OK Figure 17 Normal mode panel DOKA11 rev O 15 23 2014 AID Ag sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 9 A green LED Data arriving from device n indicates that data is received from the gyro module s Verify the communication to module by clicking on the Request config DG button An example of such a result is shown in Error Reference source not found The system is now ready for use DOK411 rev O z STIM300 EVK PC Software V2 0 EET Normal mode Service mode Measure Logging Parameters Apply voltage Connect 4 E to HW d Off Disconnect Device from HW 1 Data arriving from device 1 d Data arriving from device 2 a Reset device Response Part no rev FW revision Samplefreq DG contains accelerometer data DG contains inclinometer data DG contains temperature data DG contains AUX data DG term RS422 bitrate RS422 stopbits RS422 parity Line term X axis gyro Y axis gyro Z axis gyro Output unit X axis acc LPF Y axis acc LPF Z axis acc LPF STIM 300 2 sensonor Request Request Request config DG identity DG serial DG Active Active Active Angular rate 33 33 33 Active Active Active Acceleration 2 33 33 34 g Development Inertia Products Projects STI
4. Saved data An example of a result file is shown in Figure 24 for a standard datagram measurement series of gyro module 1 A description of each of the columns of the data log file is found in the table that follows DOKA11 rev O 20 23 2014 amy ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 20111220 181756 14 Notepad Ele Edit Format View Time s x 5 v s z s 515 RXCRC CalcCRC DG ID 0 027696 0 085083 0 063416 0 1 9016 0 107117 0 117615 0 142639 0 095825 0 188 82 0 105164 0 103699 0 1942 5 0 051208 0 1862 9 0 168823 0 007507 0 323853 0 132996 0 028870 0 377380 0 026855 0 097656 0 327942 0 071472 0 123718 0 309814 0 059631 0 120972 0 302856 0 042847 0 166870 0 286865 0 124573 0 206482 0 263794 0 096802 0 179993 0 188232 0 053101 0 155334 Figure 24 Result file example DG Col STIM210 STIM300 Comments 1 Time seconds derived from sample rate First Time s GYROX 02 sample is always zero GYRO_X Inclinometer signal Y axis 7 ACC TMP STS i c 6 P o Table 7 Result file content standard datagram DOKA11 rev O 21 23 2014 ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 7 6 Logging panel Panel content Functionality and description Start button otarts data logging stop button otops data logging Stop criteria slide User
5. Detailed diagnostic information includes RAM and flash checks stack handling checks status of internal voltage supply references and various parameter reports for each measurement axis are available from the supported SERVICE mode Note Time of Validity TOV and external trigger functionalities of STIM300 are not supported by the EVK PC software DOKA11 rev O 3 23 2014 ae ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 2 contents PCI to RS422 interface card STIM210 STIM300 communication and power cable Memory stick with o software STIM210 and STIM300 o User manual for evaluation kit e Allen Wrench for fixing connector of communication and power cable to the gyro module Hard copy of User manual Note that the evaluation kit does not include a STIM210 STIM300 gyro module This must be ordered separately 3 System requirements Windows XP SP2 or later Windows Vista Windows 7 32 64bit 1free USB port and 1 free PCI slot e Quad core processor recommended when simultaneously logging data from two gyro modules 4 Getting started Preparing your system involves the following steps DOK411 rev O 4 23 2014 ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI Installation of PCI to RS422 serial driver Install the serial driver from the memory stick included in the kit This procedure is self instruc
6. 3 Ports COM amp LPT 77 Communications P B 485 1 SN 00CB33 Communications Port COM6 D Processors D Security Devices amp Sound video and game controllers System devices E Universal Serial Bus controllers Figure 3 COM port assignments for PCI card cable in Windows 7 DOK411 rev O 6 23 2014 sensonor USER MANUAL EvaluationTools STIM210 STIM300 Evaluation Kit PCI 4 2 Installation of PC software Install the PC software by running setup exe found on the included memory stick Follow the on screen instructions to complete the installation See the following screen shots for guidance The PC software can also be downloaded from the Sensonor support site Check this site regularly for updates L 5114300 Evaluation kit lol x STIM300 Evaluation kit It is strongly recommended that you exit all programs before running this installer Applications that run in the background such as virus scanning utilities might cause the installer to take longer than average to complete Figure 4 PC software installation 1 of 6 Installer initializes DOK411 rev O 7 23 2014 ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI VW STIM300 Evaluation kit Destination Directory Select the primary installation directory All software will be installed in the following location s To install software into different locati
7. Hz 33 ACCELEROMETER LP FILTER 3dB FREQUENCY X AXIS Hz 33 ACCELEROMETER LP FILTER 3dB FREQUENCY Y AXIS Hz 33 ACCELEROMETER LP FILTER 3dB FREQUENCY Z AXIS Hz 33 INCLINOMETER LP FILTER 3dB FREQUENCY X AXIS Hz 33 INCLINOMETER LP FILTER 3dB FREQUENCY Y AXIS Hz 33 INCLINOMETER LP FILTER 3dB FREQUENCY Z AXIS Hz 33 AUX LP FILTER 3dB FREQUENCY Hz 33 AUX COMP COEFF 1 0000000 00 0 0000000e 00 DATAGRAM RATE ACCELERATION INCLINATION TEMPERATURE AUX DATAGRAM TERMINATION NONE 17 23 E ioj STIM 300 9 sensonor Active device 1 SERVICE MODE Figure 19 Service mode panel 2014 Ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 7 1 2 Measure panel STIM300 EVK PC Software V1 0 Pel ES File Help Normal mode Service _ Measure Logging Parameters STIM 300 sensonor EN M x axisdata DG ID Sample rate 0 2 v axisdata Q 7 Z axis data Acc unit nhan o Data e Inc unit v 4 Active device 1 Scale Full range DG type Cursors Off Cursor1 Cursor2 Delta 4 4 0 000 4 0 000 y 3 4 0000 Angular rate 7 5 3 Time s c Program Files x86 VSensonor evaluation tools STIM300_EVK STIM300_EvalKit INI INTERACT IVE MEAS
8. can select between Manually No of samples and Time elapsed for stopping a measurement series Samples box Used for defining number of samples when logging a finite number of samples Time elapsed Shows the time elapsed since start of test Samples Shows number of samples acquired Shows number of CRC errors normally 0 otherwise the user should consider to reject results data in any analysis order to re establish data collections from module Table 8 Logging panel descriptions Log to file capability Quad core processor is recommended when measuring on two gyro modules simultaneously The size of the log file is only limited by the available space on the storage media in use The path for result file storage is defined in the active parameter file The program should be run with administrator rights to ensure the creation and storage of the result file 7 7 Parameters panel Panel content Functionality and description Password Current valid password to be able to edit the parameters list The default password is stim Folder for result file storage Path to storage e g c userdata test What priority will this program run with Instructs the program priority for the PC operation system What format to use for result files ASCII text by default Can be changed to 8 byte binary Device communication IMPORTANT MESSAGE Always verify hardware connections and COM port settings before trying to connect to the
9. datagrams unexpected datagrams are received Unable to read configuration datagram to determine the output unit Failed to acquire the requested number of datagrams from the gyro Unable to synch with DG stream module unable to get in synch with datagram stream Error encountered when trying to print check configuration Failed to print the graph check that a printer is configured The specified pathname cannot be created either due to access rights Unable to create result folder specified by parameter errors in the path specification Unable to enter service mode does not receive expected response to 9 Unable to enter service mode command 20 Unable to save parameters to active INI file Error encountered when trying to save parameters onto INI file The edit mode of parameters are active unable to exit the program until 1 Edit mode of parameters is active unable to exit edit mode is ended You are about to change the RS422 bit rate If are you using the USB kit hardware provided by Sensonor please notice that you will not be able to communicate with the device if you warning to the user about limitations for certain RS422 hardware N N N A change to something else than supported 460800 b s For the PCI card there are no worries it supports all available bit rates Unable to open or create the
10. specified file in the selected folder try 23 Unable to create save to selected file check access rights to folder another filename and or location The reason may be lacking access rights to the folder or illegal filename format 24 Unsupported datagram received When trying to read datagrams into memory a datagram type not supported by the EVK is detected Table 10 Possible messages given by the program DOK411 rev O 23 23 2014
11. ANELS OVERVIEW cccccececcccececcceccccececuceecececceuuaececscaunenececauuuneneusesunenecscauauaunetscaeaunenstauaeaenetscuuauuesstauauaenecscauaunenenss 17 7 2 MAIN PANEL 6 38 sese essa sa gases ssa 19 7 3 NORMAL MODE PANEL 5 56 8 8 288 19 7 4 SERVICE MODE PANEL 6 8 19 7 5 MEASURE PANEL 6 20 7 6 LOGGING PANEL 6 22 7 7 PARAMETERS PANEL DESCRIPTIONS 000 4 0000001 sire esee sese e essi ess sage eaa 22 7 8 MESSAGES FROM THE 23 DOKA11 rev O 1 23 2014 4 sensonor USER MANUAL EvaluationTools STIM210 STIM300 Evaluation Kit PCI 1 EVK features PCI connectivity to PC Up to 2000Hz sampling rate supported Temperature measurements supported Service mode access o Full gyro module information o Full gyro module configuration capability o Detailed gyro module diagnostics o Help section Measure panel o Data presentations and save data to file capability o Custom scale and zoom functions o CRC check Logging panel o Support for any measurement duration on
12. L Evaluation Tools STIM210 STIM300 Evaluation Kit PCI Note Changes made for the gyro module in Service mode are only stored permanently in flash memory when the save command s subsequently is sent to the gyro module Panel content Shows a list of available commands See product datasheet for details Complete command window Contains the complete command to be sent The command is auto completed by the software during usage of the listings in the Available commands window Left click inside the Complete command window brings up a list of previously sent commands Right click enables manual command entry Send command button Sends command to the gyro module Active device indicator Indicates active gyro module Corresponding COM port is specified in the active oarameter file Command response window Shows the responses to commands from the gyro module See product datasheet for details Erase button Clears the content of the command response window Save button Saves the content of the command response window to a text file with a date and time tag Table 5 Service mode panel descriptions 7 5 Measure panel Panel content Functionality and description Measure button Starts a measurement series Samples box Defines the number of samples to be collected max 50 MS Saves data from a completed measurement series to a result file The file path defined in the active parameter file is proposed Selects which axis data to present in th
13. M300 D400 Test STIM300 EVAL kit Software Ini Hw connected OK Figure 18 Example of Request config DG response 16 23 2014 Ag sensonor 7 7 1 Introduction to PC software Panels overview USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI In addition to the Normal mode and Parameters panel other panels are also available 7 1 1 Service mode panel amp STIM300 EVK PC Software V1 0 File Help Available commands Measure Diagnostic Datagram Transmission Termination Unit LP filter Sampling freq AUX settings Save Recall Help Special ll m E E E H E E c Program Files x86 Sensonor evaluation tools STIM300_EVK STIM300_EvalKit INI DOK411 rev O Normalmode Service mode Measure Logging Parameters Send command Complete command Command response SERIAL NUMBER N25581142930015 PRODUCT STIM300 PART NUMBER 00000 0000 0000 REV FW CONFIG SWD11895 REV 9 GYRO OUTPUT UNIT s ANGULAR RATE ACCELEROMETER OUTPUT UNIT g ACCELERATION INCLINOMETER OUTPUT UNIT g ACCELERATION SAMPLE RATE samples s 125 GYRO CONFIG XYZ ACCELEROMETER CONFIG XYZ INCLINOMETER CONFIG XYZ GYRO LP FILTER 3dB FREQUENCY X AXIS Hz 33 GYRO LP FILTER 3dB FREQUENCY Y AXIS Hz 33 GYRO LP FILTER 3dB FREQUENCY Z AXIS
14. UREMENTS Figure 20 Measure panel 7 1 3 Logging panel STIM300 EVK PC Software V1 0 ENS ini xj File Help STIM 300 Normal mode Service mode Measure Logging Parameters 4 sensonor Stop criteria Start Manually No of samples Samples 3 1000 Time elapsed 00 00 00 Devices to be measured Serial no Samples acquired CRC errors Resynch s 1 5581142930015 0 0 0 0 0 0 c Program Files x86 VSensonor evaluation tools STIM300_EVK STIM300_EvalKit INI LOGGING Figure 21 Logging panel for saving data to file DOK411 rev 0 18 23 2014 ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 7 2 Main panel menu Menu File New parameter file Creates a new INI file with default settings Note that the new INI file must be edited to match the hardware and module configuration settings File Open parameter file For loading an existing INI file File Save parameter file as To save current parameter settings with a new file name File Print parameters For printing the current Parameters content on the default printer software and user manuals can be downloaded Help About Information about the program Program name publisher and software revision number Table 3 Menu contents Help New parameter file Check for updates Open parameter file About Sav
15. dding Changing STIM300 E valuation kit Files NI VISA 5 0 3 Run Time Support Click the Next button to begin installation Click the Back button to change the installation settings Save File lt lt Back Next gt gt Cancel Figure 7 PC software installation 4 of 6 20 STIM300 Evaluation kit Overall Progress 12 Complete Cancel Figure 8 PC software installation 5 of 6 Installation progress DOK411 rev O 9 23 2014 a sensonor USER MANUAL p IY 4 V IN i L _ i V7 J gi 2 1 VJ i Evaluation Tools JOE tion STIM300 Evaluation kit Installation Complete Figure 9 PC software installation 6 of 6 Installation complete DOKA11 rev O 10 23 2014 ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 4 3 Installation of PCI card a M Miu E neve re nomen een mE Ar E Smet IU aue Ns LE 74 7 4 PN Disconnect power from your computer prior to installation Following your computer manufacturer s directions insert the card into a free PCI slot 5 Connecting the STIM to your PC Power cable to USB port a HE os o n S E E 9 2 6 N T 7 5 5 3 5 2 2
16. device RS422 port to device 1 RS422 port to device 2 RS422 Bitrate bit s RS422 Stopbit 1 or 2 Default is 1 RS422 parity p The GPIB card to use Interface for external power supply optional If card s are in use the first card will be assigned to 0 second to 1 etc Default value is 0 Type of power supply used External power supply optional Default None not in use Agilent E3631A E3633A and E3644A are supported Interface that the power is connected with Interface type for external power supply optional Default None not in use RS232 for Agilent E3631A only and GPIB supported Port or address to power GPIB port for external power supply optional Default 0 not in use Selectable up to 31 Voltage on output of power supply V Voltage output on external power supply optional Default value is 5 1 V Value should be within the supply voltage range of the gyro module See product datasheet for details Current limit on output of power A Current limitation on external power supply optional Default value is 1 0A Table 9 Parameters panel descriptions DOK411 rev O 22 23 2014 sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 7 8 Messages from the program Messages that the program can display are listed in Table 10 o Message Description This application is already running The program is already started a second instance will not be allowed S
17. e graph area up to 3 axes can be plotted simultaneously Indicates active gyro module Corresponding COM port is specified in the active oarameter file CRC and DG ID LEDS Status on all CRC checks and DG IDs GREEN OK RED FAIL Data box Selects which datagram content to be shown Several options are available depending on the active datagram type Left click inside box to display available selections The plot updates immediately if a measurement series has been done Enables user to change Y axis scaling Full range User defined or Auto Left click inside box to display available selections Displays the sample rate used in measurement Displays the output unit for all measurements Angular Rate Incremental Angle etc Displays the type of datagram received Saves the plot to a JPG file Prints a picture of the plot to the default printer Resets zoom level to 1 1 if ZOOM is active See below Zoom icon Enables a custom zoom of the presented results in the strip chart graph area according to placement of the cursors Cursors On Off switch Enables usage of cursors default is Off Shows the location of cursor no 1 Shows the location of cursor no 1 Shows the delta between the two cursor locations X and Y values A blue continuous line above plot area shows the measurement series progress Lower bar on panel Shows the INI file in use and the active mode INTERACTIVE MEASUREMENTS bi Table 6 Measure panel description
18. e parameter file as Figure 23 Help menu Print parameters Edit parameters Exit Figure 22 File Menu 7 3 Normal mode panel Panel content Functionality and description Connect to HW Connects to interface hardware Opens COM port according to settings specified in active parameter file Indicator for hardware connection A GREEN light indicates the COM port is opened Disconnect from HW Disconnects from interface hardware Closes the COM port Apply voltage switch On Off Toggles supply voltage if connected to an external power supply Controls certain functions of the PC software Device box Device number and corresponding COM port according to active parameter file Selects which gyro module is activated for datagram requests in Normal mode Service mode operations and measurements in Measure panel Does not apply for Logging panel Displays response to special datagram requests N and I datagrams Table 4 Normal mode panel descriptions 7 4 Service mode panel Service mode is used for gyro module configuration oervice mode is entered by clicking on the Service mode tab next to the Normal mode tab after the gyro module has been powered up Service mode usage functionalities and descriptions are listed in Table 5 Exit from Service mode to Normal mode by selecting one of the other panel tabs Normal Logging Service or Parameter panel tab DOKA11 rev O 19 23 2014 ay sensonor USER MANUA
19. l What format to use for resultfiles ASCII text IMPORTANT MESSAGE Always verify hardware connections and COM port settings before trying conne C 52422 port to device RS422 port T toO devtee RS422 Bitrate bits s 921600 RS422 Stopbit RS422 parity External hardware The GPIB card to use Type of power supply used Interface that the power is connected with Port or address to power Voltage on output of power V Current limit on output of power A c Program Files x86 VSensonor evaluation tools STIM300_EVK STIM300_EvalKit INI PARAMETERS Figure 14 Edit the INI file in order to verify correct COM port settings 6 Set the correct value for RS422 bit rate according to the configuration of the STIM unit r x 4 STIM300 EVK PC Software V4 0 0000 EXP STIM 300 gay sensonor Password Folder for result file storage C userdata test What priority will this program run with Above normal What format to use for resultfiles ASCII text Device communication IMPORTANT MESSAGE Always verify hardware connections and COM port settings before trying to connect to the device RS422 port to device 1 RS422 port to deyice 6 Bitrate bits s 921600 RS42 STODD RS422 parity External hardware The GPIB card to use Type of power supply used Interface that the power is connected with Port or address to power Voltage on output of
20. ly limited by hard drive available memory and processor capacity of PC o Various stop criteria for measurements available Manually of samples or Time elapsed Measurements on 2 gyro modules simultaneously supported requires additional cable STIM210 STIM300 EVK PCI DOK411 rev O 2 23 2014 ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 1 1 General descriptions The evaluation kit provides measurement and configuration access to STIM210 and STIM300 gyro modules Configuration graphical result presentation and saving data to file functions are supported The single voltage supply required for the gyro module operation is provided from an USB port Feature 31 jAvalable _ Temperature available Yes Acc 8 Inc temp STIM300 only Acc Inc amp AUX output available Yes STIM300 only TOV AUX in External trigger Yes break out cable available Transmission rate supported Up to 5 34Mbit s Table 2 Features of PCI kit 1 2 Configurable and readable parameters Configurable parameters Output format angular rate increment angle etc Datagram format standard extended etc Sampling rate Bandwidth Low pass filter frequency RS422 transmission bit rate Number of stop bits in datagram Parity Line Datagram termination Readable parameters Part number Serial number Firmware revision Hardware revision Gyro module diagnostics
21. on s click the Browse button and select another directory Target directory for application C Program Files x86 Sensonor evaluation tools STIM300_EVK Browse Target directory for National Instruments software C Program Files x85 National Instruments Browse Figure 5 PC software installation 2 of 6 License Agreement You must accept the license s displayed below to proceed NATIONAL INSTRUMENTS SOFTWARE LICENSE AGREEMENT INSTALLATION NOTICE THIS IS A CONTRACT BEFORE YOU DOWNLOAD THE SOFTWARE AND OR COMPLETE THE INSTALLATION PROCESS CAREFULLY READ THIS AGREEMENT BY BECOME A PARTY TO THIS AGREEMENT AND BE BOUND BY ALL OF ITS TERMS AND CONDITIONS CLICK THE APPROPRIATE BUTTON TO CANCEL THE INSTALLATION PROCESS DO NOT INSTALL OR USE THE SOFTWARE AND RETURN THE SOFTWARE WITHIN THIRTY 30 DAYS OF RECEIPT OF THE SOFTWARE WITH ALL ACCOMPANYING WRITTEN MATERIALS ALONG WITH THEIR CONTAINERS TO THE PLACE YOU OBTAINED THEM ALL RETURNS SHALL BE SUBJECT TO NI S THEN CURRENT RETURN POLICY C accept the License Agreement do not accept the License Agreement lt lt Back Nest gt gt Cancel Figure 6 PC software installation 3 of 6 DOK411 rev O 8 23 2014 amy sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 3 STIM300 Evaluation kit Start Installation Review the following summary before continuing A
22. power V Current limit on output of power A c Program Files x86 Sensonor evaluation tools STIM300_EVK STIM300_EvalKit INI PARAMETERS Figure 15 Edit parameters here RS422 bit rate DOK411 rev O 14 23 2014 ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 7 Connect the gyro module by pressing the Connect to HW button in the Normal mode panel A green LED light indicates that the COM port is active 5 STIM300 EVK PC Software V2 0 mt A Normal mode Service mode Measure Logging Parameters STIM 300 mem Apply voltage Connect d Reset Request Request Request to HW device config DG identity DG serial DG Response Disconnect from HW Data arriving from device 1 Ml Data arriving from device 2 a g Development Inertia Products Projects STIM300 D400 Test STIM300 EVAL kit Software Ini Hw connected OK Figure 16 Normal mode panel after first hardware connection 8 Press the Apply voltage control switch position to The pop up message telling Turn on device supply voltage appears Press OK 5 STIM300 EVK PC Software V2 0 Sie Normal mode Service mode Measure Logging Parameters STIM 300 Apply voltage Connect a Request Request Request g config DG identity DG DG Off Device Disconnect from HW 31 Data arriving from device 1 a x MESSAGE 12 Turn on device supply voltage
23. stration ParaFile 3 A pop up window will ask for a parameter INI file Select the INI file available in the installation folder by default and press Load DOK411 rev O 12 23 2014 ay sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI amp Select parameter file i xi C Program Files x86 XSensonor evaluation tools STIM300_EVK Look in STIM300_EVK 1 E2 E Name Date modified Type STIM300_Evalkit INI 08 12 2011 15 39 Configuration se Recent Places Libraries A Computer Figure 12 INI file selection 4 The Normal mode panel is shown t STIM300 EVK PC Software V1 0 File Help Apply voitage On 3 Off Disconnect c Program Files x86 Sensonor evaluation tools STIM300 5 1M300 Evalkit INI NORMAL MODE Figure 13 Normal mode panel after selecting INI file DOKA11 rev O 13 23 2014 4 sensonor USER MANUAL EvaluationTools STIM210 STIM300 Evaluation Kit PCI 5 Verify the correct COM port settings in the Parameters view If needed port setting needs to be changed do this by double clicking on the value and enter correct value The default password to edit is stim STIM300 EVK PC Software V4 0 0 00 File Help Password Folder for result file storage C userdata test What priority will this program run with Above norma
24. tive Follow the on screen messages without doing any configuration changes Figure 1 and Figure 2 show two of the messages that appear during serial driver installation The serial driver can also be downloaded from the Sensonor support site Check this site regularly for updates nstallati b oo view the following summary before continuing INSTRUMENTS Adding or Changing NI Serial 3 6 Documentation Serial Configuration NI Serial 3 6 for LabVIEW Real Time NI VISA 4 6 2 NI Spy 2 7 1 NI Measurement amp Automation Explorer 4 5 2 Click the Next button to begin installation Click the Back button to change the installation settings 3 NI Serial 3 6 4 NATIONAL INSTRUMENTS The Ni Serial software has been installed Please shutdown your system and insert your NI Serial hardware Figure 2 NI serial driver DOK411 rev O 5 23 2014 AE sensonor USER MANUAL Evaluation Tools STIM210 STIM300 Evaluation Kit PCI 4 1 Verification of serial driver set up Launch Device Manager Start gt Control Panel gt Hardware and Sound gt Devices and Printers gt Device Manager Verify that the serial driver installation has completed successfully An example is shown in Figure 3 Make note of the assigned COM port numbers at this point as this information is needed later for connecting to the gyro module s from the PC software Device Manager Ele View Help miss 4
25. top loading of 2 instance 2 Wrong password entered The password entered does not match the required one for this INI file Did not receive the expected response to the sent service mode No response to message was received command There is no measurement data available for storage To be able to save measurement data there must be data available Saving of measurement data failed unable to open or create the Unable to open the selected file selected file Failed to acquire the requested number of datagrams from the gyro Unable to allocate the required memory module due to error when trying to allocate memory for temporary storage Even after retries the expected datagram is not received as response to No product identification datagram received command sent Even after retries the expected datagram is not received as response to No configuration datagram received command sent Even after reties the expected datagram is not received as response to No serial number datagram received command sent Failed to acquire the requested number of datagrams from the gyro 0 datagrams received module no recognizable datagrams received Instruction to user when running without controlled power supply Instruction to user when running without controlled power supply Error encountered when trying to control voltage Failed to control the specified power supply Unexpected DG ID received When waiting for