1. Up and down arrows increase decrease ring Select or enter and speech volume Re coding the Handsets Adding an Extra Handset Occasionally a system may need re coded when it arrives on site If the handset does not ring when the call button is pressed please perform the following steps 1 Press and hold the code button on the speech panel as shown for 3 seconds 2 Press and hold the code button on the handset use a fine object like ball point pen for up to 10 seconds 3 While holding the handset should bleep once then bleep again then emit a melody confirmation tone aS TER Inside Speech Panel ax D a8 Code Button LI Code Button Once the melody is heard the handset should then be working The system should now be ready for testing Page 11 Testing 1 Press the call button on the intercom and all coded handsets should ring max 4 handsets Calling AES 2 Answer the call on any handset and adjust speech volume while on the call as per instructions 3 Activate the door or gate release and check the relay activates Adjusting time on Audio Handset Press MENU for more than 2 seconds and then use up and down arrow keys to set hour Press MENU again to cycle to minutes and adjust Press MENU once more to end the process Maintenance of the Intercom The
2. 50 per wall 0 Installation Assuming satisfactory operation at full range you are ready to fully install the product RS al 30 y Mount the intercom at the desired height for pedestrian or car users The camera angle is wide at 90 degrees to cover most scenarios Loosen top 2 screws only yy Q A y Hinge front door Side View Tip Do nat drill holes in the wall with the intercom in positon otherwise dust may get around the camera window and impair the camera view Page 3 Mounting the Antenna x Antenna Antenna II gt M NAT M Y Mount the antenna as high as possible to achieve longest range Narrow Signal Beam Narrow Signal Beam Top View Side View TIP Antenna beam width is approximately 40 degrees For short range door intercoms ask your distributor or dealer for an omni pole type antenna with 360 degree beam angle Power Supply TIP Most technical calls received are due to installers using CAT5 or alarm cable to power the unit Neither are rated to carry enough power 1 5 amp peak Please use following cable sizes Up to 2 metres 6 feet Use minimum 0 75mm 18 gauge Up to 4 metres 12 feet Use minimum 1mm 16 gauge Up to 8 metres 24 feet Use minimum 1
3. 5mm 14 gauge Call point Call point Power supply Excessively long cable Power supply t XK nv ee WARNING Warranty VOID if power cable requirements are not followed Mains power Page 4 Wiring Video Transmitter al Connect Antenna TT TT Antenna p 4p leads HERE 12v DC PSU I 2 metre Cable GAITA Do not cut ot extend or join Intercom Relay u Full Auto Backlit Advanced y Features Optional Keypad Module ba o Wo gt gt COM Relay 3 S3 C EX N C 2239 O 75 z o m 2 Relay 1 Relay Wiring Tips Connection to Automatic Gates x e Connection to Magnetic Lock Intercom Gate Ba Relay Controller ane neam ojo START so a S com R Keypad DC Magnetic Relay Lock Keypad Relay Egress Connection to Door Strike Lock GND o AC or DC Intercom Viele SS toos Backi gt ee 42 COM Optional 2 NC Y loNWo Push to Icom slov Seperate Exit 12v dc lock PSU Je we SO Note If no keypad fitted Keypad com 4 use additional timer Relay mod
4. 9 for relay 1 20 relay 2 codes 001 100 for relay 2 j iaj j A Val 100 available 001 100 for relay 3 Rineoge 4 6 digits alldate 30 relay 3 codes 100 available Example Add user 31 to have access code 5555 operating relay 2 3 Fb 2 We IEEE E Group 2 Add code Location 31 Pin code 5555 Validat oO Programming relay output times and modes ala ooo joa ja 51 LOS 0 start stop toggle mode latching Validate 52 relay2 1 99999 seconds momentary operation 53 relay3 Delete a user code even if you don t know the code 10 relay1 20 relay2 Delete code ID location to be deleted Validate 30 relay3 Page 7 Delete an entire group of codes o Ls 2 o 10 relay1 group i 20 relay2 group Super delete code Validate 30 relay3 group Programming super user codes A super user code can activate any of the 3 relays o 2 Location 4 8 digit code Validate Restoring defaults When in programming mode you can enter the following sequence 9 9 Le 2 When the master code is forgotten 1 Wire a push button or replicate with wire link across the Egress terminal and GND 2 Switch off power for 1 minute 3 Switch ON power 4 during the first 60 seconds press the EG button once to enable the function 5 Enter the following code s o s o FIL The keypad should now be in programming mode ready to accept new data Using the keypad Using the standard codes O
5. Installation amp User Manual For 605 DECT 2 4G Intercom Heli EEIE BIEI ws Wireless Video Intercom System Models 605AB 605ABK AES Advanced Electronic Solutions Page 1 Page 2 Contents Overview of system Site Survey Mounting the Transmitter Power supply Mounting Architectural Panels Mounting Hooded Panels Mounting Flush Panels Wiring Code Lock Keypad Connections Wiring Tips Keypad Overview Basic Keypad Programming Full Keypad programming Using the Keypad The Handset Recoding Adding a Handset Testing Using the Intercom Handset Maintenance of the Intercom Troubleshooting Overview of System Please read this entire manual before attempting to install this system This system should only be installed by a professional automatic gate installer or access control specialist installer It is recommended that the system be range tested on site BEFORE being fully installed Site Survey Before installing this system you need to be sure that the range of the system will be sufficient The transmitter and speech unit can be powered up call button pressed and then check that the handset will ring from all areas in which it will be used X Z Antenna Antenna Intercom Y Intercom Tip For longer range installations locate the handset close to the front of the property near a window if possible Concrete walls can reduce the open air range of 350 metres by 30
6. Messages 4 Bell 5 Colour ZN 2 1 Brightness Adjusts screen brightness 2 Language Select English French or German 3 Messages Listen to or delete saved or older voicemails press KEY to delete any message 4 Bell Change ring tone 5 Colour Increase or decrease screen colour Use up and down arrows to navigate and OK to select an option Press right arrow to exit Optional Audio Handset The audio handset should be charged for 8 hours before use It is recommended to give it at least 1 hour charge before range testing Change Ring Volume oat Press Aand y to increase Voicemail and decrease ring volume Symbol and press MENU to save Reception Voicemail indicator When a call is not answered within 40 seconds the visitor can leave a message Once ON OFF complete the handset will display the symbol The unit can store up to 16 messages energia base nio Change Ring Tone Press S and the handset will ring with its currently selected tone PressA and V to cycle code through available ring tones Button and press MENU to select and save To listen to voicemail press MENU to play If there are more than 1 message press A and Y to select the message required and press MENU to play Delete Long press delete all Page 10 Using the Audio Handset e Yal fac 12 21 D Open door gate Answer end call Change ring tone
7. ll appears contact your dealer for service Page 13 Page 14 Page 15 AES Advanced Electronic Solutions Page 16
8. nce you have exited out of programming mode simply enter the user code Using super user codes 2 1 Activate output 1 ALIE EIEE Activate output 2 2 2 3 Activate output 3 Page 8 The Video Handset The handset should be charged for 8 hours before use It is recommended to give it at least 1 hour charge before range testing y Microphone Monitoring button i Door Gate release button Answer End Call Adjust speaker ring tone volume Answering Calls 1 When the intercom calls identify the visitor on the screen 40 80 m und 2 Press the OK button to answer the call 3 Speak clearly into the top of the handset at a distance of 10 20cm 4 During the call press lt or gt to increase or decrease volume 5 Press to activate door or gate release and press OK to end the call Note The video will remain active for 1 minute after the audio call is ended Page 9 New Voicemail The handset will store up to 16 voicemails if missed callers decide to leave a message at the door gate unit Press OK button to listen to a new voicemails Settings The following settings can be changed in the system To make any of the following settings put the system into monitoring mode by pressing and holding the key for a few seconds Press and hold for 3 seconds 1 Brightness 2 Language 3
9. stainless steel can dull or discolour over time in weather conditions or in winter if exposed to road salt This can be polished with a suitable stainless steel cleaner or re brushed with an abrasive pad or sand paper observing the directionality of the grain Take care when cleaning the acrylic face This should be gently wiped with a soft damp cloth to prevent scratching Page 12 Troubleshooting guide Q The unit will not ring the handset A Try re coding the handset and transmitter as per instructions Check push button wiring to the transmitter with multi meter Check power cable distance from power adaptor to transmitter is less than 4 metres Q The person on the handset can hear interference on the call A Check cable distance between the speech unit and transmitter Shorten this if possible Check cable used between the speech unit and transmitter is screened CAT5 Check that the screen of the CAT5 is connected to ground in the transmitter as per wiring instructions Q Keypad code not operating the gate or door A Check if the corresponding relay indicator light comes on If it does then the fault is either a power problem with excessive cable run or wiring If the relay can be heard clicking then it is a wiring problem If a click cannot be heard then it is likely a power problem If the light does not activate and the keypad emits an error tone then the issue is likely a programming error Q My handset will no
10. t recode Try the process again If it still does not work delete the code from the transmitter To delete code press the code button for 3 seconds and release Then press it 7 times after which a tone should be heard Then press another 7 times Now try re coding the handset again as per the procedure Q Range problem Handset works beside the intercom but not from inside the building A Check that the power cable to the transmitter is within guidelines and is heavy enough gauge Insufficient power cabling will reduce transmission power Check that there are not excessive objects blocking the signal like large dense shrubs vehicles foil lined wall insulation etc Try to achieve line of sight between both devices Q No speech in either direction A Check CAT5 wiring between speech panel and transmitter Disconnect re strip cables and re connect again Q Handset will not charge A Try replacing both batteries with equivalent Ni Mh batteries firstly It is possible to have a dead cell in a battery which can prevent both batteries from charging Check for contamination or grease on the charging pins at the base of the handset gently scratch with screwdriver or wire wool Q The unit will not power up there is a short circuit on the power supply A This can be caused by the inbuilt surge protection being short circuited due to a surge over voltage or wiring fault Disconnect all wiring check and re wire again If the fault sti
11. ule for exit button eNO time control Optional 8 NC Push to Halcom Sov Seperate Exit le wo 12V a c or d c lock PSU Note The manufacturer can only support the use operation and functionality of the intercom and keypad themselves Professional wiring to door release or automatic gate systems is the responsibility of the installer Please consult a security integrator for further support Advanced Keypad Connections INT Lock Advanced connections O P1 inhib INT Lock Used to operate a door in conjunction with Sense another keypad 24v dc max voltage 100mA sink GND O P1 inhib When closed this disables all codes for relay group 1 Sense N C connected to GND to be connected to N C door contact Can be used to generate door open or tamper alarm Ierde DU out switches to ground after the Duress Code is From power i supply entered Used to trigger alarm zone or buzzer to notify guard 100mA sink 24VDC OUT OUT2 K or A Not used Keypad overview This keypad has 3 outputs The diagram below shows the LED indicators which indicate programming and relay status information ON when incorrect codes entered and outputs are locked out GREEN when output 1 activated RED when output 2 activated JULLI FAST FLASHING Wrong code entered error L SLOW FLASHING in normal standby mode L_ ON in programming mode L ON when relay 3 activated TIP After power up as a sec
12. urity precaution the keypad cannot be programmed for 60 seconds Once this time elapses you may begin TIP Flashing amber LED is normal standby mode Basic Keypad Programming Quick start guide Tip The engineer code 1 Enter programming mode amber LED should be ON must be the same length as 9 o 9 o Ml C user codes So if using a 6 2 Enter a new user code digit engineers code then 1 0 2 0 o0 o0 gt gt gt gt user codes must also be 6 digits long etc 3 Exit programming mode JE 4 Enter the new user code to check the relay clicks Page 6 Full Keypad programming E i i nter programming mode The unit is now in programming mode Amber LED on the o o o o keypad should remain permanently on 0000 is the default programming passcode Exit programming mode The unit should exit programming mode and the amber LED should start flashing again Enter a new ENGINEERS code Go into programming mode firstly then enter the following sequence o Replace with your new ENGINEERS Location 4 8 digit code Validate code Enter or delete new user codes There are 3 groups of user codes Group 10 for relay 1 group 20 for relay 2 and group 30 for relay 3 The programming sequence is shown below 1 o 2 Je III Ra mn 10 relay 1 codes 2 add code Memory locations 1000 available 5 delete code 000 99