1. e Vibrant color screen displays easy arena ihe cls l l to read real time graphs status and Display Languages Available English French Spanish Polish German Italian Dutch Danish analysis results Contents Fyrite INSIGHT Plus instrument comes with probe spare filters protective rubber boot 4 AA batteries user manual and User diagnostics hard carrying case Ee iat Fyrite INSIGHT Plus w Reporting Pkg Kit instrument comes g 0 Sensor life indication with probe spare filters protective rubber boot IrDA printer USB e Calibration reminders cable Fyrite User Software 8 AA batteries hard carrying case Reporting package optional e Customize test reports with your 4 onnan loan Fyrite INSIGHT Plus Ordering Information pany 0g s aeaa anit fuels 0024 8515 Fyrite INSIGHT Plus oltware updates 0024 8517 Fyrite INSIGHT Plus with Long Life 02 sensor _Pre calibrated B Smart CO sensor 0024 8516 Fyrite INSIGHT Plus w Reporting Pkg Kit with integral NOx filter 0024 8518 Fyrite INSIGHT Plus w Reporting Pkg Kit with Long Life 02 sensor gt NSIGHT Plus with Tune Rite softw lv availabl Manual Zero Auto Zero CO feature Nae ite software is only available on Tune Rite On Demand HVAC Assistant High CO Shut Off Protection feature Fyrite INSIGHT Plus Accessories 2 year or 3 year 02 sensor warranty n a 0024 1492 Fyrite INSIGHT Plus Reporting K
2. Ce Combustion Analyzers ntial Combustion Analyzer te ide pyrite INSIGHT Plus Features amp Benefits Includes exclusive Tune Rite On Demand HVAC Assistant e Vibrant full color display shows easy to read real time analysis e Fast and accurate 02 CO 0 4 000 ppm I stack air temperature and draft pressure measurements e 9 pre programmed user selectable fuels 2 custom e Print stored data 100 records and data download via USB with Fyrite User Software qHold Nat Gas 353 349 SRCE 356 353 Clear Menu i Setup Menu POWERED BY Post purge Period i june ie CO Zero Setting SOFTWARE As easy as 1 2 3 Select fuel type select O2 Sensor Type appliance type and then start analysis The Fyrite INSIGHT Plus is Bacharach s premium residential and light commercial combustion analyzer This American made analyzer uses advanced technology to accurately measure analyze and report results that validate safe operation efficiently tune older systems and save customers money Powered by innovative Tune Rite software the industry s first ever on demand HVAC assistant it helps both new and seasoned technicians save money by making more thorough and efficient service calls Featuring industry exclusive B Smart CO sensor technology it enables technicians and HVAC R service representatives to install pre calibrated sensors right in the field to avoid costly downti
3. es for the equipment under optimum conditions Based on the appliance type Tune Rite helps you to determine if it s operating safely and in the acceptable ranges If not you ll get a list of possible causes related to the readings and an easy to navigate troubleshooting checklist Combustion analysis should be performed only after combustion Tune Rite tells you the optimum parameters indicate that the appliance has reached steady state time to begin the analysis operating conditions Steady state can be gauged by three things VY The change in temperature of combustion products in the vent system Y The change in the percentage of oxygen in the flue gas mix which assists in determining if there is excess air or excess fuel in the combustion process v The change in Carbon Monoxide CO over time CO levels will spike during the initial fire which is normal but they Tune Rite chow a aa should normalize to a lower output as steady state is reached data at steady state so adjustments can be made to optimize appliance performance lf a steady state is not reached the equipment may require major tuning repairs or replacement Tune Rite helps service technicians to start the analysis at the optimum time yielding more accurate readings and an effective diagnosis Once this stable condition is reached combustion analysis can be performed The Benefits Of Tune Rite Technology Tune Rite software eliminate
4. g that was done during the service call Using your saved As Found and As Left readings Tune Rite generates a comprehensive leave behind service report showing the homeowner what was inspected adjusted or repaired Fyrite INSIGHT Plus Specifications 9 User Selectable Fuels Natural Gas Oil 2 Oil 4 Oil 6 Propane Coal Wood Kerosene B5 2 custom Measurement Ranges Combustion Air Ambient Air 4 to 600 F 20 to 316 C Temperature Flue Gas Temperature 4 to 1 202 F 20 to 650 C Oxygen 0 0 0 to 20 9 Carbon Monoxide CO 0 to 4 000 ppm Draft Differential Pressure 40 to 40 INWC 100 mBar Fyrite INSIGHT Plus Calculated Ranges Combustion Efficiency 0 1 to 100 i Carbon Dioxide C0 0 1 to a fuel dependent max Features amp Benefits value in percent 5 l Carbon Monoxide air free 0 to 9 999 ppm Five tools in ONE o Excess Air 0 to 250 S Combustion and efficiency analyzer Dimensions 8 0 H x 3 6 W x 2 3 D 20 3 cm x 9 1 cm x 5 8 cm e Room air CO test instrument Weight 16 oz with batteries 0 45 kg e Flue gas CO tester Power 4 AA Alkaline batteries incl Universal power adapter or USB cable e Dual channel digital thermometer Minimum of 15 hours typical battery life gt Digital manometer Warranty Instrument and sensors 2 years 2 year warranty on 0 sensor Long life 0 sensor carries a 3 year warrant Full Color Graphic LCD display eee m a pa
5. it with IrDA printer USB cable amp software i 0024 1400 IrDA Printer w Disposable AA Batteries and Magnet 0024 1310 Printer Paper 5 rolls t 0024 1611 Universal AC Power Adapter 0104 1797 Thermocouple 10 ft combustion at temp 0104 1798 Thermocouple 1 in ambient air temp 0024 8242 Differential Pressure amp Temperature Kit 0024 1591 Long Life 02 Replacement Sensor 0024 1593 CO Sensor not calibrated 0024 1616 B Smart CO Sensor pre calibrated 0024 8257 Long Life 02 Sensor Upgrade Kit B MARI SENS OAMRnR S The B Smart Sensor Exchange Program allows users to replace pre calibrated sensors in the field eliminating the need to send the instrument in for calibration With the B Smart Sensor Exchange Program you receive factory calibrated sensors just plug them in and continue to use your instrument there s no down time and it saves time and money ALA PO 7 UL BACHARACH The Measurable Difference Fyrite INSIGHT Plus B Smart and Bacharach are registered trademarks of Bacharach Inc 2012 Bacharach Inc all rights reserved All information is subject to verification sane MADE IN THE USA July 2014 REV 0 Printed in U S A
6. me and inconvenience Five Tools in ONE with Real Time Analysis The Fyrite INSIGHT Plus is a five in one steady state combustion analyzer that is capable of measuring flue gas and room air CO and can also function as a dual channel digital thermometer up to 999 F and a digital manometer which measures draft gas pressure ESP and up to 40 INWC 1 800 736 4666 724 334 5000 www MyBacharach com help MyBacharach com An Industry Innovation Introducing Tune Rite A technological first Tune Rite is an on demand assistant that will help you save money and win customer loyalty by documenting more thorough and efficient service calls with fewer callbacks Tune Rite is geared for residential appliance checks including natural gas furnaces hot water heaters and oil boilers At the touch of a button the software monitors the combustion analysis process in real time to VY Deliver the most accurate analysis every time v Make instant troubleshooting suggestions v Provide guidance based on live data plus typical characteristics of the combustion appliance Steady State and Tune Rite Why It Matters As it evaluates the flue gas Tune Rite s full color graphic display shows you when the appliance has reached steady state which Is critical for consistent repeatable and accurate combustion testing Measured values of oxygen stack temperature and carbon monoxide are compared to typical valu
7. row down the potential causes of a problem Tune Using color coded arrows Rite software Tune Rite shows which readings are Tune Rite Results in range green unstable yellow or recommends r out of range red possible causes Overfired a measurements EEN and it will hehehe i keal display a prioritized list of most likely potential issues to Filter __ H investigate A drill down into a checklist helps to keep List Menu Analyze track and record what has been inspected adjusted repaired or found to be an Issue Burner Dirty Burner F Generate Credible Comprehensive Service Reports goi Al Flame Impingement With today s informed homeowner the importance of proof of Burner Debris service is critical for customer trust and loyalty Homeowners z may be skeptical until they see a detailed service record Using As Found readings Tune Rite narrows down taken before you ve potential causes when performed any service analysis readings fall beyond and then recording the AOAIE Tangas As Left readings clearly documents the results of the adjustments or repairs that you ve made e Tune Rite helps you do that with easy to store data along with a checklist of issues that you have reviewed and possibly corrected Stored records can be printed immediately as a comprehensive account of your work which presents a professional and credible record of everythin
8. s the guesswork commonly involved in determining steady state by showing you a live graphical representation of all combustion parameters as they settle into a steady state condition When the combustion equipment reaches steady state a red dot displayed on the LED readout changes to green and is ready for analysis It s that simple At a glance steady state indicators red or green What Readings Should You See During Testing The simple answer is it s not simple Measured values of oxygen stack temperature and carbon monoxide vary depending on the heating equipment and fuel type Even seasoned pros find it challenging to keep up with combustion guidelines for all possible equipment types and manufacturers Sometimes furnace or boiler manufacturers will detail the optimum ranges in their installation manual however tracking down the information can be difficult Fortunately Bacharach has done the homework and programmed into the Tune Rite software typical ranges for these parameters based on the fuel and equipment type Those ranges can be seen in an easy to read bar graph format along with the current values Green red and yellow indicators show whether the readings are in range green out Run Nat Gas of range red or unstable yellow What If The Readings Are Out Of Range Combustion analysis results that are not in the expected ranges indicate there is a problem Depending on the readings it is possible to nar
Download Pdf Manuals
Related Search
Related Contents
bio controller adi 1030 Lyngdorf Audio Millenium ADC Analog/Digital Converter CD Player User Manual 東芝ハードディスクカメラ取扱説明書 Elo Touch Solution E287348 touch screen monitor SmartMetals 012.2101 井上産業 - 震災廃棄物資源化設備・女川町津波被災状況・ガレキ(がれき 重要説明事項 Seguridad con los montacargas here Samsung A / No Frost Copyright © All rights reserved.