Home

Experiment 6: Detection with the Decision Maker

image

Contents

1. Figure 5 details of the macro CHANNEL MODEL module Signal regeneration First patch up the complete system according to the block diagram of Figure 3 shown modelled in Figure 4 Note that for selecting the best sampling instant the eye pattern is preferred The oscilloscope is triggered externally by the bit clock see experiment 5 To check visually that the recovered sequence is error free you need the snapshot The oscilloscope is triggered externally by the SYNC pulse of the SEQUENCE GENERATOR see experiment 5 Ideally for visual evaluation the first of these requires a long sequence and the second a short sequence For convenience however you may find it acceptable to use short sequence for both observations TI before plugging in the SEQUENCE GENERATOR module select the minimum length sequence with the on board switch SW2 both toggles UP T2 model the complete system illustrated in Figure 4 except for the DECISION MAKER T3 set the AUDIO OSCILLATOR to about 2 kHz This will suit the DECISION MAKER which has been designed for operation with clock rates of this order T4 ensure the oscilloscope is triggering on the SYNC signal from the SEQUENCE GENERATOR Check the sequence on CH1 A Using the COMPARATOR T5 set the TUNEABLE LPF to its widest bandwidth select a mid range gain for the TLPF using the GAIN knob Check the signal on CH1 B is roughly of the same shape as shown in Figure 1 The COMPARATOR should
2. Using the DECISION MAKER T8 read about the DECISION MAKER module in the TIMS User Manual Before plugging it in ensure that a the on board switch SW2 is switched to INT b the NRZ L waveform is selected with on board switch SWI upper rear of board This configures the DECISION MAKER to accept bipolar non return to zero waveforms as you have from the analog output of the SEQUENCE GENERATOR T9 to display an eye diagram trigger on the CLK input of the SEQUENCE GENERATOR TTL output of AUDIO OSCILLATOR for the oscilloscope and connect channel I to the output of the OUTPUT ADDER which will be the input to the DECISION MAKER module in T10 Adjust the oscilloscope to display an eye pattern you may wish to change the AUDIO OSCILLATOR frequency to 8kHz and select a time scale of about 10 micro seconds to see a better eye pattern on the T2445 oscilloscope if using digital oscilloscope connect channel 2 to the BNC output of the decision maker and look at the pulse train and then wind it back to 2kHz and change the time scale appropriately if finding it difficult further on you may wish to try SkHz again and setup the system for that and then go back to 2kHz with minor adjustments T10 patch the DECISION MAKER into the system including the Z MOD connection to the oscilloscope on the back panel of the T2445 If using the Digital oscilloscope connect channel 2 to the BNC output Z MOD output of the DECISION MAKER card T11 rota
3. levels Some mention was made above in T7 about the signal levels at some of the interfaces especially that of the gain of the TLPF and the amplitude of the signal relative to the noise we were using the largest noise sources possible at the input to the COMPARATOR You should be experienced enough now to realise how important these are Although this may seem to be a digital style experiment most of the modules are processing analog level signals So the signal levels at their yellow interfaces should be adjusted appropriately That is they should be at about the TIMS ANALOG REFERENCE LEVEL or 4 volt peak to peak Check back that this was achieved DC threshold In T7 you should also have investigated the purpose of the DC threshold adjustment provided in the CHANNEL MODEL You probably did this by slowly reducing the channel output amplitude whilst monitoring the COMPARATOR output Eventually as the signal amplitude is progressively decreased the COMPARATOR output will be all HI or all LO Fine adjustment of the DC level from the channel as suggested in T7 you may have done this by setting the gain g of the OUTPUT ADDER to some small finite value and used the VARIABLE DC front panel control to adjust the voltage so its centred around 0O Volts allowing for a finer adjustment will re position the sequence with respect to the COMPARATOR reference level nominally zero or ground and allow operation for even smaller input levels
4. Experiment 6 Detection with the Decision Maker Modified by Dr Peter Vial from original Emona TIMS lab in Volume D1 ACHIEVEMENTS familiarisation with the DECISION MAKER module to be used in later experiments Demonstration of the superiority of a gated detector compared with a simple comparator PREREQUISTES familiarity with the SEQUENCE GENERATOR and eye patterns experiment 5 completion of the experiment entitled PRBS generation experiment 3 EXTRA MODULES DECISION MAKER Preparation The shape of a binary sequence waveform is affected by transmission through a noisy bandlimited channel Since the aim of a transmission system is to deliver a perfect copy of the input to the output the received sequence needs to be restored to its original shape or regenerated The regeneration process is performed by what we will call a detector You should refer to your text book to see the wide range of circuits which has been devised for performing this regeneration process from the simple amplitude limiter or the comparator to extremely sophisticated and intelligent schemes see Tutorial Question 3 As an example of moderate wave shaping refer to Figure 1 which shows the waveshape changes suffered by a sequence after passage through a bandlimited channel BIPOLAR INPUT SEQUENCE BANDLIMITED OUTPUT SEQUENCE showing delay el LIL pitcrock Figure 1 waveforms before and after moderate bandlim
5. estore the bit width of the regenerated sequence This and more has been done with the TIMS DECISION MAKER The DECISION MAKER is fed a copy of the corrupted sequence and also a copy of the bit clock It examines the incoming sequence at a specified instant within each bit period This best sampling instant may be chosen by you after inspection of the eye pattern With additional external circuitry this could be automated or made adaptive The DECISION MAKER makes its decision at the instant you have specified within each bit period and outputs either a HI or a LO It makes each HI or LO last for a bit period It also outputs a new bit clock shifted in time relative to the input bit clock so that the new clock is aligned with the regenerated bit stream The sampling instant specified by you in this experiment is set by a front panel control and is indicated on the oscilloscope waveform by a high intensity spot or a shadowed spot when using one of the two T2445 Tektronics CROs or a series of short duration pulses from the digital Tektronics CROs The appropriate waveform to be viewing when selecting the sampling instant is the eye pattern For more details about the DECISION MAKER module refer to the TIMS User Manual You will have an opportunity to become acquainted with it in this experiment Please note that the circuitry of the DECISION MAKER has been optimised for a clock rate in the region of 2 kHz so it is unwise to use it a
6. have no trouble regenerating this sequence T6 check the COMPARATOR output against the original sequence by looking at CH1I A and CH2 A simultaneously Satisfy yourself that regeneration is acceptable T7 now carry out some observations of the COMPARATOR output as either or both the channel bandwidth is varied and noise is added Get some appreciation of the limitations of the COMPARATOR as a regenerator The best way to do this is to change the gain of the TLPF while still set on largest bandwidth so that you drop the gain to the point where errors are occurring at the output This also means keeping a close look at the DC offset coming from the noise see DC threshold below The noise generator module should be on maximum noise setting 22dB and the g input of the INPUT ADDER set to maximum fully clockwise Observe the effect as you drop the gain down to the point where errors start to occur at the output of the COMPARATOR Try using the RUN STOP button on the Digital Oscilloscope to compare the output of the COMPARATOR and the input bit stream At the point where there are no errors being made then start lowering the bandwidth of the TLPF and observe the effect of bandlimiting the channel Repeat for when some errors are occurring when the filter is on the widest bandwidth Repeat again for larger gains on the TLPF Keep an eye on the DC offsets to ensure that the system is not suffering from drift see DC threshold below Signal
7. ill of course be a time offset between the two due to the delay introduced by the filter and the regeneration process itself Note that the DECISION MAKER provides a new bit clock aligned with the regenerated sequence This is essential for later processing of the regenerated sequence eg by the error counter see later You will now make some more demanding tests of the DECISION MAKER Changing from one display to the other involves a little more than changing the connection to the ext trig of the oscilloscope as generally the sweep speed needs some slight adjustment Ideally also the snapshot needs a short sequence and the eye a long sequence But for these tests a short sequence should be acceptable for both What you will have to do each time you make a test is 1 lower the bandwidth a little 2 re position the sampling instant 3 check the sequences for equality You can develop your own visual scheme for comparing sequences T15 now carry out some observations of the DECISION MAKER output as you did for the COMPARATOR output as either or both the channel bandwidth is varied and noise is added T16 Get some idea of the performance of the DECISION MAKER as compared with that of the simple COMPARATOR as a regenerator To do this connect both devices back into the system Do the comparison at 2kHz adjust the system so that the output of the COMPARATOR starts to make mistakes with widest bandwidth from the TLPF and adjust
8. in via the eye pattern how these affect the satisfactory operation of the detection device hint look at the introduction for experiment 4 on line coding under why line coding Q3 in this experiment we use a stolen clock to generate the strobe clock at the receiver Refer to your text book and describe the essence of a clock recovery process in a commercial application
9. iting If the bandlimited bipolar output waveform of Figure 1 is connected to a comparator whose reference is zero volts then the output will be HI say V volt whilst the waveform is above zero volts and LO say V volt when it is below Visual inspection leads us to believe that it is unlikely the comparator would make any mistakes Examination of the eye pattern of the same waveform would confirm this If there was noise and perhaps further bandlimiting the comparator would eventually start to fail But other more sophisticated circuits operating on the same waveform might still succeed in regenerating a perfect copy of the original To be fair to the comparator it is competent to decide whether the signal is above a HI or below a LO a reference Provided the signal to noise ratio SNR is not too low then this will be during the HI and LO bits As the SNR reduces the comparator output may not match favourably the input especially as regards pulse width Finally its performance as a detector will deteriorate and extra pulses or bits will appear as indicated in Figure 2 below But note that it is still operating faithfully as a comparator message INPUT bandlimited and delayed message bandlimited yt message PLUS noise comparator OUTPUT 4 waveform 3 as input Figure 2 deterioration of comparator output with noise Additional circuitry using the bit clock as a guide could be implemented to r
10. t clock rates too far removed from this EXPERIMENT You will examine the decision process applied to a noisy bandlimited bipolar waveform using two methods a basic COMPARATOR ungated and the TIMS DECISION MAKER module In later experiments you will count actual errors but in this experiment evaluation will be by visual comparison of the device output and the original sequence The test signal The test signal will come from a SEQUENCE GENERATOR via a noisy bandlimited channel The bandlimiting of the channel will be adjustable This is illustrated in block form in Figure 3 below SEQUENCE h yF GENERATOR DECISION q rm J MAKER sequence out NOISY CHANNEL COMPARATOR Wu clock Figure 3 system to demonstrate sequence regeneration A model of the block diagram of Figure 3 is shown in Figure 4 below It uses the macro CHANNEL MODEL module from experiment 2 ext trig CHANNEL MODEL 3 iee Mii select filter Figure 4 the COMPARATOR and DECISION MAKER as regenerators The macro CHANNEL MODEL module was introduced in the experiment entitled The noisy channel model experiment 2 from Emona TIMS Volume D1 It is used for inserting noise bandlimiting and adjusting signal levels As a reminder the model is reproduced here as Figure 5 To provide an adjustable bandwidth it uses the TUNEABLE LPF as the bandlimiting module INPUT and OUTPUT and noise level DC threshold adjust adjust
11. te the front panel DECISION POINT control knob of the DECISION MAKER There should be a highlighted point moving across both oscilloscope traces or in the case of the pulse train on channel 2 for the digital oscilloscope you should see the pulses move in time position or phase relative to channel 1 If the dark spot actually a dark line cannot be seen using the T2445 oscilloscope only try varying the oscilloscope intensity control If still no dark spot seek help from your Laboratory demonstrator As a last resort refer to the TIMS User Manual and the oscilloscope User Manual There are settings on the DECISION MAKER circuit board to suit most oscilloscopes and once set by the Laboratory Manager they require no further adjustment You should ideally do this at 2kHz but you may also try 8kHz as long as you return to 2kHz by step T12 note make sure a TTL bit clock is connected to B CLK in T12 locate the high intensity dark spot on the oscilloscope display if using the T2445 or the relative location of the train of pulses from the Z MOD output on the DECISION MAKER if using the digital Oscilloscope This shows the sampling instant T13 adjust the front panel control of the DECISION MAKER so that the sampling instant is positioned at the best decision point within the bit period ie where the vertical eye opening is greatest T14 the regenerated sequence will be displayed on CH2 B Compare it with the input sequence on CH1 A There w
12. the gain of the TLPF now have a look at the output of the DECISION MAKER You should probably observe that the DECISION MAKER is still not providing quite as many errors as the COMPARATOR Why do you think that this is the case Think about how often the COMPARATOR makes a decision compared to the DECISION MAKER per bit period see Tutorial Question 1 T17 Try lowering the bandwidth of the system by changing the TUNE knob of the TLPF and compare the two techniques Error counting During the above observations you may have been saying there must be a better way to judge performance And of course there is A visual check for errors provides a quick method for comparing short sequences but it is a qualitative check only something quantitative is then required for serious measurements More systematic methods are introduced in the experiment entitled BER measurement in the noisy channel in Volume D2 Further and Advanced Digital Experiments which is experiment 7 Summing up The DECISION MAKER module will be used in many more experiments so it is important to have a good understanding of its capabilities and limitations Make sure you read its data sheet TUTORIAL Questions Q1 explain why a strobed decision process can be expected to result in a lower incidence of errors compared to an ungated instantaneous comparator see T16 Q2 familiarize yourself with the terms timing jitter and baseline wander Expla

Download Pdf Manuals

image

Related Search

Related Contents

badge gabie - Inforisque.info  Descripción del Curso Aastra MX-ONE™ Version 4.x Telephony  取扱説明書 - 日立工機  Machine d`enfournement automatique  Manuale di utilizzo  livret d`accueil V3x - Site d`aide de l`offre SPIP établissement  gr  cd mp3 board  

Copyright © All rights reserved.
Failed to retrieve file