Home
LPC2 TH1 User Manual
Contents
1. SMARTEH LIVING SYSTEMS USER MANUAL Longo programmable controller LPC 2 TH1 module Version 2 SMARTEH d o o Trg tigrovcev I 5220 Tolmin Slovenia Tel 386 0 388 44 00 e mail info smarteh si www smarteh si a LONGO programmable controller LPC 2 TH1 module SMARTEH LIVING SYSTEMS Written by SMARTEH d 0 0 Copyright 2012 SMARTEH d o o User Manual Document Version 002 July 1 2012 a LONGO programmable controller LPC 2 TH1 module SMARTEH LIVING SYSTEMS STANDARDS AND PROVISIONS Standards recommendations regulations and provisions of the country in which the devices will operate must be considered while planning and setting up electrical devices Work on 230 VAC network is allowed for authorized personnel only DANGER WARNINGS Devices or modules must be protected from moisture dirt and damage during transport storing and operation WARRANTY CONDITIONS For all modules LONGO LPC 2 if no modifications are performed upon and are correctly connected by authorized personnel in consideration of maximum allowed connecting power we offer warranty for 24 months from date of sale to end buyer In case of claims within warranty time which are based on material malfunctions the producer offers free replacement The method of return of malfunctioned module together with description can be arranged with our authorized representative Warranty does not include damage
2. Set Weel ARS NE 3 4 INSTALLATION none nen ee neneneeneneneenenvenenvenenenennenvensnvenvenvenven den denden 4 4 1 Connection scheme example 4 4 2 Mounting frame selection nennen nenn nennen nenn nennen nennen nenn 7 2 3 MOUNEING STIAN 8 4A Module AN Lee 9 gt TECHNICAL SPECIFICATION S anna 10 NNN 11 NOT er an a Ran 12 race a Longo programmable controller LPC 2 TH1 module SMARTEH 1 DESCRIPTION LPC 2 TH1 module is used for room temperature and relative humidity measurement Module is equipped with temperature and humidity sensor All parameters are accessible on module communication port When panel is connected to the LPC 2 main control unit MCU parameters can be viewed with LPC Manager application 2 FEATURES Figure 1 LPC 2 TH1 module Table 1 Technical data Room temperature measurement Room relative humidity measurement Power LED Internal fault LED 3 OPERATION 3 1 Parameters Actual temperature Represent actual room temperature measured by LPC 2 TH1 module in C Actual room temperature value 40 00 123 80 C is represented as 4000 12380 number in MCU module Actual humidity Represent actual room relative humidity measured by LPC 2 TH1 module in Actual room relative humidity value 0 100 is represented as O 100 number in MCU module a LONGO programmable controller LPC 2 TH1 module 4 INSTALLATION 4 1 Connection scheme example Figure 2 Connection
3. 1 module sample LPC 2 TH1 P N 225VV110V01001 S N TH1 S9 1000000190 D C 39 10 Label 1 description 1 LPC 2 TH1 is the full product name 2 P N 225TH110V01001 is the part number 225 general code for LPC 2 product family TH1 short product name LOVOl1 sequence code 10 year of code opening VO1 derivation code 001 version code reserved for future HW and or SW firmware upgrades 3 D C 39 10 is the date code 39 week and 10 year of production Label 2 description 1 S N TH1 S9 1000000190 is the serial number TH1 short product name S9 user code test procedure e g Smarteh person xxx 1000000190 year and current stack code 10 year last two cyphers 00000190 current stack number previous module would have the stack number 00000189 and the next one 00000191 race Longo programmable controller LPC 2 TH1 module SMARTTEH LIVING SYSTEMS 5 TECHNICAL SPECIFICATIONS Table 5 Technical specifications Power supply from MCU Interconnection connector type RJ12 6 6 Power consumption 0 5 W Temperature measurement accuracy at 25 C 0 3 Temperature measurement accuracy on the R a 1 scale value 0 50 C Temperature measurement accuracy on the full 2 5 scale value 40 123 C Relative humidity measurement accuracy on the 3 scale 20 80 Relative humidity measurement accuracy on the 5 full scale va
4. C 2 TH1 module SMARTEH LIVING SYSTEMS 4 3 Mounting instructions Figure 3 Housing dimensions e Dimensions in millimeters All connections module attachments and assembling must be done while module is not connected to the main power supply Module should be positioned in the wall inside of the room Avoid direct sunlight or positioning near heating cooling source object Recommended installation height is 1 5 m above floor level Set the correct RS485 address S1 switch for LPC 2 TH1 refer to the Table 4 Connect interconnection cable to the connector Kl Max allowed tensile force Is 30N 3 Put the LPC 2 TH1 in mounting frames 4 Cover LPC 2 TH1 with cover plate LPC 2 TH1 is connected to the main control unit with interconnection cable e g SSK 7 which must be ordered together with LPC 2 TH1 module When more modules e g LPC 2 CR1 LPC 2 CH1 LPC 2 DP2 or up to four LPC 2 DP1 are connected to main control unit splitter e g SPL 2 is also required Figure 2 Module address on RS485 network is set with DIP switch on the back of the module Table 4 e NOTE Signal wires must be installed separately from power and high voltage wires in accordance with general industry electrical installation standard Longo programmable controller LPC 2 TH1 module SMARTEH LIVING SYSTEMS 4 4 Module labeling Figure 4 Labels on housing Label 1 LPC 2 TH1 module sample Label 2 LPC 2 TH
5. due to transport or because of unconsidered corresponding regulations of the country where the module is installed This device must be connected properly by the provided connection scheme in this manual Misconnections may result in device damage fire or personal injury Hazardous voltage in the device can cause electric shock and may result in personal injury or death NEVER SERVICE THIS PRODUCT YOURSELF This device must not be installed in the systems critical for life e 9 medical devices aircrafts etc If the device is used in a manner not specified by the manufacturer the degree of protection provided by the equipment may be impaired gt Waste electrical and electronic equipment WEEE must be collected separately LONGO LPC 2 complies to the following standards e EMC EN 61000 6 2 EN 50082 EN 61000 6 4 EN 50081 e LVD IEC 61131 2 e Vibrations and climatic mechanical EN 60068 2 6 EN 60068 2 27 EN 60068 2 29 Smarteh d o o operates a policy of continuous development Therefore we reserve the right to make changes and improvements to any of the products described in this manual without any prior notice MANUFACTURER SMARTEH d o0 0 Trg tigrovcev 1 5220 Tolmin Slovenia 5 Longo programmable controller LPC 2 TH1 module SMARTEH LIVING SYSTEMS Index Longo programmable controller LPC 2 THl module 1 DESCRIP HON rave nen ae en nenne era nee een 1 2 FEATURE a ae tn ER 2 SER IN 3
6. lue 0 100 Dimensions W x H x D 65x47 x 25 mm Weight 359 Maximum altitude 2000 m Mounting position all directions Ambient temperature 0 to 50 C Ambient humidity max 95 no condensation Transport and storage temperature 20 to 60 C Protection class IP 20 Longo programmable controller LPC 2 TH1 module SMART EH LIVING SYSTEMS 6 CHANGES The following table describes all the changes to the document Date V Description 1 7 2012 002 CGP General update The initial version issued as LPC 2 TH1 temperature and 30 09 2010 001 relative humidity module UserManual 3 mg LONGO programmable controller LPC 2 TH1 module SMARTEH LIVING SYSTEMS 7 NOTES
7. scheme example SMARTTEH LIVING SYSTEMS Future use PO1V ID1V TH1V LED2 3 BL on Du ox Longo programmable controller LPC 2 TH1 module Table 2 K1 SMARTEH LIVING SYSTEMS K1 1 GND Ground K1 2 7 28 VDC Power supply input K1 3 Standard RS485 A Data receive send line A K1 4 Standard RS485 B Data receive send line B Table 3 LEDs Green LED indicates TH1 power On OK LED supply Off No power supply LED2 Red LED indicates TH1 state On RS485 communication fault Off RS485 communication OK Table 4 S1 RS485 ADDRESS Switch 1 Switch 2 0 OFF OFF 1 OFF ON 2 ON OFF 3 ON ON re 3 Longo programmable controller LPC 2 TH1 module SMARTEH LIVING SYSTEMS 4 2 Mounting frame selection Smarteh has verified following lines to be compatible with LPC 2 DP1 module Bticino Living Light Gewiss Playbus System Vimar Plana Idea Tem Modul Soft Modul Line Master Frames of other vendors most probably suits as well but they were not verified by Smarteh Before installation verify compatibility of non listed frames Module housing has a fin on each side which can be easily removed with knife cutter or pliers This adaptation enables housing to be build in various frame formats with two different depths With regard to frame used you may remove fin for housing to fit in a LONGO programmable controller LP