1. PERONEO Pipetting in the standard mode Tip The standard mode is recommended for rapid series pipetting with aqueous solutions DI SPEN SING FIXED WOL U MN 1000 4 L PROGRAM MODE REVERSE PIPETTE USER SETTING T PIP STD MANUAL PIPETTE 1 4 Press to select the mode PIP 2 A Press downward or upward to select the desired volume When holding down the volume display starts to scroll faster 3 B Press the Option key to select STD 4 Press Start button to trigger all piston movements Blow out is executed automatically when liquid is dispensed A Procedure En ee Kae Se EE eee Upper end position Basic position Ee eee ees all Ji ee End of blow out x Before releasing Start button remove the pipette tip from the solution to prevent any solution from being aspired unintentionally Note There are 6 speeds available for aspirating dispensing The default speed is 3 for all operating modes Basic Operations continued Pipetting with separate blow out BLO Tip BLO is recommended for use with liquids which easily create foam on agitation and or aeration e g Solutions containing protein STANDARD DISPENSING FIXEO YWOLUMHMN RINSE FROGRAM MODE REWERSE PIPETTE USER SETTING MANUAL PIFETTE IP 14 Press to select the mode PIP 2 A Press downward or upward to select the desired volume 8 When holding down the volume display starts to scroll faster 3 D
2. 4 Press Start button to trigger all piston movements Procedure The procedure depends on the Option selected Information on the procedure according to the Option selected is contained in page 3 6 O Beels lnROlersige lele Mutil Pipetting Tip The Mutil pipetting is recommended for sequence series pipetting with aqueous solutions MIUTIL FIFETTING 1 250 pL 2 150 pl 3 221 pl 4 135 pL 5 689 pL HEFT FIFETTING DISPENSING MUTIL DISPENSIM G FIXED WOL KAM DILUT IM amp MULTI ASPIRAT IN ka Gd ka kal kadhar Mutil Dispensing Tip The Mutil Dispensing is recommended for different volume dispensing with aqueous solutions 1 250 pL SPEEL 2 450 pL 2 221 pL 4 198 pL 5 083 pL FIFETTING DISFENSING FIXED WOLU MH DILUT IN amp PR MULTI ASPIRAT ING MUTIL PFIPET TING ladha a ka kal kal kal BAIK Upper end position Basic position End of blow out O Program Operations continue Diluting Tip The Diluting is recommended for dilute more then two solution mixing with aqueous solutions 1 250 pl 2 150 pl 3 227 pL MUTIL PFIPET TING MUTIL DISPENSING FIPETTING DISPENSING FIXED WOLU MN MULTI ASPIR AT IN mn 4 135 pL 5 689 RL 1 El El EJ 5 D Ed T U er end osition EE kalan T PP p Aspirate air Pee eee See Cee eee Cee eee Cee eee eee eee Basic position eee NEEN seer COET e T ee Mutil Aspirating Tip The Mu
3. DIS The aspirated liquid is dispensed in defined partial steps FIFETTING DISPENSING FIXED YOLU RAN PROGRAM MODE USER SETTING Press to select the mode DIS 1 2a Press to select the desired volume per dispensing step B When holding down the volume display starts to scroll faster In the right side max dispensing steps per filling of the pipette tip here 5 steps 1 000uL pipette 3 B If necessary press Option key to decrease the dispensing steps 4 Press Start button to trigger all piston movements Slightly more liquid is aspirated than is necessary for the sum of the dispensing steps Procedure A BC final Upper end position EERE Den LED LAS EE PR ZI SEHR EN ere Total desired volume di Basic position End of blow out Before releasing the Stat button remove the pipette tip from the solution to prevent any solution from being aspirated unintentionally Basic Operations continued Pipetting with a preselected fixed volume FIX Tip FIX is used to rapidly set five frequently used pipetting volumes PIPETTING STANDARD 1000 BLOW RINSE DISPENSING FIED VOL Ubi PROGRAM MODE REVERSE FIFETTE VOLUME SET TING USER SETTING 1 d Press to select the mode FIX 2 Press downward or upward to select the FIX volume g Five FIX volumes are predefined in the pipette 3 Press the Option key until the desired option appears B _ Options STD BLO RIN REV VOLUME SETTING
4. Press the Option key to select BLO 4 Press Start button to trigger all piston movements The residual liquid is dispensed by pressing the Start button separately Procedure Upper end position Basic position End of blow out x Before releasing Start button remove the pipette tip from the solution to prevent any solution from being aspired unintentionally Basic Operations continued Pipetting with separate rinsin RIN Tip RIN can be used for mixing the dispensing volume and the specimen liquid when large volumes are used u PIPETTING Bul STANDARD DISPENSING FIXED WOL U KN 1000 4 L BLOW REVERSE PIFETTE MANUAL PIPETTE PROGRAM MODE USER SETTING F FIF RIN Press to select the mode PIP 2 A Press downward or upward to select the desired volume i When holding down the volume display starts to scroll faster 3 Press the Option key to select RIN 4 Press Start button to trigger all piston movements Rinsing takes place 3 times after liquid has been dispensed and the Start button is released Procedure Upper end position Basic position End of blow out x Before releasing Start button remove the pipette tip from the solution to prevent any solution from being aspired unintentionally Basic Operations continued Reverse Pipettin REV Tip REV is recommended for solutions with a high viscosity Slightly more liquid is aspirated than is necessary f
5. Quick Start Guide Welcome to the Avegene ePipette Use this quide to m Review parts of the pipettor m Install the battery and charging m Operate the pipettor E Care and Support Avegene 20 S200 eP pette sooo RAHE All Avegene ePipette packages contain Pipettor Battery pack Quick start guide and User Manual Performance certification A Pipettor Description Tip ejector Keypad Display AC IN socket Battery pack Start button Finger hook Tip ejector collar 9 B Display and keypad Mode range on Speed Aspirating Dispensing direction DL Piston position Options Volume and units Aliquots Counter Appears during DIS procedure Install the battery and charging e Charge up the battery at least 8 hours before operating the device for the first time Install the battery 1 With the back of the pipettor facing you remove the battery cover fig 2 1 2 Slide the battery into the slot gold colored contact side first fig 2 2 3 Slide and lock the back cover into place fig 2 3 Charge the battery 1 Plug the ePipette charger into a standard AC wall outlet 2 Connect the charger cable to the bottom of the ePipette It takes two hours to fully charge the battery 3 appears for a few seconds when you switch on 4 fmm flashes in the up right corner of the display when the battery is low
6. or the sum of the dispensing steps 5 lll Cu STANDARD DISPENSING FIXED YOLU MN 1000 H L PROGRAM MODE USER SETTING F MANUAL PIPETTE PIF REY 1 Press to select the mode PIP 2 a Press downward or upward to select the desired volume 8 When holding down the volume display starts to scroll faster 3 B Press the Option key to select REV 4 Press Start button to trigger all piston movements Blow out is discarded Procedure Upper end position Total desired volume Basic position End of blow out x Before releasing Start button remove the pipette tip from the solution to prevent any solution from being aspired unintentionally Basic Operations continued Pipetting with the manual option MAN Tip Setting lower speeds is recommended 5 lll Cr 1000 HL PIPETTING DISPENSING FIXED YOLU MH STANDARD BLOW RINSE PROGRAM MODE REVERSE PIPETTE USER SETTING F FIF MAH 14 Press to select the mode PIP 2 Press downward or upward to select the desired volume 3 B Press the Option key to select MAN 4 Press Start button to confirm the selection 5 Press upward to aspirate samples 6 Press downward to dispense samples d 7 Press Start button to leave MAN The MAN option is the equivalent with a mechanical piston stroke pipette Procedure A B Upper end position nfo a Basic position End of blow out Basic Operations continued Dispensing
7. til Aspirating is recommended for aspirate with aqueous solutions until the series complete then discard the full aspirating solution in one step MUTIL FIPET TINS MUTIL DISPENSIN IS DILUT IHG MULTI ASPIRAT ING FIFETTING DISFENSING FIXED WOL KH PROGRAM MODE SER SETTING Upper end position Basic position End of blow out User Settings Operations Calibration Mode Tip The Calibration Mode is recommended for calibration ePipette when maintain or calibration PIPETTING CALIBRATION MODE DISPENSING MASTER RESET FIXED YOLUMM MASTER CLEAR eee MM MODE GREETING 1 Entry the test conditions temperature air TEST CONDITIONS pressure and relative humidity RH 60 BACK A 2 Entry 6 or 10 times the weights of 200 I DD pL ddwater by Excellence microbalances 4 198 56 mg i BACK A 3 Entry 6 or 10 times the weights of 500 u 500 pL ddwater by Excellence microbalances A 4 Entry 6 or 10 times the weights of 1000 I 1000 pL ddwater by Excellence microbalances 4 395 56 mg BACK 5 Calibration Mode will auto calibrate the ePipette CALIBRATTING OK User Settings Operations Master Reset Master Clear Greeting CALIBRATION MODE MASTER RESET MASTER CLEAR GREETING PIPETTING DISPENSING FIXED VOLUMN PROGRAM MODE USER SETTING 1 Master Reset is for reset all setting return to the original setting After please do Calibration mode to calibrate ePipe
8. tte 2 Master Clear is for clear Program Mode setting ePipette calibrate is unnecessary 3 Greeting is for user to into your own slogan to show in the beginning screen ePIPETTE 4000 AVE ENE FITTCON 2005 ePI PETTE 31000 AVE ENE PRS LAB 001 Kezic isleksitleleieig Care and maintenance 1 2 Do not allow any liquid to enter the pipettor Do not clean the display or any labeling using acetone or aggressive solutions Use original spare parts and accessories battery adapter etc Repairs may be carried out by authorized personnel Avegene Support on the web Check http www avegene com literture htm for the latest information and to help you get more for your new product We have the right solutions to meet your needs To learn more about other great features of your pipettor as well as important safety and operating information please review the User Guide or visit www avegene com VEENE Avegene Life Science TEL 886 2 2698 0369 FAX 886 2 2698 0360 Http www avegene com
Download Pdf Manuals
Related Search
Related Contents
ViviCam 2750 - Pdfstream.manualsonline.com Harmar Mobility LiftAL030 User's Manual manuale d`uso / user`s guide Voir le document Igenix IG1707 microwave Music in Paris - Visit Paris Region NOTA - Mondoirrigazione Zanussi ZBS 862 User's Manual Bare & Beautiful - Acheter pas cher avec Le Coin Des Bonnes Affaires Copyright © All rights reserved.