CS-440 User`s Manual

image

Contents

1. GEN A Cell Switch Automation Gone Cellular Model CS 440 Software Programming Guide A product of 8 SCM Technologies P O Box 33157 Cleveland Ohio 44212 www cell switch com CONTENTS Pro 3 Package components ii A A io 3 INTFOduUcCHO Nina dardo 4 o A 4 oo sacasandcend ce Gananeaecesdadoacdneassaacosnecacdaanesecssaaaneeecesdsanenocesaaeneneeeawnens 5 DNOS a 7 Terminal DESCIIPTION ccccseeecccceeeeeeeneeeeecaeeeeeecaeueeeeseeeeessaeeeeeseaaeeeeeeaueeessaaeeeessaeeeesseeeeessaneeesssgeees 8 Configuration guide of CELL SWITCH ooccconnccconccccnnncccnonononanonenanononanrrnnanrrnnannnnnas 9 Sul ACCESS SETUD O O od dado 9 32 Add GO MUNDO error tidad 10 3 9 Basic parameter comida AO 11 3 4 Parameters for alarm ccccecccceceeeeeeeeeeeeeeeeeeeeeeeaeaeeeeeeeaeaeeeeeeeaaaeeeeeeseaeeeeessaaaaeeesessegeeeeseeaas 13 me ARES 0 See ee ee AAA ARA AA 15 AAA 15 3 7 Inputs Qutputs YpPOS oocccccccccccccooonccnnnncnnonnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnrnrrnnnannnnnnininns 17 3 8 Define alarm and recover sms of digital inputs ooonccccccnnnncoccnnnncononcnnnnnannncononnnnonnanennnnnos 19 3 9 Digital INDUC TIMES 19 3 10 Config digital inputs outputs NAME ccccooconnnccnnnnccccnnnonncnnnnnnnnnnnnnnncnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnnns 20 GS POIIN AUC MINY cazerararican scan areeccecaacnenencaapaneeececeaceatnenesaagunne eadsasanece csa aseceicanan uscee
2. Enable temperature sensor alarm Temperature sensor alarm is urgency 4 hours Internal battery ai calas W Enable Temperature Sound alarm w of Save IE Clear Others Reload successfully connected with FC The temperature sensor inside CELL SWITCH can be preset to a high and a low temperature value If the temperature is over the normal range the module will alarm You can send a sms command to CELL SWITCHO to get current temperature value The user can use the Adjust function to calibrate the temperature value 1 TMPAS time timespan of twice alarm TMPAS time is designed to avoid false alarm recovery messages in a short time 2 TMPRS time timespan of resend alarm sms Designed to repeat the alarm status notification to users 0 means disable the repeat notification 3 TMPDLY time time of ensure alarm It is a delay timer to ensure the alarm status O means no counter Page 22 of 27 grammer Software Version 2 54 3 14 Internal battery The internal battery is designed to operate the unit in the event of a power loss When the external power is lost CELL SWITCH will send a Powered by internal battery alarm to the user Basic params Internal Battery Inputs Outputs 3 llata trans ES Time of ensure power alarm sec 1 Sensars al W Enable power lost alarm Imp100_sensor Internal batter of Save Others Reload successfully connected with FPE POWDLY time time of ens
3. 2 54 3 4 Basic Parameters Basic params e S Php er s P ring phone call when alert r 4 o HA 1 e auto answer call of service phonenumbers e auto add basic description with alert sms Basic params print EIU alarm events by com port l delay send sms time when alarm sec jo ar 4 Alarm params holding time after disarm sec o ca when alert sms resend ES times Extend information with report a v Interior temperature Device s memo info ano Inputs Outputs Device Id e Power supply status and ADC params Arm status ane Dari prane Signal of gsm network Alarm digital inputs ADS 1 5ensors of Save Reload successfully connected with FC Others 1 Ring when alert Enabling this option CELL SWITCH will give CS number a phone call then send sms when an event occurs 2 Auto answer call for service phone number Enabling this option CELL SWITCH can auto answer a call for service AMIC and speaker is needed to be connected for the user to communicate to service personnel 3 Auto add basic description with alert sms Enabling this option adds the description such as install position user information that has been defined by user It will be shown in the sms which CELL SWITCH sends to the service phone number 4 Print RTU alarm events by com port Enabling this option data will be sent to the com port in RTU_ O data format 5 Arm delay and disarm del
4. dry contacts and 4 drivable relay outputs User defined text messages are sent to pre configured mobile phone numbers when a pre defined alarm condition happens These pre configured mobile phone numbers can belong to technicians or engineers who are responsible in handling corresponding alarms With the aid of CELL SWITCH the alarm condition brings attention to in charge personnel immediately Also it allows those mobile phone users to trigger any relay output by using a text message The output can be connected with an alarm indication device such as a light or horn The module has a built in microprocessor chip running on a real time operating system It gives immediate response to the status of both the input and output conditions AGSM modem is embedded in the CELL SWITCHO The user has to subscribe to a cellular service that provides a SIM card The CELL SWITCH can then be installed in any location under cellular coverage Optional Centralized Data Monitoring amp Logging Level Control qa E Photo Eye Temp Controller Authorized User s Mobile Device Modei Number CS 884 lt x Cell Switch a Automation Gone Celular Cell Switch CS 884 Features e 4 digital inputs connect dry contact device 4 relay drivable outputs 12V 24V drive electricity lt 0 2A Reliable performance with built in double watchdog Automatic device condition report through text messaging every 24 hour interval User defined alarm con
5. set send a message close instead of system command IOOL1 to close output 1 i Das12 Daramns l JInputs Litput s l Index device command user command in 0 ai WE par EE E wo User defined commands Programe Interlock P User commands Rtu cmd TOOH User end ws x Cancel of Reload successfully connected with FU Page 27 of 27
6. ase use the default parameter Page 11 of 27 1 Alarm for GSM signal low GSM signal normal range is 18 32 CELL SWITCHO will send an alarm sms to the user when the modules GSM signal value is below the value configured 2 Daily report When the daily report function is used CELL SWITCH will send a report sms to all CS numbers at 10 00 AM every morning to report the modules current status 3 Proof Time Proof Time is setting the CELL SWITCH s os operation system with the correct time CELL SWITCH can execute daily reports timed arm or disarm commands or timed output commands Send proof time sms to CS upon power up when CELL SWITCH powers up it will send a sms to CSO requesting proof time CSO can reply with a sms message 999 to the module to complete proof time process Send proof time sms to sp when power up sp number is a service number of GSM operator when CELL SWITCH power up it send a sms to sp and waiting sp reply a sms to complete proof time Attention If the GSM operator has not provide sp number or such services you need not enable this option 4 Device description you can add a description of the module such as installed position or user information the description will be shown in the sms which CELL SWITCH sends 5 Device ID The device ID is an 8 byte ASCII characters which will be shown in the short message received by CS for example 12345678 Page 12 of 27 Software Version
7. ay Define the delay time before sending the sms message This elminates false alarms Defining the time of holding time after disarm arm delay time ensures the fault has been properly reset 6 Extend information with report The module can send a user defined report to CS phones by timer or user s inquiry via sms command This function is designed to let users query the status of the module Page 13 of 27 Extend information with report Interior temperature Device s memo info ano Device Id e Power supply status ani v Arm status ane Signal of zsm network e Alarm digital inputs ADS Daily report configuration a Interior temperature internal temperature sensor the temperature value will show in the daily report b Device Id enabling this option the ID will be shown in the daily report c Arm status enabling this option the arm or disarm status will be shown in the daily report d Signal of gsm network enabling this option the GSM signal value will be shown in the daily report e Device s memo info enabling this option the device description will be shown in the daily report f Power supply status enabling this option the daily report will show power supply status g Alarm digital inputs enabling this option all digital input status on or off will be shown in the daily report From 4401234567 Equipment Id 00000001 Time 9 58 Signal value 27 Power s
8. cacenm caeancaape 21 31205 SAIN ALUMNO BY toldos 21 TO 10 7274 O anata anata sal erat E N suds 22 OTS AILS Ral Temperature GENS O arrossos ansan EOE EEEE 22 Sel MUST MANO ANON Viesi as 23 SO REAME MLCT LOGE cst vars titre E Eaa EE AE ai 24 Pee ARERR 25 AS TINO S ss aa A A 26 Cia CR ca ele lec lag la 21d 0161 PP io A 27 3 20 Define users COMMANdOS occcccccooonncnnnccccccnononnnnnnncnnnononnnnonnnnnnnnonnnnnnnnnnnnnnnnnnnnnnnnnnnnnnrnnnnnannnnennns 27 Page 2 of 27 r Software Version 2 54 Preface Thank you for purchasing our Cell Switch Model CS 440 This manual will describe in detail all of the functions and features of our product This product is designed for use on industrial and commercial applications to stay connected to their processes This product should be used according to this users manual and according to the parameters and technical specifications This product operates on standard cellular networks and is designed to monitor processes In the event outputs are utilized caution must be given to the nature of action that will occur We bear no liability for property loss or bodily injury arising from abnormal or incorrect usage of this product Package Components Number CS440 CS 440 RS232 cable 12V Adaptor GSM antenna CD Page 3 of 27 Il Introduction CELL SWITCH Model CS 440 is designed as a cost effective industrial machine monitoring device The unit monitors or controls up to 4
9. dition normally close or open alarm and recovery SMS message for each alarm point Supporting drive relay output Maximum of 10 mobile phone numbers can be programmable Supporting voice monitoring e Built in temperature sensor and internal battery Page 4 of 27 S 440 Programmer Software Version 2 54 e Configuration can be done via COM port Parameter Relay drive output Digital inputs GSM Engi Watchdog Sls NXP o Industrial MCU Power Battery management ML Audio management DC Input Parameter item DC Power supply Power consumption Frequency range SIM Card Antenna Serial Temperature range Humidity range Output drive voltage Output drive power On state input current Input signal Exterior dimension Weight Reference scope 12 24V DC Standard adapter DC 12V 1 5A 12V input Max 50mA Average 50mA Dual frequency 900 1800 or 900 1800 850 1900 Supporting 3V SIM Card 50 Q SMA Antenna interface RS232 20 70 C Relative humidity 95 Equal to input DC voltage Drive voltage lt 35V drive current 200mA Max 0 33mA Dry contact 95x64x25mm 225 9 Page 5 of 27 amer Software Version 2 54 CELL SWITCHO interface 4 Connector CS 440 Interface LED indicator description Indicator Status Indication description Indicator for power supply the light will be lit when the PWR Red Normally light on ae pened system Is on Module signal indicat
10. e NUNE h Date o hour o min execute HUHE ha Date o hour lo min execute HOHE ka Date o hour o min execute NUKE h Seven timers can be set in a week CELL SWITCH execute a task in each time For example at Monday 10 30 execute send daily report Date Sunday o hour Date o hour min execute HOHE e Date o Four min execute MUNE J min execute HOHE lu o b Date D hour 9 min execute o b b Page 26 of 27 S 440 Programmer Software Version 2 54 3 18 Program Interlock Programable Interlock pr Output ADC params i Index On Event Execute command l Data trans Aajo HL Aali HC i Sensors Aa 2 HC Aaj HC Aal 4 HC _ AalS HC Comm tool Baje HC Event FOWERUF p gt AalT HC j 8 HC uC Action OUTFUTO FULSE Py ogr ame Interlafk Aal 10 HC gt Aaj 11 HC i lAal 12 HC 1 E 13 HC HC User command Aalia E Reload successfully connected with FU Program interlocks are internally configured they are more flexible than realtime interlocks You can set CELL SWITCH to execute many actions automatically according to various types of system events If an event happens CELL SWITCH executes a defined action For example if CELL SWITCH powers up output O will pulse 1 second 3 19 Define users commands Users can define up to six user defined commands instead of system commands For example user
11. er can be modified by sms command or not This CS number can modify other CS numbers by sms command or not Can receive the status sms or not when the module is restarted by sms command Can receive the daily report or not Null Null Can receive the alarm sms or not when internal temperature sensor alarms Can receive the alarm phone call or not when internal temperature sensor alarms Can receive the alarm sms of power failure or not Can receive the alarm phone call of power failure or not Null Null Null Null Null Page 16 of 27 S 440 Programmer Software Version 2 54 Deput _ output ty o Input alarm sms e Input timeouts o Digital inputs rame O Digital output Lame i vs Switching inputs 24 Hours input 0 input 1 input 2 k input 3 Use input 1 as Arm control Sound x lt e x relay driveable outputs output 0 TOC h output 1 1 00 he output 2 TOC na output 3 TOC v C Remember outputs status Other Persist timespan of Siren min TA Save current status Olnput open iinput open Iinput open input open Doutnput off 1outnput off outnput off Soutnput off Reload successfully connected with PC Digital input configuration CELL SWITCHO provides 4 digital inputs Input signals can be configured as two types EDGE_IN edge triggering and LEVEL_ IN state triggering ATTENTION The key defere
12. hone number CS number While CELL SWITCHO is operating in working mode the CS number can be sent via a sms command User has the ability to set 10 CS numbers CSO CS9 While the unit is in set up mode the user can simply select the phone number icon and added the desired phone numbers Pressing the OK button loads the data into the unit 3 ces numbers alerts control phone E 7 A 5 E Y Ma 9 Sal Inputs Outputs Data trans 1 Sensors Others Reload successfully commected with PC Page 10 of 27 Programmer Software Version 2 54 m i o D7 is Err fe 8 cs numbers lalert control phone k Phone mumbers i i Le om Basic params Alarm params mom 3 m A 2 w M Reload successfully connected with PC 3 3 Basic parameter configuration gam band uart bps 9600 uart HOHE e 2 Basic params _ alarm when gsm signal low u he e daily report at 10f3 m send prooftime sms to cs when powerup Alarm params send prooftime sms to sp when powerup Ea e e reply sms for remote successful sms commands oar ae W reply sms for remote incorrect sms commands Pin code 1234 A device id A characters CS s authority country code lli basic descriptions auto add with alert of Save Reload successfully connected with PC Attention for the gsm band uart bps uart pin code country code ple
13. mer per lo seconds exec Hone Timerl per lo seconds exec one Timer per lo seconds exec Hone El Timer3 per lo seconds exec Hone Comm tool System timers Six system timers can be set in a day CELL SWITCH can execute a task in each interval For example at 8 30 execute arm at 17 00 execute disarm System timers minute minute exec minute exec Timers at hour o minute exec Hone minute exec minute exec None we Timerd at CS Timer at D o o eo O Minute timers Four minutes timers execute a task every interval time For example CELL SWITCH executes output 0 will pulse every 30 minutes Minutes Timers per minute exec Pulse DOO na minute exec Spare per o Ee exec Hore a Spans per o AA exec Hone Spanl of Save Reload successfully connected with FE Timers are designed to execute timed tasks Tasks can include arm disarm open close output etc Page 25 of 27 pgrammer Software Version 2 54 Second timers Four second timers execute a task every interval time ATTENTION before using the timers you have to update the modules internal clock The method is described above in the Basic parameter configuration 3 17 Weekly Timers Date o hour lo min execute NOHE Date Sunday e o hour o min execute HOHE e Date o hour lo min execute HONE Date Sunday ka o hour la min execut
14. nce between Level and Edge is Level input has a recovery message and Level inputs can repeat alarm status sms notified by an interval Level input alarm Alarm sms Alarm event Recover sms Repeat alarm sms by interval Recover event Page 17 of 27 Typical edge alarm 24 Hours property l checked the digital input will execute an alarm action send alarm sms interlock etc when it is triggered even when CELL SWITCH is in a disarm status Sound property Means this line alarm event will cause the internal buzzer and an external device if connencted to sound Use digital input 1 as arm control property If this option is enabled when input 1 is opened the module is in the disarm mode and if closed the module is in armed mode A user can connect a button to switch mode from arm to disarm ATTENTION To use digital input 1 as arm control select input 1 as a level type input and delete the alarm recover sms message for input 1 Output types 0 disable 1 relay drivable output 8 relay drivable outputs drive electricity lt 0 2A Output drive relay voltage Equal to input DC voltage Output power Drive voltage lt 35V drive current 200mA 2 This line s actions will synchronize with internal buzzer 3 SNAPSHOOT This line will shortly action when any alarm happens 4 SIREN This line continuous drives for 1 minute by default The interval can be user defined Remember outputs status
15. on recovery The module s outputs default status is open it is possible that during a reset command the output could be closed After restart the outputs will be reset Status is open If this option is checked the output will recover to the status that it was before the restart Page 18 of 27 3 amp CS 440 Programmer Software Version 2 54 El ERA CA Ww Input output type Input 1 activated ae activated al alarm SS activated Input 4 activated Input alarm smf Input 1 untrigger o i a trigger recover St uput J untrigger Input time i Input 1 activated Input 4 untrigzzer Reload successfully connected with FC All of the input line SMS commands can be modified and re defined ATTENTION SMS message can only contain 60 characters 3 9 Digital inputs timeouts Digital inputs params CA wy Input _ output type alarm sms inte alarm sms rese alarm ensure Limespan weg al mm SmS Input Digital inputs alarm sms limit interval min o alarm sms resend interval min o alarm ensure timeout sec E af ox sad successfully connected with PC This page is designed to setup the input timeouts There are 3 intervals related with inputs 1 Alarm sms limit interval is designed to avoid multiple alarm recovery messages in a short time Page 19 of 27 grammer Software Version 2 54 alarm event at here but alarm sms send o ala
16. or will flicker slowly after the NET Green Flicker oe y system Is registered to the GSM network Light will be on when the system receives or sends SRV Yellow Light on during handling short messages and the light will be off when the handling is over The light will flicker periodically when the system is ACT Orange Flicker 9 j y ee under operation and the interval time is 6 sec Page 6 of 27 Cell Switch Model CS 440 Programmer Software Version 2 54 Model Number C5 4 40 PWR K lt EN Cell Switch o ARE Automation Gone Cellular werw cell switth com NET SRY Page 7 of 27 Terminal Description g 1 DC12 24V DC positive terminal of the DC power supply GND Negative terminal of the DC power supply 2 RS232 Connecting computer RS232 to computer 3 4 relay drivable outputs driving relay to close or open Output drive voltage Equal to input DC voltage Positive pole of relay coil connecting DC negative pole of relay coil connecting DO 4 4 Digital inputs Digital input connecting open or close contact Page 8 of 27 ogrammer Software Version 2 54 lll Configuration Guide of the CS 440 Basic Parameters 3 1 To access the setup mode Connect CELL SWITCHO via the RS232 of the computer and open the configuration software configure the software Setup Mode according to the following figure A Note Please choose the
17. rm sms to phones alarm limit interval 2 Alarm sms resend interval is designed for repeated alarm status messages to be sent 0 means this function will be disabled _ resend counter i recover alarmfevent goto alarm i status l l KA resend sms y resend sms Y 3 Alarms ensure timeouts is a timer that must be satisfied before the alarm status is sent O means no counter gt gt State ensure counter alarm event send alarm sms this time 3 10 Config digital inputs outputs name oo basic params Config name of digital inputs Inputs Inputs Outputs a a Index Din name E o Input Input_timeouts Ed 1 Input 1 Ed 2 Input E EI 3 Input 3 2 Digital inputs name Data trans Reload successfully connected with PC Page 20 of 27 40 Programmer Software Version 2 54 lf an input status request is made to the module this type of message will be returned Note the difference between a configured and not configured module from 4401234567 from 2161234567 High voltage normal InputO normal Low voltage alarm Input 1 alarm High water level normal Input 2 normal Low water level normal Input 3 normal Configured input name Not Configured input name 3 11 CS s DIN authority This page configures which CS phones receives digital input alarms O means this CS phone will receive the input sms when alarmed X means it will not be sen
18. serial port No and rate correctly the default communication rate is 9600 default password is 000000 e M RTU 4 digital inputs 4 digital outputs 42 54 Setup mode Reload Restart Load defaults Save Profile Exec Profile Uart COMI Y BPs 3600 Y Parit Y Password ES PA s 8 cs numbers alert control phone Phone numbers Basic params Alarm params Cell Switch CS 440 All sms po e J Please press the OK button then power off then power on the device CS s authority Definition Working mode and setup mode In the setup mode all functions are disabled parameters may only be set CELL SWITCH must be restarted to enter the working mode In the working mode all functions are enabled The module can both alarm and control in this mode A NOTE To access setup mode neither the SIM card or antenna is needed but to access the working mode the SIM card and antenna must be installed Page 9 of 27 grammer Software Version 2 54 A How to determine the current operating mode Method 1 Check the ACT light If the ACT light flickers twice per second this means it is in the setup mode the flicker period of the ACT light can be up to 6 sec under the working mode Method 2 Check the information from the serial port If the character string of dtu returns a message of setup mode it means that CELL SWITCHO is in setup mode 3 2 Add a cell p
19. t Table alarm sms Receiver of digital inputs No lal 1 2 al CS0 E o g CSi y O o 0 Digital inputs coe O Xx O a CSa o O O ki Cod o O O O Cas o O O O e CSE O 0 O 0 e EST O 0 O 0 Digital output cae T 0 T 0 p ceg OD of 0 0 P 3 P A CAs DIN Author This settings means CSO don t receive CS1 don t re linet alarm sms Reload successfully connected with FL Example Ha 0 1 2 3 4 5 E Tad eso Y T T T T T T T This configuration shows CSO will not receive a line O CS1 0 x 0 0 0 0 T 0 o i y gt 5 alarm and CS1 will not receive a line1 alarm sms CS3 T T T X T T T T CS4 0 0 0 0 0 0 0 0 css 0 T 0 0 0 0 T 0 CSE T T T T T T T T CST 0 0 0 0 0 0 0 0 CS8 0 T 0 0 0 0 T 0 csg T T T T T T T T Page 21 of 27 er Software Version 2 54 l Sensors 3 12 Buzzer A buzzer is installed in the CELL SWITCHO The buzzer will be activated when configured it can be stopped by the buzzer reset button on the module or through sending the command with CS number remotely In this page you can enable or disable the buzzer and set interval time of alarm 3 13 Tmp100 sensor Basic params E interior temperature sensor Inputs Outputs r ADC params Data trans Bigh alert 0 centigrade 1 Sensors low alert CO centigrade current EA centigrade burzer Timespan of twice alarm sms min lo k Timespan of resend alarm sms min E h Tmp100 sensor i Time of ensure alarm sec M _
20. upply Normal Computer temperature 30 5 Description Machine Room A1 Floor 4 Building 3 Page 14 of 27 0 Programmer Software Version 2 54 3 5 ALL SMS Se ce Phone numbers activated hapi activated activated Basic params activated untrigger untrigger untrigger untrigger A All sms moo amo ee Ww he 0d M e 0 A CS s authority a pa MN me Qu Alarm Extend DC Power fail Extend DUC Power recover now a 3 0 Reload successfully connected with FU In this page you can see the contents of the sms s that have been defined which include digital inputs alarm recover sms analog input alarm recover sms s etc double click to modify an entry 3 6 CS s authority 2 k i 5 Alarm params Admin modi modi powe dail time a i Se SSS oe eS eS See eS eS S GS ee ate eS te fe SS oes eS es Sa ee es es Co m SSeS SS eS SS eS SS SS Oo 500050050000 0 E E ee amp Reload successfully commected with PC The explanation of the CS s authority O is enable X is disable Page 15 of 27 CS 440 Programmer Software Version 2 54 Authority admin Modify by sms Modify servers Powerup sms Daily report Timer mms Alarm mms l tmp sms l tmp ring Battery fail sms Battery fail ring Signal low alarm Sample sms M2M svr Arm notify PC alarm Explanation Can arm disarm or not This CS numb
21. ure power alarm It is a delay timer to ensure the alarm status O means no counter Battery parameter e Lithium battery e Voltage 3 7V e Capacity 800MAh e Limited voltage for charging 4 2V O Implementation standard GB T 18287 2000 Page 23 of 27 3 15 Realtime Interlocking Timers Weekly timer Comm tool Linkage outputs i 1 l When alert When recover Link with Ho 1 CLOSE HONE Ho 1 CLOSE w HONE v i Ho e dirver pulse interval sec of Dave Reload successfully connected with PC Realtime interlocking is designed to link outputs when an internal action is triggered For example If digital input O is closed output O will close for a pulse of 5 seconds Linkage outputs Output Ho O Ho 1 Ho E Ho 3 dirver pulse interval set then alert 2 CLOSE 1 0 OPEN SE 2 CLOSE PULS a CT OR ARRE of Save rogrammer Software Version 2 54 3 16 Timers System timers TimerO at lo hour lo minute exec Timerl at o hour lo minute exec Timer at o hour o minute exec Timers at o hour lo minute exec Timer4 at o hour o minute exec Timer5 at o hour o minute exec None e Minutes Timers Spani per lo minute exec Hone e Span per lo minute exec Hone ka Spant per o minute exec Hone Spano per lo minute exec Hone second timers Ti