Home
Molift Mover 180 User Manual - Quickie
Contents
1. 14 OTN EEE EEE 14 Periodic inspection Checklist 15 Explanation of symbols This symbol appears in the operator manual alongside any information that applies to safety in the workplace or where there is a risk of person injury Always follow these instructions carefully and exercise extreme caution Q This symbol indicates important and useful information By observing this information the operatpor will be able to work more efficient This information may help simplify routines and explain complicated facts Etac AS molift Etac Supply Gj vik Hadelandsveien 2 2816 Gj vik BM08101 Molift MOVER 180 English Rev B 05 2013 molift About Molift Mover 180 Molift Mover 180 is a mobile passive patient lifter The battery powered lift is made from light materials moves on wheels has electrically adjustable legs and a safe working load of 180 kg The Molift Mover 180 is suitable both in the home care and institutional environment Declaration of conformity The Molift Mover 180 and related accessories described in this operator manual are CE marked in accordance with EU Council Directive 93 42 EEC concerning medical devices class 1 and has been tested and approved by a third party according to standards IEC 60601 1 IEC 60601 1 2 and NS EN ISO 10535 2006 Before using the lift Please refer to page 5 for information about how to assemble the lift You must complete the requisite training before u
2. 2013 Lifting and moving The suspension must always be placed crossways the person who is being lifted Make sure that the sling is fastened securely on all four hooks of the suspension so that the person in the sling does not slip or fall out When moving the patient they must sit low down if possible with their feet placed on the base or so that their centre of gravity is as low as possible This will reduce the risk of instability and or tipping over The lift should also be moved with the legs as wide spread as possible to achieve maximum Stability When moving the patient stand to the side of the person you are lifting Make sure that arms and legs do not obstruct the lift seat bed etc Keep eye contact with the patient to help them feel safe When moving the patient take care to avoid collisions with objects and furniture in the room Avoid thick carpets high door sills uneven surfaces and any other obstacles which may mean the wheels get jammed If the lift is pushed over obstacles it may become unstable and tip over The lift is designed to move patients over short distances only it is not a replacement for wheelchairs or similar BM08101 Molift MOVER 180 English Rev B 05 2013 molift Using the leg adjustment function Use a wide leg setting when necessary e g to get round wheel chairs toilets etc The leg adjustment mechanism has a safety function to prevent the legs from hurting the patien
3. 53 15 inches Dimensions 1250 x 695 x 1270 mm 49 2 x 27 36 x 50 inches LxWxH All dimensions in the illustration are shown in millimetres The lift has a 10 year service life or 30 000 lifts under maximum load SWL if all recommended servicing is carried out BM08101 Molift MOVER 180 English Rev B 05 2013 Labelling The identification label can be found on the col umn Nominal battery Model name voltage O 1 SWL max load MOVER 180 SWL 180 kg bd Refer to Ler tele ag instruction IP24 manual Arme XXXIOOUX Manufactured Ak X3 HAN Article number ANUN and production nar fre Etac AS Etac Supply Gj vi year week Hadelandsyeien 2 N 2816 Gj vik Norway 47 4000 1004 Serial number bar were malift om CO d e e prd C Manufacturer gt FA M Type BF For indoor Use use aste sorting The periodic control label label can be found on the column Inspect the lift us ing the checklist on page 18 12 Month Periodic inspection every 12 months Designated area for date and sig nature for periodic inspection Refer to Instruction manual BM08101 Molift MOVER 180 English Rev B 05 2013 molift Accessories Lifting slings Molift supplies a wide selection of slings and siz es for specific lifting situations The slings are avail able in sizes XXS XXL Disposable slings are also available Molift stretcher The Molift Stretcher is especially designed
4. Page 14 of 16 sure that the checklist is completed and signed each time the lift is inspected Servicing A service light indicates when the lift needs servicing The light illuminates green to indicate that the lift can be used as normal Battery light Service light Electrical emergency lowering function The electronics record the loads lifted and how much the lift has been used After a certain period of operation a signal is given to indicate that service is required The service light has the following signals Service light Status gt Not illuminated Ready for use Yellow Book service lift still functional Red Service required Red sound signal Service urgently re quired Service involves replacing the lift motor and inspection replacement of worn parts This must be carried out by authorised personnel as described in the technical manual instructions Authorised service personnel can use the Molift Service Tool to take readings of the lift s data and to log servicing work The owner of the lift is responsible for logging servicing work and repairs BM08101 Molift MOVER 180 English Rev B 05 2013 molift Periodic inspection Checklist Kolera ol AA OR a ne te de PROG ANA SANTA artes E NeNurltt tin ET NET CN TN ose eases cece Name and certification number OF NSPECTOT sscscccscsessecsctewstissczncosaccstechececcecatavlesusichaceccusstaabeasecdeecseasesteeasentsalsnaaeedesuieiemed Tic
5. a simple touch Art no 1840000 Oo Read the manual that comes with the weight scale prior to use The weight scale has a quick release and other suspension options and can be replaced quickly by following the instructions on page 5 Integrated charger e Art no 1340005 This charger is attached to the lift as a permanent fixture Park the lift and connect to a regular wall socket The battery is charged in the battery holder BM08101 Molift MOVER 180 English Rev B 05 2013 molift Troubleshooting If the lift is not working properly following assembly page 4 and the pre use checklist page 3 the following troubleshooting table may help you to pinpoint the fault Symptom Possible cause solution The lift column is unstable Check the lift column s holder and both allen screws as described in the assembly instructions on page 4 The lift does not roll straight on level Clean the wheels flooring Contact your local service representative The lift only goes up or down the legs Try a different hand control if you have one you may need to replace only go in or out the faulty hand control Dismantle column to check contact point between chassis and column Contact your local service representative The lift runs by itself the leg adjust Clean the hand control contact with spirit to remove any grease ment works by itself Replace the hand control contact your local service representative Contact your loc
6. the chassis out of the cardboard box e Charge the battery N B The battery must not be in the holder on the column during installation e Slide the column into the column holder on the chassis as shown in the pictures below e Lock the lift column in place by fastening the two Allen screws in front and rear of the chassis as shown in the pictures below Screws will ensure that the column cannot be pulled upwards Do not use lifter unless screws are in place e Plug the hand control into the very bottom of the battery holder The hand control has a hook so that it can be hung on the bracket at the top of the column BM08101 Molift MOVER 180 English Rev B 05 2013 e Insert the battery into the holder on the column with the two battery terminals facing downwards Run the empty lift up and down a few times to make sure that it is working proerly The batteries should always be charged prior to use e Install the suspension as shown in pictures below Align supension in fork Insert locking pin Make sure locking pin is properly fastened BM08101 Molift MOVER 180 English Rev B 05 2013 Dismantling e Run the lifting arm into its lowest position e Remove the hand control and battery from the lift to prevent it from falling out in transit e Remove both Allen screws on the front and rear and remove the column Take care to ensure that your feet and arms do not get caught when the column and lifting
7. OPERATOR MANUAL Molitt Mover 180 Etac AS Etac Supply Gjovik Hadelandveien 2 N 2816 Gjovik BM08101 Molift MOVER 180 English Rev B 05 2013 molift by Etac molift Innhold About Molift Mover 180 3 Declaration of conformity 3 Before using the lift 3 Pre use ChecCKIist ccccccccccccscsccccccsesed General safety information 4 TCI TEENE A 4 Safety instructions ses 4 Assembly and dismantling 00 4 ED AGING NE A EE AER 4 AS 4 DIET GE A EEE 5 Storage and transportation 5 How to use the Molift Mover 180 6 Lifting and moving 7 Using the leg adjustment function 7 ES SHINS oo cigars terse EE EE 8 Emergency stop and emergency lowering 8 Batteries and charging system 9 Charging and handling the battery 9 Battery capacity 9 FOCUS sende 9 Technical data 10 EDEN 11 Accessories 00000000000000000000000000000000000000000 1 1 LINO SINGS ee 11 Molift stretcher 11 Page 2 of 16 Optional CQUIPMENL ccccccscccssccescees 12 Alternative suspension with quick release12 Wheel with directional lock 12 Weight SCC sscacarteecavncnstasenevecessnvescteen 12 Integrated charger 12 Troubleshooting ss 13 Maintenance ccccccccccccccscscsccccccccccse 14 CO 14 Monthly inspection
8. The battery charger can be used as a table top unit or can be fixed to the wall The Charger must be placed or installed in a way that makes it easy to disconnect mains cable plug Take care not to damage the cable Charger light iil Se Insert the battery into the charger The light on the charger will come on Battery capacity The LED on the hand control and on the battery holder will illuminate when the battery power falls below a certain level indicating that charging is needed A sound signal will also be heard If the battery goes flat in the middle of a lifting manoeuvre there will always be sufficient power to lower the patient down again BM08101 Molift MOVER 180 English Rev B 05 2013 molift New batteries will not work at full capacity until they have been fully charged and run empty several times O Electronics Battery light Service light Electrical emergency lowering function Emergency stop The lift counts the number of lifting manoeuvres performed This information can be read using the Molift Service Tool which will indicate when the lift needs a service e g a new lift motor Please also refer to the Maintenance chapter The electronics have an energy saving function that shuts the system down after approx ten minutes of inactivity All the lights will go off The electronics will be activated by pressing one of the operating buttons If the lift is in constant use for a l
9. al service representative The lifting arm does not move Make sure that the emergency stop is not activated turn clockwise to reset the emergency stop Conduct an inspection change to a different battery or charge the bat tery The lifts electronics have overheated allow the lift to cool down Make sure that the load weighs no more than 180 kg Make sure that the hand control contact has not come loose Try a different hand control if you have one you may need to replace the faulty hand control Contact your local service representative you may need to use the manual emergency lowering function to lower the patient The battery does not charge There may be a fault with the battery try a different battery or replace the battery There may be a fault with the battery charger try a different charger contact your local service representative k a Noa a If the troubleshooting does not help to resolve your current problem please contact the relevant service personnel your local representative or Etac AS may also be able to refer you to someone to help you with the problem BM08101 Molift MOVER 180 English Rev B 05 2013 Page 13 of 16 molift Maintenance Maintaining the lift involves pre use checklist cleaning inspections and servicing Inspect the lift using the pre use checklist before using the lift to locate any faults or problems You should also carry out routine inspe
10. arm are being lowered Storage and transportation Storage For long time storage it is recommended that the battery is removed and the emergency stop button is activated The lifter can be stored and transported under the following conditions ur e Pressure 70 106 kPa e Humidity 15 93 e Temperature 25 70 C The lifter is designed for use at standard room temperatures 5 to 40 C Following storage or transport at other temperatures leave the lifter in a room with a suitable temperature until it reaches a safe operating temperature Page 5 of 16 molift by Etac How to use the Molift Mover 180 Place the battery in the battery holder The hand control for the Molift Mover 180 has four buttons to move the lift up and down and the legs in and out The hand control has a LED that illuminates when the battery needs charging If the lift does not function when the relevant button is pressed please refer to the trouble shooting guide in the Maintenance section to find out what is causing the problem Battery light Legs in Lifting arm EG me Suspension A Push handle Manual Emergency Hand control dll NE lowering Lift motor 4 F h im Battery holder incl Lift column Yi control electronics and 1 electrical emergency lowering function Legs Emergency stop Battery FORWARDS Chassis BACKWARDS Page 6 of 16 BM08101 Molift MOVER 180 English Rev B 05
11. ctions of the lift namely a month ly inspection and a periodic yearly inspection Cleaning Use pH neutral cleaning agents If disinfection is required use isopropyl alcohol Do not use abrasive or corrosive substances for cleaning e Cleaning shall be done on a regular basis Clean the outside of the lift using a slightly damp cloth and a suitable cleaning agent e Remove any hair and fluff from the wheels and make sure the wheels move freely e You may need to carefully clean the hand control contact and cord with spirit to remove any grease Monthly inspection The lift must be set up for use during the inspection e Inspect the lift using the pre use checklist of things to do before using the lift page 3 e Clean the lift e Make sure that the hand control contacts and charger are securely in place and that the cables on the hand control and charger are intact e Run the lift up and down to make sure that it is working correctly and not making unusual noises e Inthe event of any faults or problems take the lift out of operation mark it with out of order Contact service personnel Periodic inspection Molift recommends a periodic inspection of the lift once a year Current guidelines in this area may need to be taken into consideration This periodic inspection is carried out using the checklist on page 15 The inspection should be conducted by authorised personnel The owner is responsible for making
12. for lat eral transfer of clients wth suspected spinal injuries and fractures It is approved and compatibla with X ray CT scan and MRI scanner It attaches easily to the Molift 4 point suspension Moloft Stretcher Standard excl lifting loops and safety belts Molift Stretcher with MRI compatability excl lofting loops and safety belts Set of lifting loops 4pcs Set of straps with auto strap collectors 4pcs Set of safety belts 3 pcs Item no 2150103 Item no 2150108 Item no 215037 Item no 2150356 Item no 2150355 Page 11 of 16 molift by Etac Optional equipment Alternative suspension with quick release Aluminium suspension e 2 point aluminium large 540 mm Art no 1830001 e 2 point aluminium medium 440 mm Art no 1830002 e 2 point aluminium small 340 mm Art no 1830003 e 4 point aluminium 440 mm Art no 1830011 e 4 point aluminium 540 mm Art no 1830010 Page 12 of 16 Wheel with directional lock Art no 1320140 The wheel must be installed by certified staff who should follow the rear wheel change instructions in the technical manual Wheels with a directional lock have no brakes fitted we therefore recommend changing only one of the rear wheels Push down the red lever to lock the direction To release pull the lever up Weight scale This scale is approved Class Ill The scale can also calculate BMI Body Mass Index with
13. k if OK if any of the items are not OK take the lift out of operation and send it for repair The entire lift has been checked for damage cracks and deformation and is considered to be in good working order The lift has been assembled correctly and no parts are missing The accessories have been checked There is a separate list for slings The battery charger is an ac cessory The emergency stop function and hand control have been checked and are working The lift rolls across the floor preferably checked with a load and its movement is smooth and steady The leg adjustment mechanism has been extended fully and then retracted fully preferably checked with a load its movement is smooth and makes no noise stops in the correct position The lift has been moved to the top and to the bottom preferably checked with a load its move ment is smooth and makes no noise Service is not required if the service light is green and the lift is under 5 years old If the lift needs servicing or repairs it should be taken out of operation The lift passed the safety inspection It has been stamped with the Molift safety inspection mark which is signed and dated Has a completed and signed checklist been forwarded to the client and a copy sent to your Molift representative Notes ITU oer A I EEN A E A E A E BM08101 Molift MOVER 180 English Rev B 05 2013 Page 15 of 16 Find your distributor visit Molift com molift
14. ong period of time there is a risk of the electronics overheating and the lift stopping Allow the lift to cool down sufficiently before using it again Discarded lifters and batteries should be handled as electronic waste and collected seperately according to local laws and regulations Molift Mover 180 should not be run constantly for more than 2 minutes with maximum load and rest for minimum 18 minutes aD Page 9 of 16 molift Empty weight total excl battery and suspension 32 kg 70 5 lbs Chassis 16 kg 35 Ibs Lift column 16 kg 35 Ibs Battery 0 85 kg 1 9lbs Suspension 0 9 kg 2 Ibs Material Aluminium steel and plastic composite Motors Lift motor 12 VDC Leg adjustment motor 12 VDC Battery 14 4 V NiMH 2 2 Ah 20 A fuse ATO Fuse Battery charger Mascot 2215 10 22 cells NiCd NiMH Casing IP24 Number of lifts with fully charged battery 50 75 kg 50 cm 165 Ibs 19 7 inches up down Page 10 of 16 Technical data Safe Working Load SWL 180 kg 400lbs Lifting range 1360 mm 53 5 inches 2 point suspension min max lifting range 370 1730mm 14 5 68 inches 4 point suspension min max lifting range 270 1630mm 10 6 64 2 inches Lifting speed 46 mm sec 1 06 inches sec With 75kg 165 lbs Sound level max A weighted sound power level Ly 49 4 dB Key force Buttons on handset 3 4 N Leg height Max 115 mm 4 52 inches Turning circle 1350 mm
15. ower SWL the lowest SWL will apply The lift may tip over if used incorrectly Make sure you are familiar with the instructions before you attempt to lift anyone A The lift must not be used on sloping floors or ramps Use the push handle when manoeuvring the lift do not pull the patient or the lifting arm Medical electrical equipment requires special precautions regarding electro magnetic compatibility EMC Portable or mobile radio communication equipment may affect the medical electrical equipment and should be kept minimum 25 cm 10 inches from the lifters electronics Safety instructions e The lift has an overload protection function to prevent it from lifting more than 180 kg e The lift is also designed such that it cannot crush patients if it is lowered too far e Pressing the emergency stop button shuts off the power supply straight away and stops the lift e The lift features both an electrical and a manual emergency lowering function e The lift has a light to indicate when it needs service Page 4 of 16 Assembly and dismantling Unpacking e The lift is delivered in a cardboard box Make sure that the packaging is intact upon delivery If it is not intact check the contents of the box if there is evidence of damage inside contact your Molift representative straight away e The box contains a complete Mover lift unit including hand control battery and battery charger Assembly e Roll
16. reset lectrical emergency lowering function mergency Stop Page 8 of 16 Electrical emergency lowering function It is possible to perform an emergency lowering of the lifting arm in case of a general malfunction of the control electronics The button can be found on the battery holder If you need to perform an emergency lowering move the lifter to a suitable location to lower the patient e Press the emergency lowering button on the battery holder the lifting arm will then steadily move downwards The electrical emergency lowering function does not work when the emergency stop is activated e If the lift still does not work replace the battery and test the emergency lowering function again e If it fails to work the patient will need to be lowered manually either using the manual emergency lowering function or by calling for assistance Manual emergency lowering function The lift has a manual emergency lowering function on its motor which can be used when the electrical emergency lowering function is not working Ti Manual emergency lowering function Pull the red handle up slightly Exercise caution as the lift will move more quickly the higher the handle is pulled Releasing the handle too quickly will increase the risk of person injury and damage to the lift BM08101 Molift MOVER 180 English Rev B 05 2013 Batteries and charging system Charging and handling the battery
17. sing the lift on patients When using the lift it is also important to only use accessories and slings that are adjusted to fit e the patient e type of disability e size e weight e type of movement Pre use checklist 1 Check the lift for any visible damage or defects 2 Make sure that the lift s column and suspension are fastened properly and that the lift does not have any loose parts 3 Make sure that the emergency stop switch is not activated and that the lift is working 4 Make sure that the batteries are charged i e the battery indicator on the hand control and battery holder is not illuminated 5 Make sure that the service light is green If it is yellow or red the lift needs service 6 If there are any faults or defects the lift needs to be taken out of operation and marked out of order Contact the service personell or dealer BM08101 Molift MOVER 180 English Rev B 05 2013 Page 3 of 16 molift General safety information General Before the Molift Mover 180 can be started up operator must make sure that the lift is in good working order in terms of both safety and operation The lift must be taken out of operation immediately if faults affecting safety and reliability are identified Molift Mover 180 has an SWL Safe Working A Load of 180 kg This means that it is built and tested to lift patients weighing up to 180 kg When using accessories e g slings and stretchers with a l
18. t when they are being lifted from the floor the motor shuts down in the event of any unusually fast change to the leg setting If this happens press the opposite button to re start the leg adjustment motor Page 7 of 16 molift Using slings Molift Easy sling is an all round sling that fits most users and lifting situations in the home care and institutional environment A variety of slings are available for each specific situation Please consult the operation manual supplied with each sling for more detailed information on how to use and maintain them We recommend using Molift slings with Molift lifts Slings made by other suppliers may vary in their Specifications and centres of gravity and could lead to instability and person injury Molift slings must only be used to lift people NEVER use the slings to transport other objects A Torn cut frayed or broken slings can fail resulting in serious injury to the user Use slings in good condition only Destroy and discard old unusable slings Emergency stop and emergency lowering Contact a service partner if the cause of the shutdown emergency lowering is unknown or if a fault is detected The lift must be taken out of operation and marked with out of order until the issue has been resolved Emergency stop The emergency stop button can be found on the battery holder on the right hand side of the column The emergency stop shuts off the power Turn clockwise to