1. not sealed to prevent condensation from forming If water is relatively clean i e tap water or better and there are only a few drops inside the meter dry it as described below Large amounts of water or corrosive or very dirty solutions will almost certainly damage the meter movement or electronics Such meters should be returned to the Myron L Company for repair To dry your meter 1 Shake excess water out of the inside of the meter 2 Dab the exposed surfaces dry with an absorbent cloth or tissue Avoid pushing any water into the Calibration Control or either of the switches 3 Air dry the meter in a warm area with the bottom cover off Allow several hours for thorough drying If the water entered through a leak in the case or cell or if the instrument shows erratic readings or other unusual behavior return it to the Myron L Company for servicing SERVICE Any service required other than battery replacement cleaning or calibration must be referred to the Myron L Company If you have any questions about this instrument its use or a particular application please contact the Myron L Company STANDARD SOLUTIONS Your DS Meter has been factory calibrated with the appropriate NIST traceable Standard Solution All Myron L conductivity Standard Solution bottle labels show three values ppm 442 ppm sodium chloride and conductivity in micromhos 442 Unless otherwise specified the calibration used for all DS
2. Meters is the 442 standard The 442 Standard Solutions consist of the following salt ratios 40 sodium sulfate 40 sodium bicarbonate and 20 sodium chloride This salt ratio has conductivity characteristics closely matching natural waters and was developed by the Myron L Company over four decades ago Sodium Chloride For every ppm 442 Standard Solution there is a ppm sodium chloride NaCl solution which will have the same conductivity The parts per million of the equivalent NaCl solution is on each Standard Solution label Instruments calibrated to NaCl standards are set using equivalent NaCl values Conductivity All Myron L Company Standard Solutions are traceable to the National Institute of Standards and Technology and are within 1 0 of Potassium Chloride reference solutions The concentrations of the reference solutions are calculated from data in the International Critical Tables Vol 6 ACCESSORIES CONTINUED RECOMMENDED STANDARD SOLUTIONS MODEL RANGE SOLUTION NUMBER 53271 x 10 442 30 x 100 442 300 x 1000 442 3000 with RE 10 442 30 000 532T2 x 10 442 15 x 100 442 150 x 1000 442 1500 with RE 10 442 15 000 532M1 x 10 442 30 x 100 442 300 x 1000 442 3000 with RE 10 442 30 000 RANGE EXTENDER The RE 10 Range Extender is a useful accessory for testing high conductivity opm solutions beyond the normal range of your DS Meter Inserting the RE 10 into a sample filled cell cup increases th
3. Myron L DS Meter Handle your DS Meter and identify these parts to become familiar with it Model 532T1 shown Cell Cup Upper Electrode Meter Zero Adjust Pointer Button Range Switch set on Internal Standard USING YOUR METER 1 Turn the Range Switch to the desired range If you don t know which range to use set it to 1000 2 Rinse the cell cup three times with the sample you want to test For very hot or very cold samples see TEMPERATURE COMPENSATION below NEVER FILL THE CELL BY DIPPING THE METER INTO WATER 3 Fill the cell with another sample to at least 1 4 6mm above the upper electrode 4 Press the black button 5 Read the dial value indicated by the pointer If the pointer is very low on the left or goes off the scale to the right try the next lower or higher range 6 Multiply the dial value by the range setting to determine parts per million ppm Total Dissolved Solids on the 532T models or the conductivity in micromhos umhos on the 532M1 7 Ifthe pointer goes off the scale to the right on the x1000 range try RANGE DOUBLING see inside or an RE 10 Range Extender see ACCESSORIES NOTE When you are finished with the meter RINSE THE CELL CUP with clean water preferably distilled or deionized TEMPERATURE COMPENSATION For very hot or very cold solutions let the three rinse samples each remain in the cell for several seconds Then immediately fill the cell with the sample you wan
4. S Meter still does not indicate the correct value recalibrate it as described below TO RECALIBRATE THE METER 1 Remove the bottom cover using fingernails or a small screwdriver to loosen the front or rear edge Identify the three Calibration Controls see photo below left so you can find them by touch while calibrating 2 Test another sample of the Standard Solution be careful to not to splash solution inside the meter 3 Adjust the Master Calibration Control until the meter indicates the value that is on the Standard Solution label 4 The Master Calibration Control adjusts all ranges For best accuracy in the lower ranges use the recommended Standard Solutions for the x100 and x10 ranges Use the x100 and x10 trimmers to recalibrate those ranges as in steps 2 and 3 above 5 Turn the Range Switch to S and press the button Compare the meter reading to the INTERNAL STANDARD value on the meter s bottom label If they are noticeably different mark the new value in place of the old one NOTE A 532T ppm Meter may be calibrated to read either 442 or NaCl parts per million but not micromhos A 532M1 conductivity Meter may only be set to read micromhos INTERNAL STANDARD An INTERNAL STANDARD value for each meter is on the label on the bottom cover of each meter Use it between normal calibrations as a field check of your meter s accuracy To verify your meter s calibration 1 Turn the Range Switch to S an
5. THREE RANGE DS METERS OPERATING INSTRUCTIONS User s Manual for Models 532T1 D32 le 532M 1 DESCRIPTION This manual describes your Myron L DS Meter tells you how to use it and how to keep it working accurately for many years Your model 532 three range DS Meter is a compact instrument which operates on the principle of electrical conductivity It will quickly determine the conductivity or ppm Total Dissolved Solids of almost any solution Model 532M1 has a dial calibrated in micromhos umhos which is equivalent to the metric microsiemens uS Models 532T1 and 532T2 convert the conductivity directly into parts per million ppm of Total Dissolved Solids All are 3 4 x 4 5 x 4 0 85 x 129 x 126mm and weigh less than one pound 45 kg DS Meters are completely self contained The built in cell is automatically temperature compensated from 50 to 160 F 10 to 71 C They are powered by a 9 volt battery good for at least 2000 tests or one year shelf life MODEL RANGES 53271 0 50 0 500 0 5000 ppm 532T2 0 25 0 250 0 2500 ppm 532M1 0 50 0 500 0 5000 pmho By using an RE 10 Range Extender see ACCESSORIES the maximum range of each meter may be increased ten times MTT LLLA 4777 e amy oss LVED Sor IDS OWN wy oes MYRON L COMPANY Water Quality Instrumentation Accuracy Reliability Simplicity The pictures in this manual show the major operating parts of your
6. Y OU to value shown on label 4 Test sample 5 Double Dial Reading MAINTENANCE BATTERY CHECK al 2 Turn the Range Switch to S and press the button Adjust the Master Calibration Control to maximum If the meter reads less than full scale the battery should be replaced Remove the bottom cover Detach the battery connector Pull on the vinyl strap to remove the battery Replace with a fresh zinc carbon or alkaline 9 volt battery Reinsert the vinyl strap to secure battery ACCESSORIES CELL Self conditioning of the built in electrodes occurs each time the button is pressed with a sample in the cell cup This ensures consistent results each time With some samples a small downward swing of the pointer is a result of this conditioning action This action is powerful and removes normal films of oil and dirt However if very dirty samples particularly scaling types are allowed to dry in the cell cup a film will build up This film reduces accuracy When there are visible films of oil dirt or scale in the cell cup or on the electrode scrub them lightly with a small brush and household cleanser Rinse out the cleanser and the meter is ready for accurate measurements WATER INSIDE THE METER Your Myron L meter is a rugged instrument and will withstand water exposure around its cell meter movement and switches However care should be taken to keep water from leaking in around the bottom cover It is
7. d press the button 2 If the reading matches the INTERNAL STANDARD value on the bottom label your meter is in calibration If not see FIELD CALIBRATION NOTE The feature described above is intended as a quick field calibration check or for using the range doubling technique It is not a replacement for calibration with Standard Solution FIELD CALIBRATION MAINTENANCE 3 Remove the bottom cover using fingernails or a small screwdriver to loosen the front or rear edge Press the button and adjust the Master Calibration Control until the meter reading is the same as the INTERNAL STANDARD value Replace the bottom cover RANGE DOUBLING 1 2 Turn the Range Switch to S Remove the bottom cover While pressing the button adjust the Master Calibration Control until the meter reads one half the INTERNAL STANDARD value shown on the bottom label For example If the INTERNAL STANDARD value is 4 2 adjust the Master Calibration Control until the reading is 2 1 Test your sample take care to keep the inside of the meter dry Multiply by two the reading of the sample tested For example If the meter reading is 3 2 on the x1000 range 3200 the actual value of the sample tested is 6400 3200 x 2 NOTE After completing tests requiring range doubling reset S to its proper value and replace bottom cover EASY STEPS TO DOUBLE RANGE 2 Press Button 3 Adjust Master Calibration Control J
8. ds one half the list price of a new instrument 4 The instrument is over ten years old Because of component changes and improvements such instruments can no longer be repaired NOTE Unrepaired meters are discarded unless you want them returned to you If so there is currently a 35 00 charge per unrepaired instrument to cover diagnosis and handling This warranty is limited to the repair or replacement of the Myron L 53211 53212 532M1 Meters only The Myron L Company assumes no other responsibility or liability 2450 Impala Drive Carlsbad CA 92010 7226 TELEPHONE 1 760 438 2021 FAX 1 760 931 9189 www myronl com Printed in the U S A Specifications subject to change without notice Myron L Company 2008 3ROM WEB 05 08
9. e maximum range ten times Use the Range Extender whenever the reading is off the scale USING THE RE 10 1 Fill the cell cup three times to rinse it but each time insert the Range Extender to rinse it also 2 Fill the cell cup with your sample Push the Range Extender into the cell cup seating the O ring seal 3 Use and read the DS Meter in the normal manner Multiply the reading by 10 4 For best accuracy repeat the complete test with a fresh sample 5 When you re done testing remove the Range Extender Thoroughly rinse the cell cup and Extender with clean water preferably distilled or deionized to eliminate dried salts build up This is extremely important when the instrument will be used to test high purity water RE 10 Range Extender J N CALIBRATING THE RE 10 1 Calibrate x1000 range of meter without RE 10 with Standard Solution 2 Fill cell cup with appropriate high conductivity Standard Solution 442 15 000 or 442 30 000 3 Insert RE 10 and press the button Multiply the reading by 10 and compare it with the value on the Standard Solution label It they are not the same the RE 10 must be recalibrated NOTE DO NOT adjust the Conductivity Calibration Control 4 Adjust the white insert of the Extender as follows If the reading is too high push or tap inward If the reading is too low twist or pull outward with pliers NOTE The Range Extender is factory calibrated to a particular
10. meter It should be recalibrated if it is to be used with another meter PORTA PAK Carrying Case for use with all Myron L DS pDS meters Foam lined and molded of sturdy ABS plastic ORDERING To order accessories contact your nearest stocking distributor or the Myron L Company WARRANTY SERVICE The Myron L 532711 532T2 532M1 Meters have a limited two year warranty If your instrument fails to operate properly check the battery and calibration If it still fails to function properly return it prepaid to the Myron L Company Faulty instruments may be returned to us without prior authorization METERS WITHIN TWO YEAR WARRANTY PERIOD Failures due to materials or workmanship will be repaired or replaced our option without charge if returned freight prepaid If failure is deemed by the factory to have been caused by abuse or tampering the following procedure will apply INSTRUMENTS CONTROLS OUT OF WARRANTY Diagnosis will be made and repairs completed providing the repair charges are 80 00 or less NOTE Actual repair charges may be less than this amount COMPANY Water Quality Instrumentation Accuracy Reliability Simplicity MYRON L We will diagnose but not repair a returned meter and supply an estimate of charges if ANY of the following apply 1 Repair charges will be more than 80 00 2 You specifically request an estimate of required repairs and charges 3 The cost of required repairs excee
11. t to test step 3 above This allows the automatic temperature compensation feature time to work properly CAUTION DO NOT use with samples hotter than 160 F 71 C The readings WILL NOT be accurate DO NOT splash solvents such as lacquer thinner acetone benzene or chlorinated solvents on the plastic case DO NOT fix or modify the meter That will void your warranty See SERVICE for details or consult Myron L Company DO NOT DIP THE INSTRUMENT INTO WATER If water does get inside the instrument see MAINTENANCE for instructions on drying it Lower Electrode inside cell Battery Strap X10 Trimmer X100 Trimmer Master Calibration Control X1000 CALIBRATION STANDARD SOLUTIONS A Standard Solution has a known conductivity and ppm Your meter was calibrated at the factory using NIST traceable Standard Solutions You can keep your meter accurate by using these same Standard Solutions To pick the right Standard Solution for your meter see ACCESSORIES CHECKING CALIBRATION 1 Turn the Range Switch to the x1000 range 2 Test a sample of appropriate Standard Solution CAUTION Throw the Standard Solution away as you use it Don t put the used samples back in the bottle 3 Ifthe DS Meter does not indicate the same value as is on the Standard Solution bottle s label first clean the cell For directions on how to do this see CELL inside Rinse the cell thoroughly and test the Standard Solution again If the D
Download Pdf Manuals
Related Search
Related Contents
Samsung STN-L32D flat panel floorstand Technical Data Fiche technique Model SRV945 Portable Platform Scale Emerson ROSEMOUNT 3000 User's Manual Digitaler Thermostat Digital Thermostat, Thermostat 安全データシート - フォモジャパン SINUS K GUIA PARA A PROGRAMAÇÃO ESMALTE AL AGUA ALTO BRILLO Copyright © All rights reserved.