Home
Main key user manual
Contents
1. will be generated 2 Press the number 7 button 3 Press the Register button 4 Then the auto lock function will be set while a sound Bi is generated for notifying of completion Upon shipment the function is set to default fi gt m A e gt Manual gt When setting the manual lock function 1 Short press the Register button one time a short signal sound Bibi will be generated 2 Press the number 9 button 3 Press the Register button 4 Then the manual lock function will be set while a sound Bi is generated for notifying of completion What is the manual lock function The function will be very useful for offices where people enter and exit frequently In this mode the door will not be locked even when the door is closed While the mode is maintained users can lock the door by pressing the button to lock the door when leaving the office for a business trip or leaving for home and they can enter the office by opening the door by entering the secret codes or using the digital touch keys or smart tags cards when coming back from a business trip or showing up for the day It is also possible to shift to the auto lock mode easily at any time Imaginary code system to prevent exposure secret code Imaginary code function This function will be useful when the user needs to enter the real secret code even when another person is watching nearby This functio
2. Biriri will be generated completing the registration the button to let the deadbolt come out In this state when the user enters the registered new secret code the deadbolt will be retrieved as long as the door lock is in normal condition A When it is needed to check the secret code it is required to keep the door open and press Caution Auto re lock function If the user does not enter the premise within 7 seconds after unlocking the door from the outside by using the secret code or the key or if the user does not go out within 7 seconds after unlocking the door by pushing the door handle down the auto re lock function will be activated causing the door to be automatically locked Security alarm When an incorrect secret code is entered 3 times or more the security alarm function will be activated generating an alarm sound of 80dB or higher for 30 seconds and stopping the system operation for 30 seconds If no secret code is entered within 7 seconds after the Register button is pressed the registration process will be cancelled while an error sound Biriri is generated Upon shipment the secret code 1234567890 is set to default Once the product is A installed the secret code must be replaced with a new one for using the door lock auton Do not let others know the secret code Change it periodically In preparation for an emergency situation in which there is no way to enter the locked prem
3. The brand for a safer life JOYLOCK Since 1970 Main key user manual DOO OOO e JoyLOCK OO OO a JOYLock UNICOR HIGHTECH CO LTD www unicor co kr This manual may change without notice in case of product improvement Product specifications are subject to change without prior notice This manual may not be edited or changed without the manufacturer s prior permission A Caution As this is a keyless digital door lock damage may occur to parts of the dead lock system if it is not used according to the manual Users should be fully aware of the manual and how to operate this product 1 Registering and changing the secret code 1 Press the Register button 2 Enter the new secret code for J o registration 3 20 digits at While the door is opened open the battery cover of the back ass y and press the Register button one time A short starting sound Bibi will be generated Enter the new secret code through the keypad of the front ass y Numerical characters of 3 20 digits except for the and buttons 3 Press the Register button y 3 4 Complete the registration jem Press the Register button after entering the secret code When the secret code is registered normally a melody
4. Then the door will be opened quietly without a melody What is the mute function he mute function is to temporarily control the operating sound to open the door quietly when needed to use the door at an apartment or a common housing by entering he secret code without causing other people to suffer rom the operating sound at night How to use Press the button first and press the button the secret code and the button in order to set the mute unction that will prevent the operating sound from being generated Standard of the product Front ass y 170W X 73H X25D mm Front body Rated voltage DC 6V te Working temperature 20 C Main body 170W X 73H X30D mm to 60 C Sensor working temperature 4pcs 2way touch model Possible to register up to 50pcs High temperature 60 C Digital touch key Smart tag card 2pcs 2way tag model Possible to register up to 50pcs Will run for about 10 months when Battery 1 5V AA LR6 alkaline battery x 4 used 10 times a day 6 8 months in case of card models Non key D NF T NK M Direct current Non fireproof Temperature sensor Non key Main key type Only applicable for JM 630 JM 630C Wye reine D NF T K M Direct current Non fireproof Temperature sensor Key Main key Only applicable for JM 630K The lifetime of the batteries is based on the result of the tests by the company and is not an absolute measurement It will vary depending on the temperature and humi
5. gt Setting A While the door is locked open the battery cover of the back ass y and press the Register button for 3 seconds Then the function will be set while a setting sound Biriri will be generated 1 From the inside Pull the handle down from the inside Then the anti panic function will be activated making it possible for the user to exit by opening the door normally while the forced lock function is automatically disabled Press the Register button for 2 seconds or longer Then the forced lock function can be also disabled 2 From the outside In preparation for a situation in which elderly people or kids set the forced lock function from the inside accidently there is a function available for unsetting the forced lock mode from the outside Press the button Enter the registered secret code gt Press the but ton gt Enter the registered secret code again Press the button Then door will be opened disabling the force lock function Forced lock from the outside What is the forced lock from the outside This function helps enhance the level of security when the user has to leave the premise for a long period of time If someone tries to drill a hole in the entrance door or the fireproof door and insert some instrument inside the premise to move the anti panic handle down or operate the manual knob to enter the premise illegally a powerful warning sound of 80dB o
6. will be generated cancelling the registration AN process When the registration is completed while the door is opened the user must check whether the door lock works normally Caution f an error sound is generated during the registration process for notifying that the time limit is exceeded it is required to start the registration process from the initial stage Deleting the digital touch key and smart tag card This function deletes the registered digital touch keys and smart tags cards for the sake of security Open the battery cover and short press the Register button one time A short signal sound Bibi will be generated Press the number 0 button of the front ass y keypad for 5 seconds Then a sound Biriri will be generated for notifying that the deletion is completed Useless the digital touch key and smart tag card When the digital touch key or smart tag card that the user currently carries is registered again following loss of the previous one the previous one will be deleted while only the currently registered one can be used Prevent micheif and Hacking When an unregistered touch or smart tag card is used 3 times or more the security alarm function will be activated generating an alarm sound of 80dB or higher for 30 seconds and stopping the system operation for 30 seconds The wait time for registering a digital touch key or smart tag key is about 7 seconds When 7 seconds pass
7. Caution in keeping them safe Locking the door from the inside gt When the auto lock function is set After 3 seconds When the door is closed it will be automatically locked within 3 seconds due to the function of the auto lock sensor gt When the manual lock function is set yyanual kno b e e e Open Close Close Open Each time the user turns the manual knob to the left or right direction the door will be opened or closed accordingly i Internal double lock function gt Opening the door by using the handle Pull the handle of the back ass y down slightly Then the anti panic function will be activated disabling the locked state and opening the door e yhanual knob e e e e Open Close Close Open Turn the manual knob to the left or right direction to open the door l Forced lock from the inside What is the forced lock from the inside When all the family members are already in the house this function makes it possible to maximize the level of security by stopping the operation of the front ass y temporarily in order to enhance security When the function is set it will be impossible to open the door from the outside even by using the registered secret code or digital touch key smart tag card In preparation for an emergency situation it is still possible to open the door from the outside by using the emergency key even when the forced lock function is set
8. the registration sound will not be generated requiring the user to go through the registration process again Example When there are 4pcs of keys they need to be registered consecutively f the user lost any one of the digital touch keys or smart tags card s that the user currently carries the user is immediately required to utilize the function of deleting or neutralizing the digital touch key smart tag card to prepare for possible security accidents Caution QO It is possible to register up to 50pcs of digital touch key or 50pcs of smart tag card in the door lock When users want to purchase additional digital touch keys or smart tags cards they can purchase them Attention from the selling shops or the company s customer support center and register them Front ass y Front body x When a specific model is described in _ it means that the currently said information is applicable only for the specific model Touch plate JM 630C JM 630K 3W X In addition to 2pcs of smart tag card that are provided basically 13 56Mhz Keypad ISO 14443A type RF tags NFC cards transportation credit cards can be also registered as smart tags cards eee Operating lamp soylock Emergency key insertion hole JM 630K series Data cable Connect the cable according to the indicated direction for the connec ii tion terminal on the back ass y Emergen
9. because they may leak or explode resulting in Always use new alkaline batteries severe damage Please do not use damaged Do not clean the product with flammable materials batteries such as alcohol benzene or thinners Such materials Do not press using sharp tools or press may damage the surface or cause a fire numeric button excessively Replace the current batteries with new ones within Make sure the door is completely locked when 1 week after the battery replacement notification going out melody sounded off for the first time Product composition Back ass y and front ass y Pads for the back ass y and front ass y Battery 4pcs Assembly bolts Warning sticker Strike Rectangular bar for fixing the handle Support for the rectangular bar a Mortise Product warranty User manual Installation manual f Components of each model Model Door opening type Emergency key JM 630 2way secret code and smart tag card can be used JM 630C 2way secret code and smart tag card can be used JM 630K 2W 2way secret code and key can be used JM 630K 3W 3way secret code smart tag card and key can be used JM 630 JM 630C JM 630K 2W JM 630K 3W It will vary depending on the temperature and humidity of the installed locations as well as depending on the frequency of usage and the quality of batteries Caution The f
10. to be set off Considering this users must check the operating state of the deadbolt of the digital door lock before opening and closing the door Users need to understand how to disable the unauthorized entry and damage alarm gt U t N 1 The alarm will be disabled when going through the authen nset 4 tication process using the registered secret code or digital X touch key smart tag card 2 The alarm will be also disabled when the power is reset Ioer If the door is unstable due to impurities in the door frame the deadbolt may come out while the door is not closed completely causing an unauthorized entry alarm to be set off Considering this users must check the operating state of the deadbolt of the digital door lock before opening and closing the door Users need to understand how to disable the unauthorized entry and damage alarm Caution Battery replacement notification What is the battery replacement notification function When the batteries need to be replaced a melody Open the east east east gate Open the south south south gate will sound off while operating the product The melody lets the user know about the need for replacing batteries If the melody sounds off when operating the system it is required to immediately open the bat tery cover of the back ass y and replace all the batteries 4pcs I with new genuine 1 5V LR6 AA alkaline batteries that can be purchased at nearby stationary st
11. to the KS standards making it possible for people to escape the locked premise by using it simply in an emergency situation like a fire with enhanced safety gt High temperature warning The function will be activated when the temperature sensor which is installed on the back ass y detects heat About 60_ The operating state will vary depending on the environment and state of the installation gt Unsetting the high temperature warning The warning state will be disabled when 3 minutes pass after the alarm sound is generated initially or when the power is reset 60 C 5C is not an absolute measurement for deciding whether the current O temperature is high or low The reference value may vary depending on the mechanical conditions When the high temperature warning system is activated the door will be Information automatically opened even when the forced lock function is set Volume control o E 0 1 2 Mute General High pi sound High pitched Open the battery cover and shift the volume switch to 0 1 or 2 individually for mute general sound or high pitched sound x Upon shipment level 1 for general sound is set to default Mute function Secret code Example of usage When the secret code is 1234 Normal mode Press the button the secret code and the button Then the door will be opened with a melody Mute function Press the button the button the secret code and the button
12. anual knob Locking the door from the outside When the auto lock function is set soylock soyiock After 3 seconds Upon shipment the function is set to default When the door is closed it will be automatically locked within 3 seconds due to the function of the auto lock sensor When the manual lock function is set soyLock Press the button Then the door will be locked Opening the door from the outside Opening the door by using the secret code soyiock Start End Press the button and enter the secret code and press the button Then the door will be opened while a melody sounds off Opening the door by using the digital touch key or smart tag card Bring the registered digital touch key or smart tag card into contact at the touch plate Then the door will be opened while a melody sounds off JoyLock Opening the door by using the emergency key Insert the emergency key into the key hole and lt turn it to open the door alo Xx When a transportation credit card or a NFC card needs to be used it is required to press the button and bring it into contact at the touch plate Users are wholly responsible for all the damage due to exposure or loss of the secret code digital touch key smart tag card or the emergency key Users need to take extra precautions
13. cy power terminal Handle Mortise cable Mortise x Connect the cable according to the indicated Deadbolt direction for the connection terminal on the back ass y Ratchet bolt fixing bolts X They are assembled basically for the right hand mode When the left hand mode is used the user needs to loosen the two fixing bolts and reverse them at 180 degrees and insert them and fasten them again Ratchet bolt Right hand door Opening the door from the outside by pushing or pulling it with the right hand Left hand door Opening the door from the outside by pushing or pulling it with the left hand X Upon shipment the right hand door mode is set to default meaning that there is no need to go through the setting process when installing it for a right hand door If the door is a left hand type it is required to change the direction of the ratchet bolt of the mortise Otherwise the door will not be closed Back ass y Main body Anti panic handle The handle is a one touch type product developed by the company When it is installed successfully the user just needs to swing it down to open the door safely and conveniently when moving from the inside area to the outside area j a S Ss Battery cover Battery insertion area Volume switch Register button M
14. dity of the installed locations as well as depending on the frequency of usage and the quality of batteries The functions design and composition of the product may change without prior notification for the purpose of improving its quality Content of compensation Types of consumer damage Failure occurs within 1 month from date of purchase Product replacement The product 5 P 4 Failure occurs within 1 year from date of purchase Free of charge repair is used in normal Same failure occurs 4 times or more Free of charge repair Paid repair conditions p 7 The repair parts are not available at the main office Product replacement E Oe ores Not the case of failure Paid repair Mistakes and p mishandling Mistakes and mishandling by the user by the user Defective installation and other reasons Xx Details of mistakes and mishandling by the user Not the case of failure When needed to break the product due to the loss of secret code When the door is sagging or installation is defective requiring the product to be reinstalled Request for checking the product for possible problems while there is no specific symptom of a failure Problems in operation occur after the user installs the product directly Other reasons Failure and damage due to natu ral disasters such as fires floods and damage from sea water Penetration by water condensa tion and injection of chemicals requiring the internal circuits to b
15. e replaced and causing failures A visit for repair is needed as there are mistakes and mishan dling by the user such as mistakes in replacing batteries and unskill ful use of the product Defective operation due to poorly inserted batteries and use of defective batteries Failure and breaking due to the use of the product for other purposes Failure and breaking caused by the user on purpose or from an external impact Warranty he warranty period for all of the company s products is 1 year from the date of purchase indicated on the warranty certificate he details of all kinds of services by the company is based on the damage compensation criteria of the consumer protection act by the government Even during the warranty coverage users need to pay the cost for trip technical support and parts for some services if they are in the category of chargeable services he warranty is applicable only in the local area Users must submit the warranty certificate that contains the installation information when needed to request a service the warranty certificate is not available users need to submit a receipt a credit card receipt or a cash receipt instead Except for a simple receipt it is impossible to show the purchase date the warranty period will be applied by taking into consideration the product s manufactured date expiration period 6 months 00 O Unicor Hitech 62 642 3 Gojan don
16. g 72B 4L Namdong Induspark Euncheong ro Namdong gu Incheon Korea Customer Support Center
17. ise due to loss of the secret code it is recommended to carry the additional digital touch key Required to register it which will be provided for each model or the smart tag card Required to register it always or keep it in a safe area in a car Even when a secret code is changed the existing digital touch keys or smart tags cards can be used without going through an additional change process When the batteries are replaced the existing secret code will not be deleted thanks to the function of memory Note g s When a new secret code is registered the previous one will be automatically deleted Safety precautions The precautionary measures are for the safety of the user for the prevention of property damage and for the avoidance of any inconveniences due to an accident These must be read Warning and followed properly Do not disassemble or alter the lock Place the batteries carefully and correctly according Do not install where the distance over to their polarity If the batteries are inserted 5mm between the door and door frame in a wrong way differently from the indicated Please do not expose the secret code and direction or polarity leakage or rupture could occur change the secret code in regularly Pay attention to it Batteries should not be exposed directly to Please do not mix old with new batteries or use heat sources or flames or submerged in water different types
18. n allows the user to enter the imaginary code imaginary numbers together with the real one making it impossible for the person watching nearby to recognize the real one helping prevent the secret code from being exposed How to use the function When the secret code is 1234 The user just needs to enter the real secret code 1234 at the end after random numbers are entered Take note that the first digit of the real secret code cannot be part of the random numbers In this case 1 cannot be part of the random numbers entered prior to the real secret code because 1 is part of the current secret code Example of how to use it correctly 78462 1234 for normal operation R The total number of digits combining the imaginary code and the real secret code should be 3 20 digits If the user presses the first digit of the secret code when pressing the imaginary code the user must enter the remaining part of the real Information Secret code continuously D Notification of the door opened JoyLock J ds While the door is in the auto lock mode if the door is opened this function will notify of the opened state to the user A signal sound Biriri will be generated two times i with an interval of 7 seconds to notify of the opening iG If the door is unstable due to impurities in the door frame the deadbolt may come out while the door is not closed completely causing an unauthorized entry alarm
19. ores or convenience stores Must use general batteries not rechargeable ones e Take precautions in placing the batteries in the compartment in order to prevent leakage or rupture that could occur when they are placed wrongly Must replace the old batteries all with new ones not partially Do not use new ones with discharged ones together e It is designed to operate with the rated voltage 6V If low voltage 4 2 0 3V is detected a melody will sound off e After the replacement if the door lock stops working in a short period of time or the batteries are discharged the batteries could be defective It is required to contact the shop where the user purchased batteries and get new ones as replacement ones rN Caution l Emergency power supply What is the emergency power supply When the batteries of the door lock are completely discharged making it impossible to open the door from the outside by using the secret code digital touch key or the card key this function will help supply the emergency power by using a 9V battery from the outside How to use Purchase a 9V battery in a rectangular shape from nearby stationary stores or convenience stores Bring the battery into contact at the 9V battery input terminal at the bottom of the front ass y and the press the button while maintaining the contact If the power is supplied normally a sound Bibi will be generated and the keypad will be turned on Enter the sec
20. r higher will be generated to prevent the unauthorized entry if it is attempted gt Setting While the door is locked press the button of the front ass y and press the number 0 button for 5 seconds Then the forced lock function will be set while a setting sound Biriri will be Start End generated gt Releasing When the registered secret code is entered or when the registered digital touch key or smart tag card is brought into contact opening the door normally the forced lock function will be automatically disabled Auto setting of the hand type There is no need to go through an additional registration process when installing the product initially or relocating it When the batteries are removed and placed back again the product will recognize the hand type automatically making it easy to set the function completely i Trespass Breakage alarm What is the forced lock from the inside While the door is closed if someone tries to break in or enter illegally by opening up a gap in the door causing the deadbolt to be removed forcibly from the auto locking sensor this function will generate a very powerful alarm sound of 80dB or higher for 3 minutes to notify of the dangerous situation Setting the auto manual lock function gt When setting the auto lock function fa dd lt Auto 1 Short press the Register button one time a short signal sound Bibi
21. ret code and then press the button or bring the registered digital touch key or smart tag card into contact Then the door will be opened It is OK to bring a 9V battery as an emergency power into contact regardless of the and polarities e When it comes to a key type model it is possible to enter by using an emergency key even in this sain That is why it is recommended to carry the emergency key usually or keep it in a safe place in a car The emergency power can be supplied when keeping the 9V battery into contact at the input terminal Information not rechargeable e Replace all the discharged batteries right after supplying the emergency power Warning the jam of the deadbolt J D In a situation where the door cannot be locked normally even when it is closed because of the jam of the deadbolt and while coming out due to abnormal installation and irregularities with the door this function will notify of the problem to the user If the user keeps failing to lock the door 3 times a melody Biriri Biriri Biriri will sound off Joyiock l High temperature warning system in preparation for fires What is the high temperature warning system system When the product detects temperature of 60 52 due to a fire inside the locked premise a warning sound of 80dB or higher will be generated and the door will be automatically opened within 5 seconds In addition the manual knob is mounted according
22. unctions design and composition of the product may change without prior notification for the purpose of improving its quality i The lifetime of the batteries is based on the result of the tests by the company and is not an absolute measurement Registering again the digital touch key smart tag card 1 Press the Register D 2 Register new digital touch keys or button Jep smart tags cards u A a 5 o f Joyiock m i While the door is opened open the battery cover Bring the digital touch keys or smart tags cards into of the back ass y and press the Register button contact at the touch plate of the front ass y in order one time A short starting sound Bibi will be When each key is registered normally a short signal sound generated Bibi will be generated 3 Press the Register 4 Complete the registration button When the registration is completed normally a melody Press the Register button after registering all the Biriri will be generated completing the registration digital touch keys and smart tags cards 5 Check the registration While the door is opened the user must check whether the registered digital touch keys or smart tags cards are working well before closing the door Once the Register button is pressed if neither the digital touch key nor the smart tag card is brought into contact within 7 seconds an error sound Biriri
Download Pdf Manuals
Related Search
Related Contents
mm ambiante 700 fireplace NOE top - NOE-Schaltechnik Ikon LED User Manual Melissa 631-047 User's Manual 2. Búsqueda de Facturas/Pólizas/Constancias 選択的試料導入装置 MODEL SS-1010E 取扱説明書 User`s Manual Copyright © All rights reserved.
Failed to retrieve file