Home

Technical_Manual_Click_And

image

Contents

1. e Secure the Click amp Go with 4 bolts to the frame Pay attention The maximum width between the mounting plate and the guiding frame is 3 mm see figure 8 The space between the Click amp Go and the floor must be around 1 5 until 2 cm Figure 8 ti anid Place the push handle extensions see chapter 3 Mounting push handle extensions EX x lt lt EL E 2009 VAN OS MEDICAL UK LTD Tel 44 0 1757 701177 Fax 44 0 1757 706011 E mail i VANOS Technical user manual 3 Mounting of the push handles extensions There is a possibility that the push handles of the wheelchair on which you want to place the Click amp Go are too short to use in combination with the Click amp Go system When your attendant is pushing you he will hit the Click amp Go with his feet This can be very annoying To prevent this you use the supplied push handle extensions The push handle extensions makes sure your attendant can push you with the Click amp Go system without any problems Pay attention When you want a Click amp Go with your Excel G4 wheelchair you need to drill out the push handle with a bore of 18 mm until a depth of 48 mm 3 1 Mounting the push handles extensions Remove the rubber from the push handles of your wheelchair figure 9 Most push handles have on the inside a anti slip layer therefore you need to cut the rubber loose to remove them Take the supplied plastic plug It with fit in the push h
2. Smart mobility solutions Technical Manual Excel Click amp Go Compact Read instructions before use Technical user manual Contents 5 IE POCUECUCION seien E ETE E E E EEE E S 2 LLP Se O E EE ice acts E E E E E E E E E ON EEA 2 2 Mounting the Click amp GO esssesssesosescoessoeesosesoeeseesceeeoeeeseseceeeceseceesceeeoe 2 2 1 Mounting of the Click amp GO cece cece nce e eiee eraa ai 2 3 Mounting of the push handles extensions ccceeceeccecceeceeceeceeceeccecceeceeees 5 3 1 Mounting the push handles extensions c cee cee cececceccecceeceeceeececceeceeceeees 5 4 Mounting universal MOUNTINGSEL cece ec ee cece cece ce ee eee eeeceeceeceeeeeeceeceecees 6 4 2 Adjusting fixation plates wscucessccscctetcesdssnesseeseunwentnas sede eckedsentotsenscecevsisacen 6 Dy Fautt codes Click GO COMDACL sssrrcceerrntidcrntt rintre inis TENE CENEO TEEI NEER 8 6 Tuning the hand controller sssessssssssscssscesseessceesceesoeesoeesoeesoeesoeesoeesoees 9 2009 VAN OS MEDICAL UK LTD Tel 44 0 1757 701177 Fax 44 0 1757 706011 E mail sales vanosmedical com www vanosmedi m Technical user manual 1 Introduction You have just purchased a Van Os Medical UK Ltd powerpack and we want to thank you for the confidence in our EXCEL products In this technical manual we would like to guide you step by step guide in assembling the Click amp Go system on a Excel wheel
3. ends on all the strips This is important for the rest of the mounting procedure Figure 18 On the heart line of the strips are 4 holes 2 holes for the smaller clamp blocks 2 holes for the bigger clamp blocks Place the contra nuts on the tap ends and tighten them down Make sure the tap ends is equal with the back of the mounting strip figure 19 Place one side the clamp blocks over the tap ends figure 20 and repeat this for the second strip Figure 19 Figure 20 Hold the mounting strips including the clamp block against the side frame of the wheelchair figure 21 Place the second side of the clamp block over the tap ends figure 22 and place the cover plates against the backside of the second side of the clamp block figure 23 L 22 L Figure 23 Figure 21 ISHS S EXCEL 2009 VAN OS MEDICAL UK LTD Tel 44 0 1757 701177 Fax 44 0 1757 706011 E mail sales vanosmedical com www vanosmedical com VAN OS ee Technical user manual Tighten the nuts with your hands on the tap ends figure 24 Hold the mounting model including the fixation plate against the mounting strips figure 25 Make sure that the holes of the mounting strips and the fixation plate are above each other figure 25 oa oa P Figure 24 a Pal Mark these holes and tighten the fixation plate with a M6 x 8 mm bolt to the mounting strips Figure 25 Securely tighten all bolts and nuts when you are sure the fixation plate is in p
4. S E L O EXCEL VAN OS For international customers VAN OS MEDICAL B V Koperslagerij 9 4651 SK Steenbergen The Netherlands Tel 31 0 167 573020 Fax 31 0 167 573381 E mail sales vanosmedical nl For UK and Ireland VAN OS MEDICAL UK LTD 42 44 OuseGate YO8 4NH Selby United Kingdom Tel 44 0 1757 701177 Fax 44 0 1757 706011 E mail sales vanosmedical com www vanosmedical com
5. andle tube exactly figure 10 Figure 9 e Figure 10 Place the plug against the push handle extension on the side with the smallest hole side that is weld see figure 11 Place the supplied bolt in the push handle extension and tighten the plastic plug with your hands against the end of the push handle extension figure 12 Place the plastic plug in the push handle tube and turn the bolt firmly down figure 13 SO SO Figure 12 A Figure 11 Figure 13 Check if the extension is securely tightened by making lateral movements with it After this you need to assembly the hand controller in the right and the easiest way for your attendant Please pay attention to the push handle extension when you are placing the hand controller figure 14 Use one of the supplied fillings for the hand controller Place the supplied extended push handle rubbers over the push handle extensions figure 15 The best way to do this is to rub the inside of the rubbers with benzine the rubbers will glide gently over the tubes As soon as the benzine in the rubbers is dried up the rubbers are securely tightened Figure 14 Figure 15 E x lt C i E i 2009 VAN OS MEDICAL UK LTD Tel 44 0 1757 701177 Fax 44 0 1757 706011 E mail sales vanosmedical com www vanosmedical com VAN OS Technical user manual 4 Mounting universal mountingset Content 4x 16 holes plate for mounting of the mounting plates 8x tube clamp tube diamet
6. chair We have tried to make this technical manual as simple and user friendly as possible However if there is anything unclear please contact our technical department 1 1 Preparation To assemble the Click amp Go you need the following Parts and tools Parts delivered with the Click amp Go Figured e Control lever Figure 1 e Fixation plates Figure 2 e Push handle extensions Figure 3 Tools e Allen wrench 4 y e Allen wrench 5 v e Wrench 10 t V e Phillips Screwdriver Figure 2 Figure 3 2 Mounting the Click amp Go Before you start with mounting of the Click amp Go on the wheelchair you need to check the following first When you have a wheelchair without anti tip wheels we suggest you to order and mount these first Our order number is 92000012 When you have a wheelchair with seat width 50 cm or more you need to use an adaptation set 50 55 cm in stead of the original guiding frame Our order number is 08100330 When you have a wheelchair with a seat height different than 50 cm you need to use the universal mounting set our order number 08100302 When you order the universal mounting set you need to mention the diameter of the tube of the wheelchair Excel wheelchair 25 mm DN A Mounting of the Click amp Go First remove the crutch holder Remove the bolt and the nut of the Anti Tipper Check that the drilled holes in the fixation plate match the holes in the Excel whee
7. er that is mention by you 4x cover plate 8x tap ends M6 8x nut M6 8x self locking bolt M6 Our ordernumber Tube diameter 19 mm 93810922 Tube diameter 22 mm 93810923 Tube diameter 25 mm 93810924 4 2 Adjusting fixation plates When you have a wheelchair with a different seat height or from a different brand is it possible that the holes in the fixation plates don t match the frame holes When the holes in the fixation plates don t match the frame holes you have to follow the following procedure to install the fixation plates Take the supplied mounting strips from the universal mounting system figure 16 The mounting strips makes it possible to mount the Click amp Go under wheelchairs outside of the Excel range Ear E x lt C i E 2009 VAN OS MEDICAL UK LTD Tel 44 0 1757 701177 Fax 44 0 1757 706011 E mail sales vanosmedical com www vanosmedical com VAN OS Technical user manual Assemble on both sides of the side frame of the wheelchair two mounting strips figure 17 The two mounting strips are meant to be universal adaptation plates to make sure the fixation plates of the Click amp Go can be adjust to the right height and distance Figure 16 LE Figure 17 Turn the supplied tap ends in the holes that are point out until the back side of the tap ends are equal with the back site of the mounting strips figure 18 Repeat this for the other strips Make sure you use the same holes for the tap
8. lchair frame If so mount the mounting plate with the bolts on the side frame of the wheelchair as shown in Figure 4 If not go first to Chapter 4 E x lt C i E i 2009 VAN OS MEDICAL UK LTD Tel 44 0 1757 701177 Fax 44 0 1757 706011 E mail sales vanosmedical com www vanosmedical com VAN OS Technical user manual Pay attention Make sure the right plate is at the right side Keep in mind the long and short pin Make sure the long pin is at the backside at the bottom of the plate a 5 ex Figure 4 e At the front side of the mounting plate you need to place rubber rings of circa 4 mm This makes sure the mounting plate will be paranc to the mame tube see figure 5 2 i Figure 5 VAIE ii yh j Make sure you use bolts with a sunk or flat head You do not want the bolts to point out Front side M6x40 Back side M6x50 Repeat this procedure on the other side Place the crutch holder back on the wheelchair in the way it is shown in figure 6 EXCEL VAN OS 2009 VAN OS MEDICAL UK LTD Figu re 6 el 44 0 1757 701177 Fax 44 0 1757 706011 E mail sales vanosmedical com www vanosmedical com Technical user manual e Place the Click amp Go between the mounting plates Slide out the guiding frame of the Click amp Go until they touch the mounting plate Make sure the Click amp Go is in the middle so the guiding frame must be equal at both sides see figure 7 Figure
9. osition Repeat this procedure for the other side of the wheelchair 5 Fault codes Click amp Go Compact With S Drive controller All lights are blinking Check potentiometer stand 0 and wiring Check the connector of the motor and the motor brushes When the red light blinks Flash code Slowly Batteries needs to be charged Every 5 seconds Sleep mode switch the Click amp Go on again Fast Check wiring or program the Click amp Go again PAY ATTENTION When the Click amp Go does not function at all Check the battery connection the automatic fuse and the glass fuse E x lt C i E i 2009 VAN OS MEDICAL UK LTD Tel 44 0 1757 701177 Fax 44 0 1757 706011 E mail sales vanosmedical com www vanosmedical com VAN OS ee Technical user manual 6 Tuning the hand controller Loosen the hex screw on the back of the throttle You can reach the hex screw through a hole on the back side of the hand controller see figure 26 Figure 26 Tighten the set screw of the gas potentiometer as far back as possible against the clock You can reach the set screw trough the hole on the right side see figure 27 Serial number DBDoOOoOo 138 1 Figure 27 Securely tighten the hex screw and check the working of the Click amp Go 9 EXCEL 2009 VAN OS MEDICAL UK LTD Tel 44 0 1757 701177 Fax 44 0 1757 706011 E mail sales vanosmedical com www vanosmedical com VAN OS SS SS S