Home

AT-IMC1000T/SFP User Manual

image

Contents

1. The power outlet should be located near the unit and be easily accessible Caution The AT IMC1000T SFP Industrial Media Converter must be powered only by a UL Listed power supply marked either LPS or Class 2 rated 56Vac 1A Caution The AT IMC1000T SFP Industrial Media Converter must NOT be operated from Centralized DC battery The site should provide easy access to the ports on the front of the chassis so that you can easily connect and disconnect the network cables as well as view the unit s LEDs e Air flow around the unit and through the side and rear vents should be unrestricted Do not place objects on top of the chassis Do not expose the device to moisture or water Make sure that the site is in a dust free environment Use dedicated power circuits or power conditioners to supply reliable electrical power to the network devices e f you are installing the chassis on a table be sure the table is level and secure Keep the media converter chassis and the twisted pair cable away from sources of electrical noise such as radios electric motors transmitters broadband amplifiers power lines and fluorescent fixtures 5 2 Installation Steps 1 Unpack the unit packing 2 Check the DIN rail clip is screwed on the unit If the DIN rail clip is not screwed on the unit please refer to the DIN Rail Mounting section for DIN rail installation If you want to wall mount the unit then please refer to the Wall Mou
2. MV Allied Ielesis AT IMC1000T SFP Industrial Gigabit Media Converter User Manual 613 001978 Rev A Copyright 2001 2014 Allied Telesis Holdings K K all rights reserved Copyright 2001 2011 Broadcom Corporation No part of this publication may be reproduced without prior written permission from Allied Telesis Inc Allied Telesis and the Allied Telesis logo are trademarks of Allied Telesis Incorporated All other product names company names logos or other designations mentioned herein are trademarks or registered trademarks of their respective owners Allied Telesis Inc reserves the right to make changes in specifications and other information contained in this document without prior written notice The information provided herein is subject to change without notice In no event shall Allied Telesis Inc be liable for any incidental special indirect or consequential damages whatsoever including but not limited to lost profits arising out of or related to this manual or the information contained herein even if Allied Telesis Inc has been advised of known or should have known the possibility of such damages AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual Preface I FCC Warning This Equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against ha
3. Figure 3 2 ee FIGURE 3 3 Push the chassis down AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 14 Mounting Installation Wall Mount Plate Fixing 5 Release the downward pressure on the chassis and allow the bottom slot of the chassis DIN Rail clip to tightly fix itself to the DIN Rail 6 To remove the AT IMC1000T SFP Industrial Media Converter lightly press down on the chassis and pull the bottom of the chassis away from the bottom DIN Rail track Then lift the chassis up off the upper DIN Rail track 3 2 Wall Mount Plate Fixing Follow the steps below to mount the AT IMC1000T SFP Industrial Media Converter with the wall mount plates included Note It isn t necessary to remove the DIN Rail clip with the wall mount brackets installed 90 degrees from what is shown Place the wall mount plates on the rear panel of the media converter See Figure 3 4 Use the screws to secure the wall mount plates on the media converter Use the hook holes at the corners of the wall mount plates to hang the industrial switch on the wall To remove the wall mount plates reverse the steps above ANH GREEN CONNECTOR SHOULD BE FACING UP POINTING THE CEILING FIGURE 3 4 Wall Mount Plate Fixing AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 15 Cabling Installation Installing Copper Ethernet Cable 4 Cabling Installation This section describes the cable installation for the
4. List e 1x AT IMC1000T SFP Industrial Gigabit Media Converter e 1 set of Wall Mount kit 2 brackets and 4 screws e 1xATI Product Insert and China RoHS HS TS Substances Concentration Chart 1 4 Supported SFP For a list of supported transceivers refer to the AT IMC1000TP SFP Data Sheet which can be found on the AT IMC1000T SFP 2 Port Gigabit Ethernet Industrial Media Converter product page at alliedtelesis com 1 5 Safety Precaution Warning Please use a protection devices on the inputs of the power supplies that supply DC voltage to the AT IMC1000T SFP Gigabit Ethernet Industrial Media Converter AT IMC1000T SFP Gigabit Ethernet Industrial Media Converter 7 Hardware Description Front Panel 2 Hardware Description In this paragraph we will introduce the Industrial Media Converter s hardware spec port cabling information and wiring installation 2 1 Front Panel The Front Panel of the AT IMC1000T SFP Industrial Media Converter is shown as below 10004 O100 10m OD UNK ACT eo oen FIGURE 2 1 Front Panel of the Industrial Media Converter 2 2 Top View The top panel of the Industrial Media Converter is equipped one terminal block connector of two DC power inputs Warning Please connect Ground Wire to Ground Screw located near to the power socket AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 8 Hardware Description Wiring the Power Inputs DC Source 2
5. a safety hazard by leaving exposed wire on the terminal block after installation E10 Check to see if there are any exposed copper strands coming from the installed wire When this installation is done correctly there should be no exposed copper wire strands extending from the terminal block Any exposed wiring can conduct harmful levels of electricity to persons touching the wires E12 Only trained and qualified personnel are allowed to install or to replace this equipment E14 Do not install in direct sunlight or a damp or dusty place E16 Circuit Overloading Consideration should be given to the connection of the equipment to the supply AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 22 Reviewing the Safety Guidelines circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern a E21 Caution The unit does not contain serviceable components Please return damaged units for servicing E42 Caution During normal operations the SFP module may have a case temperature that exceeds 70 C 158 F If you remove the module exercise caution when handling with unprotected hands E43 AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 23
6. port is transmitting or receiving data It may cause some data error Note Besides if you change the DIP switch setting please power off the converter and power on again to make the setting effective 2 7 Ports RJ 45 ports Auto MDI MDIX The RJ 45 ports are auto sensing for 10Base T 100Base TX or 1000Base T devices connections Auto MDI MDIX means that you can connect to another switch or workstation without chang ing straight through or crossover cabling See figures as below for straight through and crossover cable schematic AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 11 Hardware Description Ports 2 7 1 RJ 45 Pin Assignments Pin Number Assignment 1 TX 2 Tx 3 Rx 6 Rx Note and signs represent the polarity of the wires that make up each wire pair All ports on this Industrial Media Converter support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other switches or hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable The table below shows the 10BASE T 100BASE TX 1000Base T MDI and MDI X port pin outs Pin MDI X Signal Name MDI Signal Name 1 Receive Data plus Transmit Data plus RD TD 2 Receive Data minus Tr
7. AT IMC1000T SFP 4 1 Installing Copper Ethernet Cable Insert a Category 5e cable into copper RJ 45 port P1 and the other end of the cable into the network link part ner s copper RJ 45 port ex switch PC or Server The cable between the link partner switch hub workstation etc and the converter must be less than 100 meters 328 ft long and comply with the IEEE 802 3ab 1000Base T standard for Category 5e or above When the AT IMC1000T SFP is powered on and the link partner network device is active the copper RJ 45 port P1 LED will light up indicating a link or link activity Please refer to the LED Indicators section for LED light meaning 4 2 Installing SFP Module and Fiber Cable Insert the proper SFP module and connect fiber cabling as explained in steps 7 and 8 of paragraph 5 2 The SFP port P2 LED on the unit will light up when the AT IMC1000T SFP is powered on and the link partner net work device is active Please refer to the LED Indicators section for LED light meaning AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 16 Hardware Installation Selecting a Location 5 Hardware Installation 5 1 Selecting a Location Here are the guidelines for choosing a location for the media converter e The AT IMC1000T SFP Industrial Media Converter may be installed on a desktop on a wall or on DINRAIL Note The DINRAIL bracket must be ordered separately from the AT PC2002 POE media converter
8. Active Green 1000M Amber Connector Fiber 1 G Duplex LC SFP bay slot x 1 RJ 45 10 100 1000Mbps Socket x 1 Fiber Parameters Fiber parameters and distances will depend upon the used SFP module Please refer to SFP module documentation Link Lose Forward TX gt SFP If TX port link down the media converter will force SFP port to link down SFP gt TX If SFP port link down the media converter will force TX port to link down Switch Architecture Store and Forward Power Input 12 48VDC redundant power with polarity reverse protect func tion and removable terminal block Power Consumption 5 28 Watts max Operating Tempera ture Wide Operating Temperature 40 C to 75 C Operating Humidity 5 to 95 Storage Environment 40 C to 85 C Dimensions Metal case IP 30 30mm W x 140mm H x 95mm D Installation DIN Rail and Wall mount design AT IMC1000T SFP Gigabit Ethernet Industrial Media Converter Overview Packing List EMC e FCC Class A e CE EN61000 4 2 ESD e CE EN61000 4 3 RS e CE EN 61000 4 4 EFT e CE EN61000 4 5 Surge e CE EN61000 4 6 CS CE EN61000 4 8 e CE EN61000 4 11 e CE EN61000 4 12 CE EN61000 6 2 e CE EN61000 6 4 Safety e UL cUL CE EN60950 1 Class 1 Division 2 Stability Testing IEC60068 2 32 Free fall IEC60068 2 27 Shock IEC60068 2 6 Vibration 1 3 Packing
9. DC Source 1 FIGURE 2 2 Top Panel of the Industrial Media Converter 2 3 Wiring the Power Inputs Please follow the steps to connect the power wires V V V V FIGURE 2 3 V and V Contacts 1 Insert the positive and negative wires into the V and V contacts on the terminal block connector FIGURE 2 4 Wire clamp Screws 2 Tighten the wire clamp screws to prevent the wires from loosing AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 9 Hardware Description Wiring the Fault Alarm Contact 2 4 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires it will detect the fault status which the power is failure or port link failure for managed model and form an open circuit FIGURE 2 5 Fault Alarm Contacts 1 Insert the wires into the fault alarm contacts N 3 and 4 Note The wire gauge for the terminal block should be in the range between 12 24 AWG 2 5 LED Indicators The LEDs located on the front panel display the power status and network status of the Industrial Media Converter Each of them has its own specific meaning as defined in Table 2 1 Table 2 1 Industrial Media Converter LED Definition LED Color Description PWR1 Green On Power input 1 is active Off Power input 1 is inactive PWR2 Green On Power input 2 is active Off Power input 2 is
10. Peel 7 Hardware Description usine eei ne trier cose iru se resa en tr a re er id iS 8 lgeoiduurjbe e a desounaanaads 8 jo mur pep 8 Waring the Power puts siet tre nat nan ns 9 Wiring the Fault Alarm Contact 2 ce ede uode ta eeepc de ee 10 LED Indicators VALE 10 IBI cid 11 0 KAE E rc HER OR 11 Mounting Installation 45 osa n I Entum dr aio RR SEaPO PM siepe eb sm eS RE OO c Gael 13 DINE aL MORBUS cec esee Sepe hie REDI ee Ea ea itp Uu endte 13 Wall Mount Plate Fine iiie irent inining i 15 Cabling Installation sie svecess scescsgeasasceoesseeecevesdosseueoseteesesnssesguns teseosadacacaeasetevvesseectecssdeceveens 16 Installing Copper Ethernet Cable aeri podre oti debates oxides cio descendens ees 16 Installing SFP Module and Fiber Cable 2 ie hat Gade oed isque 16 Hardware Installation iic in etie ipt cat ciecs ccas Creo e riaa inge Gehe REM eS Dep dedo 17 Selecting bivio 17 SEMEN ESI TR RD p 17 Troubleshooting cerit ee eosa a ctio ee tace pe tub cca ama uec ee eaae dM esr cd SCR a Rari Feu e c eeu aged eon 21 Reviewing the Safety Guidelines 4 eee e eee eee eee eee eee ee ee ette setate sette setae seta ae 22 AT IMCIOOOT SFP Industrial Gigabit PoE Media Converter User Manual Introduction l 1 Overview 1 1 Introduction The AT IMC1000T SFP Gigabit Ethernet Industrial Media Converter is designed to convert Gig
11. abit copper Ethernet networks to Gigabit fiber networks by transparently converting Ethernet signals to optic signals The advantages of fiber optics are wide bandwidth EMI immunity and long distance transmission capability The AT IMC1000T SFP is an ideal solution for fiber to building applications at central offices or local sites On the copper port it supports MDI MDIX auto detection so you don t need to use crossover wires Furthermore the AT IMC1000T SFP can work normally in an extended temperature range from 40 C to 75 C and accepts a wide voltage range from 12 48 VDC It also provides 3 000 VDC surge EFT protection against over voltage so it is suitable for harsh operating environments 1 1 1 Gigabit Fiber Converter This switch converter has one SFP slot which provides the flexibility when planning and implementing a network The slot can accept most 1000M SFP type fiber modules that are designed for transmitting over many Kilometers This means you can easily change the transmission mode and distance of the switch by simply pulling out the SFP module and plugging in a different module The SFP module is hot swappable and plug and play 1 1 2 Dual Power Input To reduce the risk of power failure the Industrial Media Converter provides 12 48 VDC dual power inputs If there is power failure the unit will switch automatically to the secondary power input 1 1 3 Flexible Mounting The Industrial Media Converter is compact
12. and can be mounted on a DIN Rail or a wall so it is suitable for any space constrained environment 1 1 4 Advanced Protection The power line of the switch converter supports up to 3 000 VDC EFT protection which secure equipment against unregulated voltage and makes the unit safer and more reliable Meanwhile 6 000 VDC ESD protections for Ether net ports make the Industrial Media Converter more suitable for harsh environments 1 1 5 Wide Operating Temperature The operating temperature of the the switch converter is between 40 C to 75 C With such a wide range you can use the Industrial Media Converter in some of the harshest industrial environments that exist 1 1 6 Environments This equipment is for use in pollution degree 2 environments AT IMC1000T SFP Gigabit Ethernet Industrial Media Converter 5 Overview Features 1 1 7 Easy Troubleshooting LED indicators make troubleshooting quick and easy The 10 100 1000 Base TX port P1 has 2 LEDs that display the link status network activity and the port speed Also the three power indicators P1 P2 and Fault can help you diagnose power issues immediately 1 2 Features Table 1 1 Unit Features Standard IEEE 802 3 10BASE T IEEE 802 3u 100BASE TX IEEE 802 3ab 1000Base T IEEE 802 3x Flow Control and Back pressure IEEE 802 3z 1000BaseSX LX standards LED Indicators Per unit Power1 Green Power2 Green Fault Red Fiber Link Active Green TX Link
13. ansmit Data minus RD TD 3 Transmit Data plus Receive Data plus TD RD 6 Transmit Data minus Receive Data minus TD RD Media Converter Router or PC 3 TD gt 3 TD 6 TD lt 6 TD 1 RD lt 1 RD 2 RD lt gt 2RD Media Converter Router or PC 3 TD 3 TD 6 TD 6 TD 1 RD 1 RD 2 RD 2 RD AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual Mounting Installation DIN Rail Mounting 3 Mounting Installation 3 1 DIN Rail Mounting The DIN Rail clip is screwed on the AT IMC1000T SFP Industrial Media Converter when out of factory If the DIN Rail clip is not installed on the back of the media converter please see the following figure to screw the DIN Rail on the switch Follow the below steps to hang the industrial switch 1 Use the screws to screw on the DIN rail clip on the industrial switch 2 To remove the DIN rail clip reverse step 3 1 1 Rear Side DIN Rail FIGURE 3 1 DIN Rail Mounting 3 Align the top of the chassis DIN Rail clip on the rear of the chassis with the top track of the DIN Rail See Figure 3 1 AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 13 Mounting Installation DIN Rail Mounting FIGURE 3 2 Push the chassis down onto the upper DIN Rail track 4 Lightly push the chassis down onto the upper DIN Rail track until the bottom of the chassis can swing back toward the wall and under the bottom DIN Rail track See
14. inactive Fault Red On Power input 1 or 2 has failed Off Power input 1 or 2 are both functional or no power inputs L A Green On Fiber connected to network Blink Networking is active Off Fiber not connected to network SPD Amber On Link to 1000 Mbps network Off Not connected to network or not working at speed of 1000M AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 10 Hardware Description DIP Switch Table 2 1 Industrial Media Converter LED Definition LED Color Description L A Green On RJ 45 connected to network Blink Networking is active Off RJ 45 not connected to network 2 6 DIP Switch Table 2 2 Industrial Media Converter DIP Switch Status Definition S W No Status Description 1 On Enables Port Power Alarm Off Disables Port Power Alarm 2 On Enables LLF Off Disables LLF Link Loss Forwarding DIP Switch 2 When LLF enabled it allows UTP link failures to be reported to the fiber side and also allows Fiber link failures to be reported to the UTP side Therefore a link fault pass through feature is provided in both UTP and Fiber side Note When SW 2 is on once the fiber or UTP STP cable is disconnected the LNK ACT LED off When the cable is reconnected the LNK ACT LED blinks for 2 6 seconds which means the connection is recovering from failure Note Please don t change the DIP switch setting when UTP or fiber
15. ing Only an authorized Allied Telesis service technician should make repairs to this device The TX and RX multiplexing ports contain embedded Class 3B lasers operating in Class 1 compliance Do not make any modifications to the unit that would override the safeguards that maintain the Class 1 compliance The laser light used by the multiplexing ports and SFP modules is invisible Standard safety precautions e g avoid looking directly into a fiber optic port should always be observed when installing or maintaining this product L5 Do not look directly at the fiber optic cable ends or inspect the cable ends with an optical lens L6 To prevent electric shock do not remove the cover No user serviceable parts inside This unit contains hazardous voltages and should only be opened by a trained and qualified technician To avoid the possibility of electric shock disconnect electric power to the product before connecting or disconnecting the LAN cables E1 Do not work on equipment or cables during periods of lightning activity E2 Air vents must not be blocked and must have free access to the room ambient air for cooling E6 Operating Temperature This product is designed for a maximum ambient temperature of 40 degrees C e E7 All Countries Install product in accordance with local and National Electrical Codes E8 Do not strip more than the recommended amount of wire Stripping more than the recommended amount can create
16. l Gigabit PoE Media Converter User Manual 19 Hardware Installation Installation Steps FIGURE 5 5 Pull out the SFP module AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 20 Troubleshooting 6 Troubleshooting e Verify that you are using the right power cord adapter DC 12 48V please don t use the power adapter with DC output higher than 48V or it will burn this converter down e Select the proper UTP STP cable to construct your network Please check that you are using the right cable Use unshielded twisted pair UTP or shield twisted pair STP cable for RJ 45 connections 100Mbps Category 3 4 or 5 cables for 10Mbps connections or 100Mbps Category 5 cable for 100Mbps connections Also be sure that the length of any twisted pair connection does not exceed 100 meters 328 feet e Diagnosing LED Indicators the unit can be easily monitored through panel indicators to assist in identifying problems which describes common problems you may encounter and where you can find possible solutions e If the power indicator does not light up when the power cord is plugged in you may have a problem with power cord Then check for loose power connections power losses or surges at power outlet IF you still cannot resolve the problem contact your local dealer for assistance e Ifthe LED indicators are normal and the connected cables are correct and the packets still cannot transmit Please check your system
17. nt Plate Fixing section 3 To hang the unit on the DIN rail track or wall please refer to the Mounting Installation section 4 Connect Ground Wire to the Ground screw located near the Power Socket 5 Power on the Unit and the power LED indicator on the unit will light up Please refer to the Wiring the Power Inputs section on how to wire the power Please refer to the LED Indicators section for meaning of LED lights 6 Prepare the twisted pair straight through Category 5 cable for Ethernet connection AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 17 Hardware Installation Installation Steps 7 Insert the transceiver into the SFP module Notice that the triangle mark is the bottom of the module Triangle Mark FIGURE 5 1 SFP module to bay FIGURE 5 2 SFP module inserted into its bay AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 18 Hardware Installation Installation Steps 8 Insert the fiber cable LC connector into SFP module as shown in Figure 5 3 FIGURE 5 3 LC connector to SFP module 5 2 1 Removing the LC connector from the transceiver 1 Press the release tabs on the upper side of the LC connector and pull the fiber cable out of the SFP module See Figure 2 6 for the location of the fiber cable release tabs FIGURE 5 4 Remove LC connector 2 Second push down the metal loop and pull the SFP module out by the plastic part AT IMC1000T SFP Industria
18. rmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy It may cause harmful interference to radio communications if the equipment is not installed and used in accordance with the instructions However there is no guarantee that interference will not occur in a particular installation If this equip ment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following mea sures e Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver e Connect the equipment into an outlet on a circuit different from that to which the receiver is connected e Consult the dealer or an experienced radio TV technician for help II CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 3 Table of Contents 5 Mo deylo at EC RRS 5 Introd cti on e T 3 I EE P 6 Ig xupAbI P RS 7 Supponmeu SEP eeraa A e EN ANE A A a A 7 Ssatety
19. s Ethernet devices configuration or status AT IMC1000T SFP Industrial Gigabit PoE Media Converter User Manual 21 Reviewing the Safety Guidelines 7 Reviewing the Safety Guidelines Please review the following Safety Guidelines before you begin to install the AT IMC1000T SFP Industrial Media Converter Note Note Warning Warning Warning Warning Caution Warning Warning Warning Caution Warning Warning Warning Warning Caution The amp indicates that a translation of the safety statement is available in a PDF document titled Translated Safety Statements posted on the Allied Telesis website at www alliedtelesis com Refer to the documentation that comes with the SFP module to determine whether the module is a Class 1 LED product or a Class 1 Laser product Class 1 Laser product L1 Do not stare into the laser beam L2 Class 1 LED product a L3 The fiber optic ports contain a Class 1 laser device When the ports are disconnected always cover them with the provided plug Exposed ports may cause skin or eye damage L4 Using controls making adjustments to performance or performing procedures other than those specified herein may result in hazardous radiation exposure The protection provided by the equipment may be impaired if the equipment is used in a manner not specified by Allied Telesis Inc Do not remove the cover from the unit or change any of the internal cables or wir

Download Pdf Manuals

image

Related Search

Related Contents

fichier 1 - CRDP de Montpellier  User's Manual - TQ  Sony CMT-LX40I User's Manual  User manual / Manuel d'utilisation / 用户手册  Grundig 50 VLE 9230 BL 55" Full HD Smart TV Wi-Fi Black  Sharp LC-19D1E CRT Television User Manual  PYLE Audio PADH1549 User's Manual  Cryogenic Freezer - User Manual [DE]    Manual Avalon TREINOS  