1. 624 0001 Scandinavia 358 10 421 4141 E mail contact parcelcube com Skype parcelcube Technical support 24 7 support parcelcube com www parcelcube com www parcelcube de
2. and have the calibration weight 20kilos Copyright Manual calibration without calibration object and weight Make sure you followed the steps outlined on pages 3 4 Chose Edit Admin login to enable configuration password is dimwei Chose Edit Configuration to open up the configuration window Select High res ensuring that Smoothing Imperial and NTEP OIML are NOT selected Click Save and OK Position the main window and configuration windows so that you can see both Calibrate dimensions Place an object of known size for example 20 x 20 x 20 cm and preferably made of wood or metal on the Parcelcube Observe the dimensions in the main window If a dimension such as width is listed as too small such as 19 5 in the configuration window manually change the width under Table Dimensions in cm to current value 20 19 5 So if the current value was 63 5 you would change it to 64 If for example the length shows as 20 5 you would then decrease the current length value according to current value 20 5 20 Thus if the current value was 64 5 you would then change it to 64 Calibrate weight To set the TARE zero weight of the Parcelcube Make sure the Parcelcube is totally empty In the Parcelcube main window locate the status bar at the bottom and find the value to the RIGHT of the value with a red background In this example the value is 8905 192 168 1237 20280 COM TARE MME 3905 Enter this va
3. I Bind to IP address 1927 168 1 112 EWE wiht Bind to Fort 3080 Remote Webservice un Clear this to disabled Display port COM3 Copyright Gripner Production AB Table dimension in cm calibration values for dimensioning High res Dimensions measured with 1 decimal Weight with 3 decimal Smoothing Stabilize the measurements Imperial Use imperial units instead of metric NTEP OIML Used if you have a Parcelcube NTEP OIML approved indicator User defined values Nicknames for the 7 fields of additional data you can save can be configured to clear or not clear after each Registering of data scale calibration calibration values for scale not used if you have NTEP OIML Dim kg m3 Dim weight COM Port Comport the Parcelcube is connected to CSV directory Location where the CSV file will be saved Webserver API IP address and port Parcelcube software will bind to Remote webservice url See Remote Webservice uri page 12 F9 configuration See F9 configuration page 8 Display port Only used with special Parcelcube Display must NOT enable if you do not have the extra display You have to click Save to apply any changes you do in the configuration All settings uses comma not period Copyright Item stacking If you wish to measure many small objects smaller then minimum allowed size you can use item stacking Say for example you have 200 business card Stack them along the height put in 200 in the Height pcs field
4. PAHRCELCUE Designed and produced in Scandinavia ParcelCube 900 R2 INDEX Assembly I Bas Installation and initial start up Main screen Configuration screen Measure oversized objects Item stacking Item counting Measuring oversized objects F9 configuration Auto calibration dimension and weight Manual calibration without calibration object and weight CSV Web service O ECF Ea DI ME KKI Q lt re Remote Webservice URI Copyright Assembly Requires Philips screwdriver Assemble the back piece Aluminum part with Parcelcube logo with the main piece as shown in picture Be sure to mount the back piece at a right angle Loosen the screws from the main section according to picture Hang the back piece on the 2 screws and tighten in order 1 2 3 Copyright Installation and initial start up Make sure to carefully follow the installation instructions below Connect the AC DC adapter to the AC power outlet Do NOT connect the USB cable amp Download the following file and unzip to c root directory of the C drive https dl dropboxusercontent com u 3950023 parcelcube Parcelcube 20 R2 20installation 20files zip y Run serial_installer exe located under c Parcelcube R2 publish as administrator y Insert the USB cable from the Parcelcube into your computer The found new hardware wizard should appear and install the USB serial port driver Run setup e
5. The field Height will show total height and the field Height under item stacking will show the size of each business card Measuring oversized objects If you have an object too big to fit on the Parcelcube you can still use the Parcelcube to reg ister the data Under File menu chose Pause Serial now you can manually enter the dimen sions and weight Register the data and again under File menu chose Start Serial F9 configuration This option allows you to configure the Parcelcube software to emulate a keyboard typing in the volume and weight data to any application Say you want to save the measurements to an Excel file with the column layed out as Length Width Height Weight You configure the F9 as t w t h t W If The excel file will be filled in when you press the F9 key fictional volume and weight data Length Width Height Weight 23 41 12 0 77 43 23 12 1 33 Auto calibrating dimension To do an auto calibration you need to be logged in as admin in the software Edit gt Admin login password dimwei Once logged in you have access to Edit gt Auto calibrate dimen sions You need to follow the on screen instruction and have the calibration object L20 W20 H30cm Auto calibrating weight To do an auto calibration you need to be logged in as admin in the software Edit gt Admin login password dimwei Once logged in you have access to Edit gt Auto calibrate weight You need to follow the on screen instruction
6. ated from dimensions and dim weight 11 Green if Weight gt Volume weight Red if Volume weight gt Weight 12 7 User definable fields First field will always have focus at program startup and after Registering data 14 Number of items stacked along the length 15 Length per item 16 Number of items stacked along the width 17 Width per item 18 Number of items stacked along the height 19 Height per item 20 Weight per item 21 Number of pcs 1 Fast TARE not saved just used until restart or next time TARE is pressed Save all measurement data and additional information as User defined fields If you have configured Remote webservice URI a call will also be made with all the data 1 2 Set the weight for 10pcs see Item counting on page 8 Copyright Configuration screen Table dimensions in cm User defined values Scale calibration Length user valuel Barcode Clear Tare S000 6 Width p Multiple 75 user value Customer Clear m 96 2 user value3 user value3 Cen Highres Smoothing user value4 user value4 Clear Volume Weight L_ Imperial user valued user_value5 Clear Dimkg m3 250 user value6 user value6 Clear COM Port NTEP OIML user value user value Clear COMS F9 configuration JPARCELCUBE aoran a e ee ee ee Ee ee ee Width lower case w Height lower case H COV direct Weight capital WW ae TAB lower case t c parcelcube R2 es Carige retum lower case cr Line feed lower case Y WebServer AP
7. e Field 4 Height variable size Field 5 Volume variable size Field 6 Weight variable size Field 7 Volume Weight variable size Field 8 User Value 1 variable size Field 9 User Value 2 variable size Field 10 User Value 3 variable size Field 11 User Value 4 variable size Field 12 User Value 5 variable size Field 13 User Value 6 variable size Field 14 User Value 7 variable size Field 15 Item stacking length variable size Field 16 ltem stacking width variable size Field 17 Item stacking height variable size Field 18 ltem stacking weight variable size Field 19 Item counting of pcs Each field ends with a semicolon except the last field which ends with CRLF Copyright Web service The Parcelcube software has a built in webserver offering a simple web service The webserver is based around a client issuing a http GET and the Parcelcube webservice replying with a standard HTTP 200 and text plain header followed by a single line of ascii en coded data For example Format is same as in CSV file Field 1 Field 2 Field 19 lt CRLF gt Each field is terminated with a semicolon except the last field which is terminated with CRLF HttphebRequest IP and port should be the one in the parcelcube config Dim response As HttphebResponse CType request GetResponse HttphebResponse Get the stream associated with the response Dim receivestream As Stream response GetRespons
8. eStreamt Pipes the stream to a higher level stream reader with the required encoding format Dim readStream As New StreamReader receivesStream Encoding UTFS MseBox readStream ReadToEnd Dim parcelcube_string As String Try parcelcube_string readStream ReadTo md Split Catch End Try item_lenght_txtbox Text parcelcube_string item_width_txtbox Text parcelcube_string 1 item_height_txtbox Text parcelcube_string 2 item_weight_txtbox Text parcelcube_string 4 response Close readStream Close parcelcube_string has all the data even though this example only uses 4 values If you want the calculated volume parcelcube_string 3 will hold it CRLF Copyright Remote webservice URI This is used to send data to other systems via an http get Configure the Webservice uri with the correct uri Parcelcube software will add an equal character and an uri encoded data string to the uri For example if your webserver running the webservice have ip address 192 168 20 1 and use port 8900 Your webservice is called pcdata and expect an http get variable named data the uri would look like this http 192 168 20 1 8900 pcdata data The Parcelcube software will add and equal character and the same string as in CSV http 192 168 20 1 8900 pcdata data Field 1 Field 2 Field 19 lt CRLF gt Copyright Call us International 24 7 44 2088 175 264 USA amp America 1 240
9. h swercsse WebServer API Bind to IP address LW Elt w tht Bind to Fort Remote Webservice un Clear this to disabled Display port Copyright Gripner Production AB Chose the COM port in the drop down box named COM Port that corresponds with the Parcelcube serial port Set the Bind to IP address to the computer s IP address Using your calibration protocol delivered with the Parcelcube populate the Table dimensions and Scale Calibration fields Press Save and OK in the popup window and close the configuration windows Press Run in the main window The system is now up and running Copyright Main screen File Edit Running Metric Lengt Width 137 Register Enter Height Volume User defined values 42 Barcode Customer user_value3 uservalue4 user_value5 j_ ltem stacking Length 1 14 pcs Size per item Width l 16 pes size peritem 13 17 Height 1 18 pes Size peritem 45 5 19 Weight per item 40 105 2 tem Counting Setweight of 10pcs of pcs 21 user value user_value 192 168 1112 8080 COM5 TARE 1 File menu 2 Edit menu 3 Start the Parcelcube software communication with the hardware and webservice 4 Toggle Metric or Imperial units Units used iand shown are in Metric 5 Measured objects Length L 6 Measured objects Width W T Measured objects Height H 8 Volume in m3 or ft3 LxWxH 9 Weight 10 Volume weight calcul
10. lue 8905 under Scale Calibration TARE in the configuration Click Save and OK Now the weight in the main window should be hovering around 0 To calibrate the weight Place a known weight on the Parcelcube around 20 kilos Observe the weight in the main window If it displays as less than 20 kilos increase the multiple under Scale Calibration in the configuration window Make sure to click Save and OK to see changes Once you are satisfied with the result you can use Imperial and or smoothing as you see fit You should also remove high res if using non Imperial measurements For a full explanation of all fields in the main window and configuration please see our online video Copyright File View CSV i ji E Wea fe The a P aa a a a a baa e ieith 2245 2013 oa 05 2 au a PriF a DUNHA 22 4045 bi ded AHE 2S 225 POS 39 65 40 a5 SOUS 25 5500 22 225 AU RS 2155 Pa a4 fH 29 S542 id Pra aT SS SOT OS 7 55 be SOT SNS 29 55 85 AUJURA S58 DUHH 22 360 ua 25 on Doi E AHAT EAM TIAIA 20S ST Pr Pr 54 irr a ere rt a EAN ees SOTO 7 Sh ri ajer nE Er rat FAM TIAI AOH 29 56 74 aF 25 4 ni ZAIT EAN T IZEI This option will bring up a view of the current CSV data The CSV file is located in the path defined in the configuration form The Parcelcube CSV file format is as follows Field 1 Date and time in computer s current format variable size Field 2 Length variable size Field 3 Width variable siz
11. xe located under c Parcelcube R2 publish Once the Parcelcube installation is finished you will be presented with the below window Parcelcube R2 File Edit Run ltem stacking Length Length 1 pes Width Register Size per item Enter p Height Width 1 pes Volume m3 Size per item Weight z Vol Weight J L vot weig Height E pos User defined values Size per item Barcode Customer Weri per em user_value3 ltem Counting user_value4 Set weight of 10pcs user_value5 of pcs user_value6 user_value PARCELCUE IP Address Port Com Port TARE Boo 000 The Parcelcube 900 software is preconfigured although there are some minor settings that need to be adjusted Chose Edit Admin login to enable configuration password is dimwei Chose Edit Configuration to open the configuration window Copyright Installation and initial start up Step one is to determine which serial port Parcelcube was assigned Device manager Ports COM and LPT Look for Teensy USB Serial COMx Configuration O os Table dimensions in cm User defined values Scale calibration Length aa Oer Te Width Multi 75 user_value3 Clear Highres C Smoothing user_value4 Clear Volume Weight F9 configuration Width lower case w Height lower case H Weight capital WW CSV director weg p i Y TAB lower case Y Carige retum lower case cr Line feed lower case Y Q PARCELCUBE p
Download Pdf Manuals
Related Search
Related Contents
repeatedly to select - CNET Content Solutions Mode d`emploi LEDI ® ORIGINAL MMBertucci et D.Delas Français des Banlieues, Français Populaire 圧力センサ/圧力センサコントローラ Samsung WEP 410 Bluetooth Headset User Manual TL-MR3040_V1_QIG_7106503965_ES - TP-Link Starlight 650TVL Bullet Camera Sony XR-6600RDS User's Manual Copyright © All rights reserved.