1. 2 filters are needed 7 1 Fan specifications Type K3G190 RC05 03 Motor 36055 Nominal voltage VAC Nominal voltage range VAC Frequency Hz Type of data definition Speed min 1 Power input W Current draw A Min ambient temperature C Max ambient temperature 1 230 200 240 90 60 ml 3200 83 OD 25 60 ml max load me max efficiency fa running at free air cs customer specs cu customer unit Subject to alterations City M Manual Ver 001 September 2014 www camfil com camitil TECHNICAL MANUAL City M 7 2 Air flow 0 m h to 430 m h in 6 different speed settings With Gigalam NXPP H13 Camfil CityM with K3G190RC0503 sucking side Free air Opa Level Airflow Speed Input power Sound pressure level qV m h u min Pe W sucking side LpAss dBA 1 37 520 4 lt 15 0 16 0 2 67 728 5 515 0 16 0 3 94 907 6 515 0 16 0 4 127 1072 7 5 251 1772 19 as 6 433 2733 55 52 6 8 Use The air purifier is used to clean indoor air by mechanically filtering through highly efficient filters Development of the system is primary for expert users and installation companies for offices hospitals and schools 9 Safety instructions Read the technical manual and follow the instructions The machine s power supply has to be disconnected during installation servicing maintenance and filter replacement CAUTION Pull out the electrical connector
2. or use the safety switch when working on the product The machine is not to be regarded as de energised until 5 minutes after disconnection from the power supply Rotating parts do not stop immediately once power has been cut or the machine has been switched off Allow 5 minutes to elapse before handling the cabinet City M Manual Ver 001 September 2014 www canrfil com camitil TECHNICAL MANUAL City M 1 In its standard version this product must only be used for handling dry non explosive materials If the air purifier is used for purposes other than those set out in the technical Manual or is handled otherwise than set out therein Camfil AB can accept no liability whatsoever for the consequences of said use handling 2 NOTE Fixed installation may only be carried out by a professional with the appropriate qualifications who takes responsibility for the installation 3 The machine must not be used in ATEX classified areas or where explosive gases may be present at any time 4 Electrical connection may only be carried out by an appropriately qualified electrician 5 All accessories filters spare parts etc used must be approved by Camfil Guarantee undertakings cease to apply if the foregoing is not respected Please contact Camfil for the correct accessories 6 Do not cover inlets or outlets Inserting objects through inlets or outlets is forbidden 8 The unit must not be used in environments where burning sm
3. product be careful not to damage the machine s cables and design finish Take special care when handling the filters See the filter replacement section Check that the product has not been damaged during transport Report any transport damage to the carrier Check also that the delivery is complete 10 2 Air flow details City M Manual Ver 001 September 2014 www canmfil com camitil TECHNICAL MANUAL City M 12 Taking into operation First read the entire Technical Manual Only appropriately qualified electricians may carry out work with electrical connections You must be able to turn off the power supply without touching the unit 1 Connect the air purifier to the electrical outlet Ensure that there is nothing obstructing the air Outlets inlets see figure below how to operate Controller card description 1 Press increase the airflow the blue led indicators will guide you to what airflow you have chosen Press minus to lower the airflow A red warning light will be lit at the filter change symbol when it s time for filter replacement When the red warning light have been lit and filter are replaced you need to calibrate the unit by press an at the same time during 5 seconds Now you are secured that the warning light will be lit again when it s time for filter replacement On the back side of the unit is the electrical connector with fuse holder and machine plate C
4. TECHNICAL MANUAL City M City M Manual Ver 001 September 2014 www canrfil com camitil TECHNICAL MANUAL City M INDEX 1 PURPOSE 2 CONTENTS 3 VERSION HISTORY 4 IDENTIFICATION PLATE 5 GUARANTEES AND UNDERTAKINGS 6 PREFACE 7 TECHNICAL SPECIFICATIONS 8 USE 8 1 WALL AND CEILING MOUNTING 8 2 MOUNTING DRAWING 9 SAFETY INSTRUCTIONS 10 DESIGN 10 1 CONSTITUENT STANDARD COMPONENTS 11 TRANSPORT AND UNPACKAGING 10 2 AIR FLOW DETAILS COIN Oa FF BF WOW WOW WO WO PD 12 STARTING UP YOUR AIR PURIFIER 10 12 1 POSITIONING 10 12 2 SYSTEM INTEGRATION 10 12 3 ELECTRICAL CONNECTION 11 14 PRODUCT AND THE ENVIRONMENT 13 14 1 FILTERS AND THE ENVIRONMENT 13 15 MAINTENANCE 13 16 INSTRUCTIONS FOR REPLACING FILTERS 13 14 16 1 FILTER REPLACEMENT 14 18 EU PROVISIONS GOVERNING THE PRODUCT 15 20 CAMFIL IAQ ANALYSIS 17 City M Manual Ver 001 September 2014 www canrfil com camitil TECHNICAL MANUAL City M 1 Purpose This technical manual is part of the documentation that must be available under appendix 5 of the machine directive The purpose of the manual is to give details of the units design and how it works New users must be able to work safely with this product 2 CONTENTS This manual gives details of the product and must not be used for any other machine Besides short explanations of what the machine is used for the first few sections also g
5. ce on correct care City M Manual Ver 001 September 2014 www canrfil com camitil TECHNICAL MANUAL City M 15 Maintenance lf necessary the unit can be cleaned using a mild cleaning agent Before cleaning always switch off the machine and pull out the electrical connector 16 Instructions for replacing filters WARNING When handling used filters personal protective equipment such as protective gloves and masks must be used To choose the correct type of respiratory protection consult either the safety representative officer at your workplace or the manufacturer of the respiratory protection Used filters may contain harmful substances and particles With incorrect handling these can escape to the environment and present risks of sickness ill health Filters should be replaced on a continuous basis See Camfil AB s recommendations concerning the frequency of filter replacements 16 1 Filter replacement Always use protective gloves and respiratory protection when handling used filters Risk of ill health and sickness 1 Switch off the unit by turning the safety switch 3 Turn the two knobs counter clockwise and lift or remove the electrical connector Make sure up the hatch that the blue operating LED s is off 2 Lift of the top cover of the unit new picture City M Manual Ver 001 September 2014 www canrfil com TECHNICAL MANUAL City M 4 Take a firm grip the pul
6. ity M Manual Ver 001 September 2014 www canrfil com camitil TECHNICAL MANUAL City M 12 1 Positioning The unit must always be positioned and used indoors only Air outlets and intakes must not be obstructed during use Before putting the air purifier in operation ensure there is sufficient space 10 cm around the outlet and inlet 12 2 Electrical connection Electrical connection must be carried out by an appropriately qualified electrician All routing of cables etc must be carried out in accordance with the relevant regulations The unit comes from the factory ready for plugging in Any alterations to the machine s internal electrical systems must only be carried out by appropriately qualified persons using equipment supplied Camfil The unit must only be connected to the network voltage stated on the machine plate identification plate 14 Product and environment The air purifier is made from lead free components It can be recycled Used models must always be sent to a recycling Station for correct recycling and or disposal of parts and components 14 1 Filters and the environment Note that filters must not be disposed of along with ordinary household waste Scrapped filters must always be correctly taken care of and handled safely Recycling or disposal must always be carried out at an approved waste facility If you have any questions about this please contact your local authority or distributor for advi
7. ive some technical specifications After these there are illustrated texts about the various parts that make up this product The user manual also includes details of safety procedures associated with the use of the machine 3 Version history Date signature Altered See approval Initial version 4 Identification plate All Camfil City M air purifiers have the identification plate at the power supply to the unit 5 Guarantees and undertakings The guarantee relates to full functionality as per the details in this User Manual and covers errors in software and hardware for a period of one year from the delivery date Should the equipment develop a fault please contact your distributor Distributor Camfil Svenska AB Industrigatan 3 SE 619 33 TROSA Tel 46 0 156 537 00 Web www camfil com City M Manual Ver 001 September 2014 www canrfil com camifil 6 Preface TECHNICAL MANUAL City M Thank you for buying a high quality air purifier from Camfil We hope that you will be delighted with the use of your Camfil air purifier Important Before using your high quality air purifier it is important that you as the user 1 read this User Manual 2 read the fan instructions and 3 follow the safety instructions in both documents 7 Technical specifications External dimensions vertical model Height 703 mm Width 329 mm Depth 338 mm Weight 16 kg including new filters Filter weight 4 3 kg
8. l the hatch upwards Take a new HEPA filter out of its box Do not touch the filter s surface Hold the handle only Put the filter in its positioning press it down and against the pattern of holes The black gasket must be towards the hole pattern of 5 Grip the handle on top of the filter and pull it the unit towards you Put the filter in a plastic bag Do the same procedure on the other filter and put it in a plastic bag Do steps 1 5 in reverse order City M Manual Ver 001 September 2014 www canmfil com TECHNICAL MANUAL City M 18 EU provisions governing the product This product complies with EU standards as per the Machinery Directive 2006 42 EC the Low Voltage Directive 2006 95 EC and the EMC Directive 2004 108 EC Note that correct observance of the installation and safety instructions is a precondition for the compliance of all operating properties For more details of technical specifications the standards that have been complied with and Camfil s patents please contact Camfil 19 City M Manual Ver 001 September 2014 www canrfil com camifil Camfil IAQ Analysis monitors and measures your air quality in real time IAQ stands for Indoor Air Quality and is a measurement of the quality of indoor air As an additional option for your CamCleaner system you can choose Camfil IAQ Analysis which provides a direct picture of the air qua
9. lity in your rooms We monitor the air quality and all measurements are saved in an IAQ database containing millions of measurement values and benchmarks for the indoor environment and air quality As a customer you have the option to view the analysis in real time at the time of measuring and all measurements can easily be compared with one another A calibrated particle counter can be used to examine the quantity of particles in the air By subscribing to this service you as our customer will always AirImage Reference Platform Fie Edt Windows Close measuring AeroTrak DustTrak P Trak Particles 5 0 10 0ym Mass concentration pgin kira aes lt gt gt 73 00 02 27 3 73 00 02 28 11173 00 02 28 4 City M Manual Ver 001 TECHNICAL MANUAL City M have a particle counter on location that is connected to a computer monitoring the indoor environment When an abnormal particle distribution is identified or in cases of other suspected problems we perform an analysis with a scanning electron microscope SEM with associated X ray analysis system EDAX As required the quantity weight and structure of the particles are analyzed as well as the chemical composition of the air and element content We have more than 10 years of experience from these analyses We also work together with many of the world s leading laboratories for further analysis Our IAQ repor
10. ouldering objects can get into the machine 9 The unit must be used indoors only 10 The unit must be used in the 25 C 60 C temperature range only 14 The unit must not be drenched with water The highest permitted humidity is 85 if a carbon filter is used 12 Follow the filter handling and replacement instructions very carefully Incorrect handling can damage the filter medium and the guaranteed filter class will not be achieved as a result 13 Take great care when handling used filters Incorrect handling can result in ill health or sickness Follow the instructions for filter replacement 10 Design The unit is a self standing one section design housing the filters fan section and all electrical connections The machine is entirely constructed of aluminium and plastic parts and is therefore environmentally friendly and recyclable 10 1 Constituent standard components In its standard version the air purifier is supplied with the following components One CamCleaner City M unit Filters for the chosen purpose Quick guide Technical Manual Fan instructions from the fan supplier Electrical connector VV VV VV If anything is missing or if you require further information about accessories please contact Camfil City M Manual Ver 001 September 2014 www canfil com camitil TECHNICAL MANUAL City M 11 Transport and unpacking Remove the packaging carefully If sharp objects are used to unpack the
11. ts are based on the following standards for air classification SS SS EN ISO and IEST September 2014 www camfil com camitil TECHNICAL MANUAL City M CAMFIL FARR the world s largest and leading manufacturer of filters and clean air solutions There is a good chance that at this very moment you are breathing clean air that has passed through a filter manufactured by us Our products can be found everywhere from offices clean rooms for sensitive electronics production and mines to factories hospitals and nuclear power stations Camfil Farr is a global company with 29 subsidiaries 23 production plants and an extensive network of agents in Europe the Americas and the Asia Pacific region CamCleaner CamCleaner is synonymous with high efficiency purification energy savings and almost silent operation Unlike all other air purifiers on the market our HEPA filters offer a degree of purification that can eliminate the tiniest and most difficult to remove particles CamCleaner is also entirely unique in that it can suck in air from two directions allowing different cleaning zones and increasing the efficiency of air purification considerably City M Manual Ver 001 September 2014 www canrfil com