Home

System Operation

image

Contents

1. Away Stay Instant Maximum Single Button arming If programmed 57 Function Key menu mode lettered keys A D can be used for arming using options 3 AWAY 4 STAY 5 NIGHT STAY or 6 Step Arming If used no security code is required to arm the system Alarm Memory When the system is disarmed any zones that werein an alarm condition during the armed period will be displayed To clear this display simply repeat the disarm sequence enter the security code and press the OFF key again Arming Away Enter code AWAY 2 or simply press appropriate lettered key on the keypads see Single Button Arming above Arming Stay Enter code STAY 3 or simply press appropriate key on the keypads see Single Button Arming above Arming Night Stay Enter code STAY 3 STAY 3 or simply press appropriate key on the keypads see Single Button Arming above Arming Instant Enter code INSTANT 7 Arming Maximum Enter code MAXIMUM 4 or simply press appropriate lettered key on the keypads see Single Button Arming above Disarming Enter code OFF 1 Bypassing Zones Enter code BY PASS 6 zone number s Forced Quick Bypass To automatically bypass all faulted zones use the Quick Bypass method Enter code BYPASS then wait for all open zones to be displayed Arm when display indicates ZONE BYPASSED and READY TO ARM Chime Mode
2. Various System Trouble Displays Alpha Display Fixed Disp Meaning CANCELED ALARM CA will appear if an exit or interior zone contained a fault during closing at the time the Exit Delay ended e g exit door left open but the system was disarmed during the Entry Delay time The alarm sounder and keypad sound continuously but stop when the system is disarmed No message will be transmitted to the central station EXIT ALARM EA will appear when the Exit Delay ends if an exit or interior zone contained a fault during closing The alarm sounder and keypad sound continuously until the system is disarmed or timeout occurs An Exit Alarm message is sent to the central station Also results if an alarm from an exit or interior zone occurs within 2 minutes after the end of an Exit Delay CHECK CHECK indicates that a problem exists with the displayed zone s and requires attention Note The control will sense a high resistance in the loops on hardwired zones 2 8 and display CHECK and the affected zone number when the system is in the disarmed mode It will not be possible to arm the system as long as this condition exists unless this zone is bypassed If the system is in the armed mode when the high resistance condition occurs this display will not appear but will do so as soon as the system is disarmed Check the sensor or the loop wiring for the displayed zone ALARM 1xx FAULT 1xx CHECK 1x
3. Enter code CHIME 9 To turn chime off enter code CHIME again Activate Output Devices If relay outputs via a 4204 or 4229 or Powerline Carrier devices are used two keypad entries available to the user are included If programmed these entries can be used to manually activate or deactivate the device s for starting or stopping some action such as turning lights on or off etc These keypad entries are Security Code 7 2 digit Device activates starts that device Security Code 8 2 digit Device deactivates stops that device SUMMARY OF ARMING MODES Features for Each Arming Mode Arming ae ee a N stay vws Ye il ia ad INSTANT Yes wo oe eS eee only those zones listed in Night Stay zone list Panic Keys There are three Panic keys A B and C that if programmed can be used to manually initiate alarms and send a report to the central station Each key can be programmed for 24 hour Silent 24 hour Audible Fire or Personal Emergency responses The programmed Panic response is activated when the appropriate key is pressed for at least 2 seconds The Panic keys are identified by the system as follows Keys Displayed as Zone A 1 95 B 99 C 3 96 IMPORTANT For a Silent panic function if programmed to be of practical value you must program a report code for the zone and the system must be connected to a central station
4. the system is disabled Alpha Display Fixed Disp Meaning Modem Comm CC The system is in communication with the central station for change of function or status verification no display no display Power Failure If there is no keypad display at all and the LEDs are unlit operating power AC and battery for the system has stopped and the system is inoperative If the message AC LOSS Alpha display keypads or NO AC Fixed Word display keypads is displayed the keypad is operating on battery power only If the battery standby capacity is used up during a prolonged AC power outage the control s power will shut down to minimize deep discharge of the battery Comm Failure FC A communication failure has occurred Open Circuit OC The keypad is not receiving signals from the control and sees an open circuit Long Rng Trbl bF Backup LRR communication failure Bell Failure 70 Bell supervision failure RCVR Jam 90 RF jam detected KEYPAD LOW BAT 00 BAT Wireless keypad low battery Phone Okay Cd The dialer test has been successful CID code 601 Dialer Off dO The dialer is disabled Test in Progress dd Walk test mode is active CID code 607 Upload Completed dC The upload or download session was completed Upload Failed dF The upload or download session failed before completion
5. Security Codes The VISTA 20P system supports up to 48 security codes VISTA 15P supports 32 codes which can each be assigned one of 5 authority levels The authority level determines the functions each code can perform as follows Authority Levels authority levels can be assigned to users 3 49 only users 1 and 2 cannot be changed System Operation Level User No Functions Installer 01 perform all security functions except can disarm only if used to arm can enter program mode default 4112 System 02 only one system master code per system can perform all security Master functions add delete users in either partition change master code view event log set system clock program keypad macro program scheduled events activate output devices triggers relays Partition P1 03 VISTA 20P only Same as Master except add delete users limited to Master P2 33 assigned partition only these users can be assigned different authority default levels if desired any user can be assigned the partition master authority level 0 U ser 03 49 V20P perform security functions arm disarm etc only cannot add del ete 03 33 V15P users view event log set system clock or program scheduled events 1 Arm Only see user armsystem only 2 Guest see user can disarm the system only if it was used to arm the system 3 Duress see user performs security functions but also silently sends a d
6. uress message to the central station reports as zone 92 4 Partition see user VISTA 20P only See Partition Master paragraph above used to assign Master other user numbers as partition masters Refer to the user guide for detailed procedures on adding deleting security codes and changing user attributes The following is a brief description of how to add user codes Adding a User Code Deleting a User Code Assigning Attributes arm disarm Master code 8 2 digit user no user s code Master code 8 2 digit user no 0 Master code 8 2 digit user no attribute no value Attributes Values 1 Authority Level 0 4 see Authority Level table above 2 Access Group 0 8 0 not assigned to a group 3 Active Partition s 1 2 3 common for this user Enter partitions consecutively if more than one and press to end the entries Assigns user number to button type zone for 4 RF Zone No 5 Open Close Paging 1 for yes O for no Keypad Functions The following is a brief list of system commands F or detailed information concerning system functions refer to the User s Manual Function Description Silence alarms Pressing any key will silence the keypad sounder for 10 seconds Disarming the system will silence both keypad and external sounders Quick Arm If enabled field Q21 you can press in place of the system s security code plus the desired arming key
7. x 1xx 1xx 1xx 91 indicates that communication between control and a zone expander or wireless receiver is interrupted where xx is the device address Check the wiring and DIP switch settings on the units If field 199 is set to 1 all ECP module problems are displayed as 91 If there are wireless sensors in the system the Check condition may also be caused by some change in the environment that prevents the receiver from receiving signals from a particular sensor SYSTEM LO BAT BAT with no zone number indicates that the system s main standby battery is weak LO BAT BAT with a zone number and a once per minute beeping at the keypad indicates that a low battery condition exists in the wireless sensor displayed zone 00 indicates a wireless keypad If the battery is not replaced within 30 days a CHECK display may occur Note Some wireless sensors contain a non replaceable long life battery which requires replacement of the entire unit at the end of battery life e g Nos 5802 5802CP TELCO FAULT 94 Telephone Line Failure indicates that a monitored telephone line if programmed in field 92 has been cut or disconnected Depending on how the system was programmed the keypad may also produce a trouble sound and the external sounder may be activated Silence by entering installer code OF F Busy Standby dl If this remains displayed for more than 1 minute

Download Pdf Manuals

image

Related Search

Related Contents

ProForm PFTL313340 Treadmill User Manual  Ficha de Produto  EZ Vinyl/Tape Converter - Quickstart Guide - v2.0  Fruits et arboriculture fruitière  hc1 headset-computer benutzerhandbuch  18.移動電話(pdfファイル:294KB)  Leadenhall Collection Credenza Model  SMOS L1PP Visualization Tool User Manual  LG DVX162 User's Manual  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.