Home

GT15 Printer unit User`s Manual

image

Contents

1. 2005 MITSUBISHI ELECTRIC CORPORATION Compliance with the EMC and Low Voltage Directives When incorporating the Mitsubishi GOT into other machinery or equipment and keeping compliance with the EMC and low voltage directives refer to EMC AND LOW VOLTAGE DIRECTIVE of the GT15 User s Manual The CE logo is printed on the rating plate of the GOT indicating compliance with the EMC and low voltage directives 1 Precautions for connecting the dedicated printer connection cable USB cable Wait 5s or more between the connection and disconnection of the dedicated printer connection cable If connecting or disconnecting the dedicated printer connection cable shortly after disconnecting or connecting the cable the GOT may not operate normally Do not connect or disconnect the dedicated printer connection cable during printing Doing so can cause the GOT operate incorrectly Connected printer may not be recognized in rare cases When printer is not recognized disconnect the dedicated printer connection cable once and connect it again When the printer has been connected to a personal computer and used before it is connected to GOT power on the printer again and connect it to GOT Any printer cannot be connected to GOT via USB hub Do not connect any devices to the printer while GOT is connected to it Do not connect any devices other than printer to the printer unit 2 Cable connection disconnection
2. STARTUP AND MAINTENANCE PRECAUTIONS lt gt DANGER Before starting cleaning always shut off GOT power externally in all phases Not doing so can cause a unit failure or malfunction Undertightening can cause the GOT to drop short circuit or malfunction Overtightening can cause a short circuit or malfunction due to the damage of the screws or unit Do not disassemble or modify any unit This will cause failure malfunction injuries or fire Do not touch the conductive areas and electronic parts of this unit directly Doing so can cause a unit malfunction or failure 4 2 Unit Installation 1 Power off the GOT 2 Remove one extension unit cover of the GOT In the case a cable clamp is attached 4 Fasten the printer unit by tightening its mounting screws 2 places with tightening torque 0 36 to 0 48 In the case a cable clamp is attached 5 When mounting any communication unit on the outer stage refer to GT15 User s Manual When not mounting any communication unit on the outer layer stick accessory stickers on the top of mounting screws 2 places to cover the top of them in order to avoid receiving electrostatic Keep the connector cover and sticker see the following figure fixed Accessory stickers Connector cover Sticker A CAUTION Always secure the cables connected to the unit e g run them in conduits or clamp them Not doing so can cause unit or
3. 15 10 4 21 0 83 12 1 18 0 71 8 4 5 7 23 0 91 Unit mm inch No Name Description Mounting screws fixed with the front 1 Mounting screw communication unit or GOT Holder for preventing a dedicated printer 2 Connector holder connection cable disconnection 3 Cable clamp For cable treatment USB connector for connecting a 4 Connector dedicated printer connection cable 5 Rating plate 4 Installation Procedure 4 1 Cable connection 1 Connect a dedicated printer connection cable to the printer unit 2 Attach the accessory connector holder to the dedicated printer connection cable and tighten the screw of connector holder with tightening torque of 0 36 to 0 48Nem Dedicated printer connection cable 3 Depending on the use environment such as when fastening cable is difficult attach a cable clamp to the printer unit Be sure to attach the cable clamp to section A see the following figure with its band positioned outside and press it until it clicks For the band inserting direction refer to the arrow In the case a cable clamp is attached 4 Insert the dedicated printer connection cable in the looped cable clamp band and pull the band to fasten the cable x Cable clamp DESIGN PRECAUTIONS lt gt DANGER Do not bunch the control wires or communication cables with the main circuit or p
4. 852 2887 8870 China Mitsubishi Electric Automation Shanghai Ltd 4 F Zhi Fu Plazz No 80 Xin Chang Road Shanghai 200003 China Tel 86 21 6120 0808 Taiwan Setsuyo Enterprise Co Ltd 6F No 105 Wu Kung 3rd Rd Wu Ku Hsiang Taipei Hsine Taiwan Tel 886 2 2299 2499 Korea Mitsubishi Electric Automation Korea Co Ltd 1480 6 Gayang dong Gangseo ku Seoul 157 200 Korea Tel 82 2 3660 9552 Singapore Mitsubishi Electric Asia Pte Ltd 307 Alexandra Road 05 01 02 Mitsubishi Electric Building Singapore 159943 Tel 65 6470 2460 Thailand Mitsubishi Electric Automation Thailand Co Ltd Bang Chan Industrial Estate No 111 Moo 4 Serithai Rd T Kannayao A Kannayao Bangkok 10230 Thailand Tel 66 2 517 1326 Indonesia P T Autoteknindo Sumber Makmur Muara Karang Selatan Block A Utara No 1 Kav No 11 Kawasan Industri Pergudangan Jakarta Utara 14440 P O Box 5045 Jakarta 11050 Indonesia Tel 62 21 6630833 India Messung Systems Pvt Ltd Electronic Sadan NO III Unit No15 M I D C Bhosari Pune 411026 India Tel 91 20 2712 3130 Australia Mitsubishi Electric Australia Pty Ltd 348 Victoria Road Rydalmere N S W 2116 Australia Tel 61 2 9684 7777 A MITSUBISHI ELECTRIC CORPORATION HEAD OFFICE TOKYO BUILDING 2 7 3 MARUNOUCHI CHIYODA KU TOKYO 100 8310 JAPAN NAGOYA WORKS 1 14 YADA MINAMI 5 CHOME HIGASHI KU NAGOYA JAPAN When exported from Japan this manual does not require application to the Mi
5. Wait 3s or more between the connecting and disconnecting operations of the dedicated printer connection cable If not waiting 3s or more the GOT may not operate normally 3 Printer unit removal If you remove the Printer unit detach it from specified direction shown PULL so as not to break a connector 4 Cable clamp a Pulling out the cable clamp band The cable clamp band can be pulled out after cable treatment Pull out the band with pressing the tab of the cable clamp outward using a screwdriver etc b Removing from the printer unit The dedicated printer connection cable can be removed from the unit with the cable clamp attached Remove the cable clamp by pressing it in both directions arrow A gt J f 5 Screw of the connector holder Do not remove the screw attached to the connector holder In the case the screw is removed do not use any other screws Doing so may damage the unit Packing List The following items are included Model Product Quantity Printer unit 1 GT15 PRN Mounting screw set 2 pieces of screw 1 2 pieces of sticker Dedicated printer connection cable 3m 1 GTO09 C30USB 5P Cable clamp set Connector holder with 1 screw cable clamp 1 Overview This User s Manual describes the GT15 printer unit With the printer unit installed the GOT can be connected to a printer Use PictBridge compatible printers Printers incompatible with P
6. MITSUBISHI GT15 Printer unit User s Manual GT15 PRN Thank you for purchasing the GOT1000 Series Prior to use please read both this manual and detailed manual thoroughly to fully understand the product MODEL GT15 PRN U MODEL CODE 1D7M47 IB NA 0800334 D 0707 MEE GRAPHIC OPERATION TERMINAL GOTio900 SAFETY PRECAUTIONS Always read these precautions before using this equipment Before using this product please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly The precautions given in this manual are concerned with this prod uct In this manual the safety precautions are ranked as DANGER and CAUTION Indicates that incorrect handling may cause O DANGER hazardous conditions resulting in death or severe injury I I I I I Indicates that incorrect handling may cause i slight personal injury or physical damage Note that the A CAUTION level may lead to a serious accident according to the circumstances Always follow the precautions of both levels because they are impor tant to personal safety Please save this manual to make it accessible when required and always forward it to the end user Dimensions of X when the printer unit is mounted to the GOT I I I I A CAUTION hazardous conditions resulting in medium or l I 1
7. cable damage due to dangling moved or accidentally pulled cables or can cause a malfunction due to a cable contact fault Do not hold the cable part when unplugging any cable connected to the unit Doing so can cause unit or cable damage or a malfunction due to a cable contact fault Do not drop the module or subject it to string shock A module damage may result Always make sure to touch the grounded metal to discharge the electricity charged in the body etc before touching the unit Failure to do so may cause a failure or malfunctions of the unit DISPOSAL PRECAUTIONS CAUTION Dispose of this product as industrial waste TRANSPORTATION PRECAUTIONS CAUTION Make sure to transport the GOT main unit and or relevant unit s in the manner they will not be exposed to the impact exceeding the impact resistance described in the general specifications of the GT15 User s Manual as they are precision devices Failure to do so may cause the unit to fail Check if the unit operates correctly after transportation Manuals The following shows manuals relevant to this product Detailed Manual Manual Number Manual name Model code GT15 User s Manual SH 080528ENG Sold separately 1D7M23 GOT1000 Series Connection Manual SH 080532ENG Sold separately 1D7M26 Relevant Manuals For relevant manuals refer to the PDF manual stored within the drawing software used
8. ict quality control However when installing the product where major accidents or losses could occur if the product fails install appropriate backup or failsafe functions in the system Country Region Sales office Tel USA Mitsubishi Electric Automation Inc 500 Corporate Woods Parkway Vernon Hills IL 60061 U S A Tel 1 847 478 2100 Brazil MELCO TEC Rep Com e Assessoria Tecnica Ltda Rua Correia Dias 184 Edificio Paraiso Trade Center 8 andar Paraiso Sao Paulo SP Brazil Tel 55 11 5908 8331 Germany Mitsubishi Electric Europe B V German Branch Gothaer Strasse 8 D 40880 Ratingen GERMANY Tel 49 2102 486 0 U K Mitsubishi Electric Europe B V UK Branch Travellers Lane Hatfield Hertfordshire AL10 8XB U K Tel 44 1707 276100 Italy Mitsubishi Electric Europe B V Italian Branch Centro Dir Colleoni Pal Perseo Ingr 2 Via Paracelso 12 I 20041 Agrate Brianza Milano Italy Tel 39 039 60531 Spain Mitsubishi Electric Europe B V Spanish Branch Carretera de Rubi 76 80 E 08190 Sant Cugat del Valles Barcelona Spain Tel 34 93 565 3131 France Mitsubishi Electric Europe B V French Branch 25 Boulevard des Bouvets F 92741 Nanterre Cedex France TEL 33 1 5568 5568 South Africa Circuit Breaker Industries Ltd Private Bag 2016 ZA 1600 Isando South Africa Tel 27 11 928 2000 Hong Kong Mitsubishi Electric Automation Hong Kong Ltd 10th Floor Manulife Tower 169 Electric Road North Point Hong Kong Tel
9. ictBridge cannot be used with the GOT 2 Specifications The performance specifications of the printer unit are indicated below The general specifications of the printer unit are the same as those of the GOT Refer to GT15 User s Manual for the general specifications of the GOT Item Specification Internal current consumption 5VDC 09A 0 08kg 0 18lb Including connector Weight holder and cable clamp 3 Part Names and External Dimensions Unit mm inch The external dimensions of printer unit with a cable clamp and connector holder attached is shown above Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi machine damage or lost profits caused by faults in the Mitsubishi products damage secondary damage accident compensation caused by special factors unpredictable by Mitsubishi damages to products other than Mitsubishi products and to other duties A For safe use This product has been manufactured as a general purpose part for general industries and has not been designed or manufactured to be incorporated in a device or system used in purposes related to human life Before using the product for special purposes such as nuclear power electric power aerospace medicine or passenger movement vehicles consult with Mitsubishi This product has been manufactured under str
10. nistry of Economy Trade and Industry for service transaction permission Specifications subject to change without notice Printed in Japan on recycled paper
11. ower wires or lay them close to each other As a guide separate the lines by a distance of at least 100 mm 3 94 inch otherwise malfunctions may occur due to noise INSTALLATION PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before mounting or removing this unit to from the GOT Not doing so can cause a unit failure or malfunction Before connecting the Bus connection cable to this unit always shut off GOT power and PLC CPU power externally in all phases Not doing so can cause a malfunction CAUTION Use this unit in the environment given in the general specifications of the GT15 User s Manual Not doing so can cause an electric shock fire malfunction or product damage or deterioration When installing this unit to the GOT fit it to the connection interface of the GOT and tighten the mounting screws in the specified torque range Undertightening can cause a drop failure or malfunction Overtightening can cause a drop failure or malfunction due to screw or unit damage WIRING PRECAUTIONS lt gt DANGER Be sure to shut off all phases of the external power supply used by the system before wiring Failure to do so may result in an electric shock product damage or malfunctions CAUTION Exercise care to avoid foreign matter such as chips and wire offcuts entering the unit Not doing so can cause a fire failure or malfunction