Contents

1. LEADER LIGHT s r o M Gorkeho 33 052 01 Spisska Nova Ves Slovakia www leaderlight eu LEADER LIGHT LL STAGE 6 06D LL36 080 USER MANUAL COMPLIMENTS ON YOUR PURCHASE All dimensions are in millimeters 600 OO OOOO a Package includes LL STAGE 6 06D with adjustable bracket 1pc PowerCon type A B 1pc User manual 1pc Additional items needed Data cables with XLR 5pin F M 1pc Controller compatible with DMX 1pc Mounting accessories as necessary Content 01 SAFETY INFORMATION 01 1 Risk of eyes damage 01 2 Safety instructions 01 3 Fire protection 02 PRODUCT SPECIFICATION 02 1 Technical specification 02 2 Product description 03 INSTALLATION 03 1 Unpacking 03 2 Physical installation 03 3 Connection 03 4 Control data connection 03 5 DMX channels 04 MAINTENANCE AND SERVICE ENVIRONMENTAL PROTECTION K Do not throw away the appliance with the normal household waste at the end of its life but hand it in at an official collection point for recycling By doing this you help to preserve the environment MMXI LEADER LIGHT All right reserved 01 SAFETY INFORMATION WARNING Carefully read before installing powering or servicing Nothing to do if anything misunderstand Installation can be done only by a qualified professional in accordance with relevant local codes 01 1 Risk of eyes damage Do not look directly into LED lamps Do not look into lig
2. X MODUL 2 45GHz 5 8GHz DMX RDM supply with W DMX antenna MMxXI LEADER LIGHT All right reserved Mechanical mounting of LL STAGE 6 06D Mounting on stage is easy using various accessories as seen below Figures Nr 1 1 to 1 2 The brackets are connect by Camlocs Camloc 1 4 turn fasteners Safe mechanical quick release fastener systems Locking unlocking by quarter turn Hand operated Service friendly time saving and cost cutting Vibration resistant G Q Page 2 2 LL36 300 D aw ee 1 1 Serial connection by LL36 300 for creation of continuous line OO OO OO O Gees AIMING POSSIBILITY The fixture could be aim to wish position with adjustable bracket 1 2 Parallel connection by dual bracket LL36 320 Mechanical mounting of frame to the LL STAGE 6 06D Frame installation without tools Figures Nr 2 1 to 2 2 LMM MUM KS W Eog 2 1 The screws unlock by hand Pick out the frame Edition A 2011 04 MAINTENANCE AND SERVICE A Before any maintenance is necessary to carefully read all SAFETY INFORMATION 01 Damages caused by inadequate cleaning or maintenance are not covered by warranty Requires periodic cleaning dust dirt Procedure for maintenance Unplug main
3. ecification Power connection 100 260V AC 50 60Hz In Out PowerCon IP IP20 DMX 512 In Out with XLR 5pin Ambient temp Ta Maximum 40 C Net weight 6kg Installation Control data Surface mounting Edition A 2011 Page 2 i 02 2 Product description Power In DMX In PowerCon XLR 5pin DMX Out Power Out XLR 5pin PowerCon Data Out Indication of control LEDs LED power green LED data yellow Status O K Device is working correct No DMX signal O K Correct DMX signal Indication blinking 2Hz not lit blinking 4Hz LED Power LED Data LED Data CER DAA fast blinking ERROR Incorrect digital signal LED Power amp E LED Data alternating blinking function AutoTest 03 INSTALLATION 03 1 Unpacking Unpack carefully This is electronic equipment and should be handled carefully Damaged delivered package or if are any mechanical parts broken it must be claim immediately by the transport company Photo pictures as evidence are valuable for future claim 03 2 Physical installation Loading capacity of bearing area has to be at least 10 times the weight of all device clusters Hairbreadth from combustible materials is 0 5m Before physical installation insert the optic modul on front of luminary The optic installation is easy and fast by 2 screws figures Nr 3 1 to 3 2 Respect all SAFETY INFORMATION 01 A Connect the gr
4. ht beam from a distance of less than 40 cm 16 inches 01 2 Safety instructions Shut down power before installation or maintenance Do not modify alter or attempt to service the LEADER LIGHT appliance Doing so will void the warranty Appliance and recommended AC power supply must be installed by a qualified professional in accordance with relevant local codes Use only acceptable source of AC power and frequency that complies with local biulding and electrical codes Use only the recommended voltage source Appliance always connect to earth eltech Do not use or do not connect the products if the power cable power plug or fixtures are any way damaged wet or if they are overheating Before removing or installing any cover or part of appliance disconnect it from AC power AC power supply must be protected against overvoltage and short circuits 01 3 Fire protection Follow all safety restrictions A Thermostatic switches or fuses never to bypass Device never shield Around the axis of the fitting 180 must be maintained space for cooling Minimum distance from the surrounding objects must be 100mm 4 in LEDs never direct cover with filters or other materials Allowing max ambient temperature is 40 C 104 F Luminaries never use without mounting brackets The housing never install directly to the surface x ALX N y AN 6 gt A 02 PRODUCT SPECIFICATION 02 1 Technical sp
5. ound earth Itis not necessary to open the fixture before power supply Power supply is solved simple with Neutrik PowerCon connectors The fixture is equipped with auto switching power supply that automatically adjusts to any 50 60Hz AC power source from 100 260V 03 3 Connection l Symbol Pin Wire Colour Screw US Cord plug connections L live brown yellow or brass N neutral blue silver oe ground earth yellow green green Additional information on support leaderlight sk 03 4 Control data connection Control data cable length is specified by Norm IEC929 Annex E4 It is not necessary to open the fixture before connecting of DMX512 control sig nal Interconnections are realized by Neutrik XLR 5pin In Out connectors Pin connections Pin 1 ground Pin 2 signal negative Pin 3 signal positive 03 5 DMX channels These informations are subject to change latest data are on www leaderlight eu OI Xo mam exeye Product name LL36 080 1 LL STAGE 6 06D W delivery with LL BEAM FRAME STAGE6 Accessories O1 Ko 1o10 Product name LL37 200 1 LL BEAM FRAME STAGE 6 LL37 220 1 LL FRAME STAGE 6 SQ6 LL37 230 1 LL FRAME STAGE 6 R6 LL36 300 1 LL BRACKET STAGE 6 SERIAL LL36 320 1 LL BRACKET STAGE 6 PARALLEL DUAL 2pcs LL36 330 1 LL BRACKET STAGE 6 FIX LL36 340 1 LL BRACKET STAGE 6 ADJUSTABLE LL90 000 W DM
6. s before maintenance and at least 10 minutes cool off Appliance do not illegal open or demount Clean up dust only from outer surface Use vacuum or dumpy duster warm water Before reinstalling make sure everything is intact and dry no wet parts Service Customer service provided by the manufacturer Additional information on support leaderlight sk