Home

Laser Distancer LD 320

image

Contents

1. Le ae a E Operating instructions N m A al toa 7 SJ _ RL A i 7 N l Table of Contents Instrument Set up Prohibited use Introduction Hazards in use Overview ilies s use Display Isposal ner ais Electromagnetic Compatibility EMC 7 FCC statement applicable in U S Operations Laser classification Switching ON OFF Labelling Message Codes Adjusting measuring reference Distance unit setting Beep ON OFF Measuring Functions Measuring single distance Permament measuring Pythagoras 2 point Pythagoras 3 point Minimum Tracking Maximum Tracking Technical Data Warranty Safety Instructions Areas of responsibility Permitted use Stabila LD 320 Instrument Set up Introduction Overview The safety instructions and the user manual should be read through carefully before the product is used for the Display first time The person responsible for the product must ensure that all users understand these directions and adhere to them The symbols used have the following meanings WARNING Indicates a potentially hazardous situation or an unintended use which if not avoided will result in death or serious injury CAUTION Indicates a potentially hazardous situation or an unintended use Area which if not avoided may result in minor injury and or appreci Volume able material financial and environmental damage Pythagoras Important paragraphs which must be
2. machines or installations which are unprotected Aiming directly in the sun FCC statement applicable in U S This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential instal lation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that inter ference will not occur in a particular instal lation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interfer ence by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Hazards in use A WARNING Watch out for erroneous measurements if the instrument is defective or if it has been dropped or has been misused or modified Carry out periodic test measurements Particularly after the instrument has been subject to abnormal use a
3. adhered to in practice Min Max as they enable the product to be used in a technically Tracking correct and efficient manner On Measure Tracking Measuring reference Clear Off Stabila LD 320 Instrument Set up EN Display Insert batteries To ensure a reli cs able use do not use zinc carbon Pythagoras batteries Change batter ies when battery Area lt lt symbol is flash Volume Ss ing Messing e Aod NI UT OO BB ai Panao cues DOEA Brie mie Battery CR Units Main line Stabila LD 320 Operations Switching ON OFF Message Codes gt 2X Ifthe info icon appears with a number observe the instruc tions in section Message Codes Example Leave actual Device is Undo last action function go to de l 2 sec turned OFF fault operation mode Adjusting measuring reference 5 nn Next distance is measured from Distance is measured from the rear the front of the device of the device standard setting Distance unit setting Beep ON OFF 5 Switch between the ww rs following units 0 000m 2 sec 2 sec 0 00m simultaneously 0 00ft 0 00 1 16 cI x 0 00in 0 1 16in 4 Stabila LD 320 Measuring Functions Measuring single distance Target surfaces Measuring errors can occur when meas uring to colourless liquids glass styrofoam or semi per meable surfaces or when aiming at high gloss
4. ange target surface e g white paper 257 Too much back ground light Shadow target area 258 Measurement outside of meas uring range Correct range 260 Laser beam inter rupted Repeat measurement ISO 1633144 hatakin ACCURACY amp RANGE applies for 100 target reflectivity white painted wall low background illumination 25 C applies for 10 to 500 target reflectivity high back ground illumination 0 C to 40 C Tolerances apply from 0 05 m to 10 m with a confi dence level of 95 The maximum tolerance may deteriorate to 0 15 mm m between 10 m to 30 m and to 0 2 mm m for distances above 30 m applies for 100 target reflectivity background illumination of approximately 30 000 lux Stabila LD 320 Care e Clean the device with a damp soft cloth e Never immerse the device in water e Never use aggressive cleaning agents or solvents Warranty Stabila provides a two year warranty for the Stabila LD 320 Futher information can be found on the Internet at www stabila de Stabila LD 320 Distance measuring yes Min Max measuring yes Permanent measuring yes Area yes Volume yes Pythagoras 2 point 3 point Display illumination yes Safety Instructions The person responsible for the instrument must ensure that all users understand these directions and adhere to them Areas of responsibility Responsibilities of th
5. e ST national regulations in force in your country Adhere to the national and country specific regulations Product specific treatment and waste management can be downloaded from our homepage Electromagnetic Compatibility EMC WARNING The device conforms to the most stringent requirements of the relevant standards and regulations Yet the possibility of causing interference in other devices cannot be totally excluded Labelling Laser Radiation Do not stare into the beam Laser class 2 acc IEC 60825 1 2007 Maximum radiant power lt 1mW Emitted wavelength 620 690nm Beam divergence 0 16 x 0 6 mrad Impulse duration 0 2 x 10 s 0 8 x 10 s Subject to change drawings descriptions and technical data without prior notice
6. e manufacturer of the original equipment STABILA Messger te Gustav Ullrich GmbH P O Box 13 40 D 76851 Annweiler Landauer Str 45 D 76855 Annweiler USA Canada STABILA Inc 332 Industrial Drive South Elgin IL 60177 1 800 869 7460 The company above is responsible for supplying the product including the User Manual in a completely safe condition The company above is not responsible for third party accessories Responsibilities of the person in charge of the instrument e To understand the safety instructions on the product and the instructions in the User Manual e To be familiar with local safety regula tions relating to accident prevention e Always prevent access to the product by unauthorised personnel 12 Permitted use e Measuring distances e Tilt measurement Prohibited use Using the product without instruction Using outside the stated limits Deactivation of safety systems and removal of explanatory and hazard labels Opening of the equipment by using tools screwdrivers etc Carrying out modification or conversion of the product Use of accessories from other manufac turers without express approval Deliberate dazzling of third parties also in the dark Inadequate safeguards at the surveying site e g when measuring on roads construction sites etc Deliberate or irresponsible behaviour on scaffolding when using ladders when measuring near machines which are running or near parts of
7. ions usgumy Current Max 4242m measured 4 684m Distance Stabila LD 320 10 Technical Data lance measurement Typical Measuring Tolerance 2 0 mm 0 08 in Maximum Measuring Toler ance 3 0 mm 0 12 in Range at Target Plate 50 m 164 ft Typical Range 40 m 132 ft Range at unfavourable condi 35 m 115 ft tion Smallest unit displayed 1mm 1 16 in laser point 6 30 mm at distances 10 50 m Laser class 2 Laser type 635 nm lt 1 mW Autom laser switch off after 90 s Autom power switch off after 180 s Battery durability 2 x AAA up to 3000 measure ments Dimension H x D x W 100 x 54 x 30 mm 3 94 x 2 13 x 1 18 in Weight with batteries 100 g 3 21 oz Temperature range Storage Operation 25 to 70 C 13 to 158 F 0 to 40 C 32 to 104 F Message Codes If the message Error does not disappear after switching on the device repeatedly contact the dealer If the message InFo appears with a number press the Clear button and observe the following instructions No Cause Correction 204 Calculation error Perform measurement again 252 Temperature too high Let device cool down 253 Temperature too low Warm device up 255 Received signal too weak measuring time too long Change target surface e g white paper 256 Received signal too high Ch
8. nd before during and after important measurements CAUTION Never attempt to repair the product your self In case of damage contact a local dealer A WARNING Changes or modifications not expressly approved could void the user s authority to operate the equipment Limits of use Refer to section Technical data The device is designed for use in areas permanently habitable by humans Do not use the product in explo sion hazardous areas or in aggressive environments Stabila LD 320 Laser classification The device produces visible laser beams which are emitted from the instrument It is a Class 2 laser product in accordance with e IEC60825 1 2007 Radiation safety of laser products Laser Class 2 products Do not stare into the laser beam or direct it towards other people unnecessarily Eye protection is normally afforded by aversion responses including the blink reflex A WARNING Looking directly into the beam with optical aids e g binoculars telescopes can be hazardous CAUTION Looking into the laser beam may be hazardous to the eyes Stabila LD 320 Disposal CAUTION Flat batteries must not be disposed of with household waste Care for the environ ment and take them to the collection points provided in accordance with national or local regulations The product must not be disposed with household waste Dispose of the product appropri ately in accordance with th
9. surfac es Against dark surfaces the measuring time increases The last value mea A A ame w sured is displayed fel 3 N Stops permanent measur Sey _ gt ing Aim active laser at target lt Stabila LD 320 Measuring Functions The result is shown in the main line and the measured 5 S J value above Aim laser at first Aim laser at sec target point ond target point Volume Aim laser at first Aim laser at sec Aim laser at third target point ond target point target point The result is shown in the main line and the measured value above Stabila LD 320 Measuring Functions Pythagoras 2 point The result is shown in the main line and the measured dis tance above Pressing the meas uring key for 2 sec in the function acti Aim laser at up Aim laser rectan 7 vates automatically per point gular at lower Minimum or Maxi point mum measure ment Aim laser at up Aim laser at rec per point tangular point The result is shown in the main line and the measured distance above Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maxi mum measurement Stabila LD 320 Wy Min max measurement E 3 S is also availa Min min Di ble for Py istance thagoras i calculations 2332m Current Min 2841m mure 2 332m Distance N A Min max measurement Q 3 S is also availa li ble for Py Distance thagoras max calculat