Home

EST-64 - GateCrafters.com

image

Contents

1. EST 64 GSM Remote Control Device User Manual Q ESTATE SWING 1ote Control Device New WT009 2 Output 1 Input Specifacations 2 Output Relays 240 Volts 1 Amp 1 Opto Coupler Alarm Input 1224 Volts AC DC 64 Caller ID Users C E Approval Power and Connection Port Oe i 2 4 On Off Switch Power LED Network LED Sim Card Aerial Connector 12 24 Volts AC DC Normaly Open Dry Contacts Ground Normally Closed Contact and turns to Open Contact when activated Normally Opened Contact and turns to Close Contact when activated Alarm Input apply 12 Volts to activate text alert EST 64 GSM Remote Control Device Diagram EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing ontrol Device 1 INTRODUCTION EST 64 GSM Remote Control Device is an electronic board manufactured by Estate Swing that links to a SIMCOM 300 GSM module supplied with it The purpose of this device is to be installed in parallel of the low voltage opening button of an electric gate to enable it to be opened by means of a GSM phone It has a relay whose contact has to be connected in parallel with the button which opens the gate It has a White List of numbers who are enabled to open the phone up to 64 When the EST 64 GSM Remote Control Device receives a call it will check to see if the calling number is in the list If it is in the list it will reject the
2. Activated Z To set the output relay 2 to supply DC voltage when activated please adjust the jumper according to the below diagram EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing ntrol Device Note Relay 2 will supply DC voltage only according to the output DC voltage of adapter used When 24VAC adapter is used the voltage supplied would be 33VDC To set the output relay 2 to use dry contact Default when activated please adjust the jumper according to the below diagram 5 5 RESET THE EST 64 p To reset the unit you can send the following SMS command to the unit Text Command REST XXXXXX XXXXXX stands for 6 digits password based on PWD and it can be changed anytime with CAP command Example To reset the unit with default password 123456 the syntax of the command is the following REST 123456 EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing ntrol Device 6 MOST COMMON PROBLEMS AND SOLUTIONS p Some phones cannot open the gate Verify that they send the caller ID when calling another phone Check that the number you see in the other phone is what you have programmed in the GSM Remote Control Device I have inserted the SIM but the unit doesn t work Check to have removed the PIN request from the SIM If you didn t do it and you have switched on the unit more than 3 times you may need to us
3. Control Device in a place where there is GSM signal coming from the operator you want to use Check it with a phone before proceeding with the installation If you need to install the device in a place with little signal you may consider using an external antenna that we may supply as an option to be purchased separately with 5m cable You should then insert the SIM of the operator you want to use and program in the White List the numbers enabled to open the gate using the command WHL Note You must remove the PIN request from the SIM before inserting it in the unit otherwise the device will not work In order to do so insert the SIM in a phone and disable the PIN request usually there is a security menu that enables you to do so If you don t do it and switch on the unit more than 3 times you will have to reset the PIN using the PUK 4 EST 64 PROGRAMMING INSTRUCTIONS p You can program the EST 64 with SMS commands using your phone It is safe to do so because in addition to the fact that other people may not know the number of the SIM inserted in it we also use a Password that makes it impossible for anybody who doesn t know it to access the system by chance Remember that commands must be CAPITAL LETTERS It is PWD not pwd CAP not Cap etc Don t add spaces or any other character The 2 SMS commands that you will certainly use in the EST 64 GSM Remote Control Device are the following PWD Password WHL White Lis
4. SETTINGS p One of the most important functions is to receive alarms In order to do this properly you must program the administrator numbers turn on the function of the input and tell the EST 64 which are the recipient numbers and who should receive the alert message for the particular input 5 1 1 PROGRAMMING THE ADMINISTRATOR NUMBER The 8 administrator numbers can be programmed with a text command via SMS Text Command TEL N XXXXXXXXXX N stands for administrator number 1 8 position XXXXXXXXXX stands for the phone number you want to program as administrator e To add a number the syntax of the command is the following PWD123456 TEL1 3593334444 Please note that it is possible to program up to a maximum of 16 digits for a number EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing ntrol Device e To check all the administrator number in the list PWD123456 TEL Note Programming the administrator numbers is necessary in order to operate all the below functions and to receive text alerts when the relays activated 5 1 2 SETTING THE RECIPIENT THAT WILL RECEIVE ALERT MESSAGE gp The unit can only send text alerts to 1 or all 8 of the programmed administrator s mobile phone numbers and this function can be changed at any time by sending the following commands by SMS message to the unit Text Command RERN XXXXXXXX XXXXXXXX stands for 8 digits value ON
5. as 393489999888 you should not program the country code 39 If your number has only 9 digits or less it is not a problem The important thing is that you don t exceed 10 digits e To check which is the number in a place of the list PWD123456 WHLO1 e To erase a number PWD123456 WHLO1D e To erase all number PWD123456 WHL99D ACM Access Mode This command allows you to open only to people that are in the white list or to anybody calling the SIM number e PWD123456 ACM0 it is a zero EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing ntrol Device Warning With the above command you allow free access to anybody calling e PWD123456 ACM2 With the above command you allow only people that are in the white list This is the standard and recommended option CAP Change Password Use this command to change the password with a new one that you will chose for your device don t forget it or you will have to send the unit back to us to reset it and this has a cost The CAP command must be issued 2 times to be sure you don t digit a wrong one Of course it must be preceded by the old password For example to change the password 123456 into the new password 333444 you need to send the following SMS e PWD123456 CAP333444 CAP333444 You will receive a confirmation with CAP OK if you wrote correctly GOT Gate pulse time This command is useful in case y
6. 1 or OFF 0 for the 8 administrators For example if you assume only administrators 1 2 3 and 4 are to receive text alerts you would send the following SMS message to the unit e PWD123456 RERN 11110000 Note You can only put 1 in the first 4 digits of the text command if there are only phone numbers stored in TEL1 TEL2 TEL3 and TEL4 The rest should be 0 e To check the setting of which recipient will receive alert messages PWD123456 RER 5 1 3 EDITING THE INPUT ALERT MESSAGE gp The Input Alert Message can be edited and programmed up to 100 characters long You can change the displayed text by sending the following commands by SMS message to the unit Text Command EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing ntrol Device STR XXXXX XXXXX stands for the display text that you want to program For example if you want the alert message to display Garage Opened when received a text alert you would send the following SMS message to the unit e PWD123456 STR Garage Opened 5 1 4 TURN ON THE FUNCTION OF INPUT gp To turn on the function of input you can send the following commands by SMS message to the unit Text Command CTR X X stands for ON 1 or OFF 0 value e To turn on the input the syntax of the command is the following PWD123456 CTR 1 5 1 5 SETTING THE COUNTER ALERT VALUE FOR INPUT p An alert message will be sent
7. THE OPERATING TIME FOR OUTPUT RELAYS p The output relay can be programmed to operate at a programmable time To program this function you can send the following commands by SMS message to the unit Text Command SMW SS MM HH TTT G R SS is a 2 digits value stand for seconds MM is a 2 digits value stands for minutes HH is a 2 digits value stand for hours TTT is a 3 digits value stand for Turn Off time in seconds G stands for Group number 1 8 R stands for Relay number 1 or 2 Example 1 assume you want output relay number 1 to turn off for 20 seconds on 8 30am you would send the following SMS message to the unit e PWD123456 SMW 00 30 08 020 1 1 EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing ntrol Device Example 1 assume you want output relay number 2 to turn off for 30 seconds on 5 30pm you would send the following SMS message to the unit e PWD123456 SMW 00 30 17 030 1 2 Note You can program up to 8 group of time section for each relay 5 3 3 TIME SETTING gp To set the time you can send the following SMS command to the unit The time is entered in 24 Hour format Text Command TSET SS MM HH SS stands for 2 digits value Seconds MM stands for 2 digits value Minutes HH stands for 2 digits value Hour Note Time setting is necessary for operating function 2 at 5 3 1 5 4 Setting the Output Relay 2 to Supply Voltage or use Dry Contact when
8. call so there will be no charge at least with today s charging procedures and click the relay momentarily 2 ADVANTAGES OF EST 64 GSM REMOTE CONTROL DEVICE gp 1 Safe nobody can clone your phone as easily as they can do with a standard remote control 2 Flexible you can add or remove anybody number in a minute with an SMS 3 Cheap you don t need to buy a remote control for each member of your family 4 Convenient no matter if you change car or if you have different gates to open Your phone will always be with you all the times your remote controls were somewhere else 3 EST 64 GSM REMOTE CONTROL DEVICE OPERATING INSTRUCTIONS p Installation To install the EST 64 GSM Remote Control Device you need to connect the 2 wires of the relay contact in parallel with the gate opening button The relay contact can stand 48V 1A maximum this is enough for its operation but don t try to switch higher voltages or currents You also need to provide the power by means of 12 to 20 VAC or 12 to 26 VDC The power supply must be able to stand 2A We supply a proper AC adapter If you are not using our AC adapter make sure the power supply can arrogate 2A Don t use telephone EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing ntrol Device battery chargers Most of them rely on the phone battery and are unable to supply the power needed You should install the EST 64 GSM Remote
9. e the PUK Check with SIM instructions for details I don t get a response to my texts Try turning the on off switch off and then back on this will reset the network connection If that doesn t work check to be sure the SIM card is a GSM SIM card Sprint Nextel and TrackPhone do not use GSM technology for their SIMs Is it possible to open to anybody Yes you can do it using the ACM command Programming went through properly but the gate will not open by calling the receiver Check your wiring to your gate opener If that is fine then try reprogramming with a 1 in front of all the numbers Some networks add the 1 automatically to caller ids so without the 1 programmed in the number wont be recognized Warranty p7 Estate Swing warranties all EST 64 GSM Remote Control Device against defective parts and workmanship for 1 year Estate Swing shall at its option repair or replace the defective equipment upon the return of such equipment to any Estate Swing branch This warranty applies ONLY to defects in components and workman ship and NOT to damage due to causes beyond the control of Estate Swing such as incorrect voltage lightning damage mechanical shock water damage fire damage or damage arising out of abuse and improper application of the equipment Note Please obtain an RA number through an Estate Swing technician before return WARNING For safety reasons only connect equipment with a telecommunications compliance label Thi
10. elay has turned on off This is to notify the administrators when someone outside the list activates the relays 5 3 SPECIAL FEATURES FOR OUTPUT RELAYS p 5 3 1 SETTING THE OPERATING FEATURE FOR OUTPUT RELAYS p The output relays can be programmed to operate with special feature After programmed it will activate both the output relays to stay on When the unit receives a call from the user it will turn off relay for a certain time period and turn on again To program this function you can send the following commands by SMS message to the unit Text Command FTRY F F stands for function O 2 Function Descriptions Function 0 e This function is disabled Normal Mode Default EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing Function 1 e Relay 1 will turn off for 10 seconds and turn on again After 30 seconds Relay 2 will be off for 5 seconds and turn on again Function 2 e At a programmable time section Relay 1 or 2 will turn off for a programmable time in seconds and turn on again Note Once this function is used the relays will operate automatically according to the programmed time Activation of relays with call will not work this time For further setting of time and operating time please refer to 5 3 2 and 5 3 3 e To program the output relays to operate with function 2 the syntax of the command is the following PWD123456 FTRY 2 5 3 2 SETTING
11. ion as counter e Activate the output relay 2 for 1 second e Sends a counter alert message once alarm counter reaches the alert value Function 5 e Sends an alert message once triggered EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing ntrol Device For example assume you want it to send an alert message each time the input triggered you would send the following SMS message to the unit PWD123456 CTC 5 5 1 7 READING THE TOTAL INCREMENT COUNTER VALUE p To read the total increment counter value you can send the following SMS message to the unit Text Command COU e The syntax of the command is the following PWD123456 COU You will receive the total increment value from the unit by SMS 5 1 8 READING THE TOTAL COUNTER VALUE p To read the sub increment counter value you can send the following SMS message to the unit Text Command COT e The syntax of the command is the following PWD123456 COT You will receive the sub increment value from the unit by SMS Note The sub increment counter value will be reset automatically each time the alarm counter reached the alert value EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing 5 1 9 RESET THE TOTAL COUTER VALUE To reset the total counter value you can send the following SMS message to the unit Text Command CLA e The syntax of the co
12. mmand is the following PWD123456 CLA 5 2 OUTPUT SETTINGS Oooo 5 2 1 ACTIVATE THE OUTPUT RELAY TO STAY ON FOR A SPECIFIC TIME To activate the output relay you can send a text command via SMS specifying the number of seconds the output should stay on to the unit It is possible to set up to maximum of 65 535 seconds Text Command RLY N XXXXX N stands for number 1 or 2 of Output XXXXX stands for 5 digits value The number of seconds For example assume you want to turn on the output relay number 2 for 1 hour you would send the following SMS message to the unit PWD123456 RLY2 03600 e To check the status of output relay PWD123456 RLY Note The reply message will be send to the recipients The Administrators only when the relay has turned on off This is to notify the administrators when someone outside the list activates the relays EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing 5 2 2 ACTIVATE THE OUTPUT RELAY TO STAY ON To activate the output relay to stay on you can send the following commands by SMS message to the unit Text Command RLOP N X N stands for number 1 or 2 of Output X stands for ON 1 or OFF 0 value e To activate the output relay number 2 to stay on indefinitely the syntax of the command is the following PWD123456 RLOP2 1 Note The reply message will be send to the recipients The Administrators only when the r
13. ou need to keep the button pressed longer The standard time is 1 second Maximum 60 seconds where 01 1 second 06 60 seconds You can change it with the GOT command The syntax of the command is the following e PWD123456 GOT02 With the above command the opening time has been set to 2 seconds CSQ Check GSM signal quality This command is useful to see what is the GSM network signal level your EST 64 GSM Remote Control Device is receiving If you send the command PWD123456 CSQ You should receive an SMS with signal quality in range O to 31 if it is O we doubt it will ever answer You should have a signal above 12 to be sure of being able to open the gate in any condition Better if above 16 You should add an external antenna if this is EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing yntrol Device not the case or eventually even change operator with another that serves your area better ADDITIONAL INPUT amp OUTPUT PROGRAMMING INSTRUCTIONS The EST 64 also comes with additional 1 Input and 1 Output The output is connected to an on board relay which can be activated by sending an SMS command The Input can be used to generate alarms when triggered It also can be programmed to count the input active pulses up to ims fast or activate the output relay Note When used as counters input work only in ACTIVE HIGH mode They count ONLY High Going Pulses 5 1 INPUT
14. s includes customer equipment previously labelled permitted or certified EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing
15. t adds or removes numbers You could also use the following though not necessarily ACM Access Mode CAP Change password EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing GOT Gate pulse time CSQ Check Signal Quality Once you issue a command with an SMS you will receive a confirmation SMS with OK if everything is correct or Error if there is an Error PWD Password This command must always come first Use 6 digits as a password The standard default one when the device comes from the factory is 123456 We suggest that you change it using the CAP command In all the following examples we will use 123456 as an example of password WHL White List This is the command that you will use most It is used to add or remove numbers that are enabled to open the gate into the White List You can add up to 64 numbers in the list Every position must be indicated in the command and we advise you to keep a list written somewhere to know which numbers are in and in which position e To add a number the syntax of the command is the following PWD123456 WHLO1 3593334444 Where 01 is the position in the list and 3593334444 is the number enabled Please note that it is possible to program up to a maximum of 10 digits for a number If it has more digits you should use the rightmost ones For example if your number is 33446665555 you should program 3446665555 If your number appears
16. when the increment of alarm counter reaches the alert value Default 500 It is possible to set the alert value up to maximum value of 65535 times To set the counter alert value of input you can send the following commands by SMS message to the unit Text Command COA XXXXX XXXXX stands for 5 digits value The number of times For example assume you want it sends a counter alert message each time the input has triggered for 5 times you would send the following SMS message to the unit EST 64 USER MANUAL Rev 2 4 Technical Support 1 800 640 4283 COPYRIGHT 2008 Estate Swing e PWD123456 COA 00005 5 1 6 SETTING THE FEATURE FOR INPUT p This input can be programmed to behave differently it can count the input active high pulses generate an alarm message or activate relay To program the input you can send the following commands by SMS message to the unit Text Command CTC F F stands for input function 1 5 Function Descriptions Function 1 e Function as counter e Sends a counter alert message once alarm counter reaches the alert value Function 2 e Function as counter e Activate the output relay 2 to stay on e Sends a counter alert message once alarm counter reaches the alert value Function 3 e Function as counter e Activate the output relay 2 to stay on e Sends an alert message once triggered e Sends a counter alert message once alarm counter reaches the alert value Function 4 e Funct