Home

GX60 I/O Base Unit (Expandable I/O), GX90EX

image

Contents

1. Hjo D Of 427 8 5 03 S Dimensions of fixing hole 1560 2 1620 2 6 4 5 hole or M4 y 6 14 0 0078 l 6 38 0 0078 t 0 24 60 18 hole or M4 148 0 4 5 8340 0157 Unit mm approx inch Unless otherwise specified tolerance is 3 however tolerance is 0 3 mm when below 10 mm All Rights Reserved Copyright 2014 Yokogawa Electric Corporation GS 04L53B00 01EN Oct 27 2014 00 Normal Operating Conditions Power supply voltage 100 to 240 V AC 10 Power supply frequency 50 60 Hz 2 Ambient temperature 0 to 50 C Ambient humidity 20 to 80 RH at 5 to 40 C no condensation Magnetic field 400 A m or less DC and 50 60 Hz Vibration 5 lt f lt 8 4 Hz amplitude 3 5 mm peak 8 4 lt f lt 160 Hz acceleration 9 8 m s or less Shock IEC 60068 2 27 Non energization 500 m s or less approximate 10 ms 6 directions X Y Z Mounting position Can be inclined up to 30 degrees backward Left and right horizontal when installing the panel mount and wall mount Altitude 2000 m or less Installation location Indoors Warm up time At least 30 minutes after power on Transport and Storage Conditions Ambient temperature 25 to 60 C Ambient humidity 5 to 95 RH no condensation Vibration 10 to 60 Hz 4 9 m s maximum Shock 392 m s maximum in packaged condition Effects of Operating Conditions Power supply variation Shall satisfy the accuracy specif
2. General exec SMART 0 ifi i I O Base Unit Expandable I O ification Specifications pid reac GS 04L53B00 01EN Expansion Module E OVERVIEW GX60 I O Base Unit Expandable I O The GX60 provides a function to expand an I O module for recording and controlling when it is connected to the expansion module that is connected to the GX10 GX20 GP10 GP20 using a LAN cable via a private communication network e One GX60 can connect up to six I O modules e Up to six units can be additionally connected to the GX GP e The communication distance between the GX GP and GX60 or between GX60s can be extended by up to 100 m using a LAN cable GX90EX Expansion Module The expansion module is connected to the GX10 GX20 GP10 GP20 GX60 GM main unit and GM sub GX60 unit If GX9O0EX expansion module is connected to the GX GP or I O base unit e The expansion module which is supported by the GX GP and GX60 enables a connection between GX GP and GX60 or a communication between GX60s e Adistributed arrangement with the data time synchronization secured is provided by connecting Expansion modules connected to the GX GP main unit and GX60 using a LAN cable e Data is transferred to the high order GX GP via the expansion module If GX9O0EX expansion module is connected to the GM main unit sub unit e The expansion module which is supported GX90EX by the GM main unit and sub unit enables a connection between GM main unit and
3. Directive Compliant Construction All Rights Reserved Copyright 2014 Yokogawa Electric Corporation Front panel terminal Water and dust proof Complies with IEC529 IP20 Material Polycarbonate Color Front Charcoal grey light CC28 Bezel Smoke blue CC53 Dimensions 45 mm W x 100 mm H x 133 mm D D including terminal cover Weight Approx 0 18 kg Power Supply Suppy from GX GP GX60 expandable I O or GM90PS power supply module e Power consumption 1 8W or less External Dimensions A Unit mm approx inch a 107 1 82 1 3 23 31 9 _ gt 45 1 1 78 3 0 12 B y ste 700 3 94 0 Normal Operating Conditions For normal operating conditions of this module please refer to the General Specifications of the device GX GP I O Base Unit or GM that this module is mounted GX Specifications GS 04L51B01 01EN GP Specifications GS 04L52B01 01EN I O Base Unit Expandable I O This General Specifications GM Specifications GS 04L55B01 01EN Transport and Storage Conditions e Ambient temperature 25 to 70 C e Ambient humidity 5 to 95 RH no condensation e Vibration 10 to 60 Hz 4 9 m s maximum e Shock 392 m s maximum in packaged condition Effects of Operating Conditions None GS 04L53B00 01EN Oct 27 2014 00 E MODEL AND SUFFIX CODES MODEL a
4. or product names are registered trade mark of their manufactures All Rights Reserved Copyright 2014 Yokogawa Electric Corporation GS 04L53B00 01EN Oct 27 2014 00
5. sub unit or a communication between sub units e Adistributed arrangement with the data time synchronization secured is provided by connecting Expansion modules connected to the GM main unit and sub unit using a LAN cable e Data is transferred to the high order GM10 via the expansion module Yokogawa Electric Corporation YOKOG AWA 2 9 32 Nakacho Musashino shi Tokyo 180 8750 Japan Power inlet type GS 04L53B00 01EN Copyright April 2014 3rd Edition Oct 27 2014 E GX60 SPECIFICATIONS Module Connection e I O module Max 6 modules Slots 0 to 5 Restrictions e Up to 10 GX90YD digital output modules and GX90WD digital input output modules can be installed together in the GX GP and GX60 e One GX90WD digital input output module can be installed in the GX GP and in each GX60 e Expansion module 1 module Slot EXT for connection with Expansion module Names of Channels e The module installed in the GX60 has a channel name that consists of the unit number slot number and channel number Channel name EAEE Unit number Slot number Channel number I O modules OUL E Channel number Analog input 01 to 10 Digital input 01 to 16 Digital output 01 to 06 Digital input output DI 01 to 08 DO 09 to 14 Slot number 0 to 5 Unit number 1 to 6 All Rights Reserved Copyright 2014 Yokogawa Electric Corporation Safety and EMC Standards CSA CSA22 2 No 61010 1
6. ge range 90 to 132 180 to 264 VAC Rated power supply frequency 50 60 Hz Power consumption Supply voltage Normal operation 100 VAC 20 VA 240 VAC 30 VA When using 6 analog input modules Allowable interruption time Less than 1 cycle of the power supply frequency GS 04L53B00 01EN Oct 27 2014 00 Isolation External Dimensions e Insulation resistance Between each insulation Power screw terminal type terminals and earth 20 MQ or greater at 500 VDC e Withstand voltage Between the power terminal and earth 3000 V AC at 50 60 Hz for one minute Between the input output modules and earth 412 5 16 2 Depends on the specification of I O module 48 156 6 14 4 62 6 38 e Grounding Be sure to set a low grounding 1 89 6 05 hole l resistance _ 6 90 2 hole E isol ation Gs a em CoD COD 25 N LH he H HA H H Power zi terminal Input and output module internal circuit Earth PE terminal Internal circuit The circuits divided by lines are insulated mutually S i 5 03 O 412 5 16 2 48 156 6 14 162 6 38 1 89 6 05 hole LHI HH HI H HIH mS S EH S
7. ication in the range of 90 to 132 VAC or 180 to 250 VAC frequency 50 60 Hz Power supply frequency fluctuation Shall satisfy the accuracy specification in the range of rated supply frequency 2 Hz power supply voltage 100 VAC All Rights Reserved Copyright 2014 Yokogawa Electric Corporation E GX90EX SPECIFICATIONS Communication Functions Communication between GX GP and GX60 between GX60s between GM main unit and sub unit between GM sub units via dedicated communication network Baud rate 10Base T 100Base TX Auto 1 Number of ports 2 Connection cable STP cable CAT5 or greater Inter module connection Cascade connection Ring connection is disabled Maximum communication distance 100 m Connector RJ 45 1 Can be fixed to 10Base T by DIP switch settings Display Functions System status LED indicators RDY green Lights up when the CPU is running normally MASTER green Turns on in master mode and off in slave mode FAIL red Lights up when a system error occurs 7 segment LED indicator Indicates a unit number or operation error Ethernet status indicator LED LINK ACT green SPEED orange Address Setting Functions Switch settings 10 Mpbs 100 Mbps switching a a MASTERISLAVE switching Master Slave Functions Can be set to master mode when installed in the GX GP or GM main unit or slave mode when installed in the GX60 or GM sub unit using the DIP switches 10 Mbps F
8. installation category Il 1 pollution degree 2 7 UL UL61010 1 CSA NRTL C CE EMC directive EN61326 1 compliance Class A Table 2 EN61000 3 2 compliance EN61000 3 3 compliance EN55011 Class A Group 1 Low voltage directive EN61010 1 Installation category II Pollution degree 2 7 EMC Regulatory Arrangement in Australia and New Zealand RCM EN55011 compliance Class A Group 1 KC marking Electromagnetic wave interference prevention standard electromagnetic wave protection standard compliance Installation category overvoltage category II Describes a number which defines a transient overvoltage condition Implies the regulation for impulse withstand voltage IP applies to electrical equipment which is supplied from the fixed installation like a distribution board 2 Pollution degree 2 Describes the degree to which a solid liquid or gas which deteriorates dielectric strength or surface resistivity is adhering 2 applies to normal indoor atmosphere Normally only non conductive pollution occurs WEEE Directive Compliant Construction Front panel terminal Water and dust proof Complies with IEC529 IP20 Material Polycarbonate aluminum alloy Color Front Charcoal grey light CC28 Bezel Smoke blue CC53 Dimensions 412 5 mm W x 164 7 mm H x 127 8 mm D Weight Approx 3 2 kg installing 6 modules Power Supply Rated supply voltage 100 to 240 VAC Allowable power supply volta
9. ixed Mode Can be set to the 10 Mbps fixed mode using the DIP switches Mounting Can be mounted in the GX GP GX60 GM main unit and GM sub unit Mounting position GX10 GP10 Slot 2 GX20 GP20 Slot 9 GX60 EXT slot GM main unit Leftmost position GM sub unit Next to the power supply module GS 04L53B00 01EN Oct 27 2014 00 Safety and EMC Standards CSA CSA22 2 No 61010 1 installation category II pollution degree 2 7 UL UL61010 1 CSA NRTL C GE EMC directive EN61326 1 compliance Class A Table 2 EN61000 3 2 compliance EN61000 3 3 compliance EN55011 Class A Group 1 Low voltage directive EN61010 1 Installation category II Pollution degree 2 7 EMC Regulatory Arrangement in Australia and New Zealand RCM EN55011 compliance Class A Group 1 KC marking Electromagnetic wave interference prevention standard electromagnetic wave protection standard compliance 1 Installation category overvoltage category Il Describes a number which defines a transient overvoltage condition Implies the regulation for impulse withstand voltage II applies to electrical equipment which is supplied from the fixed installation like a distribution board 2 Pollution degree 2 Describes the degree to which a solid liquid or gas which deteriorates dielectric strength or surface resistivity is adhering 2 applies to normal indoor atmosphere Normally only non conductive pollution occurs WEEE
10. nd SUFFIX Code GX60 Model Sufincods O oeno OOOO exo Power cord IS provided One GX90EX I O expansion module MODEL and SUFFIX Code GX90EX voeson Cpe o C wseaearc EN N Always N E Optional Accessories Sold Separately The dummy cover is for empty slots on GX GP and GX60 The dummy cover is not attached to the GX60 when shipped from the factory If you need the dummy cover please purchase it separately Dummy cover B8740CZ Test certificate QIC sold separately When ordering the GX60 GX90EX gets its own QIC one QIC per unit When ordering the expansion modules separately each module gets its own QIC one QIC per module User s Manual Product user s manuals can be downloaded or viewed at the following URL To view the user s manual you need to use Adobe Reader 7 or later by Adobe Systems URL www smartdacplus com manual en Trademarks The TCP IP software used in this product and the document for that TCP IP software are based in part on BSD networking software Release 1 licensed from The Regents of the University of California e SMARTDAC and SMARTDACPLUS are registered trademarks of Yokogawa Electric Corporation e Microsoft MS and Windows are registered trademarks of Microsoft Corporation USA e Pentium are registered trademarks of Intel Corporation e Ethernet is a registered trademark of XEROX Corporation Modbus is a registered trademark of AEG Schneider e Other company and

Download Pdf Manuals

image

Related Search

Related Contents

Dentisterie restauratrice/cosmétique  EST EST3 v4.0 Installation Sheets  Aide à l`utilisation de ce lien  Installation Manual  Manuel utilisation optris PI  PCI2394 User`s Manual  Harbor Freight Tools Medium Barrel Air Impact Hammer Product manual  Analyse de profession pour le métier d`opératrice ou    Planet Technology 2-Bay User's Manual  