1. Config menu you can change the username and password used to access the web server Maximum length for both fields is 11 symbols If you forget your credentials you can perform a hardware reset to recover default settings Username root Password admin When you click the Save Config button a validation check is performed If there is invalid data in one or more fields they will be colored in red If all the input data are correct Radina Tau will save the parameters and will reboot with the new configuration Inova bg Ltd 2011 Page 13 or 15 Radina Tau User Manual v1 2 6 Reboot Inova bg Ltd Radina Tau Radio amp Ethernet Security Home Device is rebooting Your settings were successfully saved and the device is now rebooting to configure itself with the new settings Device Config Login Config Your board is now located at Reboot Copyright 2011 Inova bg Ltd If you choose the Reboot menu this will cause the device to restart 7 Hardware reset In case you changed the settings and can t reach the device or if you forgot your username or password Radina Tau is capable to return to its factory defaults For this purpose you must disconnect from power supply push and hold the button for hardware reset and reconnect to the power supply Hold the button for 5 seconds until the green LED is blinking Once the LED goes off you can release the button and connect to the device Inova bg
2. Features Power supply 12VDC 8 5V to 16V e Low power consumption 0 08A under normal operation and from 0 9 to 1 5A when transmitting through radio channel e Frequency range from 400MHz to 470MHz e RF Output power 5 6W in the whole RF range Bandwidth 12 5KHz IP Server LED One main and up to four back up LAN Status frequencies Configurable parity check RF messages repeat count RF test repeat count repeat count in a single message test period and repeat until restore period e Usage of a Smart Test to reduce radio transmitting e Network interface IEEE 802 3 Ethernet Fully Compatible with 10 100 1000Base T Networks e Static or dynamic IP address compatible with DHCP server LAN e Capability to use one or two fully Input 6 independent IP servers Input 5 Input 4 Input 3 Input 2 Input 1 GND 12V Radio LED Test Button Inova bg Ltd 2011 Page 3 or 15 Radina Tau User Manual v1 2 e Encrypted connection with IP servers e Verification with an unique ID code e HTML server for easy configuration and status check protected with an username and a password e Capability to change the username and password of the html server e Indication 4 LEDs for Radio LED blinks under normal operation ON when transmitting radio message OFF while waiting after transmission LAN Status Ethernet available LAN Activity Network packets service IP Server LED E
3. Ltd 2011 Page 14 or 15 Radina Tau 8 User Manual v1 2 How to determine the height of the antenna The height of the antenna is determined by the radio frequency If you use more than one radio frequency make a compromise between all the frequencies Put the antenna on its place remove the plastic cap on the top start measuring from the end of the box Height cm 7500 Frequency MHz Lem 7500 Frequency Fuuz 400 0000 MHz 410 0000 MHz 420 0000 MHz 430 0000 MHz 440 0000 MHz 450 0000 MHz 460 0000 MHz 470 0000 MHz Formula 7500 400 7500 410 7500 420 7500 430 7500 440 7500 450 7500 460 7500 470 Windows Network configuration If you want to access the web server your computer must be in the same IP subnet You Height of the antenna Lem 18 75 cm 18 29 cm 17 86 cm 17 44 cm 17 05 cm 16 67 cm 16 30 cm 15 96 cm must change the settings of your network adapter 1f they are different than needed If your computer is in a different network than 192 168 1 xxx with mask 255 255 255 0 you will need to change your current configuration of Windows network Start gt Control Panel gt Network and Sharing Center gt Change adapter settings gt Right Click on your network adapter gt Properties gt Right Click on Internet Protocol Version 4 gt Properties gt Use the following IP address IP Address 192 168 1 xxx xxx 1s between 2 and 254 and must be differe
4. Radina Tau User Manual v1 2 Inova beg Ltd Radina Tau Inova bg Ltd 2011 Radina Tau User Manual v1 2 Table of contents 1 2 3 4 4 1 4 2 4 3 4 4 4 5 4 6 pe eco xsb Sv f lunu c re err 3 Start Working with Radima Tala a le a ele imla ay gt FIOMIC PAC EET 6 ets ki e asidi ekme kekik say Soria alay P ERR DIS 7 CCMA SGU o balbal 7 SEMIS for the T0110 EO STEU EC E eei onn recor e ER Dedi bad mau der E 8 General IP Sets sooo en s bab Bl Ba ll az 9 Semmes oricinal 10 SCION S Tor the dieta put e YE 11 Saving he New COnN SUr Oi ees tci c Rat eimi aM iud S 12 Username and passwotd confieuratlOn s eiie a ote elli Ee Rhe eli dadda 13 luo E p ee Re ee 14 n 14 How to determine the heightor Tic antenna soie ox 15 se vor COM OUT AT ilan 15 Inova bg Ltd 2011 Page 2 or 15 Radina Tau User Manual v1 2 l Main features Radina Tau is a communication device with the main purpose to transmit data from security panels and or sensors through UHF radio channel and or IP based network Combining the advantages of those two advanced communication technologies Radina Tau provides the most secure connection with monitoring center using various ways of back up main and up to 4 back up UHF radio frequencies and up to 2 IP servers
5. ation of the main parameters Login Config Configuration of username and password for web server access Reboot Restart the device Inova bg Ltd 2011 Page 6 or 15 Radina Tau User Manual v1 2 4 Configuration of the main parameters 4 1 General settings Inova bg Ltd T l Radio a Ethernet Security Home Radina Tau Configuration This page allows to configure Radina Tau settings Device Config Login config MIU General Settings Reboot x Device Name Radina Tau Account Number TITJ i Use Radio Transmitter amp Network Device Name Enter the name of the device This value is used only for user convenience to identify devices if you have more than one connected to one network Maximum length 30 symbols Account Number Used in radio and in network transmission The first 3 symbols must be from 0 to 7 The last symbol must be from 6 to 9 or from A to J In the monitoring software you can select how to use the last symbol as a digit or as a letter Select working mode Use Radio Transmitter amp Network Transmit data messages through radio and IP network simultaneously Use Radio Only Transmit data messages only through radio Network communication is used only for configuration Use Network Only Transmit data messages only through IP Network If you choose Use Radio Only IP settings are deactivated except the ones which are needed to access the web serve
6. m 1 to 15 Default 6 Repeat Test Count Determines how many times the test message will be transmitted through the radio channel Must be from 1 to 15 Default 1 Inova bg Ltd 2011 Page 8 or 15 Radina Tau User Manual v1 2 Repeats in message Determines how many times the word is repeated in one message In most cases it s not necessary to change this parameter Must be from 6 to 15 Default 8 Test Period Determines the time period in hours between test messages Must be from 1 to 255 Default 6 TUR Period Transmit Until Restore Period Determines how often time period in minutes to repeat the alarm message until the corresponding digital input 1s not restored This option can be enabled separately for each digital input 4 3 General IP settings Network Settings Obtain an address automatically via DHCP Use the following IP address IP Address 192 168 1 230 Gateway 132 168 1 1 Subnet Mask 25 255 256 This settings are active even when working in Use Radio Only mode because they are important for web server access IP settings Obtain an IP address automatically via DHCP IP address is received automatically from a DHCP server in the current network In this case easy way to access the web server is by entering the following address http radinatau If you select this mode but after reboot the device cannot find a dhcp server for more than 10 seconds Radi
7. mit on backup Determines whether to send messages for this input on back up channel or not Repeat Alarm Transmit Until Restore TUR Determines whether to repeat messages for this input until it is in alarm state using the TUR Period field to make pauses between repeats In the network settings for each input you can set the following parameters Type Choose a message which will correspond to the change of state of this input Partition two symbols each from 0 to 9 and from B to F and Zone three symbols each from 0 to 9 and from B to F determines the corresponding parameters for the messages generated from each digital input 4 6 Saving the new configuration When you click the Save Config button a validation check is performed If there is invalid data in one or more fields they will be colored in red If all the input data are correct Radina Tau will save the parameters and will reboot with the new configuration Inova bg Ltd 2011 Page 12 or 15 Radina Tau Username and password configuration Inova bg Ltd User Manual v1 2 Radina Tau Radio amp Ethernet Security Home Login Configuration This page allows to configure Login Username and Password Login Config Default Username root Password admin Reboot Enter the new Login settings below maximum 11 symbols Login Settings User Name root Copyright 2011 Inowa bg Ltd In Login
8. na Tau will load the last saved static address Use the following IP address IP address and network parameters are set to static IP Address IP address Gateway Gateway address Subnet Mask Subnet mask of the IP network Inova bg Ltd 2011 Page 9 or 15 Radina Tau User Manual v1 2 4 4 Settings for the IP transmitter IP Address 192 168 1 231 Port 2549 2 di Use Periodic Test on Server 1 Test Period 5 Min If Radina Tau works in mode Use Radio Transmitter amp Network or Use Network Only the IP network server parameters will be visualized The first group is corresponding to the first monitoring server You must set the IP address and the communication UDP port You can activate the periodic test Use Periodic Test on Server 1 and set the period If you want to use the second server you must enable it Enable Server 2 and to set the parameters in the same way as for Serverl Inova bg Ltd 2011 Page 10 or 15 Radina Tau User Manual v1 2 4 5 Settings for the digital inputs Digital Input 1 Settings Active State da da Type 7 Partition Transmit on backu Repeat Alarm Trar Type Partition Active State N C Transmit on backup Repeat Alarm Transmit Until Restore TUR 140 General Alarm si 99 Not Used N O N C Hardware AC Mot Used re TUR 401 Open Close by User 110 Fire Alarm 120 Panic Alarm 130 B
9. nt than 230 Subnet Mask 255 255 255 0 Inova bg Ltd 2011 Page 15 or 15
10. r If you choose Use Network Only radio settings will be deactivated Inova bg Ltd 2011 Page 7 or 15 Radina Tau User Manual v1 2 4 2 Settings for the radio transmitter Radio Settings Main Frequency 450 0000 Backup Count 4 v Backup 1 440 0000 Backup 2 430 0000 Backup 3 420 0000 Ea 410 0000 System 00 pa Parity Odd Use Smart Test Repeat Count 6 Repeat Test Count 1 Repeats in message 2 Test Period h E TUR Period min B Main Frequency Main frequency for radio transmitting Can be from 400 to 470 MHz with maximum of four symbols after the decimal point Backup Count Number of used backups Backup 1 2 3 4 Backup frequencies for the radio transmitting Can be from 400 to 470 MHz with maximum of four symbols after the decimal point For each digital input you can choose whether to transmit or not on the backup frequencies System System number Parity Parity check Odd or Even Use Smart Test When activated test messages will be sent over a period of time set by the field Test Period and this time will be restarted after every transmitted message regardless if it S a test message or not This option will reduce the number of test messages transmited through the radio channel Use this option only if your monitoring software supports it Repeat Count Determines how many times the data message will be transmitted through the radio channel Must be fro
11. stablished connection with IP server s when using 1 server ON when connection is established When using 2 servers ON when connection is established with both servers blinks if connection is established with only one server OFF when connection isn t established with both servers e Six digital inputs working simultaneously with RF and IP transmitters e Capability every digital input separately to be set to transmit on backup RF frequency e Capability every digital input separately to be set to re transmit RF message over a period of time until it is in alarm state e Configurable working mode for every digital input Normal Open Normal Close Check for AC voltage from 5V to 20V Deactivated e Configurable parameters sent for events on each digital input to IP servers Pout W f F yaz RF Output povver on different series 6 5 4 Tau 1 s Tau 2 5 3 e Tau 3 T sir Tau 4 2 390 400 410 420 430 2421 450 450 470 460 F MHz Inova bg Ltd 2011 Page 4 or 15 Radina Tau User Manual v1 2 2 Start working with Radina Tau The default IP address is 192 168 1 230 Make sure that your computer is in the same IP subnet see Chapter 9 Windows Network configuration To access the web server for configuration use Internet Explorer Chrome Firefox Opera or any other web browser and enter the Radina Tau s address http 192 168 1 230 or the new one if you already change it Alterna
12. tively you could write http radinatau If the device is accessible from that computer a connection will be established and you will be prompt to enter username and password Authentication Required 25 The server 192 168 1 230 80 at Protected requires a username and password User Name root Password ud Cancel The default settings which will be recovered after hardware reset are IP Address 192 168 1 230 Username root Password admin If you enter the right credentials you will have access to the web page for configuration Inova bg Ltd 2011 Page 5 or 15 Radina Tau 3 Homepage Inova bg Ltd Home Device Config Login Config Reboot Account number Device MAC Mode Firmware version DC Voltage User Manual v1 2 Radina Tau Radio amp Ethernet Security Welcome to Radina Tau home page Device Information Radina Tau 00 7771 D0 04 A3 4E 00 00 Radio Transmitter amp Metwork 1 1 Power Supply 13 6V Digital Input Current Status Digital Input 1 Digital Input 2 Digital Input 3 Digital Input 4 Digital Input 5 Digital Input 6 Mot Used Not Used Not Used Mot Used Copyright 2011 Inova bg Ltd On the homepage you can find main information about the device current status of the input voltage and the current state of each digital input Through the menu you could select one of the following actions Home Homepage Device Config Configur
13. urglary Alarm 133 24 Hour Alarm 137 Tamper 140 General Alarm gs 301 AC Loss 302 Low System Battery 308 Battery Test Failure 400 Open Close 401 Open Close by User Digital Input 4 Settings Active State Not Used M According to which working mode is selected in digital inputs settings different fields will become active deactive Digital inputs can be connected to PGM outputs of security panles or to any different kind of sensors panic buttons tampers and etc In the Active State field you can set the working mode of each input normal close N O or normal open N C contact check for AC on this input Hardware AC or you can disable the input Not Used When digital input is Inova bg Ltd 2011 Page 11 or 15 Radina Tau User Manual v1 2 connected to PGM or dry contact for 0 state is accepted value of the resistance to ground less than 300Q and for active 1 value more than 1 4KQ or open circuit the hysteresis is between 300Q and 1 4KQ If digital inputs are controlled by voltage for 0 state 15 accepted value of the voltage to ground less than 0 7V and for active 1 value more than 2 6V the hysteresis 1s between 0 7V and 2 6V Radio messages are transmitted through radio channel for each input Al to A6 for alarms on this input and B1 to B6 for restore In the radio settings for each input you can set the following parameters Trans
Download Pdf Manuals
Related Search
Related Contents
MANUAL DE INSTRUÇÕES FSY99701REL Anleitung COMPACT - Serie SBC Janvier – Février – Mars 2015 - La Cité des métiers du Val-de ABPM 7100 HMS 5.0 User Manual R600 - Golden State Cellular SM061A/B spanish 4 - Car OBD2 Tools global supplier Sinewave inverter - Sinus Wechselrichter - 第96回 衆議院 運輸委員会 昭和57年4月9日 第12号|国会会議録検索 Copyright © All rights reserved.