Home

6 - SL Group Kft

image

Contents

1. In case of wrong faulty expansion tank the system pressure may exceeds the safe value at high temperature which leads to the activation of safety valve If this occurs in the cold boiler the pressure may falls below the minimum level thus an electronic failure indicated on the display In case of faulty expansion tank it has to be changed ELECTRICAL WIRES AND CONNECTIONS CONTROL Have to be checked the status of internal electrical wires and their proper distance from any of hot spare parts Have to be checked the electrical connections at sensors pump and the engine for three ways valve HEAT EXCHANGER CONTROL In a well adjusted appliance the heat exchanger does not need any special maintenance Have to be checked the fume ways and if there are soot or subsidence it is neccessary to clean the whole heat exchanger The subsidences make more difficult for the fume to going out through the chimney furthermore worsen the heat unload ability thus the efficiency of the heat exchanger reduces In case of smaller contamination it is enough to remove the burner and clean the fume ways of the heat exchanger through the burner slot In this case make sure that the water can leak by the condensing syphon to the right place In case of huge contamination of the heat exchanger it could be taken out from the appliance It is necessary to remove the condensing plate before the extensive cleaning of the whole heat exchanger Have to be checked
2. boier USER S MANUAL DIGITAL DISPLAY OVERVIEW A Domestic hot water operating mode B Burner output indicator C Service reguest call your service partner D Pressure indicator E Solar operation mode F Temperature indicator G Heating operation mode H Reset press the Reset button Number Code display The digital display has a blue backlight The backlight turns on by pressing a button and turns off automatically after 15 seconds if you do not press any of the button OPERATING MODES HANDLING Status OFF Ignoring heat requests except for domestic hot water and frost protection of heating To activate the mode press the E marked button Status STAND BY In OFF status press the E marked button to change to Stand by and chose from the following modes Winter Domestic hot water and heating operation are allowed Summer Only the domestic hot water is allowed SLG Falcon wall hang condensing gas boiler USER S MANUAL Room thermostat or OpenTherm controller unit are suitable to indicate the heating reguest for the boiler controller The sensors closing in room thermostat indicates the heat reguest for the controller pesa In winter operation mode the display shows a possible status of a valid heat request If a higher priority request is received the process is discontinued and the controller changes to serve the higher priority request
3. DCS EE ee STAN KS ce Paste ned ease ions A ee ea en es 8 2 4 Avoid the damages eoused bY le r ance ices EE OR KE Ee oe od aa GE Re Oe N Re GR GES EG oe 8 BONER handline MEE ee GE ee Se Re 9 3 1 slee is sel ke EE OR N OE OE EE N ER 9 SLEG Falcon 24 36 Heatine DONG se EE N N eds EG Ge N N ee DE GE ge 9 SLG Falcon 24K 36K heating DAW boileri iss sees ies ses Ee se se ER GESE GR EE Ge ge EE oe es eb GE se ESE EES RSG Ge eg Ee 9 SIE FaleonAd Heating bolle SE a ES DE N eon GE RE RR EG EG EG 10 3 2 SLEDS DETOLE SWITCHING ON ENG boilef EEDEN EG OG EER BE GE EE Sos GEREG EE OE kakit 10 GUT of valve sEOR LOL ES a AE GN ee eN EE GN GE ee DE GO EE DE Se OER EG 10 Water pressure control of the heating SVSLEM sv Ge OE GEE GOS SEER GE Ge GREG EG Ge GN Gee Dee 10 3 3 Control panel ISAC Ee RE De aaa aero 11 Operating buttons OVerVi W iese ee ee RE K t AR AE Ee ee Ee ee EE Ee ee Ee VELE ee Ee ee Ee ee RE ee 11 Digital display OVERVIEW tees ee Des ee ee Do Eg Wee Ge ee ee GE Ge ee Ge EG GE Ge ee ee N EE 12 Operating modes handling N eo ee Ge be GE G 12 Adjusting the temperature of the heating water ses sees see ee ee ee ee ee ee EE Pe ee 13 Gas D rnerautormatic TUL BIng M es Ee Ge De ee GE n N 13 Hormat DUON n EE Ee ee EG ee EG Ee RD ee RE Ge ee Ee Ge t ne 13 Ee oge Wees EE EE AE EE AO 14 Faildreceedesand thbeir meanings EE RA ee a GR Ee Ee DE 15 4 1 Fallar codes teduited users interventio sd ge ee De ee Ee N de 15 EO MACK Ol danie te N G
4. Display in summer mode without heating request SLGF 333C ADJUSTING THE TEMPERATURE OF THE HEATING WATER Use the B marked buttons to increase or decrease the temperature of heating water For pressing buttons the display shows a flashing temperature indicator to help the adjustment of the needed temperature with 1 C accuracy SLGF 3330 After 5 seconds if you do not press any of the B buttons the display reverts to the starter status Use the A marked buttons to increase or decrease the temperature of domestic hot water For pressing buttons the display shows a flashing temperature indicator to help the adjustment of the needed temperature with 1 C accuracy SLGF 333 After 5 seconds if you do not press any of the A buttons the display reverts to the starter status GAS BURNER AUTOMATIC TURNING ON When the controller receives a real heating request the ignition of gas burner is started In case of ignition failure the controller attempts the re ignition in specified numbers If all the ignitions are failed the display shows EU failure code INFORMATION BUTTON For pressing C information button the display shows the following data For single pressing of Information button the display shows the temperature measured by solar sensor aii For double pressing of Information button the display shows the temperature measured by outside temperature sensor A pos
5. E GE GR Ge en eg ie 15 EO Taulty Hame IMGICALOM si ER Ge ee GE OE Ge Ee De cn 15 6 EOS OVEREATING proteeti OR n Se RE ERGE AG BEG EG GM GE EER ES GE Ee Ek GES EE Ee WEG GEE 15 BARE EIE octets EE EE RE ER noses ehaa andes NN 15 EOS Flame lrecle TANUL S Ses ER BERGE EE ER EO GE KEN DR AE GE ei OE ER GEE EA OE Ee Ge ee Ge Oe IG EE BEG EG Dee 15 EO9 Gasvalve alte te se a GR EG ee Ge ee Se Ge Ge De be Ee ee ee ON GE ED 15 ET SRO tial Fale se NG ED EE GR OD EG Ge OE ON ge Re KG ee de ES AEA 15 E15 Heating Flow sensor failure sees ses ese ee EE ed EE ee GEE ed EE de RE dd EG de AGE ee GEE ee GEE ee 16 E16 Failed test of the heating flow temperature SeNSOF sees sesse RE RR Ee ee AR ee ee RR ee ee ee RE ee ee 16 E17 Failed test of the heating return temperature Sensor iese see see RR Ee ee Re ee RR Ee ee ee RE ee ee 16 Els Failed test or faultysanser control SG ei ie Ge AS ee EE ee n AG waves 16 EZ T COMODO SN aile ss ee PG Go ee EG GE ee Ge eg 16 E33 Heating return temperature sensor failure siese se ee ee ee EG Go Ge ee GE GR ER de 16 E35 Heating Flow temperature Sensor failure ae ee es ee ee en Ee ee 16 4 2 Failur codes resulting baeiler blok iss GE ER ER GEE GE SE SEE GE SEEK Ge Ka ew Ge ee ek See 16 F07 IC Haiesastempertuie se SE AG N EE N EE ee ne Ee Ge areas 16 FI Uuiplds die bolle ES AD EI N 17 BA LOW power SUNDI V Ek EG Ee Ge N ee De Ee N 17 PSS LOW water Dressuie se ES EG ee Ge N EE De e
6. SZIL Falcon CONDENSING GAS BOILER User s Manual N I 3212 Gy ngy shal sz Toldi Mikl s utca 3 E mail sig ft slg ba Type of the boilers SLG Falcon 24 36 44 Wall hung condensing gas appliance for hot water central heating SLG Falcon 24K Wall hung condensing gas appliance for hot water central SLG Falcon 36K heating and for the production of domestic hot water 1 3 4 CONTENTS Explanation of symbols in user manual and Safty information ccccccccssssecceceeseeceecaeseeceesaeeseceesaeeeeeesenes 6 Led Explanation OF SVIMOOIS ezzel veut nase sau ns Ge ee Ge ne ee 6 WV GI NN EE EE AE EE AA E SE AE 6 Mapori antin ormat Ons SE ee DE ed 6 NUS CEU GUN Os as ee ee ee ee T Ee ee Ee ae 6 1 2 Importantsafets Iniofmatiops ss EN ED EE 7 iastructiop in case of gas odeUr EE ete a a a GE nd 7 Instruction in case of smelling flue gas leaking from the boileF ees see ee ER AR Ee ee RE ee ee ee 7 Datagestansed by laultv handle se Ee EE 7 Dangersconserning gas exDIEsiOf EE ee ee ESE Ge ee Ve Ge be Ee Ge E De Ge 7 The boiler installation how to move it to an other place The boiler and its environment 7 Proper use of tie boiler and certificati ie EG SE Si ge Ge De ER eg Ge Ge EG Ge ee Ee Ge Rg ee ie 8 2 Proper use of the borler Se SE De a DE oe RE Ge GE beat De ee DE or ie 8 2 2 CEC eGClaration Or COMIOMIMIGY ee De ee Ge ve lduadsbeumeaonaelacacstatoaseiete 8 2 3 Bollef Ey
7. The flame is not detected and all the retries are failed In this failure status the boiler does not operate to restore the normal operation press the reset button E02 FAULTY FLAME INDICATION The controller detects flame but there is no real heat request from the room thermostat or DHW side In this failure status the boiler does not operate to restore the normal operation press the reset button E03 OVERHEATING PROTECTION The heating flow or return sensor measures too high temperature In this failure status the boiler does not operate to restore the normal operation press the reset button E05 FAN FAILURE The controller does not receive valid signal from the fan In this failure status the boiler does not operate to restore the normal operation press the reset button E08 FLAME CIRCLE FAILURE The detected flame level is outside of the specified range which indicates a failure in either of electronic components EO9 GAS VALVE FAILURE The controller receives invalid signal from the gas valve E12 INTERNAL FAILURE Intenal failure is occured SLG Falcon Wall hang condensing gas boier USER S MANUAL E15 HEATING FLOW SENSOR FAILURE Press reset button E16 FAILED TEST OF THE HEATING FLOW TEMPERATURE SENSOR Failed test of the heating flow temperature sensor Press reset button E17 FAILED TEST OF THE HEATING RETURN TEMPERATURE SENSOR Failed test of the
8. at Information for the maximum limited operating conditions contained in the book of Installation and maintenance instructions issued for the attention of service experts 2 2 CE DECLARATION OF CONFORMITY This product is in its structure and operation corresponding to the relevant European directives which is certified CE certification The boiler was tested by the following standards and specifications LVD 2006 EC EMC 2004 108 EC PED 97 23 EC GAD 2009 142 EC 2 3 BOILER TYPES SLG Falcon 24 36 44 Wall hang condensing gas boiler for hot water central heating SLG Falcon 24K Wall hang condensing gas boiler for hot water central heating SLG Falcon 36K and domestic hot water producing with plate heat exchanger 2 4 AVOID THE DAMAGES COUSED BY FREEZ If the boiler will not operate for longer time the heating system and the boiler must drain to avoid the damages coused by the freezing To draing the boiler and the heating system switch the boiler off and use the draing valve to empty the boiler After the drain procedure close the drain tap and the gas tap Drain the heating system also 8 SLG Falcon wall hang condensing gas boiler USER S MANUAL 3 BOILER HANDLING USAGE 3 1 BOILER CONNECTIONS SLG FALCON 24 36 HEATING BOILER SLGF 311A A Heating flow connection 1 B Gas connection 3 4 C Cold water supply connection D Heating return connection 1 E Conden
9. e 17 F39 utside sensor TANNINS vs ke Bee ei De ee Ge ee ee Se Taa 17 FA0 High water pressure ie Ese SE ee RD Ge de A Ee ee OO Be ee ee ieee 17 F41 Tbetillingvalve operates ies De SG GE ee Re ed ed a a TE EG Do ee ee Ge i 17 FA 2 Eailed NE so ta ER ee ee RE Oe DE ee bas ea ee Ge DE ee oo he ee DE eg l 17 F43 Low water pressure anter automatic TIMMS iss iese ss ee Ed ee Ge Ee se De bee ee be eed 17 F47 Water pressure sensor is not contacted iss see ee RE E Ee ee Ee egek ee ee ee ee ee ee ee ee 18 F50 Domestic hot water solar sensor failure esse ee see ee ee z ee ee ee ee ee ee ee ee RE ee 18 EE 1 Solar Panel SAMSON Fal OY ses EG ED ee ED ee Ee 18 F52 Domestic hot watersensar TAULE sus ss ER es ees Eie ie AR Ge BE NG Ee N ee EEN EG OR Ee GR Ee es GE 18 SZ Fluegas temperature sensor alte me a NG Oe Ge ee N Ee De 18 Falls WMaiting TOR sensor testinE sies oe ee E Og ee er a 18 VISIR GINA Ee ES EE ES Oe ED DS GE EG GR Ge a Ee Ee De Ee GE eetiteaaeaeance 19 5 1 Periodi friaintenante INSPECTION ss cease BEE OE EE SG ER GE SE Ee VER EG SE S S S Sk SE EES Ee 19 5 2 Tasks during maintenance and ISPECTION iese ee ER AR ee EA Ee ee ee ee ee ee ee ee ee ee ee ee 19 Pressure control ofthe expan iON EO ss EED DO RE GE EG Ge REG GE Eg RE GEE Ge Ge GE Ee SEG ER s s 19 Electrical Wires and CONNECTIONS control ees see se Ee de de de ee ee 19 HeatexchansErcontol EE ED ee Ge N E Pe Ge de ee ee ee Ge GE Ee
10. e voltage returns to the specified value above 170V AC F37 LOW WATER PRESSURE Check the pressure of the heating system Only the cold boiler allowed to be refilled with heating water The refilling into hot boiler results the failure of the appliance cracking of the internal components These kind of demages are not covered by responsibility of the manufacturer and not considered under warranty To refill the boiler use the G filling valve situated on the bottom of the appliance The boiler maximum operating pressure is 3 bar Be careful that this value is not allowed to exceed during filling F39 OUTSIDE SENSOR FAILURE If the value measured by the sensor returns into the normal range the failure is cancelled The operation range for the sensor is between 40 C and 50 C To cancel the failure the measured value has to be in the normal range F40 HIGH WATER PRESSURE Check the water pressure of the heating system If this problem occured more times please contact with the service expert of SL Group F41 THE FILLING VALVE OPERATES The boiler is under filling by the electronic filling valve F42 FAILED FILLING After the filling the system pressure does not reach the specified value Please contact with the service expert of SL Group F43 LOW WATER PRESSURE AFTER AUTOMATIC FILLING After the automatic attempt for filling the water pressure remains low SLG Falcon Wall hang condensing gas b
11. ee Nee GE 19 BUGMINS System CONTO EE ES EG DE k s EG GE EG DE Ge Ee EE 20 CONGENSING SYphon cleanlAE RE N Ge GE Ee Mays N GE GE Ge GE Ge N 20 5 3 Proof of malritenapte Compie On ER se ee EE ee ee EG Ee ee EE Ge Ge be 21 Switching of the boilerier longer period iS De ie DE s n AG Ge kek GE ee Ee ve se GE 22 7 8 9 First ignition of your boiler Your service CONTACT sesse sesse se see ee see ee ee RR Ee ee ee ee Ee ee ee Re ee ee ee ee ee ee RE ee ee Notes and reminders The protocol of the fi ESE ed dele Gee OE Ed RO gt ztt t USER S MANUAL 1 EXPLANATION OF SYMBOLS IN USER MANUAL AND SAFTY INFORMATION 1 1 EXPLANATION OF SYMBOLS WARNINGS A The warnings in the text are marked with warning triangle and framed The reguired actions and conseguences of those failure are included in the framed text IMPORTANT INFORMATION Important information concerning people and surrounding objects not dangerous warnings INSTRUCTION p e Instructions how to operate the boiler SLG Falcon wall hang condensing gas boiler USER S MANUAL 1 2 IMPORTANT SAFETY INFORMATIONS INSTRUCTION IN CASE OF GAS ODOUR a Turn off the gas tap Extinguish any open flames Open doors and windows Fresh the air in the room Do not use electrical appliances which could be given off sparkle Notify the gas supplier or if the error occured in the gas boiler please contact with the service expert of SL Grou
12. heating return temperature sensor Press reset button E18 FAILED TEST OF FAULTY SENSOR CONTROL Press reset button E21 CONTROL BOARD FAILURE The ADC test ended with failure There is an electrical problem E33 HEATING RETURN TEMPERATURE SENSOR FAILURE The signal was given by the heating return temperture sensor is outside of the specified range In this status the heat requests are ignored If the temperature returns into the specified range the failure can be cancelled with reset button E35 HEATING FLOW TEMPERATURE SENSOR FAILURE The signal was given by the heating flow temperture sensor is outside of the specified range In this status the heat requests are ignored If the temperature returns into the specified range the failure can be cancelled with reset button 4 2 FAILURE CODES RESULTING BOILER BLOCK F07 HIGH FLUEGAS TEMPERTURE If the measured temperature drops below the adjusted value within 15 minutes the appliance restarts The failure can be cancelled with unplugging in that case if the temperature returns into SLG Falcon wall hang condensing gas boiler USER S MANUAL ke the specified range F13 UNPLUG THE BOILER Any attempt to cancel this error by pressing reset is unnecessary This failure can be cancelled by unplugging the boiler F34 LOW POWER SUPPLY If the boiler operates the burner turns off The failure is ended if th
13. heating system and the boiler must drain to avoid the damages coused by the freezing The stept of the swittching off for longer period Close the gas tap Drain the water from the heating system and from the boiler Close the tap of the cold water supply and the other taps also Switch the boiler off and unplug from the mains SLG Falcon wall hang condensing gas boiler USER S MANUAL v1 0 7 FIRST IGNITION OF YOUR BOILER YOUR SERVICE CONTACT Because of the needed maintenance inspections and repairs to be done professionally please hereby note the contact details of the service expert of SL Group who installed your boiler Furthermore please note the data of your appliance too me N me a N one N Phone Nr 2 Boiler type Installation date SLG Falcon Wall hang condensing gas boier USER S MANUAL 8 NOTES AND REMINDERS SLG Falcon wall hang condensing gas boiler USER S MANUAL 9 THE PROTOCOL OF THE FIRST IGNITION Owner Operator Name Post code town Phone email Street nr Boiler data Boiler type Serial number Date of first ignition Installation place _ Basement L Upstair Other e L Coaxial system L Aluminium Other L Twin pipes Plastic Fumi outlet Full length 5 meters Elbow 90 _____ pcs Elbow 15 45 _____ pcs Checking the fumi pipe system C yes C no o CO2 in the fume at maximal nominal power u 02 in the fu
14. me at maximal nominal power Gas setting and fumi data Used gas 7 Hnatura propan _ butan F t rt k kWh m3 u mbar o kW w mbar Gas pressure u kW Gas flow pressure Adjusted maximal nominal power Adjusted minimal nominal power Gas flow volume at maximal nominal power Fumi lost at maximal nominal min power ay CO at maximal nominal power Fumi temperature at maximal nominal power Gas flow volume at minimal nominal power Fumi lost at minimal power __31 CO at minimal nominal power u ppm u l min Fumi temperature at minimal nominal power j o Measured maximal heating flow temperature Measeured minimal heating return temperature i i 6 Hydraulic system Additional expansion tank Hydraulic changer type dimension pressure C Circulation pump C Additional tanks parameter Modified software parameters Function Original value New value Function ____ Original value New value Function Original value New value Function _____ Original value New value Function o Original value New value Function __ Ss Original value New value Function ___ Original value New value Function ____ Original value New value SLG Falcon Wall hang condensing gas boier USER S MANUAL Other tasks done during the first ignition Electric connection checked lyes C no Remark mm C Condensing trap filled up Air Fumi measure done C Full working test d
15. oier USER S MANUAL F47 WATER PRESSURE SENSOR IS NOT CONTACTED The water pressure sensor does not find the contact with the boiler Please contact with the service expert of SL Group F50 DOMESTIC HOT WATER SOLAR SENSOR FAILURE To cancel the failure the measured value has to be in the normal range F51 SOLAR PANEL SENSOR FAILURE To cancel the failure the measured value has to be in the normal range F52 DOMESTIC HOT WATER SENSOR FAILURE To cancel the failure the measured value has to be in the normal range F53 FLUEGAS TEMPERATURE SENSOR FAILURE To cancel the failure the measured value has to be in the normal range F81 WAITING FOR SENSOR TESTING SLG Falcon wall hang condensing gas boiler USER S MANUAL 5 MAINTENANCE 5 1 PERIODIC MAINTENANCE INSPECTION The periodic maintenance and inspection of your appliance is very important in order to have the boiler in safety and reliable status The maintenance has to be done by official service expert of SL Group 5 2 TASKS DURING MAINTENANCE AND ISPECTION Hereby you find the tasks have to be done during maintenance and inspection These processes are very important for safety operation PRESSURE CONTROL OF THE EXPANSION TANK Have to be checked that the expansion tank pressure corresponding to the specified value This pressure value is between 0 8 1 bar If the pressure is below the specified value the air have to be refilled
16. one L Tighten check at gas and water side Other remarks The above mentioned detailed heating system tests done The owner operator knows the useage of the boiler knows the safety requirement and the operation of the boiler The owner operator has been remindend the importance of the Date F usual maintenance The first installation and tests done by Owner Operator sign Send a copy of the Protocol to the SL Group Fit stechnika Kft SLG Falcon wall hang condensing gas boiler Sz E GR UP F T ST ENG K KET 3212 Gy ngy shal sz Toldi 1 MI i l s u utca 3 E mail sigkft slgkft hu www sigkf kft
17. p INSTRUCTION IN CASE OF SMELLING FLUE GAS LEAKING FROM THE BOILER Switch the boiler OFF Open doors and windows Fresh the air in the room Contact with the service expert of SL Group DAMAGES CAUSED BY FAULTY HANDLING Failures caused by improper handling may result personal injury and material demages The manufacturer does not take responsibility for demages due to improper handling Make sure your children do not handle the boiler Make sure only that person handles the boiler who can do it properly DANGERS CONSERNING GAS EXPLOSION The maintain and work in your gas system is allowed only for the official SL Group s expert who has the special license THE BOILER INSTALLATION HOW TO MOVE IT TO AN OTHER PLACE THE BOILER AND ITS ENVIRONMENT The boiler can be installed by official SL Group service expert only Do not change the fume pipes Do not obstruct the proper functioning of the safety equipments Do not store or use flammable materials paper thinner paint near the boiler SLG Falcon Wall hang condensing gas boier USER S MANUAL 2 PROPER USE OF THE BOILER AND CERTIFICATION 2 1 PROPER USE OF THE BOILER The boiler can be installed only in a closed heating system The manufacturer does not take responsibility for any failure due to use the boiler in open heating system The boiler can be operated for domestic use only The boiler must not be used for producing industrial he
18. re that the E condensing drain connection leading the water to a safe area f exp sewage If the system water pressure is low the refill is necessary Only the cold boiler allowed to be refilled with heating water The refilling into hot boiler results the failure of the appliance cracking of the internal components These kind of damages are not covered by responsibility of the manufacturer and not SLG Falcon wall hang condensing gas boiler USER S MANUAL considered under warranty To refill the boiler use the G filling valve situated on the bottom of the appliance The boiler maximum operating pressure is 3 bar Be careful that this value is not allowed to exceed during filling Make sure that the water pressure does not exceed the specified 1 1 2 bar during filling the cold appliance If the pressure exceeds 3 bar in the boiler or in the heating system the built in safety valve starts to operate and in order to reach the safety water pressure unload the unnecessary water through the E condensing water drain connector When the filling is finished close the filling valve 3 3 CONTROL PANEL USAGE OPERATING BUTTONS OVERVIEW SLGF 331A A Domestic hot water temperature adjusting B Heating water temperature adjusting C Information D Reset E On Off and operating mode changing button F Digital display SLG Falcon Wall hang condensing gas
19. sible status of the display SLG Falcon Wall hang condensing gas boier USER S MANUAL The display status after pressing the Information button CONTROL MODE Enter directly to the Control mode by pressing Information button for 10 seconds After selecting the Control mode the following sign appears on the display DO In this mode you can get information about DHW temperature adjusting by pressing A button and about heating water temperature adjusting by pressing B button You can get information about the following parameters 0G Heating flow sensor temperature 00 125 C WA Heating return sensor temperature 00 125 C ig DHW sensor temperature 00 125 C Wd DHW sensor temperature down tank 00 125 C Q4 Solar collector sensor temperature 00 125 C 85 Flue gas sensor temperature 00 125 C Db Outside sensor temperature double digit 1 Current speed of the fan rom x 10 068 Current system pressure 09 Current flame intensity uA x 10 between 00 99 19 Control panel software version SLG Falcon wall hang condensing gas boiler USER S MANUAL 4 FAILURE CODES AND THEIR MEANINGS 4 1 FAILURE CODES REQUIRED USER S INTERVENTION On the display the failure codes required user s intervention are started with E To unlock the failure codes press the reset button or contact with service expert of SL Group E01 LACK OF FLAME Lack of flame failure
20. sing water drain connection 32 G Filling valve SLG FALCON 24K 36K HEATING DHW BOILER SLGF 312A A Heating flow connection 1 B Gas connection 3 4 C Cold water supply connection 1 2 D Heating return connection 1 E Condensing water drain connection 32 F DHW connection 1 2 G Filling valve SLG Falcon Wall hang condensing gas boier USER S MANUAL SLG FALCON 44 HEATING BOILER SLGF 313A A Heating flow connection 1 B Gas connection 3 4 D Heating return connection 1 E Condensing water drain connection 32 3 2 STEPS BEFORE SWITCHING ON THE BOILER CUT OFF VALVES CONTROL Check the cut off valves at the boiler connections Make sure that they are open In open status the arms of the ball valves point to the flow direction WATER PRESSURE CONTROL OF THE HEATING SYSTEM Check the heating system pressure which is 1 1 2 bar in cold status depending on the size of the system Make sure that the pressure should not be higher than this value since the boiler is in operation and when the water temperature increases its pressure also increases If the pressure exceeds 3 bar in the boiler or in the heating system the built in safety valve starts to operate and in order to reach the safety water pressure unload the water through the E condensing water drain connector to reach the optimal pressure Make su
21. the heat exchanger on water side SLG Falcon Wall hang condensing gas boier USER S MANUAL The accumulated contaminations and scale in the heat exchanger reduce the cross section of flow and results lower cooling for the heat exchanger It leads to cracking of the heat exchanger The failures due to the contaminations of the heat exchanger are not considered under warranty BURNING SYSTEM CONTROL In a well adjusted appliance the burner system does not need any special maintenance Check the clearness of the fan CONDENSING SYPHON CLEANING At the end of the maintenance after the cleaning of the heat exchanger the condensing syphon also has to be cleaned properly in order to be free way for leaking of condensing water produced during operation SLG Falcon wall hang condensing gas boiler USER S MANUAL 5 3 PROOF OF MAINTENANCE COMPLETION To verify the periodic maintenance and inspection lets fill in the below table by the service expert who services your appliance Gas boiler type SLG Falcon Serial Nr Checking the pressure of the Checking the electric wires Checking the primary heat Checking the burner unit Cleaning out the condensing Date of completion of work and its connections Checking the possible Verification of work leakages SLG Falcon Wall hang condensing gas boier USER S MANUAL 6 SWITCHING OFF THE BOILER FOR LONGER PERIOD If the boiler will not operate for longer time the