1. entering parameters will promote the Programming mode after a short time out 10 Synel Industries Ltd PRintX401 V Operation All definitions of Management modes are listed in the table below Function Description Code Value Default Remarks amp Glossary Number Management of System Tools Initialisation of 06 9210 Memory Operation Mode 12 0006 0000 Card and FP Operation Mode 12 0008 0000 Code and FP or FP only Management of Access Cards Authorized Personnel Insert card s to 20 9999 x PRX 40 list and Fingerprint Delete cards from list 21 8888 ui for PRX 40 and fingerprint Management of System Tasks Open Door Time 10 0000 1 0 To 25 5 Seconds 0225 Open Door 00 0000 Opens the relay for Door Open Time Set New Master Code 13 Xxxxx 123456 Must consist of 8 digits XXXX 78 Synel Industries Ltd 11 Operation PRintX40I V Operation mode card and FP Bring Card within PRintX 40I_V range Place your finger on the PrintX unit you have 10 sec to acknowledge Press To insert 1 To exit 2 Operation mode code and FP Key in a 4 digit code Place your finger on the PrintX unit you have 10 sec to acknowledge Press To insert 1 To exit 2 Operation mode card and FP Bring Card within PRintX 40I_V range You have 10 Sec to acknowledge Press To delete 1 To exit 2 Operation mode code and FP Key
2. exception of isopropyl alcohol e Subject the fingerprint sensor to heavy shocks or vibrations e Allow the sensor to come in contact with metallic objects Synel Industries Ltd 17 Main Branch Synel Industries Ltd Yokneam Industrial Park 2 Hamada St POB 142 Yokneam 20692 Israel Tel 972 4 959 6777 Fax 972 4 959 0729 E mail info Osynel com Site www synel ind com Tel Aviv Branch Synel Systems Ltd Tel 972 9 775 0400 UK Branch Synel Industries UK Ltd Tel 44 181 900 9991 North America Branch Synel Systems N A Tel 1 905 678 2605
3. in a 4 digit code You have 10 sec to acknowledge Press To delete 1 To exit 2 3 2 1 Management of System Tools Set New Master Code The Master Code can be changed using the Instruction Code 13 After entering Programming Mode key in 13 followed by an eight digit number that will serve as a New Master Code It is recommended to change the Master Code default immediately after installing the unit Memory Initialisation Warning All data saved on PRintX 401 V will be deleted This options deletes all cards in the memory Initialisation of Memory takes a few seconds to complete the green LED blinks wait until you hear the buzz signifying completion 12 Synel Industries Ltd PRintX401 V Operation Operation Mode Card and Finger Print verification only Control is performed by Card and card holder fingerprint accepted by the PRintX unit 1 Press 3 times function keys 1 amp 2 simultaneously The red LED flashes 2 Key in the eight digit Master Card code default 1234 8 3 Key in Instruction code 12 and 0006 Code and FP only in PRintX401 V FP Control is performed by code and fingerprint accepted by the PRintX unit If the fingerprint unit is in auto detection mode identification the user does not need to Key in the code just place his finger on the sensor 1 Press 3 times function keys 1 amp 2 simultaneously The red LED flashes 2 Key in the eight digit Master Ca
4. PRint X401 V User Manual Synel Industries Ltd PRintX40I V 30 8 04 Part no 650401 PRintX40 222 02 This document has been prepared for PRintX40I V device All rights reserved Reproduction or use without express permission of editorial or pictorial content in any manner is prohibited No patent liability is assumed with respect to the use of the information contained herein While every precaution has been taken in the preparation of this manual Synel Industries Ltd assumes no responsibility for errors or omissions Neither is any liability assumed for damages resulting from the use of the information contained herein DCM and SY are trademarks of Synel Industries Ltd All trade names referenced herein are either trademarks or registered trademarks of their respective companies Synel Industries Ltd PRintX40I V Table of contents Table of contents Tz IntrOd ctiOm 25 see est ot et toe iei s 1 1 1 Differences between PRintX40I amp PRintX40V 1 1 2 Technical Specilications eie tnos 1 1 3 Man machine Interface cccccccccecececeseceseseeeeeeess 2 1 4 Mechanical Features i 2 1 5 PaCk ae EE 2 2 Inst llatton sert erteilt Orosii tes ahve kd 3 2 1 Wares Conn ction a i ius b e i ires 5 Or Operaia t obtutu tasca irene 8 3 Access Control using PRintX40I V unit 8 3 2 Programming Mode is eit epe vaas 9 4 Maintenance iecit enti eee ted to qi
5. Step 3 Route PRintX 40I V wiring Step 4 Place two screws in position A one at the top position and one at the bottom position secure PRintX 401 V to the wall Step 5 Route PrintX wiring Step 6 Slide groove on the PRintX against PRintX 401 V slip Step 7 Place two screws in position A one at the top position and one at the bottom position secure PRintX to the wall Step 8 Proceed according to wires connection instructions page 5 Option B Step 1 Remove screw covers and screws from top and bottom of the unit front panel 1 Step 2 Remove back panel Step 3 Drill holes according to position B shown on the mounting tem plate for both units PRintX 401 V and PRintX Step 4 Fasten back panel on the wall 2 place two short screws in posi tion B Secure PRintX 40I V to the wall Step 5 Route the cable wires via centre hole C Step 6 Route PRintX 40I V PrintX wiring Step 7 Slide groove on the PRintX against PRintX 401 V slip Step 8 Fasten back panel on the wall 2 place two short screws in posi tion B Secure PRintX to the wall Step 9 Route the cable wires via centre hole C Step 10 Place and secure PRintX 40I V PRintX front cover 2 using two 4 Synel Industries Ltd PRintX40I V Installation short screws position A Step 11 Proceed according to wires connection instructions page 5 2 1 Wires Connection There are three connection types 2 1 PRintX 40I V Power supply door lo
6. V Operation Delete Code s from List Deleting cards can be performed following this procedure e Codes may be deleted one at a time or one directly following another When the green LED flashes the PRintX 40I V is ready to read codes the card s must be brought within the unit range e This operation is cancelled reverted to programming mode after a short time out if operation is not acknowledged within 10 sec Press function keys 1 amp 2 3 times simultaneously The red LED flashes Key in the eight digit Master code default 1234 8 You are in programming mode Key in code 21 key in the four digit Master code 8888 PRintX red LED flashes Key in user code You have 10 sec to acknowledge e To delete an additional code 1 e For exit mode press 2 Ne RM 3 2 53 Management of System Tasks Open Door Access can be given by using a Master Code After keying in Programming Mode key in 0 six times Open Door Time It is possible to adjust the window of accessability during which a door opens when accessed For example if only one person enters you may decide that 1 5 seconds is enough time for the user to open the door but if more than one is expected to enter you can choose to prolong door opening time Thus after entering Programming Mode key in the number 10 and then four digits For example if you key in 0015 the delay time will be 1 5 seconds 3 2 4 FPU operati
7. ce See Managing Access Cards or Codes on page 13 Verification is proofing of the currently scanned fingerprint against the stored fingerprint templates for that user PRintX operates as a server interacts to accept PRintX 40I V instructions A four mode led is designated for status indication A flashing orange led indicates that the employee is Flashing orange requested to place his finger for sampling purposes while Enrolment process is on Waiting for fingerprint validation while performing verifi Orange 8 cation Green Successful operation Red Failure A ledis activated to indicate current status when operation is completed the results are transmitted to PRintX 40I V Synel Industries Ltd 9 Operation PRintX40I V 3 2 Programming Mode The PRintX 40I V divides its tasks into three categories 1 Management of System Tools 2 Management of Access Cards authorized personnel 3 Management of System Tasks How to Enter programming mode AII system management requires entering the system 1 Press 3 times simultaneously on function keys 1 amp 2 each time will be followed by a short beep and an orange LED will be lit 2 Key in the eight digit Master Card code default 12345678 It is recommended that the client change this code later 3 After entering Programming Mode you can define parameters as follows Note This is a continueous procedure a delay while
8. ck amp bell connection The PRintX 40I V PRX40 unit 12 wiring connection used for the door relay bell and power supply control for color codes refer to the table below Wire No Wire Function Present Color Code 1 Vin Power VCC Red 2 Gnd Black 3 TxRx RS 485 Grey 4 TxRx RS 485 Purple 5 TxD RS 232 White 6 RxD RS 232 Green 7 Tamper Control Brown 8 Normal Neutral C Blue 9 Normal Close N C Yellow 10 Normal Open N O Orange 11 Bell 1 Black White 12 Bell 2 Red White 2 1 3 PRintX 40I V and PRintX P connection Wiring instructions 1 Insert the PRX40 s RJ 45 connection box at its hidden position on the wall Da Connect PRintX P unit s flat RJ 45 connector to connection box Synel Industries Ltd 5 Installation PRintX40I V PRintX RJ 45 Connection Box reference Wire function PRintX P2 PRintX P3 Wire No Connection box 5 Pin female 7 Pin female Colour Code GND 5 1 BL Wiegand data 1 2 2 OR Wiegand data 0 1 3 BK Led1 1 4 RD Led2 3 5 GR Not used 6 YL 3 Connect PRintX 40I V to RJ 45 connection box route 5 wires as follows PRX40 31 RJ 45 Connection Box PRX40 Cable Col Wire Connection box Wire Function our Code No Colour Code GND Black 2 OR Wiegand data 0 Green 4 RD Wiegand data 1 White 3 BK LED 1 Yello
9. e 16 Synel Industries Ltd i PRintX40I V Introduction 1 Introduction PRintX40I V is a biometric stand alone controller one of the series of Synel s access control protocols It is a unit that operates with either a fingerprint verification version PRintX40V catalogue number 00430 or a fingerprint identification version PRintX40I catalogue number 00431 further to user card reading by the proximity unit The proximity and biometric units are adjacently installed at sensitive locations for granting access to secure areas The PRintX40I V works with various unit settings according to the security level required at the location of the unit Defining parameters is simple while maximum security is enabled by using a password defined by the user Access is available for upto 4000 card holders in the verification version and upto 200 card holders in the identification version stored in an authorized list This list is created and edited using keyboard 1 1 Differences between PRintX40I amp PRintX40V e PRintX40D Identification does not require a card code Upto 200 finger print templates are stored in the terminal s memory Whenever an employee places his finger on the sensor the FP fingerprint unit polls all existing templates until there is a match and confirms rejects e PRintX40V Verification requires a card code The template is stored in reference to a card code Upto 4000 card codes and templates are stored Wh
10. en an employee swipes his card keys in his code the unit checks if the card code number exists if it does it checks also the template assigned to that number 1 2 Technical Specifications e Maximum Range 10 cm 4 inches e Operating Frequency 125 kHz e RS232 or RS 485 ASCII 9600 b s e Storage for 4000 200 templates e Sensor vendor Bioscript e False rejection rate 0 001 e False acceptance rate 0 001 Synel Industries Ltd 1 Introduction PRintX40I V 1 3 Man machine Interface Indicator for Power card confirmation rejection and keyboard entry fin gerprint a tri color led 10 digit keyboard Bell button RF coupling of proximity card Buzzer for audio confirmation of operations Mechanical Features Dimensions 137X115X28 mm Weight 360gr Operating temperature 0 to 60 C PRintX 401 V Power supply 12Vdc 20 5A PRintX Power supply 5Vdc 21A Output relay rating 24 V 3 A Tamper sensor output TTL level max 16 mA Package PRintX 40I V proximity reader PRintX P biometric reader verification identification PRintX P power supply adaptor 5 Volt 1 A stabilized wide range input 100 240 AC input RJ 11 Connection box with 5V power input RJ 45 Connection box Four 3 5x50mm Philips screws four 3 5x19mm Philips screws and four for position B four Brick Plaster anchors Mounting template User manual Recommended PRintX 40I V Power supply adaptor 12 to 15 Vdc max 880 mA Synel Industri
11. erformed following this procedure Press 3 times function keys 1 amp 2 simultaneously The red LED flashes Key in the eight digit master code You are in Programming mode Key in code 20 and 9999 PRintX orange LED flashes Key in the four digit user code PRintX orange LED is illuminated User finger should be noe placed on PRintX sensor green LED indicates success p You have 10 sec to acknowledge e To insert an additional card 1 e To exit this mode press 2 QN ON Note Inauto detection mode there is a limit of upto 200 fingerprint tem plate Delete Card s from List Deleting cards can be performed following this procedure e Cards may be deleted one at a time or one directly following another When the green LED flashes the PRintX 401 V is ready to read cards the card s must be brought within range of the unit e This operation is cancelled and reverted to programming mode after a short time out if the operation is not acknowledged within 10 sec 1 Press function keys 1 amp 2 3 times simultaneously The red LED flashes 2 Key in the eight digit Master code default 1234 8 You have entered programming mode 3 Key in code 21 key in the four digit Master Card code 8888 4 PRintX red LED flashes 5 Bring User card within range of PRintX 40I V 6 You have 10 sec to acknowledge e To delete an additional card press 1 e To exit press 2 14 Synel Industries Ltd PRintX401
12. es Ltd PRintX40I V Installation 2 Installation The PRintX40I V readers are installed in any type of facility The following guidelines are to be used when installing the units e Keep the cable assembly separated from and at least 30 cm away from any cable e Use a power adaptor dedicated to the proximity unit Make sure the adapter carries a safety recognition marking such as UL CSA or CE Note When using the identification feature the finger unit can be installed outside the door and the PRX40 reader installed in the inner side of the door designated for setup only While following step by step instructions for mounting refer to the diagram below and the mounting template CAT No 600090 MD600090 01 A Front panel Back panel x2 Synel Industries Ltd 3 Installation PRintX40I V 1 Disassemble PRintX 401 V and RJ 45 connection box wiring in order to route cable 2 Two mounting options are available for this unit e Option A Mounting the assembled unit to the wall using four screws threaded through holes at the top and bottom of the unit 1 e Option B Mounting the disassembled back panel to the wall after concluding this procedure re assemble unit s front panel and secure screws Option A Step 1 Remove screw covers and screws from top and bottom of the units front panel 1 Step 2 Drill holes according to position A shown on the mounting tem plate for both units PRintX 401 V and PRintX
13. on Instructions and regulations 1 Do not use your thumb to enroll Place the higher joint of your finger on the ridge lock and lower your finger onto the sensor surface make sure all other fingers are held straight to avoid creating an angle between the enrolled finger and the sensor surface incorrect positioning Synel Industries Ltd 15 Operation PRintX40I V 3 Touch the sensor s plastic casing black in order to discharge static electricity Keep your finger steady 4 Press your finger gently onto the panel avoid excessive pressure as it will blur the print 5 Make sure your finger is touching the sensor s drive ring 6 Use the same finger for enrollment as well as for verification T7 If your finger is extremely dry touch your forehead or the side of your nose before placing it on the sensor 8 Do not use a wet moist finger for scanning Note For user s convenience mount the terminal to a 1 3 meter height measured from the top end of the terminal and at a distance of 15 cm from the right side wall closer to the sensor side 16 Synel Industries Ltd PRintX401 V Maintenance 4 Maintenance You should always touch the conductive plastic before touching the PRintX P sensor in order to safely discharge any static electricity on your skin or clothing Do not e Place the fingerprint sensor close to a heating source such as a radiator or hot plate e Spill any liquids on the sensor with the
14. rd code default 1234 8 3 Key in the instruction code 12 and 0008 3 2 2 Managing Access Cards or Codes Insert Cards Into List e Cards may be entered one at a time or one directly followed by another When the green LED flashes the PRintX 401 V is ready to read cards the card s must be brought within the unit s range e Upon completion of card insertion the operation is cancelled and reverted to Programming mode after a short time out is if operation is not acknowledged within 10 sec Inserting cards can be performed following this procedure Press function keys 1 amp 2 3 times simultaneously The red LED flashes Key in the eight digit master code You are Programming mode Key in the instruction code 20 and 9999 PRintX orange LED flashes Bring user card within the range of the PRintX 40I V The PRintX s orange LED is illuminated Place user finger on PRintX sensor green LED indicates success You have 10 Sec to acknowledge e For card insertion press 1 e For exiting press 2 pp E Mo Synel Industries Ltd 13 Operation PRintX40I V Insert Codes Into List e Codes may be keyed in one at a time or one directly following another When the green LED flashes the PRintX 401 V is ready to read cards the card s must be brought within range of the unit e Upon completion of code insertion the operation is cancelled and pro moted back to Programming mode Inserting codes can be p
15. w 6 YL LED 3 Blue 7 BR 6 Synel Industries Ltd PRintX40I V Installation 2 1 3 PRintX P HOST Connection This connection provides a communication interface and power supply to PRintX P whenever a host connection is required MV 1000 Note Commonly this unit is unplugged from host It is mainly plugged in for FPU maintenance purposes 1 Place RJ 11 connection box in its hidden position on the wall 2 Connect PRintX P flat RJ 11 connector to connection box 3 Connect DC Input jack to RJ 11 connection box PRintX RJ 11 Connection box reference Wire No Wire Function Present Colour Code 1 TXD Blue 2 GND Yellow 3 RXD Green 4 NC 5 NC Synel Industries Ltd 7 Installation PRintX401 V VCC White Synel Industries Ltd PRintX401 V Operation 3 Operation 3 1 Access Control using PRintX40I V unit 1 Bring user card within range of PRintX 40I V Verification only Place user finger on the PRintX sensor 3 Compatibility between card user and finger user enables access activates door relay 4 No compatibility between user card and user finger prevents access and initiates a buzzer sound door relay was not activated The PRintX P reader allows for two basic operations Enrolment is scanning a fingerprint determining the quality of the fingerprint scan and storing a good template as a referen