AdiLight-2 User Manual

image

Contents

1. 5 4 FEATURES AND CONTROL 5 5 HOW OPERATE YOUR 6 6 CARE AND 2 2 6 7 TECHNICAL 6 1 1 7 8 1 1 Nadadala 8 3 AdiLyfe Pty Ltd AdiStem AdiLight 2 User Manual 1 INTENDED USE AND CONTENTS OF YOUR ADILIGHT 2 DEVICE Congratulations on the purchase of your AdiLight 2 Device We highly recommend you read this Manual thoroughly before starting to use your AdiLight 2 unit Whilst this device had been designed and engineered to ensure long trouble free and safe use care and attention on the part of the user are needed to help ensure maximum life 2 PRECAUTIONS AND SAFETY DO NOT Immerse the AdiLight 2 device in water Wash the unit down with water Use on a wet surface Use a wet cloth to wipe down the unit Apply any cleaning solutions or solvents to the unit Spill liquids in the light chamber Attempt to move the unit whilst in use Attempt to open the unit Modify or attempt to modify the unit in any way Any modification or attempt at modification
2. Page 5 AdiLyfe Pty Ltd AdiStem AdiLight 2 User Manual 5 HOWTO OPERATE YOUR UNIT Place on a flat dry workstation taking care not to block any of the unit s air vents or the exhaust fan Connect the Power Switch mode adaptor to the AdiLight 2 unit Connect the mains cord to the adaptor Connect the mains end of the power cord to the wall socket and turn on Turn on the Power On Switch red light around the switch will glow Place the Filled Syringe into the Light Chamber Set the Timer to required No of minutes 10mins PRP Press the Start Button and wait for the procedure to be completed To commence another cycle place a new filled syringe in the Light Chamber set the Timer and then press the Start Button To completely disconnect the power input unplug the equipment from the power outlet 6 CARE AND MAINTENANCE The AdiLight 2 unit contains very few user serviceable parts so maintenance is restricted to cleaning of the unit Wipe the unit with a soft dry cloth daily after use Keep the unit and its adaptor in a cold dry and non hostile environment In the unlikely case that the unit does not turn on check the connections of the unit to the adaptor and the adaptor to the wall socket Check the wall socket is switched on in applicable countries and the light indicator on the adaptor is on Make sure the Power Button on the AdiLight 2 unit is turned to the ON position The wall plug contains the fuse If th
3. lt Adilyfe AdiStem AdiLight 2 PhotoActivation Device For Laboratory Use User Manual www adistem com AdiLyfe Pty Ltd AdiStem AdiLight 2 User Manual The AdiLight 2 device shines one or more specific wavelengths of yellow red and or green LED light on cells in culture This is research work performed in a laboratory PhotoActivation increases cell proliferation After PhotoActivation treated cells are transferred to other equipment About AdiLyfe AdiLyfe Pty Lid is a biotechnology company which discovers develops and provides to doctors PhotoActivation and related products that address orthopedic regenerative clinical applications AdiLyfe Pty Ltd owns proprietary technologies and supplies Doctors Clinics and Medical Distributors worldwide Some Distributors also provide training to doctors and clinicians strictly in conformance with AdiStem protocols established under formal clinical trials and evidence based research For technical assistance please contact AdiLyfe Pty Ltd 1046A Dandenong Rd Carnegie VIC 3163 Australia Tel 61 3 9573 8888 Email tech adistem com Website http www adistem com Page 2 AdiLyfe Pty Ltd AdiStem AdiLight 2 User Manual AdiLight 2 USER MANUAL Table of Contents 1 INTENDED USE AND CONTENTS OF YOUR ADILIGHT 2 DEVICE 4 2 PRECAUTIONS AND SAFETY 4 3 COMPLIANCE TO INTERNATIONAL STANDARDS
4. will result in the warranty becoming void Allow untrained or non certified operators to use the device Allow use by unauthorised persons or the public Put any items apart from the syringe and contents to be activated in the light chamber Position the unit in such a way that the vents or fan exhaust is covered Attempt to reset the timer whilst the unit is operating Use any other main lead or power adaptor than what is supplied Use harsh abrasives to clean the unit Page 4 AdiLyfe Pty Lid AdiStem AdiLight 2 User Manual 3 COMPLIANCE TO INTERNATIONAL STANDARDS Unit is manufactured in an ISO accredited facility and accredited to ISO 13485 2003 ISO 9001 2008 15 14001 2004 For Users Outside of the U S ROHS compliant CE registered with EU Harmonized Standards 61010 1 2010 LVD and EN 61326 1 2006 EMC TGA registered ARTG 196875 CB Certification in accordance with 61010 1 2010 For Users in the U S ETL cETL Certification in accordance with 0161010 1 and CSA C22 2 No 61010 1 4 FEATURES AND CONTROL Your unit has the following features and controls Countdown LCD Timer On Off Button Built in Fan and Thermostat Internal Light Chamber Start Button Intermediate Buzzer sounds 3 minutes from the end of the process Buzzer sounds at the end of the process Power saving mode touching the Timer up down Button returns the unit to full power mode
5. is needs replacing ensure only the fuse rating stated on the base of the wall plug is fitted If this does not rectify the problem please contact your local AdiLyfe Distributor The main plug of the unit should be easily accessible during intended use Do not under any circumstances try to open the unit Do not use adaptors power supply units other than what is provided with your AdiLight 2 During Regular PMS visually verify that all LEDs in the test tube holder are lit If the equipment is used in a manner not specified in this manual the protection provided by the equipment may be impaired Page 6 AdiLyfe Pty Ltd AdiStem AdiLight 2 User Manual 7 TECHNICAL SPECIFICATIONS Microcontroller controlled 0 8 inch 4 digit 7 segment display green color 3 push buttons Increment Decrement Start Increment Decrement timer duration by 1 minute The Start button initiates the countdown and turns on the LEDs at the syringe holder Timer is adjustable from 1 minute to 20 minutes Temperature controlled internal Exhaust Fan Turns on automatically at 33 C when not in power save mode Turns off automatically at 28 C when not in power save mode Turns off when power save mode activates Power save mode after 5 minutes of in activity When the power save mode activates the fan is turned off if it is on 7 segment display is cleared but a slow blinking colon is displayed to indica
6. te that it is in Power save mode Pressing any key will cancel the power save mode Display reverts back to previous duration If the temperature reading inside the casing is 33C or more the exhaust fan will turn on automatically Buzzer Beeps for 5 seconds when there is 3 minutes left on the Timer Beeps continuously for 5 seconds after the Timer reaches 00 00 Internal Syringe holder Integrated LED lights 10 Red 10 Yellow 10 Green Regulatory Approvals TGA o RoHS Scheme o ETL cETL Environmental Operating Temperature 5 C to 40 C 41 to 104 F Storage Temperature 25 C to 70 C 13 F to 158 F Humidity Range 5 to max 80 non condensing Pollution degree 2 Use at altitude below 2000m For indoor use Page 7 AdiLyfe Pty Ltd AdiStem AdiLight 2 User Manual 8 WARRANTY The AdiLight 2 unit is covered by a full parts and labour warranty for 24 months This limited Warranty only covers normal use and does not cover damage caused by misuse or dropping the unit Furthermore the Warranty does not cover acts of God such as fires floods lightning earthquakes and other disasters If the unit is modified or attempted to be modified opened or serviced by anyone other than the service facilities authorised by AdiLyfe or has the serial number removed tampered with or altered the Warranty is void For more information about this Warranty or informa
7. tion if you should need to make a Warranty claim please contact your AdiLyfe Distributor Prior to the return of any unit please contact your AdiLyfe Distributor for a Warranty Claim and or return number Limitation of Liability 1 To the fullest extent permitted by law AdiLyfe expressly excludes all conditions warranties and liability whether imposed or implied by statute or by rule of law or otherwise which are not expressly set out in this Warranty and the user s sole recourse for any defect of damage to or performance standard of the Product will be under the express Warranties provided here 2 AdiLyfe s total liability and the users exclusive remedy for and all claims losses or damages arising out of any cause whatsoever in connection with the sale or supply of the product its design suitability for use or operation whether based in contract breach of warranty of merchantability fitness for a particular purpose or otherwise express or implied in fact or by law strict liability negligence or other tort or otherwise is expressly limited to replacement of the non conforming product or payment reimbursement in an amount not to exceed the purchase price of the non conforming product plus transportation charges In no event shall AdiLyfe be liable for any special indirect incidental or consequential losses or damages including without limitation any liability to indemnify the purchaser in respect of any claim b
8. y a third party lost profit downtime operating or maintenance costs equipment damage or product spoilage even if AdiLyfe has been advised of the possibility of such potential loss or damage 3 minor damages such as scratches spots pressure marks shall not entitle the user to any Warranty claim Commercial tolerances with respect to dimensions finish colour weight etc of products and all other articles manufactured by AdiLyfe or minor variations from the data stated in AdiLyfe s printed documents and descriptive literature shall neither entitle the user to any Warranty claim nor to a rejection of the products delivered For more information go to our website www adistem com Page 8