Home
Color Light Streams CLS-2 User Manual for 2010 CLS
Contents
1. une Classe Il num r s alimentation seulement Intrinsequement prot g es Ne pas utiliser pour les installations de feu Convient pour Damp Localisations Type IC Recessed 79 15216 02 REV Al 2 of 7 The New AN ENERGY FOCUS COMPAR Y Installation The CLS 2 can be used for many applications including architectural and landscape structure illumination pool spa water feature illumination etc The following considerations should be made for choosing a mounting location 1 The CLS 2 is suitable for use in damp and dry locations Do not submerge or mount in a location that is exposed to a constant water stream The CLS 2 may be mounted in a horizontal or vertical position Use the stainless steel mounting bracket Do not mount the illuminator in an explosive environment or near combustible materials 5 Do not keep the CLS 2 in ambient air temperature in excess of 150 F 66 C Lower temperatures do not adversely affect the performance of the CLS 2 Do not cover the fins or insulate the unit from air flow Do not encase the CLS 2 in concrete or bury in the earth Do not hang or use the power cord as a support for the CLS 2 as it is not a pendant light oe de Oa Using Supplied Mounting Bracket The CLS 2 should be mounted using the supplied mounting bracket The mounting bracket can be mounted to wood masonry drywall or metal by using the appropriate fasteners Make sure the mounting surface is sta
2. 3 selectable start colors Color Synchronizing The CLS 2 can color synchronize with all CLS 2 equipped Color Light Streams products and PAL series Pool Spa lights equipped with the LAL or LAU LED lamps For color synchronization all products should be connected to a single appropriate type 12VAC magnetic transformer To color synch simply turn off power for more than 1 5 seconds to ensure that all units reset to factory default mode 1 Turn on power to re energize the transformer supplying the 12VAC power to the products they should now be synchronized CLS 2 and PAL series lights w LAU lamps will need to have the DIP Switch settings in the default position all down off to color synchronize with PAL lights equipped with the LAL lamp PAL 2000 Color LED or PAL Treo Mode Selection To operate the unit turn ON the power To advance to the next color mode 1 8 just turn the power OFF then ON within 1 5 seconds until you select the required color mode If you need to reset for color synchronization purposes just switch off the power for 2 seconds and the unit will reset ready to start from mode 1 when power is applied Color Hold Timing The CLS 2 has the option to change it s cycle timing from 2 5 seconds to 10 seconds for slower color change cycle Adjust this changing DIP switch 1 as shown by the chart below Start Color Selection The choice of 3 Start Colors in mode 1 can be selected by adjusting the 2 or 3 D
3. Al 7 of 7
4. IP switch as shown in the chart below Alternate Fixed Color An alternate fixed color of Aqua instead of Red can be chosen for mode 5 only by adjusting DIP switch 4 as shown in the chart below Mode 1 Color Change Blue White Mode 2 White White Color Change Mode 3 Blue Color Change Blue Mode 4 Green fGreen Green Mode 5 Red or Aqua _ Red or Aqua Red or Aqua Mode 6 Amber JAmber JAmber Mode 7 Purple Purple Purple NOTE Rs Use the Dip n Switch to ALL OFF select the STANDARD desired POSITION SAME AS 1 3 4 GOOT OF LAL feature COLOR ALT CHANGE START COLOR FIXED TIME COLOR 79 15216 02 REV Al 6 of 7 The New AN ENERGY FOCUS COMPANY Specifications Mechanical CIO E EE EE EEE EE 80z 198g COMPOSINOO ere ae Aluminum Alloy and Polyamide Regulatory Standards lp ETL Tested to UL2108 CSA C22 2 250 0 Canadian Listed component Optical Specification Numeric Aperture NA c cc ccce cece cece eee eee eee eeeaeeeeeeenaeeees 5 Lumen Output White 73 White point 100 Green 50 red 50 Blue Electrical Specification SUD Vla ssa a a en a 12V AC Wattage Volt AMPS eeaeeeeeeeeeesaeeeeeanees OW Thermal Specifications Maximum Ambient Air Temperature 150 F 66 C Minimum Ambient Air Temperature 40 F 40 C 79 15216 02 REV
5. The New diber S ree AN ENERGY FOCUS COMPANY j Color Light Streams CLS 2 User Manual for 2010 CLS 2 12V RGB 6678 Owens Drive Suite 105 Pleasanton CA 94588 888 704 2276 toll free www fiberstars com 79 15216 02 REV Al l of 7 AN ENERGY FOCUS COMPAR Y Introduction The CLS 2 by Fiberstars an Energy Focus Company in the most efficient RGB LED Fiber illuminator available that will run maintenance free for years It has a low power consumption and a robust design that enables it to be installed in places that are unsuitable for other types of illuminators A IMPORTANT SAFETY INSTRUCTIONS 1 2 3 oS Yi gt Co p Save these instructions Read and follow all safety instructions carefully This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and hazards involved To be used with a listed Class Il power supply only Inherently Protected Not for use in fire rated installations Suitable for Damp Locations Type IC Recessed A Consignes de s curit importantes 1 2 3 Conservez ces instructions Lisez et suivez attentivemant toutes les consignes de s curit Ce produit doit tre install en conformit avec le code d installation par une personne famili re avec la construction et le fonctionnement du produit et des risques impliqu s Pour tre utilis avec
6. ble prior to installation of the CLS 2 The bracket can be secured to the mounting surface prior to installing the CLS 2 Use a 10 screw appropriate to the attachment surface The fiber should be supported by a separate means appropriate to support the fiber and for the attachment surface Do not try to support long length of fiber using only the CLS 2 as the main support No ae aa Electrical connections 1 The CLS 2 must be connected to a Class Il power supply Use a power supply that is appropriate to the installation The power source is 12 VAC power The minimum output for the source should be 5W volt amps per CLS 2 unit The connection should be made in a junction box or at the power supply 2 The lead wires are 18awg stranded and tinned copper 3 For weatherproof connections a Heyco fitting or equivalent can be used in the junction box to seal the lead cable The power cable is already sealed on the CLS 2 79 15216 02 REV Al 3 of 7 The New ibera AN ENERGY FOCUS COMPANY 4 Fiber Luminaire Compatibility Fiber Types The CLS 2 is designed for side peripheral or end emitting fiber with a numeric aperture NA of 5 or greater Lower numeric aperture fiber will work with less efficiency The composition of the fiber can be solid or stranded glass or plastic At the focal point there is virtually no ultraviolet light or heat The end of the fiber will not degrade over time as with other systems Fiber Si
7. en and exposed amp during reassembly To access the DIP switches complete the following 1 Ensure that power is safely shut off from 12V power supply You will be accessing the LED driver s internal circuit board near the power leads 2 Unscrew the Heyco compression fitting to loosen or release the fiber optic bundle Slide fiber bundle out of compression fitting so that the LED driver can be completely free of the fiber connection 3 Gently remove CLS 2 from the spring mounting clamp 4 Orient the driver so that the power cord is facing up and drooping over your hand Remove the 3 small Phillips head screws from the power cord back plate using a new 2 Phillips head screwdriver Gently separate the back plate from the body being careful to not strain the power cord connections to the board or flex the board in the body 5 Using a toothpick or mini slotted screwdriver tip gently move the desired DIP switch up to activate the desired option listed on the chart in the following section 6 Carefully place the back plate into position on the body making sure that the screw holes line up without excessive twisting of the back plate 7 Replace the 3 screws and gently tighten Reassemble the components in reverse order as they were disassembled Apply power and check for proper function 79 15216 02 REV Al 5 of 7 The New AN ENERGY FOCUS COMPANY The CLS 2 provides six 6 Fixed Colors two 2 Color effects and three
8. zes The CLS 2 is most efficient for fiber of 0 38 to 0 50 dia Small diameter fiber can be used with some loss of efficiency Mounting Fiber The CLS 2 is equipped with a 34 NPT female threaded nose fitting The common way to attach the CLS 2 is using a compression type of electrical fitting These fittings are commercially available from several sources including Heyco Kleinhuis Sealcon and Skintop For a weatherproof installation use sealing tape on the threads before threading into the nose and tighten the compression nut to the manufacturers suggested torque After installation of the compression fitting insert the fiber into the fitting so that the fiber end is flush with the focal plane Do not force the fiber past the focal plane For fibers that are less than 0 56 dia 14 2mm use an outer jacket to prevent the fiber from passing through the nosepiece aperture lose Piece moan Focal Plane Me alii A nf ENT Compression Fitting Customer Supplied Put Tefion tape on these a yo 3 Fiber Optic Cable threads for weatherproof 3 is 79 15216 02 REV Al 4 of 7 The New AN ENERGY FOCUS COMPANY 4 Color Option DIP Switches The CLS 2 has the ability to change several color options through the adjustment of the internal DIP switches Caution should be used as changing the settings requires opening the water resistant back plate of the unit Damage can occur when the unit is op
Download Pdf Manuals
Related Search
Related Contents
NETWORK THERMO RECORDER RT-12N/RS Remote Satellite Terminal RST100 User and Installation Manual OM, Rider Pro 15, 2002-04 Robertshaw Jan-01 Owner's Manual La sérigraphie sur textile foncé et supports divers 取扱説明書 デジタル・タイヤ・ゲージ 品番: 44145500 型式:JD3502 Test du Nikon F par Phot`Argus Submersible Waterfall / Utility Pumps Pompes submersibles BV 170 E - BV 290 E - B 230 - B 360 BVS 170 E Manual do Usuário Copyright © All rights reserved.
Failed to retrieve file