Home

USER MANUAL

image

Contents

1. COLOUR STORM QUAD Order code LEDJ168 USER MANUAL Colour Storm Quad WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty Colour Storm Quad Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution e Never remove warning or informative labels from the equipment e Do not open the equipment and do not modi
2. OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property Colour Storm Quad Introduction Introduction Features e DMX channels 4 6 7 11 19 64 and 67 selectable LEDs 16 x Mega Bright 8W quad colour LEDs Sound active auto run master slave and DMX modes e DOHZ flicker free LEDs Powercon in out sockets 3 Pin XLR in out sockets e 5 pin XLR in out sockets e 4 push button LCD display 0 100 dimming e Long life LEDs Beam angle 25 degrees Overview DMX In DMX Out LCD Display O L D DISPLAY Q 2 POWER OUT MODE ANTER P DOWN a Fuse Safety eye Enter Button Up Button Mode Button Down Button Power In Power Out Setup Operating Instructions The Colour Storm Quad is a DMX 512 controllable unit made up of high efficiency and Ultra Bright Quad colour LEDs and will operate in auto run master slave sound activated or DMX control modes 3 Colour Storm Quad Operation Modes Operation modes Sound Active mode To activate the unit in sound active mode press the MODE button to show SOUND MODE on the LCD screen No
3. 168 175 Flow 1 176 183 Flow 2 184 191 Flow 3 192 199 Flow 4 200 207 Flow 5 208 215 Flow 6 216 223 Flow 7 224 231 Flow 8 Speed 0 255 Speed 0 255 Speed 0 255 Speed 0 255 Speed 0 255 Speed 0 255 Speed 0 255 Speed 0 255 Speed 0 255 Speed 0 255 Speed 0 255 Speed 0 255 232 239 Flow 9 Speed 0 255 CH3 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 Flash 0 255 240 255 Sound Sensitivity 0 255 CH4 All Red 0 255 Colour select 0 255 Colour select 0 255 CH All Green All Blue 0 255 0 255 Colour select 0 255 Colour select 0 255 CH7 All White 0 255 Note that from address 0 15 and 16 255 also applies to DMX channel modes 67 19 and 11 11 channel DMX chart Master Dimmer Flash R1 G1 B1 Wn 0 255 0 255 0 255 0 255 0 255 0 255 CH8 R2 0 255 B2 W2 0 255 0 255 Colour Storm Quad DMX Programme Charts 19 channel DMX chart Master 0 15 Dimmer Flash R1 G1 B1 W1 R2 G2 B2 W2 R3 G3 B3 W3 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 CH16 CH17 CH18 CH19 64 channel DMX chart R1 G1 B1 W1 R2 G2 B
4. and DOWN buttons Speed values 00 99 00 slow 99 fast Flash values 00 99 00 slow 99 fast For the 14 built in programmes please see page 5 DMX mode To activate the unit in DMX mode press the MODE button to show DMX MODE on the LCD screen Press the ENTER button and select the desired DMX address setting by using the UP and DOWN buttons Then to select one of the 5 DMX modes 4 6 7 11 19 64 or 67 channel press the ENTER button again to choose the desired DMX mode by using the UP and DOWN buttons For the 4 6 7 11 19 64 or 67 channel DMX address information please see pages 6 7 amp 8 NOTE Once the desired settings have been selected in each of the above modes ALWAYS confirm the settings by pressing the ENTER button 4 Colour Storm Quad Built in Programme Chart 14 Built in programme chart BLAC Blackout R Red G Green B Blue W White RG Yellow STATIC COLOR GB Cyan BW L Blue RW Pink GW L Green RB Purple BLACKOUT RGBW RGB White GBW L Cyan RGW L Yellow RBW L Purple Flash00 99 RGBW White Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Speed 00 99 Flash 00 99 Speed amp Flash adjustable FADE 15 colour Fade in fade out Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Speed 8 Flesh austab Speed 00 99 Flash 00 99 Speed amp Flash adjustable FLOW 2 15 colour chase forward 8 reverse 15 colour fade chase in relay pattern
5. 2 W2 R3 G3 B3 W3 R4 G4 B4 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 CH16 CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24 CH25 CH26 CH27 CH28 CH29 CH30 W4 RS G5 B5 W5 R6 G6 B6 W6 R7 G7 B7 W7 R8 G8 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 CH31 CH32 CH33 CH34 CH3 CH36 CH37 CH38 CH39 CH40 CH41 CH42 CH43 CH44 CH45 B8 W8 R9 G9 B9 W9 R10 G10 B10 W10 R11 G11 B11 W11 R12 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 EI CH47 CH48 CH49 CH50 CH51 CH52 CH53 CH54 CH55 CH56 CH57 CH58 co ESI G12 B12 W12 R13 G13 B13 W13 R14 G14 B14 W14 R15 G15 B15 W15 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 CH61 CH62 CH63 CH64 R16 G16 B16 W16 0 255 0 255 0 255 0 255 Colour Storm Quad DMX Programme Charts 67 channel DMX chart Master 0 15 Dimmer Flash R1 G1 B1 W1 R2 G2 B2 W2 R3 G3 B3 W3 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 CH16 CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24 CH25 CH26 CH27 CH28 ESI EI R4 G4 B4 W4 R5 G5 B5 W5 R6 G6 B6 W6 R7 G7 B7 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 2
6. 55 0 255 0 255 0 255 0 255 0 255 0 255 CH31 CH32 CH33 CH34 CH36 CH37 CH38 CH39 CH40 CH41 CH42 CH43 CH44 CH45 W7 R8 G8 B8 W8 R8 G9 B9 W9 R10 G10 B10 W10 R11 G11 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 CH46 CH47 CH48 CH49 CH50 CH51 CH52 CH53 CH54 CH55 CH56 CH57 CH58 CH59 CH60 B11 W11 R12 G12 B12 W12 R13 G13 B13 W13 R14 G14 B14 W14 R15 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 0 255 CH61 CH62 CH63 CH64 CH65 CH66 CH67 Colour Storm Quad DMX Set up DMX 512 e DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DMX Linking e DMX is a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line do
7. consumption snsnnnnnnnnonennnnnnnnnnnnnnnnnnnnnnnnnnnnnnannnnnnnnnannnnnnanennnennnannannnnnna 196W Fuse o IVAN PR mM ER RES ee Control amp Programming e Data INDULcicrciiiie HHHH e Data output ss nz e e O oie tense nels cand rem i semence e DMX channels kak kk kak nr F2A Locking 3 5 pin XLR male socket Locking 3 5 pin XLR female socket DMX 512 USITT A 6 7 11 19 64 and 67
8. es not influence the DMX addressing For example a fixture assigned to a DMX address of 1 may be placed anywhere in a DMX line at the beginning at the end or anywhere in the middle When a fixture is assigned a DMX address of 1 the DMX controller knows to send DATA assigned to address 1 to that unit no matter where it is located in the DMX chain DATA Cable DMX cable requirements for DMX operation e The Colour Storm Quad can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split Colour Storm Quad DMX Set up Notice e Be sure to follow figures 2 4 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out DMX 512 in 3 pin XLR 3 pin XLR e XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground Pin 1 Ground 2 cold Pin 2 Negative FIGURE 3 FIGURE 2 Special Note Line termination e When longer r
9. forward Speed 00 99 Flash 00 99 Speed amp Flash adjustable FLOW 4 15 colour fade chase in relay pattern forward 8 Speed 00 99 Flash 00 99 reverse Speed Flash adjustable Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Speed 00 99 Flash 00 99 Speed 8 Flash adjustable Two colour chase forward FLOW 8 Speed amp Flash adjustable Speed00 99 Flash 00 99 BLAC Blackout R Red G Green B Blue W White RG Yellow 1 BLA RGBW 2 BLA RGBW GB Cyan BW L Blue RW Pink GW L Green RB Purple RGB White GBW L Cyan RGW L Yellow RBW L Purple RGBW White Two colour chase forward 8 reverse FLOW 9 Speed 8 Flash adjustable Speed00 99 Flash 00 99 BLAC Blackout R Red G Green B Blue W White RG Yellow GB Cyan BW L Blue RW Pink GW L Green RB Purple RGB White GBW L Cyan RGW L Yellow RBW L Purple RGBW White 1 BLA RGBW 2 BLA RGBW Colour Storm Quad DMX Programme Charts 4 channel DMX chart All All All All Red Green Blue White 0 255 0 255 0 255 0 255 6 channel DMX chart Master Dimmer 7 channel DMX chart Master Dimmer 0 255 1 al 16 23 Red 24 31 Green 32 39 Blue 40 47 White 48 55 Yellow 56 63 Cyan 64 71 light Blue 72 79 Pink 80 87 Light Green 88 95 Purple 96 103 White rgb 104 111 Light green 112 119 Light yellow 20 127 Light purple 28 135 White rgbw 136 143 Dream 144 151 Meteor 152 159 Fade 160 167 Change
10. fy the equipment e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors e Do not expose to flammable sources liquids or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 220v 240v e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service e Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS e WARRANTY One year from date of purchase
11. uns of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a o DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The chart below details the correct cable conversion Bin 4 D Pin XLR Lente Pin 2 Suha e kh Pin 1 GND screen BI 3 Signal A Pin 2 Signa 6 Pin 3 Signal Pin 5 N C 5 Pin XLR socket XLR socket 1 GND baren f Pin n 1 GND E orreen n Pin 2 Signal Pin 2 Signal ta E gt nal e Pin 3 Signal Pin NIC 10 Colour Storm Quad Technical Specifications Weight 8 Dimensions Technical Specifications o With DracketS oocoocococcccccccococcoconcncnoconcnccncnnnnnnnnnnnncnnrnnnnranrnnnnrnnrnnnnrnnrarannananaana 1120 x 165 x 176mm e Without brackets euennenaenannennanannenaenannennanannennanennenaenanne naeran enama 1066 x 165 x 89mm A SS Power 7 3Kgs 240V 50hz e Power
12. w press the ENTER button to select the desired sensitivity level by using the UP and DOWN buttons Press the ENTER button again to select the frequency level and adjust by using the UP and DOWN buttons SENS 00 31 00 low 31 high FAN 01 99 01 low 99 high Auto run mode To activate the unit in auto run mode press the MODE button to show AUTO RUN on the LCD screen Now press the ENTER button to select the desired freguency level by using the UP and DOWN buttons FAN 01 99 01 low 99 high Note In this mode it will run 13 built in programmes in a continuous loop Slave mode To activate the unit in slave mode first you must link multiple units together and press the MODE button to show SLAVE MODE on the LCD screen Now on the master unit press the MODE button to select the desired mode and the slave units will now run in seguence with the master unit Built in programmes To activate the units built in programmes press the MODE button to show 01 STATIC on the LCD screen Press the ENTER button to choose between the 14 built in programmes by using the UP and DOWN buttons Now press the ENTER button to select the desired speed and adjust by using the UP and DOWN buttons Press the ENTER button once more to select the desired flash value and adjust by using the UP