Home
Patriot Pro II
Contents
1. ere Model 400U 750 1000U a po mu p oo ma i TJ TJ cy CI i Patriot Pro II Controls i 52 b and Indicators se _ We Au Line Buck boost E Battery Mode PE 400E 750 1000E E R Battery Charge see page 9 00n oop olg Alarm Program fo Button a ae ww _ WwW On Standby Button RS 232 Input U Cord gt and Plug AK RJ11 RJ4S Input E Receptacle 3 Output Receptacles CU CE TL a 15 6 ENGLISH Quick Startup N 7 ENGLISH If your Patriot Pro II UPS has a removable power cord connect the power cord to the back of the unit Plug the UPS into a wall outlet Let the unit charge the battery for at least 8 hours You may use the unit while the battery charges but the battery backup runtime will be reduced until the battery is fully charged Note The On Off button must be pressed and held for about one second to turn the Patriot Pro II unit on or off To start the unit now press and hold the On Off button the bottom button on the front panel When the unit starts it will 3 a Beep then light the front panel lights turn them off and light them again Next the Patriot Pro II applies AC output to the back panel receptacles It then does a brief self test and turns various front panel lights off and on
2. 3 b After 5 seconds or less the self test ends The top and bottom green lights will come on and remain on If the unit beeps or if the top light does not remain on even though input power is available from the wall outlet go to the Troubleshooting section Switch off the equipment you want to protect and plug it into the outlets on the back of the Patriot Pro II Switch on the protected equipment one at a time If the UPS beeps an alarm when you start your equipment the UPS may be overloaded See the Troubleshooting section The bottom four lights on the front of the UPS show the of the UPS power that your equipment is using See Symbols LEDs and Audible Beeps Section for more information The RJ 11 or RJ 45 Surge Protection jacks will protect equipment that canal we uses an RJ 11 or RJ 45 connection Plug the 10BASE T network connection or phone fax or modem line for U models into the surge RJ 11 or protection jack labeled IN on the back of the Patriot Pro II Plug the protected equipment into the surge protection jack labeled OUT RJ 45 Network cabling is not provided Network only on European model do not connect any TNV equipment such as telephone fax or modem to the circuitry It may only be used for network protection purposes on E models This connection is optional It is not needed to use the Patriot Pro II Please fill out the warranty registration card and return i
3. The power supply cord is intended to serve as the disconnect device The socket outlet shall be near the equipment and shall be easily accessible With the exception of user replaceable batteries all servicing of this equipment must be performed by qualified service personnel Before maintenance or repair all connections must be removed Before maintenance repair or shipment the unit must be completely switched off and unplugged or disconnected The installation and use of this product must comply with all national federal state municipal or local codes that apply For assistance call Best Power s Worldwide Service or your local Best Power office Refer to your Patriot Pro II Safety Information Manual for additional safety instructions If the Patriot Pro II unit has been damaged during shipment call your vendor immediately If the Patriot Pro II unit is stored the batteries should be recharged every 6 months If stored above 25 Celsius 77 Fahrenheit recharge the batteries more often ENGLISH 2 UPS Features The Best Power Patriot Pro II provides protection against power problems including power outages brownouts and sudden increases in power It also provides spike suppression and line noise filtering to protect your equipment Front panel LEDs and an audible alarm keep you aware of the unit s status Use the drawings below to identify features of the unit Front and Side Views of 400 750
4. Surge high voltage or Brownout low voltage Changing the setting without this knowledge could make the problem worse Table 2 Audible Beeps Number of Beeps What It Means l every 10 seconds Line Loss The unit is on battery power See Table 3 for more information Low Battery Alarm The unit was running on battery power and shut down due 2 every 10 seconds to very low battery voltage The unit will restart automatically when acceptable power returns 3 every 10 seconds Seed Battery The battery needs to be replaced See Replacing the S every tes Battery Undercharged While on line operation low battery voltage indicates ry that the battery will provide minimal backup time 0 5 second beep re occurring every 1 Output Overload Too much load equipment second UPS Fault UPS internal failure ENGLISH 6 Troubleshooting If you have a question or problem the troubleshooting table may help See Table 3 If you need assistance phone Best Power s Worldwide Service or your local Best Power office Please have the model number and serial number located on the rear of the unit available If the unit must be returned Best Power will give you a Return Materials Authorization RMA number Phone Best Power for an RMA number before returning the unit for any reason Table 3 Troubleshooting Possible Reasons What To Do Yellow BATTERY LED on 1 Utility power outage Wait for power to return green LIN
5. Voltage Range Model U 0 to 160 VAC operating on battery and buck boost 96 to 146 VAC operating on buck boost only Model E 0 to 300 VAC operating on battery and buck boost 188 to 270 VAC operating on buck boost only Frequency 50 60 Hz auto sensing 55 65 Hz 60 Hz 45 55 Hz 50 Hz 50 60 Hz 0 5 Hz on battery Minimum Runtime minutes 400VA Model Full load 4 5 minutes Half load 17 minutes 750VA Model Full load 4 5 minutes Half load 17 minutes 1000VA Model Full load 4 5 minutes Half load 15 minutes Transfer Time 2 6 ms typical Telephone line surge suppression for U models per Bellcore 1089 1 2 50msec waveform 2kV peak Compliant to UL497A Battery Sealed maintenance free valve regulated UL 924 recognized 400 VA Models One 12 V 9 0 AH battery 750 VA Models Two 12 V 7 0 7 2 AH batteries 1000 VA Models Three 6 V 12 0 AH batteries Automatic Battery Test Automatic battery test occurs upon startup and every 14 days thereafter Alarm will sound if the battery fails this test Battery Recharge Time to 95 of capacity 400VA 750VA and 1000VA 8 hours Recharge time is lowered with reduced load Overcurrent Protection on line U Models Fused E Models 400VA Fused 750 and 1000VA Fused and Circuit Breaker Input Fault Current maximum 400E Models 6 A 750E and 1000E Models 15 A ENGLISH 12 AC input Plug Cord Information 400 U NEMA 5 15P cord attached 400 E C14 recesse
6. POWER is unable to repair or replace the product to conform to this warranty after a reasonable number of attempts BEST POWER will refund the purchase price Remedies under this warranty are expressly limited to those specified above TO THE EXTENT ALLOWED BY LAW BEST POWER DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE AND ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE ON THIS PRODUCT IS LIMITED IN DURATION TO THE DURATION OF THIS WARRANTY TO THE EXTENT ALLOWED BY LAW BEST POWER SHALL NOT BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES INCLUDING BUT NOT LIMITED TO LOSS OF PROFITS INJURIES TO PROPERTY LOSS OF USE OF THE PRODUCT OR ANY ASSOCIATED EQUIPMENT Some states do not allow limitations on how long an implied warranty lasts so that the above limitation on duration of implied warranties may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state You are advised to consult applicable state laws No warranty is made with respect to other products sold by BEST POWER which do not bear the name BEST POWER and no recommendation of such other product shall imply
7. and the receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help For Users in Canada only For all U Models This Class B interference causing equipment meets all requirements of the Canadian Interference Causing Equipment Regulations ICES 003 Cet appareil numerique de la Classe B respecte toutes les exigences du Reglement sur le materiel brouileur du Canada ENGLISH 20
8. are advised to consult applicable state laws 15 ENGLISH Best Power Offices Best Power P O Box 280 Necedah Wisconsin 54646 U S A Telephone 1 608 565 7200 Toll free 1 800 356 5794 U S A and Canada FAX 1 608 565 2221 International FAX 1 608 565 7675 Best Power Technology Mexico S A de C V Golfo de Riga 34 Colonia Tacuba M xico D F 11410 M XICO Telephone 52 5 527 8009 1 800 711 8978 FAX 52 5 399 1320 Best Power Technology Pte Ltd 19 Neythal Road SINGAPORE 628584 Telephone 65 265 6866 FAX 65 265 6636 Sola Australia Ltd 13 Healey Road Dandenong Victoria 3175 AUSTRALIA Telephone 61 3 9706 5022 FAX 61 3 9794 9150 E mail sola solaaust com au ENGLISH 16 Best Power Technology Limited BEST House Wykeham Industrial Estate Moorside Road Winchester Hampshire S023 7RX ENGLAND Telephone 44 1962 844414 Toll Free 0800 378444 FAX 44 1962 841846 Best Power Technology Germany GmbH Am Weichselgarten 23 D 91058 Erlangen GERMANY Telephone 49 9131 77700 Toll Free 0130 84 7712 in Germany FAX 49 9131 7770 444 Borri Elettronica Industriale Srl Via de Lavoratori 124 20092 Cinisello Balsamo Mi Milan ITALY Telephone 39 02 66006611 2 FAX 39 02 6122481 Appendix A Adjusting Voltage Settings When the unit is not sounding an alarm you can use the button shown below to change the following e Nominal Voltage The normal voltage
9. data Normally Open On Battery Contact A normally open contact that closes 15 seconds pulls to Common after the UPS switches to battery power Common The signal ground for all signal pins Normally Open Low Battery Alarm Contact A normally open contact that closes pulls to Common during a Low Battery Alarm This tells CheckUPS II and other shutdown software when to start a computer shutdown Plug and Play Sense for Windows 95 Remote Shutdown Shorting this pin to Common for at least 5 seconds while the UPS is operating on battery shuts the UPS off after 120 seconds Normally Closed On Battery Contact A normally closed contact that opens 15 seconds releases from Common after the UPS switches to battery power Unused Contacts consist of open collector circuits capable of switching up to 30 VDC 6 mA resistive load 11 ENGLISH Specifications Best Power reserves the right to change specifications without prior notice Line Transient Protection Passes ANSI IEEE C62 41 Category A testing Safety Compliance Model U Tested to UL1778 tested to electrical standards of UL1449 and CAN CSA C22 2 No 107 1 M95 Model E TUVIGS listed EMC Compliance Model U FCC Part 15 Class B Model E EN 55022 Class B CE EMC directive Noise RF Suppression Full time EMI RFI filtering Efficiency gt 95 on line Capacity VA Watts 400VA 250W 750VA 470W 1000VA 630W Voltage Nominal Model U 120 VAC Model E 230 VAC
10. in material or workmanship or to have been damaged through normal use 2 The reimbursement to the PURCHASER of up to 25 000 per occurrence of documented physical ENGLISH 14 damage to specified computer equipment connected to a Product where such damage could have been prevented by transient voltage surge suppression circuitry as detailed in BEST POWER s specification for the Product sold This warranty is made in addition to BEST POWER s Limited Two Year Warranty This warranty does not include any taxes which may be due in connection with replacement or repair nor any installation transportation or postage costs These expenses will be paid by PURCHASER Replacement or repair will be made at BEST POWER s Worldwide Service Highway 80 Necedah Wisconsin 54646 U S A This warranty does not cover repair or replacement because of damage from unreasonable use damage from road hazards accident fire or other casualty misuse negligence incorrect wiring and any use or installation not in conformance with instructions furnished by BEST POWER or repairs or replacements needed because of modifications or parts not authorized or supplied by BEST POWER This warranty is operable only upon the written acceptance by BEST POWER of an application by the PURCHASER on BEST POWER s standard form for the above warranty coverage for the Product sold In such application the PURCHASER shall represent that the Product sold has been properly instal
11. ribbon cable attached on top of the unit so it is out of your way while replacing the batteries 4 Remove the two screws from the interior panel to gain access to the batteries 5 Disconnect the red and black cables from the used battery pack Use the label attached to the batteries to remove the batteries from the Patriot Pro II Red Slide the new batteries into the unit Reconnect the cables to the new battery pack red to positive black to negative of lus a 8 Position the battery cables so they will not be pinched by the interior panel Install the panel with the screws Carefully snap the front cover with the attached LED panel and ribbon cable back onto the unit Dispose of old batteries properly If you followed the option in step 2 Reconnect the line cord to the Patriot Pro II and turn the unit on Reconnect the load equipment Switch on the protected load equipment one piece at a time ENGLISH 10 Communication Port The Patriot Pro II is plug and play compatible with Windows 95 The Patriot Pro II comes equipped with CheckUPS II power management software An interface cable for the following systems is provided SCO UNIX XENIX UNIX and Compatible Systems OS 2 Windows 3 X 95 and NT Novell NetWare DB 9 Pinouts Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 Pin 9 RS232 Receive Data Receives incoming RS232 communication data RS232 Transmit Data Sends outgoing RS232 communication
12. the UPS is programmed to expect and the nominal UPS output voltage under line loss conditions e Buck The input voltage at which the Patriot Pro II decreases voltage before providing output because the input voltage is too high e Boost The input voltage at which the Patriot Pro II increases voltage before providing output because the input voltage is too low e Transfer to Inverter The point at which the UPS switches to inverter battery power either because AC input voltage is very low or because it is very high Note Make sure you want to change these values before you start the procedure below Once you press the button shown for 10 seconds the values will change to the default values and any previous changes you have made will be lost If you have a question contact the nearest Best Power office or call Worldwide Service at 1 800 356 5737 or 1 608 565 2100 mm NN Do not change voltage settings when unit is operating on A l v lt Press this inverter To change the values follow these steps z l 4 button for 10 ia seconds until 1 Press the button shown until the LEDs on the front of the all of the lights Patriot Pro II blink After the LEDs blink three will stay lit SK Ty blink and the Patriot Pro II will beep for one second 2 The LEDs that are lit show which voltage settings are selected The LEDs are numbered in the drawing below to help you identify them Tables 4 and 5 show the voltage setting
13. AF obese dane ERA EREE EEN 3 A 6talinreekeeeeit aati pe neeehee ete th ESS SEES SENSE SEERE SEES SERENE 4 Symbols LEDs and Audible Beeps 065444 0b ok kee son DR eee whew Seow eS 5 ITPUBISSAUGUNS 20 A EOS RL a Pe CARE aS E Replace Te ROSES grrr AA AA bees 8 Replacement Instructions 400VA Models csscccccaeteneceeevaberaoun tad 9 Replacement Instructions 750VA and 1000VA Models 10 COMU DOT do AA IA 11 PODIO e E AR NAAA AAA E REE ES 11 Pecado raid ir 12 METE o sr E AAA eee eiens 13 Best Power O DOS ecotriribs a ncrre reta A Ad 16 Appendix A Adjusting Voltage Settings 24 vice cha sarro 17 Trademarks Windows is a registered trademark of Microsoft Corporation All other brand and product names are trademarks or registered trademarks of their respective holders 1 ENGLISH Safety Instructions IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This User Guide contains important instructions for your Patriot Pro II that must be followed during installation and maintenance of the UPS and batteries A CAUTION Whenever the unit s On Off is On there may be dangerous voltage present at the unit s outlets This is true because the unit s battery supplies power even if the unit is not plugged into the wall outlet The unit contains dangerous voltages To reduce the risk of electric shock install in a temperature controlled and humidity controlled indoor area free of conductive contaminants
14. E LED off 2 Loose plug Make sure the power cord is one beep every 10 seconds connected 3 Tripped circuit breaker 3 Reset the circuit breaker 4 Power cord failure Phone Best Power s Worldwide Service Yellow BATTERY LED on Very low battery voltage Plug the unit into a working wall outlet green LINE LED off for at least 8 hours to allow the batteries two beeps every 10 seconds to charge After recharge if the Patiot Pro II will not operate on batteries or Patriot Pro II beeps twice every 10 seconds onbatteries phone Best Power s Worldwide Service Green LINE LED on Unit has failed the battery Turn the unit off and then on to reset Yellow WARNING LED on test the Replace Battery alarm and LEDs three beeps every ten seconds Replace the battery See Replacing the Batteries on page 8 Green LINE LED on Battery not charged Use the unit on utility power wait for Yellow WARNING LED off following a power full recharge The beeps automatically three beeps every five minutes outage stop when the battery is charged to allow for a safe shutdown Yellow OVERLOAD LED is blinking The power required by the 1 Remove load equipment one beep every second equipment is too high Reduce load level until the beeping stops Yellow WARNING LED on 1 Output short circuit Remove load and reset UPS Continuous beep 2 UPS Fault 2 Phone Best Power s Worldwide Service If the Patriot Pro II s
15. USER GUIDE Patriot Pro Il 400VA 750VA and 1000VA N Y Best Power EngUsh saa teeeounaes eeu oe Patriot Pro Il 400VA 750VA and 1000VA User Guide Best Power LTM 1325A Copyright 1999 Best Power All rights reserved x If You Have a Question Best Power is committed to outstanding customer service Worldwide Service is happy to help you with your problems or questions A service technician is available 24 hours a day 365 days a year Just call Worldwide Service or the nearest Best Power office or send a fax to the Worldwide Service Fax number Please have your unit s serial number available when you call this number is on the back of the unit If you prefer you can contact Best on the World Wide Web to get more product information Best s toll free Fax on Demand service is also available 24 hours a day to give you access to technical notes and product information o Worldwide Service 1 800 356 5737 U S Canada or 1 608 565 2100 ad Worldwide Service FAX 1 608 565 7642 or 1 608 565 2509 ERREN World Wide Web Site http www bestpower com re Sales Fax on Demand 1 800 487 6813 U S and Canada iaa Service Fax on Demand 1 608 565 9499 ext 9000 Best Power Offices Section see Table of Contents lists Best offices around the world Best Power reserves the right to change specifications without prior notice Table of Contents Safety OSTUCIODS cio AAA 2 Mani ptre P Pm teehee ER
16. battery does not recharge after 24 hours in the 3 beeps 5 minute alarm state the alarm changes to 3 beeps 10 seconds indicating the battery must be replaced 7 ENGLISH Replacing the Batteries Patriot Pro IPs batteries are user replaceable and can be replaced while the Patriot Pro II has AC input applied and powers the loads This means that if necessary you can replace the batteries while the UPS is running Before you replace the batteries make sure that you read the safety information below Note If you have a power outage while you are replacing the batteries the UPS will not be able to run on battery power and your protected equipment will shut down Acavrion The batteries used in the UPS and battery pack can produce dangerous voltage and high current Therefore the batteries may cause severe injury if their terminals contact a tool or the UPS cabinet Be very careful to avoid electrical shock and burns from contacting terminals while you replace the batteries Batteries contain caustic acids and toxic materials and can rupture or leak if mistreated Remove rings metal wristwatches and other jewelry Do not carry metal objects in your pockets these objects could fall into the UPS Never allow any tool to contact both a battery terminal and the UPS cabinet or another battery terminal Do not lay tools or metal parts on top of batteries To ensure continued superior performance from your UPS and to maintain proper charger op
17. d plug 750 U NEMA 5 15P cord attached 750 E C14 recessed plug 1000 U NEMA 5 15P cord attached 1000 E C14 recessed plug AC Output Distribution 400 U 4 NEMA 5 15R 400 E 4 C13 10A 750 U 6 NEMA 5 15R 750 E 6 C13 10A 1000 U 6 NEMA 5 15R 1000 E 6 C13 10A Load Compatibility Can support 100 power factor corrected switch mode power supply load Audible Noise lt 40 dBA at one meter Ventilation Air around the unit must be free of dust chemicals or other materials that corrode or contaminate Air must be free to move around the unit Operating Temperature 32 104 F 0 40 C Storage Temperature 5 122 F 15 to 50 C Battery life is reduced above 77 F 25 C If the Patriot Pro II unit is stored the batteries should be recharged every 6 months If stored above 77 F 25 C recharge the batteries more often Humidity 0 95 RH non condensing Altitude 3000m 10 000 ft max Dimensions Height x Width x Length 400VA 6x 4x 14 25 in 155 x 100 x 363 mm 7SOVA 8 25 x 6 5 x 14 25 in 213 x 163 x 363 mm 1000VA 8 25 x 6 5 x 14 25 in 213 x 163 x 363 mm Weight 400 17 5 lbs 7 5 kg 750 31 lbs 14kg 1000 35 5 lbs 16 kg Warranty LIMITED TWO YEAR WARRANTY Standard Warranty For All Purchases BEST POWER a division of SPX Corporation hereinafter called BEST POWER warrants that each product sold by BEST POWER is compatible with existi
18. e line cord On the bottom of the Patriot Pro Il remove the Phillips screw at the end of the battery door and slide the door off Use the flap attached to the battery to lift it out of the unit Disconnect the battery cables form the old battery Dispose of the old battery properly Connect the battery cables to the new battery red to positive black to negative Carefully install the battery back into the Patriot Pro II Slide the battery door back into place and secure with the Phillips screw removed in step 3 If you followed the option in Step 2 Reconnect the line cord to the Patriot Pro II unit and turn the unit on Reconnect the load po equipment Switch on the protected load le equipment one piece at a time 9 ENGLISH Replacement Instructions 750VA and 1000VA Models 1 Phone Best Power s Wordwide Service to order a replacement battery pack It must be the same type and rating as the original batteries See Battery infromation in Specifications 2 If it is necessary the batteries may be replaced while the Patriot Pro II is running with the protected equipment attached Option You may switch off and unplug the protected load equipment from the Patriot Pro II Then turn off the Patriot Pro II and disconnect the line cord 3 Pull the top of the plastic front cover forward then release the bottom of the front cover and carefully pull it away from the unit Place the front cover with the LED panel and
19. eration you must replace the UPS batteries with the same number and type of batteries These batteries must be the same type as the original batteries valve regulated low maintenance The replacement batteries should have the same voltage and ampere hour rating as the original batteries Assume that old batteries are fully charged Use the same precautions you would use when handling a new battery Do not short battery terminals with a cable or tool Batteries contain lead Many areas have regulations about disposing of used batteries Please dispose of old batteries properly DO NOT dispose of batteries in a fire because the batteries could explode Do not open or mutilate batteries Released electrolyte is harmful to the skin and eyes It may be toxic This equipment may produce ozone Take precautions to ensure that the concentration of ozone is limited to a safe value 0 1 ppm 0 2 mg m3 calculated as an 8 hour time weighted average ENGLISH 8 Replacement Instructions 400VA Models NL 0 Phone Best Power s Worldwide Service to order a replacement battery pack It must be the same type and rating as the original battery See Battery information in Specifications If it is necessary the battery may be replaced while the Patriot Pro II is running with the protected equipment attached Option You may switch off and unplug the protected load equipment from the Patriot Pro II Then turn off the Patriot Pro II and disconnect th
20. led and grounded in accordance with instructions received from BEST POWER and the PURCHASER shall also specify the computer equipment to which the Product sold has been connected and the location of the computer equipment This warranty will not apply to any equipment not specified in the application by the PURCHASER as protected equipment EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY AND BEST POWER S LIMITED TWO YEAR WARRANTY BEST POWER MAKES NO OTHER WARRANTIES AND TO THE EXTENT ALLOWED BY LAW BEST POWER DISCLAIMS ALL OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE REMEDIES UNDER THIS WARRANTY ARE EXPRESSLY LIMITED TO THE REPAIR OR REPLACEMENT OF PRODUCTS AND THE REIMBURSEMENT SPECIFIED ABOVE AND TO THE EXTENT ALLOWED BY LAW ANY CLAIMS FOR LOSS ARISING OUT OF THE FAILURE OF PRODUCTS TO PERFORM FOR ANY PERIOD OF TIME OR SPECIAL INDIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES OR OTHER ECONOMIC LOSS ARE EXPRESSLY EXCLUDED Some states do not allow limitations on how long an implied warranty lasts so that the above limitation on duration of implied warranties may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from state to state You
21. ng commercially available computer equipment with enclosed power supplies and is free from defects in materials and workmanship under normal use and service This warranty is applicable only to the initial retail purchaser PURCHASER and is not transferable The duration of this warranty is two 2 years from the date of the first retail sale or the date of delivery to the PURCHASER whichever occurs first subject to the following conditions If the PURCHASER discovers within the duration of this warranty a failure of the product to perform compatibly with presently existing computer equipment or a defect in material or workmanship the PURCHASER must promptly notify BEST POWER in writing within the duration of the warranty or not later than one month after expiration of the warranty BEST POWER s obligation under this warranty is 13 ENGLISH limited to the replacement or repair subject to the conditions specified below of such product returned intact to BEST POWER which shall appear to BEST POWER upon inspection to have been either incompatible or defective Replacement or repair will be made at BEST POWER s Worldwide Service Highway 80 Necedah Wisconsin 54646 U S A Such repair or replacement shall be at BEST POWER s expense This warranty does not cover any taxes which may be due in connection with replacement or repair nor any installation removal transportation or postage costs These expenses will be paid by PURCHASER If BEST
22. or constitute any warranty with respect to them This warranty does not cover repair or replacement because of damage from unreasonable use for example only damage from road hazard accident fire or other casualty misuse negligence or incorrect wiring and any use or installation not in conformance with instructions furnished by BEST POWER or repairs or replacements needed because of modifications or parts not authorized or supplied by BEST POWER LIMITED WARRANTY Transient Voltage Surge Suppression Circuitry For U S and Canadian Purchasers Only BEST POWER a division of SPX Corporation BEST POWER hereby warrants the transient voltage surge suppression circuitry in each FERRUPS FORTRESS PATRIOT UNITY I CITADEL or SPIKEFREE product hereinafter called Product sold by it for installation in the United States of America and Canada to be free from defects in material and workmanship under normal use and service for the lifetime of the Product beginning with the date of sale to the initial retail purchaser subject to the following conditions This warranty is applicable only to the initial retail purchaser hereinafter called PURCHASER is not transferable and is limited to the following remedies 1 The replacement or repair of the transient voltage surge suppression circuitry in each Product that is returned intact to BEST POWER and which shall appear to BEST POWER upon inspection to have been defective
23. running on AC input power the display will change 7 SN SECONDS to back to the percent of full load The new values will take save your effect after the display returns to normal mode e changes ENGLISH 18 Table 4 Voltage Settings for U Models 400U 750U and 1000U LEDs Lit 2 3 4 Default To Inverter Input AC is Low Nominal Buck To Inverter Voltage Input AC is High m E O E E INICIAN E ION INIA om Im mo po Ys 7 Cmo o o BOE BER INN TET TET ENGLISH For Users in the United States only For all U Models Note This equipment has been tested and found to comply with the limits for a Class B device pursuant to part 15 of FCC Rules These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment
24. s for each possible combination of LEDs 1 1 For example by default LEDs 2 3 and 4 will be lit see 2 2 diagram If your UPS is a U model you will find this combination of LEDs in the first row of Table 4 This row 3 3 4 4 5 5 shows the following e With 96 volts input or lower the Patriot Pro II switches to battery power e When input voltage drops to 109 the Patriot Pro II begins to increase the output voltage e 120 is the nominal or expected input voltage e When input voltage rises to 130 the Patriot Pro II begins to decrease the output voltage e With 146 volts input or higher the Patriot Pro II switches to battery power 17 ENGLISH 6 6 LED Numbers Default Setting 3 Use the appropriate table on the next page to decide EN which combination of settings you need note which Press this button LEDs must be lit for this combination Then briefly Se BRIEFLY to about 1 second press the button shown to move to the fay scroll through the next combination of LEDs If you hold the button in settings longer than 10 seconds the Patriot Pro II will save the QS Y VA setting that is displayed Continue pressing the button until the proper LEDs are lit ee 4 Once the correct LEDs are lit continue to hold the button Press this button for 10 seconds to save your changes If the Patriot Pro II saa for 10 is
25. t short circuit of runtime remain A 0 25 A UPS Fault overcharge Table 1 Symbols and LEDs Symbols and LEDs What It Means AC LINE Steady Acceptable input power is present The unit is Green running on line power Off No input power is present or the unit is switched off Blinking The unit is boosting or bucking utility power LINE CORRECTION Boost Automatically increases low input power to prevent Green the unit from switching to battery Buck Automatically decreases high input power to prevent the unit from switching to battery BATTERY MODE o Yellow The unit is running on battery power OVERLOAD D LED Yellow Output Overload Refer to Tables 2 and 3 WARNING D LED Yellow Replace the Battery or UPS Fault Refer to Tables 2 and 3 5 ENGLISH To silence an alarm press the ALARM SILENCE button on the front panel The beep will stop but the alarm light will stay on Note Silencing the alarm does not solve the problem that caused it See Tables 2 and 3 If your Patriot Pro II runs on batteries frequently because the input utility line varies often you may want to adjust your Patriot Pro II to accept wider voltage variations before switching to batteries Appendix A describes how to adjust the Patriot Pro II from the front panel in response to specific utility power problems You should have an electrician check your nominal line voltage and determine if the problem is due to a
26. t to your local Best Power office If you are in the U S A or Canada and you would like to activate the Warranty for Transient Voltage Surge Suppression please return the registration card within 10 days of installation Symbols LEDs and Audible Beeps The front panel LEDs and an audible beep indicate the unit status The unit beeps whenever the unit is on battery power or an alarm is present See Table 2 for information on beep coding In the figure below bucking means that Patriot Pro II is reducing high input voltage and boosting means Patriot Pro II is increasing low input voltage Steady Patriot Pro II is operating on AC line A Blinking Patriot Pro II is bucking or boosting input AC line Steady Patriot Pro II is operating on batteries CY m AC Line Operation Battery Operation N Blinking ALARM Condition A B C and D indicate A B C and D indicate D per cent of full load battery charge mua C UPS shutdown due to output overload time out A B C amp D with D flashing A B C amp D 75 100 e B UPS failed the battery test load 110 or higher E R B C amp D 50 75 B B amp C UPS shutdown due to command from A B C amp D 75 100 communication RS232 remote shutdown C amp D 25 50 il or External SNMP A B amp C 50 75 A D 0 25 when D is A amp B UPS shutdown due to main relay failure A amp B 25 50 flashing less than 2 minutes or outpu
Download Pdf Manuals
Related Search
Related Contents
Samsung 712N ユーザーマニュアル AP OPTIMA 3 Manuel Instruction Sheet For JIMS No. 2051, 2052, 2053, & 2054 Damage manual 8 août 2012 Duodenoscope TJF Q180V - Olympus - Information de Makita 9501BKLT User's Manual SERVICE MANUAL AE-5 CHASSIS MANUAL DE INSTRUÇÕES INDICADOR MODELO UPR Copyright © All rights reserved.