Home
        Idromed 5 GS User Manual
         Contents
1.   insensitivity to pain                gt     gt              Prolonged usage of high frequency surgery units on a patient can cause burns under  electrodes     Application of the electrodes close to the ribcage can increase the risk of ventricular  fibrillation     Effective current densities over 2 mA cm  at all electrode faces require higher  attention from the user     During treatment the electric circuit needs to be completed constantly   i e  maintain  at least one hand or foot in each tub     Conductive material  e g  metal  water pipes etc   must not be touched during  treatment     All jewellery on hands and feet must be removed before starting treatment     Any damage to skin  minor injuries  scratches etc   on the palms of the hands  soles  of the feet  cuticles or at the armpits must be coated with vaseline or a fatty cream  before treatment  as current permeability will be higher than normal on those spots   Please do only cover these spots     Current intensity is set according to individual requirements of the user  The ideal  current intensity evokes a pleasant  tingling sensation  not on the treatment of the  armpits   The values listed in these instructions are the maximum values allowed   Current intensity chosen by the user  however  should normally be much lower   otherwise there is a danger of burning the skin  e g  the usual range for the  treatment of the armpits is about 1     2 mA      Moisten the sponges from inside and outside  until they don   t 
2.  a  For the best results and for your own security  the unit should only be used with  original accessories from the manufacturer     b  For treatment you should separate the two parts of the case  To do this  open the case  completely  put it on a plain surface and separate the 2 parts carefully in opposite directions   see arrows on the hinges on the case     c  Fill the 2 treatment tubs with tap water to a depth of approx  3 4 cm  finger and toe joints  should be just covered   Please see also the warnings on page 10  point 4 3     d  Connect one of the cables to one of the plate electrodes and to the     connection on the  front of the idromed   5 GS     e  Connect the 2nd cable of the electrode with the other electrode and with the     connection on  the front of the idromed   5 GS     f  Place the electrodes 1 in each tub and cover the electrodes with the distance grids     g  Connect the plug of the power supply to the rear of the idromed   5 GS and plug the power  supply to a mains socket  220 230 V   50 Hz   The green control lamp on the power pack is  now alight         Dr  K  H  nle Medizintechnik GmbH idromed 5GS  ss 1919gjgqgqgjgjggggg gg aaa OPERATING INSTRUCTIONS    2 4  TREATMENT    If possible  treatment should be performed once a day initially  Treatment should last 10 15  minutes  depending on the doctor   s prescription  Normally  after 10   15 treatments  a normal  hydrosis level is reached and the skin moisture is normalized  The intervals of treatment s
3.  a danger of burns  if the sponges are too dry     Attention  there is a danger of burns  if the metallic  electrodes are in direct contact with the skin     Use the 2 electrode cables to connect the electrodes with the  positive and the negative pole of the unit     Switch on the unit by pushing down the turning knob     Pay attention that the turning knob is on switch setting    Self test  armpits 5nA  hands 15mA    feet 25mA  Set the therapy a  current  mA  Place your hands  feet or    armpit sponges    Maximum  Values     Therapy time is  running     Pma    Remaining time 9 min                 The unit carries out a self test  This action takes some seconds     Adjust the required current intensity with the turning knob  A  turn to right increases the current intensity  A turn to left  decreases it  Please note also the maximum values permissible    for the treatment of the armpits max  5 mA  ideal 1     2 mA     Complete the circuit  For this put one sponge electrode under  each armpit     Attention  Because of the compression  water may leak  from the sponge electrodes  Put for example a towel  underneath to absorb the water     For an optimal accomplishment of the treatment of the armpits   please proceed as follows             Dr  K  H  nle Medizintechnik GmbH idromed 5 GS  OPERATING INSTRUCTIONS    Regulate the current by turning the knob right or left until you  feel a soft tingling sensation at the armpits     Turn the knob to the left until the tingling sensation 
4. AL COMPATIBILITY    idromed   5 GS uses high frequency energy exclusively for its internal function  Therefore its HF   emission is very low and it is unlikely that surrounding electronic devices are disturbed    HF emissions acc  to CISPR 11  group 1     idromed   5 GS is determined for the use in all facilities  including residential areas and such  facilities connected directly to an official supply network  which also supplies buildings and  residential buildings   HF emissions acc  to CISPR 11  class B     Portable and mobile radios should not be used at a closer distance to the idromed   5 GS  including cables than the recommended security distances in the table below     Nominal capacity of Security distance depending on the transmitter frequency m    the transmitter 150 kHz   80 MHz 80 MHz   800 MHz 800 MHz   2 5 GHz              Dr  K  H  nle Medizintechnik GmbH idromed 5GS  OPERATING INSTRUCTIONS    2  APPLICATION OF THE IDROMED   5 GS  2 1  FIELDS OF APPLICATION    Condition  Used for the treatment of the following conditions     e Hyperhidrosis    2 2  CONDITIONS OF APPLICATION   idromed   5 GS has been designed for operation in dry rooms with an ambient temperature from  10  C to 45      Protect the unit against chemical vapours and never operate it in explosive areas     2 3  PREPARATION OF THE TREATMENT    The idromed   5 GS is operated with the power supply  IDROMED AC AC ADAPTER  Typ  FM  6299M   After the following preparations your unit is ready for use    
5. L x W x D   290 mm x 390 mm x 110 mm  L x W x D     2 5 kg    Power pack  230 V    50 Hz   Type  FM 6299M    25 mA an 2 KQ  infinitely variable from 0     25 mA      0 5   24V      The unit has an electronic current limiting device  In the event of  a functional error the output current is automatically cut off and  the orange lamp will be alight  Once the unit has been switched  off  the lamp will be out     ll  all insulated  lia    IPX1    C Enz    A L T  Lichttherapietechnik GmbH  Thura Mark 10    D 06780 Zorbig 13488205    Dr  K  Honle Medizintechnik GmbH  Viktor Frankl Str  20   D 86916 Kaufering   Tel   0049 8191 30555 0   Fax  0049 8191 30555 50 Sy  E Mail  medizin drhoenle de  http   www drhoenle de            gt            TUV    st         5  5S  D eS  Ny  Rey    O    12    
6. OPERATING INSTRUCTIONS    idromed   5 GS    Art  No  100001  Art  No  100003       Before putting the unit into operation and starting treatment  read this  operating manual carefully      100001 3   S0408 e    z     Dr  K  H  nle Medizintechnik GmbH idromed 5 GS  OPERATING INSTRUCTIONS    Supplied Items   Please ensure that all items are present   e idromed   5 GS  basic unit    e power supply   e 2x aluminium plate electrodes nickel free  e 2x electrode cables   e 2x distance grids    e shock proof case  the 2 parts of the case are used as treatment tubs    optional accessories        e 2x nickel free electrodes with sponges  from eudermic material  for  treatment of the armpits    e 2 x large treatment tubs  art  no  995130   e 2x distance grids for large treatment tubs  art  no  995131        Content   1  Important information on idromed   5 GS      essscssssssscessessscsssesesseseeveeeesenees 3  dale SAlCUY IMONMAUNON cate ccccctdecscneveassdentueonadersenysenuvandenswesatsusudacndesveeostacdeaeneneveessees 3  1 2  Symbols and warning on the UNit              cccccccsececeeeeeeeeceeeeceeeseeeeeueesseeeaeeesaes 4  1 3  Electromagnetical compatibility              cc ecccecceeeceeeeeeeeeeeseeeseeeseeeteeeteeeeeeeeeeens 4  2  Application of the idromed   5 GS      csssesssssesessessessssessesseseeseseesesserenseseerenss 5  ZN Fed c OF Ap OIICAU OM er 5  2 2  Conditions Of Application             cccccccccceecceceeeeceeeeeseeeeseeeeeseeeeeseesesseeeeseeeesseeeeas 5  2 3  Pre
7. drip  do not wring  them out  If the sponges are too dry  there is a danger of burns    Attention  there is a danger of burns  when the metallic electrodes are in direct  contact with the skin  When treating armpits  the sponge electrodes have to be kept  still and with constant pressure under the armpits  otherwise fluctuations of current  will occur on the display of the unit     Never short circuit the metallic electrodes            Dr  K  H  nle Medizintechnik GmbH idromed 5GS  OPERATING INSTRUCTIONS    Proper use    The idromed   5 GS is an iontophoresis unit for the treatment of hyperhidrosis on the hands and  feet and in the armpits     The operator undertakes to observe the prescribed schedule for inspection and maintenance work  and the replacement of consumables     The observance of the safety instructions and regulations in these operating instructions and the  accident prevention rules and regulations prevailing at the place of use belong to the proper use of  the unit     The company Dr  K  Honle Medizintechnik GmbH shall not be liable for any damage caused by  improper use of the equipment     1 2  SYMBOLS AND WARNING ON THE UNIT      Anode   Alternating current        Cathode o  Units of protection class Il    AN Attention  See operating instructions  To  ention  See operating instructions  X   i     p a Ng   Unit contains electronic parts      iX  and may not be disposed of in  Application device of type BF        household rubbish        1 3  ELECTROMAGNETIC
8. ends   Go through with the treatment with this determined current    Set the therapy intensity     current  P mA When treating  15 minutes  the armpits  the sponge electrodes  Place your hands  feet or have to be kept still and with constant pressure under the  armpit sponges armpits  Otherwise there will occur fluctuations of current at the  display of the unit or the unit can display a malfunction  information     Therapy time is 2 lf there is a break in treatment  the unit retains the  running  UO remaining treatment time     R Tal im min  NENN   l  an N If you feel a tingling sensation or burning  the current  AN intensity is too high and must be scaled down        Take your hands   feet or  armpit sponges out    At the end of the treatment remove the sponge electrodes from  the armpits        Please Turn the knob to the switch setting  e  and switch off the unit by    pushing down the knob     switch off  the machine        Always check the position of the turning knob   Position e  immediately after  switching on the unit and the self test completes     3  IMPORTANT TIPS AND INFORMATION    e To simplify therapy the current intensity in mA for your treatment  pleasant tingling sensation      aside from the treatment of the armpits  is displayed and can be set again consistently     e The maximum current and voltage are limited by safety limits prescribed for electrical medical  equipment  Nevertheless  do not remove your hand and or feet from treatment tubs during the  s
9. ession  keep the current circuit closed   Take care  that the unit is not switched off during  treatment     e The inhibition of sweating is much more pronounced at the positive pole than at the negative  pole  In order to optimize the therapeutic effect  you should therefore switch polarities before  every 5  treatment session  To do this  you have only to swap the electrode leads     e Please take care  that the water you are using is normal tap water and has not been treated  with a water softener before  That reduces the conductibility of water and treatment can be  make only conditional or none            Dr  K  H  nle Medizintechnik GmbH idromed 5GS  OPERATING INSTRUCTIONS    4  PROBLEMS AND HOW TO SOLVE THEM    PROBLEM SOLUTION    4 1  The green lamp on   In brightly lit rooms  it can be difficult to see whether the lamp is on or  the mains plug not  Shade the lamp with your hand to check  whether it is working   IDROMED ADAPTER    properly     does not work  The wall socket may be defective  Please connect the unit to another    wall socket or check whether the wall socket in question is working  properly     4 2  The unit shows on  the display  At a failure malfunction the unit s output current stops automatically and  the unit displays a malfunction message  Switch off the unit and switch it  VEA on again  If the error lamp is still alight  please contact Customer    Switch off the machine  Services     4 3  Current intensity is   Check the connections of the plug a
10. he same  procedure also to private users     7  WARRANTY AND LIABILITY    Generally  the general Terms of Sales and Delivery of the company Dr  K  H  nle Medizintechnik  GmbH shall apply  These shall be submitted to the operator upon the signing of the contract at the  very latest  The warranty for the idromed   5 GS is 24 months  Warranty and liability claims are  excluded in case of personal injury or damage of property if these are attributable to one or more  of the following causes     e The use of the idromed   5 GS for a purpose other than that for which it is intended  e Unauthorized structural modifications on the idromed   5 GS    e Failure to observe the information contained in the Operating instructions on the  commissioning  maintenance and operation of the unit    e Repair work performed by persons not authorized by the company Dr  K  Honle  Medizintechnik GmbH    e Catastrophes caused by foreign bodies or acts of God    11    Dr  K  H6nle Medizintechnik GmbH    idromed   5 GS    OPERATING INSTRUCTIONS    8  TECHNICAL DATA    Type  Art  no     Dimensions of the unit  Dimensions of the suitcase    Total weight  unit  suitcase and    accessories   Current supply    Fan Out current  Accuracy  Nominal input voltage    Fuse protection    Protection class   MDD classification  Protection against intrusion  of liquids   CE Mark    Manufacturer    Exclusive sales     Subject to technical alterations      idromed   5 GS   100001   100003  GB    210 mm x 120 mm x 70 mm  
11. hould  now be extended gradually   1st week   every 2 days  2nd week   every 3 days  until there is just  one treatment per week     The inhibition of sweating is much more pronounced at the plus pole than at the minus pole  In  order to optimize the therapeutic effect  you should therefore switch polarities before every  5  treatment session  To do this  all you have to do is swap the electrode leads     The maximum values permissible are     e For the treatment of the hands  15 mA  e For the treatment of the feet or of hands and feet  25 MA  e For the treatment of the armpits  5 mA    If the current intensity selected is too high  you may experience an unpleasant tingling  sensation in the extremities treated during the session  If this occurs  a lower current  intensity has to be selected otherwise there is a danger of burns        2 4 1  TREATMENT OF HYPERHIDROSIS ON THE HANDS AND OR FEET    Do not switch off the unit  during treatment     Separate the two parts of the case   treatment tubs  as described in point  2 3 6  and place in front of the  idromed   5 GS on the table  Connect  the electrodes as described in point  2 3     E Switch on the unit by pushing down  the dark grey current intensity knob        Self test  Maximum armpits EmA Check that the intensity knob is on switch setting         Values  HS Se    The unit carries out a self test  This action takes some seconds   feet 25mA    Set the therapy T Adjust the required current intensity with the knob  A turn t
12. nd electrodes and the function of  adequate  the unit     Please check if the water you are using has been treated with a water  softener  By using softened water  the conductivity is reduced  In this  case please use untreated tap water or use non carbonated  still   mineral or table water     For the treatment of the armpits  check if the sponges are still moist  enough  as in the description under point 2 4 2     lf current intensity is not adequate despite the above mentioned points   please contact the Customer Service     4 4  The display shows   Check if the lamp is lit on the plug unit  See point 4 1    Check the  nothing  functioning of the socket   Press the on off switch several times  turning knob      If you have further problems please send the unit to the manufacturer  for repair        If you have further problems or to order spare parts please apply to your locally retailer     10           Dr  K  H  nle Medizintechnik GmbH idromed 5GS  OPERATING INSTRUCTIONS    5  CLEANING AND CARE    After each treatment session  empty the treatment tubs and dry the tubs  the electrodes and the  cable with a towel  Disinfect the treatment set regularly with a normal commercial disinfectant     Discoloration of the surface of electrodes after the initial therapy sessions are quite normal     6  MAINTENANCE    The manufacturer recommends to check the unit every 2 years through our customer service    This applies only to commercial users  Nevertheless we generally recommend t
13. o  current  mA right increases the current intensity  A turn to left decreases it   Place your hands  feet or Please note also the maximum values permissible   see point  armpit sponges 2 4      Ue inet Ian Complete the circuit  For this put each hand or foot in the water   ST ea filled treatment tubs  The correct intensity of current is achieved  when you experience a pleasant tingling sensation        Dr  K  H  nle Medizintechnik GmbH idromed   5 GS    Set the therapy 7  current  mA  Place your hands  feet or    armpit sponges    Therapy time is    running  mA  Remaining time 11 min     Take your hands   feet or  armpit sponges out    malstckrs   switch off  the machine           OPERATING INSTRUCTIONS    If you do not experience a tingling sensation or the intensity of  current is too high the current intensity should be adjusted  accordingly     For treatment of feet turn the knob right or left to the desired  value  tingling sensation      For treatment of the hands adjustments should be made by  another person or you would break the circuit by taking one  hand out of the tubs     Whilst adjusting the current  hands may be taken out of the  treatment tubs and while the unit is still running without  any danger     AN Please dry your hands before regulating the current  at the unit     Regulate the current by turning the knob right or left and close  the circuit again by putting again your hands in the treatment  tubs  Repeat this process until you feel a tingling sensati
14. on with  the adjusted current     Therapy time takes 15 minutes     If there is a breaking in treatment  the unit retains the  remaining treatment time     At the end of the treatment time take your hands and or feet out  of the treatment tubs     Turn the knob to the switch setting  e  and switch off the unit by  pushing down the knob     If you need to treat both hands and feet simultaneously  take one treatment tub for your  hands and the other treatment tub for your feet     Check after the switching on of the unit and the self test always the position of the  turning knob   Position e     After each session  please empty the tubs and dry the tubs  the electrodes and the cable with a    towel     idromed   5 GS    OPERATING INSTRUCTIONS    Dr  K  H6nle Medizintechnik GmbH    2 4 2  TREATMENT OF HYPERHIDROSIS AT THE ARMPITS    Before the treatment clean the armpits with clear water  in order to remove any cosmetics  and so to avoid any irritation of the skin     For treatment of the armpits use the 2 optional sponge electrodes with the sponges        optional accessory    armpit electrodes with sponges   art  no  995100        AN Do not switch off the unit during treatment     Moisten the sponges together with the electrodes in a water  bath for about 30 seconds  Press the water from the sponges  until they do not drip  do not wring them out   The more water  remains in the sponges  the better the current will be directed to  the areas which have to be treated     There is
15. paration of the MCAUNE Wis ssiceciweunvencianintousaineinsssinciuerdsnanchameamenuwenmwemamesai 5  2A PEN eea E E EAEE EE EEEL EEEE 6  2 4 1  Treatment of hyperhidrosis on the hands and or feet                ccceseceeeeeeeeeeeees 6  2 4 2  Treatment of hyperhidrosis at the armpits              cccccececeeeeeeeeeeeeeeeeeeseeeeseeeeees 8  3  Important Tips and INfOrmatiONn              cccccscseeeeeeseeeeneeeeseseneeeeneeeneeeeneeeeeenens 9  4  Problems and how to Solve thei               ccccccsseceeeesseeeseseseeeesseneseneseneseness 10  5  Cleaning ANG Care wjiiccsctceesiscesncct sateen cons vaceutenectenensasccuauawncenivesaasntaneeconnwuias 11  6  MaiM ena NGE aisse EEE aaa 11  7  Warranty and Liability aiiscctcouiscetsentcteasccinecanatsnbscnsesuedeusacuseaetuswesassnavnecaeasubes 11  8  WCC MGIC AN Abe aiia a 12    Dr  K  H  nle Medizintechnik GmbH idromed   5 GS    1   1 1     A     re    A  A    OPERATING INSTRUCTIONS    IMPORTANT INFORMATION ON IDROMED   5 GS  SAFETY INFORMATION    Symbol for important safety instructions  Please follow these instructions carefully  to prevent health risks and damage to property     In case of the following conditions the idromed   5 should not be used or should only  be used after consulting your doctor     cardiac arrhythmia   electronically controlled implanted devices  e g  pacemaker   metallic implanted devices in the area where the current flows  metallic intrauterine implanted devices  loop    pregnancy   bigger skin diseases 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Urban Factory UST01UF speaker set  Samsung AP50Q1CNHAC دليل المستخدم  Faronics Insight User Guide  Tx II Transmitter - Instrumentation GDD  PDF KNOPPIX HACKS  avvertenze importanti important safeguards instructions  Page 1 Page 2 は薫ってい翼こと榊して 鷹 ・ ウィンカ`ークイザードラゴン  Datenblatt Ladegerät 57.4V 6A Li-Ion  設定マニュアル(1.27MB) - IDEC AUTO  Singer CLASS 18 User's Manual    Copyright © All rights reserved. 