1.  also want to insure the package     Returning Products for Service  outside the United States   For the separate international customs documentation form that you  complete to accompany the shipment  please state or designate that the  enclosed products were originally manufactured in the USA and are  being returned to the manufacturer for repair service  Value of the  equipment listed for customs purposes should be zero     31         Product Registration      Please go to www ikelite com to register your Ikelite housing within 15  days of purchase           Ikelite Underwater Systems  50 West 33rd Street  Indianapolis  IN 46208 USA    www ikelite com    6808 1_Nikon_D80_03 0712    
2.  an external External Strobe Connector  strobe  connect the housing and Waterproof Cap    hotshoe connector  Slide  the connector into the  hotshoe mount on the  camera from the back of the  camera as shown  Slide the  connector forward until it  stops  Due to limited  clearance between the  camera hotshoe mount and  the housing back  the  hotshoe connector should  be attached before the  camera is secured with the Hotshoe  mounting bolt  Connector         Housing Back    OL       Attaching Camera to Housing Tray    Remove the back from the housing  The mounting tray for the camera is  secured to the housing back  Position the camera and lens on the  camera tray  and then secure it with the mounting bolt which threads into  the camera   s tripod socket    Use a flathead screwdriver  recommended  or coin to tighten the  Mounting Bolt so the camera bottom is flush against the tray                                Camera Tray              Mounting Bolt    Installing Camera in Housing  Before installing the camera  pull out on the controls in the front section of  the housing  This will allow the camera to slide in easier  Once the camera  is installed and the lid snaps have been closed  return the controls to their  operating position     11    Closing the Housing housing back    1  Place housing face down in your lap    2  Check to see that there is an o ring on  the housing back that is clean and in its  proper location    3  Guide the back onto the housing  The  o ring should t
3.  feet  1 8m  will not have much color  regardless of strobe power      Photograph in clear water  do not stir up the sand or silty bottom  If  backscatter becomes a problem in the environment you are  photographing  an external flash will help eliminate much of the  backscatter    29    Photo Tips   continued      Many digital cameras have a slight lag time between when you press  the shutter release button and the camera actually takes the picture   Hold the housing steady a second or two after pressing the shutter  release button      Do not shoot down on subjects as they will quite often blend into the  background and be difficult to see in the photograph  Shoot subjects  straight on or shoot up at a slight angle using the blue water as a  contrasting background      When using daylight or flash  if your camera consistently over or  underexposes the image  you may want to adjust your camera   s  exposure compensation 34 settings       If you error in exposure  it is better to have the image slightly  underexposed rather than overexposed  An overexposed image is  missing color information which cannot be adjusted in a photo  processing program  A slightly underexposed image has color  information that can be adjusted      It is important to respect all living creatures underwater  including  people  marine life  and coral  While we encourage people to get close  to their subjects when taking a photograph  they should not touch  lie on   or in any way disturb the things they
4.  find underwater       Technical Support      Please read the troubleshooting section of this instruction manual before  contacting Ikelite Technical Support           Ikelite Technical Support    Email  ikelite ikelite com  Phone 317 923 4523  Fax 317 924 7988    30         Limited Warranty      This Ikelite product is warranted against any manufacturing defects for a  period of one  1  year from the original date of purchase  Defective  products should be returned to Ikelite postage paid  Ikelite will  at its sole  discretion  repair or replace such products  and will return to customer  postage paid  All other claims of any nature are not covered  Except as  mentioned above  no other warranty expressed or implied applies to this  Ikelite product             Returning Products For Service         Ikelite is most interested in performing any service to ensure that all  products perform as intended  Evidence of purchase date must be  provided to obtain warranty service    No prior authorization is required  You may return directly to us or  through your dealer  Please include a brief description of the problem   any relevant email correspondence  and or instructions on what you  want us to do  Always include name  shipping address  email address   and phone number inside of the package  Send postage paid to     Ikelite Underwater Systems  Attention  Service Department  50 West 33 Street  Indianapolis  IN 46208 USA    No reimbursements for postage paid will be issued   You may
5.  installation   f the Sync Cord does not seat properly inside the Bulkhead   the pins and receptacles are improperly aligned  repeat Step 3     4  Tighten the Knurled Nut snugly using your Index finer and thumb  DO  NOT use pliers or other tools to tighten the Knurled Nut     Always remove the Syrie Cord   Sync Cord from your Ikelite TTL Tg   Housing when not in Sync Cord Housing   gt  Bulkhead          use  and replace the C  Bulkhead Cap   Caution    Do not remove the   waterproof Bulkhead   Cap unless an external   sync cord is going to Knurled Nut   be plugged in  Do not   remove Bulkhead Cap   or Sync Cord   underwater  Bulkhead Cap       Turn Camera On  Turn the camera on and operate each of the housing controls to get a  feel for using the camera in the housing  Take a few test shots on land   You are now ready to shoot underwater photos and video   13    Preparing to Install Zoom Clamp  amp  Gear Sleeve    Determine the type  of lens being used  on the camera   Type 1 Lenses have  a lens opening that  is NOT larger in  diameter than the                                                                     i SS     zoom ring   Fig  1   Type 1 lens Type 2 lens   Figure 1   Figure 2     Type 2 Lenses have a lens  opening that IS larger in diameter than the zoom ring   Fig  2      Zoom Clamps  amp  Gear Sleeves Included with Housing       Normally used with Normally used with  There are 2 different Type 1 lens  Fig 1  Type 2 lens  Fig 2   Zoom Clamps and  5509 28 Package   
6.  seated as shown in figure 1 and not    extruded as shown in figure 2  Fig  2    Fig  1          Caution   After installing the port  turn the Zoom Control knob on the housing  If the  Zoom Control is difficult to turn  the gear sleeve may be warped  If  necessary  reduce or omit any rubber installed on the Zoom Clamp  figure    F  page 16   f the Zoom Clamp is still warped  use of the 5509 28 package  may be required  see page 14        Lens Ports    A lens port must be secured to the housing before entering the water   Ikelite DSLR housings DO NOT come with a lens port  You must select  the correct port for each lens you will be using underwater  For complete  lens port information and compatibility with your Ikelite system  go to  www ikelite com     20    Attaching an Ikelite Strobe Arm to the Housing Handle    To attach an Ikelite Arm to your Housing Handle  depress the  spring loaded Handle Push Button until it stops  Gently slide the    pronged end of the Ikelite Arm into the hole in the top of the Handle as  shown     When the Ikelite Arm is properly seated  the Handle Push Button will    return to its starting position   m Housing Handle    Handle Push  Button    Ikelite Arm                      21    Pre Dive Your System    It is recommended that you take the complete system into a swimming  pool before use in open water  This will give you a chance to become  familiar with the handling and operation of your housing and strobe s      As soon as you enter the water  
7.  strobes with the dual sync cord  the primary  strobe connected to the cord without the red band  must be turned on to  power the Conversion Circuitry  Always keep both strobes connected to  your dual sync cord underwater  Do not exchange your secondary  strobe for a dust cap which may not be waterproof     Setting the Conversion Circuitry Strobe ID Switch    On the inside of the housing back is a switch  for setting the DS Substrobe ID  Set the  switch to the Model of DS Substrobe being  used     Strobe ID Switch          When using dual strobes of different models 160 161  such as a DS51 and a DS161  set the ID 200    P Set DS Substrob   switch to DS51 or the smaller strobe  to TTL Mode    ke    ikelite    Using the Conversion Circuitry  Set Ds Substrobe to TTL mode     Mode and Compensation Dial   Note that the TTL compensation values are located in the yellow band   Manual compensation values are located in the black band  Rotate the  Dial to switch between TTL and Manual Modes    TTL Mode compensation values are indicated in the yellow band  Place  the Setting Indicator to TTL for NO Compensation  Rotate the Dial either  direction to select     compensation  Place the Setting Indicator to the  desired compensation value  Note that in TTL  compensation values are  in 1 3 f stops    Manual Mode compensation values are indicated in the black band   Rotate the Dial to place the Setting Indicator to the desired compensation  value  Note that in Manual Mode  compensation value
8. 2 24 thread with 3in spacing  76mm          Package Contents           SLR DC Housing   Aluminum Tray  amp  Dual Handles     Envelope containing tray   Silicone Lubricant  installation hardware    Standard Zoom Clamp  amp  Sleeve Set  maintenance kit  and extra    5509 28 Large Diameter Zoom  control end tips  Clamp  amp  Sleeve Set         Preparation         This product has been water pressure tested at the factory and is depth  rated to 200 ft   60m   Thoroughly inspect and immerse the empty  housing completely in water before installing a camera  If any fogging  occurs or droplets of water enter the housing  do not install a camera   Clean the housing main o ring and retest to make sure that it is  watertight  Refer to the Troubleshooting section  page 23    We suggest that you read this instruction booklet thoroughly before use  to have a full understanding of where each camera control is located   and what function each control provides  Please read your camera  manual thoroughly to have a full understanding of each camera function   If you are new to underwater photography  be sure to read the Photo  Tips section    Due to the power required to operate the camera and LCD screen start  each dive with a fully charged camera battery     Attach External    Tray with Handles    to Housing    Use hardware and instructions  located in the clear Ikelite pouch  to attach the    Tray with Handles     to your Ikelite housing              Parts of the Housing   Front View Quick R
9. 9059 8 small diameter clamp   9059 9 large diameter clamp   Gear Sleeves For use with  0073 sleeve For use with  0073 1 sleeve  provided with the E  housing  Start with    the suggested Zoom  Clamp and Gear F y    wide narrow  Sleeve depending grooved grooved  on the Type of extension   extension      lens being used       See  Fig  A or B  A thick is N    tabs tabs        0073 sleeve  Use with  0073 1 sleeve  Use with    small diameter zoom clamp large diameter zoom clamp   9059 8  9059 9  Figure A Figure B    14    Installing the Zoom Clamp  amp  Gear Sleeve On the Type 1 Lenses    The Zoom Clamp has springs so it can be expanded to fit over the  Zoom Ring of the lens   figure C  page 15    Install the Zoom Clamp with the extension tabs toward the rear element  of the lens  After installing the Zoom Clamp and Gear Sleeve   figures D   amp  E  page 16  install the Lens Port and rotate the Zoom Ring on the  lens  If the Zoom Ring and Gear Sleeve do not mesh properly  install the  rubber strips  supplied  to the inside diameter of the Zoom Clamp as  shown in figure F  page 16    Two thicknesses of rubber strips are provided  Start by installing the  thinnest rubber strips  If the Zoom Clamp still is not tight enough and  meshes improperly with the Gear Sleeve  use the thicker rubber strips   Reinstall the Zoom Clamp  Sleeve  Mesh Gear Sleeve teeth with Black  Housing Drive Gear  figure G  page 18  and then install the Lens Port   After installing the port  pages 19  amp  20  r
10. A    aperture priority    Set shutter speed to 1 60th second or 1 125th second for fast  moving subjects in    M    mode  In    A    mode shutter speed is automatically  locked at 1 60 second    Set aperture to F8 for general photography or F22 for macro  photography  close ups     Set red eye reduction and    FP    to OFF in the Menu Settings   Set image resolution to highest jpeg setting or RAW    Set ISO to 100       Set Metering to    center weighted        Opening the Housing    Lid Snaps have a Lock  To open   push Lid Snap Lock forward and lift as  shown  Keep pressure on the Lid  Snap so it does not fly open quickly     Push Forward         Lid Snap Lock    Lid Snaps have a lot of spring tension  once they go over center  so havea Lift  firm grip on the Lid Snap  Lid Snaps  may be opened one at a time     Housing Conversion Circuitry    This housing contains Ikelite designed and patented Conversion  Circuitry  Once attached  turn the strobe on first before turning on the  camera    When used with Ikelite DS Substrobes the Conversion Circuitry provides  real Nikon iTTL flash exposure with over and underexposure  compensation from  1 1 3 to   1 1 3 f stops in 1 3 stop increments    The Conversion Circuitry also offers Manual exposure control with 3 1 2  f stops of underexposure control in 1 2 stop increments    The Conversion Circuitry is powered by the Ikelite DS Substrobe when  connected to the housing with the 4103 51 single or 4103 52 dual sync  cord  When using two
11. all amount of lube on the small end of  the push button shaft at it   s base  Release and  operate the push button several times to distribute  the lube    If a control is sticky  grab the control knob  pull it  out  and then push back in  If still sticky  see the  Control Maintenance section   pages 26  amp  27   Return housing to Ikelite for routine maintenance        Image is over  or Check that the strobe s  are firing when taking  under exposed a picture    When using an external strobe  make sure it is  turned on  set properly  and it   s battery is charged   Check any corded connection points    Adjust camera shutter speed  aperture  or  exposure compensation    Move closer to or further away from the subject        Water enters the Remove  clean and properly lubricate the main  housing housing and port o rings    Look for hairs  dirt  or foreign debris crossing the  o ring seal    Reassemble the housing without a camera  installed and pressure test or take diving    Return housing to Ikelite for routine maintenance           Problem    Camera does not  take a picture    Solution    Install a fully charged battery    A housing control is engaging a camera function  and will not allow the shutter to fire    There is not enough available light for the camera  to properly focus  Add a focusing light or strobe  with a built in focusing light to your system   Select a center focus point in your camera menu        Housing is hard to  close    Make sure the camera is mounted 
12. also features five  1 4 20 threaded mounting points for attachment of a tripod or other  accessories     EV Controller Use    TTL flash control is not available when using an EV Controller  and  therefore an EV Controller is not recommended for use with this  housing    Note  The EV Controller cannot be used as a slave  If hardwired to the  housing  set the EV Controller to Non pre flash     The EV Controller used with Ikelite DS Substrobes has two user  settings  One setting is for strobe selection  the other is for pre flash    P     or non pre flash           Most cameras use a pre flash  This means the  EV Controller should be set to the pre flash    P    position when used with  this camera as a slave  If a manual mode is used that does not emit a  pre flash  set the EV controller to the non pre flash          position     25       C    Maintenance         Control Maintenance    26    Ikelite controls are designed to provide years of reliable service with  minimal maintenance    Push button controls require no maintenance other than rinsing in fresh  water after saltwater use  If a push button control becomes difficult to  push or if it sticks when depressed  soak the housing in luke warm fresh  water  After a few minutes  operate the push button  If this does not  correct the problem  return the housing to Ikelite for maintenance    Some of the controls have long shafts  These controls can be pulled out   exposing the shaft  diagram B  page 27    To lubricate the contro
13. elease                                    On Off Strobe Arm  AF  Release Buttons Flash Mode Mount   3 H  Shutter AE  L   Release arp Zoom       K                          Drive Gear                   Port    Sub    command Opening   Dial Lid                                                                             Aluminum Tray    Side View    AF  Release Buttons    Lid Snap    e  Meter  4            Optional    rr  Lock Port    AE L  AF L       9          Shutter  Release            f  Main Housing    r Oring Sub command    Dial  Camera Tray         4 Gear                a  Sleeve    c a   pS Port O ring  Leveling Screw  Factory Pre set     Camera Mounting I                               Back View                         Quick  Release  ES Button                                  Release     AF M                                                                                                            1  External Strobe Connector and  Waterproof Cap   Mode Dial   Delete     Playback       Menu   White Balance   ISO   Quality   Optical Viewfinder    O o N o oe a    10   11    2   13     14    Main Command Dial    Live View Button  Multi selector Up A  Multi Selector Left  lt q      OK Button    15   16   17   18     Multi Selector Right  gt    Multi Selector Down W  Flash Compensation Dial 34  Info Quick Settings    Initial Camera Setup    Insert a fully charged battery    Insert a SD or SDHC memory card    Set Time Zone and Date    Set the Mode dial to    M    manual or    
14. fs    ikelite  SLR DC Housing    instruction manual  6808 1 Nikon D80                               _      _ Je                                                                      Thank you for your purchase of Ikelite equipment  Please read this  instruction manual completely before attempting to operate or dive  with this product  Please refer to the back page of this manual to  register your Ikelite product                                            Table of Contents    TECE OnE P  3  Package Contents      SR ee ee P 4          Attach External    Tray with Handles    to Housing              P  4   Parts of the Housing   Front Side View              0   00e P 5   Parts of the Housing   Back View    nees P  6   Initial Camera Setup     Opening the HOUSING s2    e 20sis ance Atte  P  7   Housing Conversion Circuitry                cccceececeeeeeeeeeeeteees P  8   Setting the Conversion Circuitry Strobe ID Switch           P  8   Using the Conversion Circuitry              c cccceeeeeeeeeeeeeeees P  9   Using Non lkelite or Ikelite Non DS Substrobes              P  9   DS50 and DS125 Substrobe Compatibility        0     0    P  10  Attaching the Flash Connection for External Strobes     P  10  Attach Camera to Housing Tray               ccsccceeseeeeeetteees P  11  Installing Camera in HOUSING                 cceeeeeeeeteeeeeeteeees P  11  Closing    the  HOUSING inensis aaa P  12  Final CHECK  seeisccvsccsevcetvcracssccvserssctesteserss yaaa P  12  Attaching a Sync Cord to t
15. g into  allen wrench required   gland  Diagram B    Lubricate Shaft    Housing           Pull out to  expose shaft    27    Housing Maintenance    Your Ikelite Housing should be given the same care and attention as  your other photographic equipment  In addition to normal maintenance   we recommend your housing be returned to Ikelite  every 2 3 years or  50 dives   to be checked and pressure tested    Do Not leave the camera and housing in direct sunlight for prolonged  periods  Heat may damage the camera    Do Not ship the camera in the housing    Before using the housing  always check the tightness of the set screw  in each control knob    Check each control gland penetrating the housing to make sure they  are tight  There is a slight chance that either could vibrate loose during  travel    Keep the back and port o ring clean and lightly lubricated  To lubricate   remove the o ring from the back  Put a small amount of Ikelite lubricant  on your fingers  Pull the o ring through your fingers to apply a light  coating of lubricant  Only apply enough lubricant to make the o ring feel  slick  Do Not stretch the o ring  This light coating of lubricant will help  to keep the o ring from drying out and will help to show a dark sealing  line when the housing back is properly sealed    Keep the area where the o ring fits and the sealing surface clean    Rinse the housing exterior thoroughly in freshwater after each saltwater  use  Depress push buttons several times during rinse  Dry 
16. he Housing                 ccee P  13  PUP Camera OM vevscces seacecevecvecttecescoxsereysctsceresacaeseatvieysces P  13  Zoom Clamp  amp  Gear Sleeve Installation           0     8 P  14  Manual FOCUSING  cernere E eTA P  18  Installing the POTT asisisennoniasissaaa P  19  Lens POMS  srren AT EE EEEE P  20    Attaching an Ikelite Strobe Arm to the Housing Handle  P  21    Table of Contents   continued    EA AEA A AE E aeedisa cts P  22                Pre Dive Your SySteM sismos usdi iaaa P  22  Lubricants                   en een eer E P  23   Recommended Accessories  0 0 00    P  25  Accessory Mounting Points ssassn P  25  EV Controll  r US  tstsc eeecntien ceed P  25  ay P  26  Storing ihe  HOUSING  bsccescge tanec P  29    ba dennis iene as E E P  29  feu eats E E P  29  E P  30  E P  31                    Returning Products for Service  EEEE TO EAT P  31    Product Registration  aeaiia ae aa a ER RN Ra Back Cover     Specifications     CONOIS cicis All important camera functions are accessible  Controls  not provided for Diopter Adjustment and Flash Button    Widths aessa 10in  250mm  including controls   Height           0 7 0in  178mm  including controls   DO Pts sisevsecserse venus 6 5in  165mm  including controls   Weight               000 5 5Ib  2595g  without tray  amp  handles   Buoyancy    s    Neutral in freshwater  Dependent on lens  amp  port   Built in Flash            No   Strobe Connection    kelite digital TTL electrical bulkhead   Tray Mounting          1
17. inued  Before installing the lens port and checking operation  make sure the  teeth on the Gear Sleeve mesh with the teeth on the housing Drive Gear   shown below  When the port is installed  pages 19  amp  20  it will lock the  Gear Sleeve in place  After installing the port  rotate the housing Zoom  Control Knob to see that the Gear Sleeve is properly rotating the Lens  Zoom ring     Manual Focusing    Ikelite DSLR housings are designed for auto focus DSLR cameras and  lenses  Manual focusing is not recommended  In some cases  if you  desire to manually focus a lens  the zoom clamp must be moved onto  the lens Manual Focus Ring and you must use the housing zoom control  knob to manually focus  This will result in loss of zoom capability     IKELITE        Figure G    Port Lock   gt  Release  R Button    Mesh   Gear Sleeve  teeth with  Black  Housing  Drive Gear    18    Installing the Port LD re  fe  OC   There are four port locks on the an E  Release           utton    front of the housing  see figure  G  page 18  Each port lock has  a Release Button  Lift the Locked Position  release button and slide each        Lift Release  Port Lock away from the port Ze  Button to  f E Unlock  opening  In the unlocked  position  the Release Button will  remain in the up position as  Pull Back to  shown   2 Disengage  Port    To prepare the port for   installation  remove the port o ring and lightly lubricate it  The port seal  is a side to side seal and requires the o ring to be light
18. l  gently pull on the knob until the stainless steel  shaft is exposed  Lightly lubricate the shaft  then move the shaft in and  out several times  This will lubricate the x ring in the Ikelite control gland   This should be done before using the housing after a prolonged storage  period  or once a week when the housing is in constant use    Some of the controls have a short shaft and cannot be pulled out  exposing the shaft for lubrication  In the unlikely event one of these  controls sticks or becomes difficult to operate you can remove the  control from the housing and lubricate it  or return the housing to Ikelite  for maintenance  To remove the control  diagram A  page 27  loosen the  set screw in the knob  allen wrench required   remove the knob  If there  is salt or dirt build up on the exposed control shaft  clean the shaft   Open the housing and gently slide the control shaft out of the control  gland  Clean and lightly lubricate the shaft  including the end of the  shaft  Slide the shaft back into the control gland and gently slide it back  and forth a few times without fully removing the shaft from the gland   Replace the knob noting the flat area on the shaft  The set screw in the  knob should tighten down against the flat area on the control  so the  knob does not turn on the shaft     Diagram A          Housing  Gland  Control Shaft  Tighten set screw down  against this flat area Lubricate end of shaft Loosen set screw  when replacing the knob  before reinsertin
19. ly lubricated for  easy installation  Put a small amount of lubricant on your fingers and pull  the o ring through your fingers to lightly lubricate it  Do not stretch the  o ring  Check that the lip of the port where the o ring fits and the sealing  surface on the housing are clean  Place the port  with o ring  into the  housing port opening  Press down on the port firmly and evenly until you  feel the port slide into place  Continue to push down on the port and  push each port lock forward until the lock fully engages  It may help to  slightly rotate the port as you push in on the port lock  Visually inspect  each port lock and confirm that the Port Lock Release Button is seated  flush against the Port Lock Body  Do not rely on an audible  click  to  indicate that the lock is engaged    Check around the perimeter of the port seal to see that the o ring is  properly sealed and not extruded  figure 2  page 20    It is NOT necessary to tighten housing port locks after installing a port   Port locks are factory adjusted  Slight port movement is normal after port  locks have been closed and port has been secured to the housing     19    Installing the Port   continued    To Remove Port    To remove the port  lift up on each Release Button and slide the port  lock away from the port     Port Seal Inside View    If the port is installed before the camera is  inserted into the housing  look from the  inside of the housing at the port seal   Check to see that the o ring is properly 
20. otate the housing Zoom Control  Knob to see that the Gear Sleeve is properly rotating the lens Zoom ring     Type 1 lens  mounted  to camera                            Figure C    15    Type 1 Lenses   continued        Gear Sleeve Ribs    Align Ribs with  Zoom Clamp  grooved tabs                                         FE        apply     rubber strips    to inside of      i j me  gt     Figure E                            Figure F  16    Installing the Zoom Clamp  amp  Gear Sleeve On Type 2 Lenses    Due to the larger diameter lens opening on Type 2 lenses  the Zoom  Clamp and Gear Sleeve need to be installed from the rear  bayonet end   of the lens  Use the housing Lens Release Control and remove the  camera lens from the camera body  after the camera and lens have  been installed in the housing    Place the Gear Sleeve in the housing opening as shown    Install the black Zoom Clamp on the Lens Zoom Ring and lower the lens  into the housing opening  Make sure the Zoom Clamp grooved tabs  align with the Gear Sleeve ribs  If necessary  install rubber strips to  expand the Zoom Clamp so it meshes properly with the Gear Sleeve   Bayonet lens into camera body and align Gear Sleeve teeth with Black  Housing Gear Teeth  Type 2 lens    Lens Zoom Ring    Lens Manual  Focus Ring       Zoom Clamp          Align   Zoom Clamp  grooved  tabs with  Gear Sleeve  Ribs       Gear Sleeve       TOP OF HOUSING                            17    Installing Zoom Clamp Sleeve on Type 2 Lenses   cont
21. ouch the housing all the    way around  There should y   o ring  be an even gap all the way around  between the housing and the housing housing      back    4  Lift the lid snaps so they are extended  and place the lid snap into the eiehusee  corresponding hook on the housing all    sides housing back    back       5  To close the housing  push down on the      lid snaps until they snap into place  Lid     snaps on opposite sides of i    the housing should be closed    at the same time  Be sure they  are down far enough to engage  the lid snap lock                 housing                 Final Check  Once the housing is closed  check the o ring seal  Check the gap  between the housing back and the housing  It should be even all the  way around the housing   Look through the clear plastic back at the o ring  You should see a  darkened area where the o ring is compressed against the housing  back  If you do not see an even black compression seal all the way  around the back  open the lid snaps  reseat the housing back and close  the lid snaps  Visually check the seal again     12    Attaching a Sync Cord to the Housing    The Housing Bulkhead is designed to accept only an Ikelite 5 pin TTL  Sync Cord    1  Lightly lubricate the Sync Cord O ring  Use ONLY Ikelite lubricant   supplied with housing     2  Remove Bulkhead Cap from Housing Bulkhead    3  Line up the Sync Cord Pins with the corresponding Bulkhead  receptacles  Gently insert Sync Cord into Bulkhead  DO NOT force this 
22. properly on the  camera tray and housing controls are out of the  way         Fogging occurs on  the Lens Port    Humid air is trapped inside the housing    The camera produces heat and may condense  any trapped moisture forming fog on the lens port   Close the housing in an air conditioned room or  vehicle  or in front of an air conditioner    The housing should not be in direct sunlight for an  extended period of time    Purchase desiccant packs from a local camera  store and place one or two packs in your housing  before each day of diving    If water droplets or moisture is present around the  controls or sealing areas  return the housing to  Ikelite for evaluation    Clean the main housing o ring  port o ring  and  sealing surfaces of the housing        Pictures are too blue  or too green       Use custom  manual  white balance if available   Add an external strobe    Move in closer to your subject when taking a  picture           C Recommended Accessories 3       A full range of accessories are available to support your housing  Please visit  www ikelite com to see the most current information about recommended  accessories for your housing     Accessory Mounting Points    The top of the SLR DC housing features a 1 4 20 threaded mounting  point for the attachment of a focus light  video light or other lightweight  accessories  DO NOT attach heavy items to this mount and always use  the correct length screw to attach a component     The bottom of the SLR DC housing tray 
23. s are in 1 2 f stops  from  F  full power to  3 f stops    Set DS Substrobe to TTL mode  This will allow the strobe power to  be varied in manual mode     Mode and Compensation Dial        TTL Flash Scale  yellow   1 3 stops     Setting Indicator       Manual Flash Scale  black   1 2 stops     Using Non lIkelite or Ikelite Non DS Substrobes   Substrobe 50  100A  200  400  with this Housing    The Conversion Circuitry is automatically disabled when used with a  Non Ikelite or Non DS Substrobe  These Substrobes can be used in their  manual mode utilizing any power settings provided on the Substrobe     9    DS50 and DS125 Substrobe Compatibility    Older DS50 Substrobes with Serial Number below 63 850 can NOT be  updated to operate correctly with the latest TTL conversion circuitry   Older DS50 Substrobes with Serial Number between 63 850 and 69 999  require upgrade of electronics to operate  Cost of update depends on  strobe circuitry  Strobe must be returned to Ikelite for evaluation to  provide an estimate of upgrade cost    Older DS125 Substrobes with Serial Number below 2 500 can NOT be  updated to operate correctly with the latest TTL conversion circuitry   Older DS125 SubStrobes with Serial Number between 2 500 and 4 999  require upgrade of electronics to operate  Cost of update depends on  strobe circuitry  Strobe must be returned to Ikelite for evaluation to  provide an estimate of upgrade cost     Attaching the Flash Connection for External Strobes    10    When using
24. take a moment and check the housing  to see that it is properly sealed  Next  check to see if there are any  bubbles on the face of the port  If there are  take your fingers and  remove them  If there are bubbles on the lens port they can produce soft  focus spots in your photographs     Lubricants    Ikelite provides silicone lubricant with the housing  We recommend that  you use only Ikelite lubricant  Other brands may cause the o ring to  swell and not seal properly    Use only enough Ikelite lubricant to lightly cover control shafts and  o rings  Wipe off any excess lubricant with a clean cloth  Lubricant is not  a sealant and is used to reduce friction  Excessive lubricant can collect  sand and dirt which may interfere with proper sealing     Note  Lubricant is not needed on the main housing o ring to maintain a  housing seal  however  lightly lubricating this o ring can extend it   s life  and aid in seeing a good housing seal  Too much lube can attract debris  increasing the potential for a leak     CAUTION  Never use spray lubricants as the propellant ingredient  can cause the plastic housing to crack  Use ONLY Ikelite lubricant     22         Troubleshooting _      Problem Solution       Push buttons or Remove the camera and rinse the closed housing  controls are sticky in fresh water  Vigorously press each push button  and hard to operate in and out several times to release any trapped  saltwater or debris    Press a sticky push button all the way in and  place a sm
25. with a soft  cloth  Dry port to eliminate water spotting    After several uses in saltwater  soak the housing in a mild soap solution   rinse  and dry    Although not recommended  if it is necessary to remove a housing push  button  Do Not re use the E clip  Contact Ikelite for replacement E clips   part  0319 12      CAUTION  Never use spray lubricants as the propellant ingredient can    28    cause the plastic housing to crack  Use only Ikelite lubricant     Storing the Housing    When the housing is going to be stored for a prolonged period it should  be soaked in a mild soap solution  rinsed  and dried thoroughly  Remove  the back and port from the housing  Remove the back and port o rings   lightly lubricate them and place them in a plastic ziploc bag  Place the  plastic bag inside the housing for storage  Operate the push buttons  periodically          Spare Parts      0132 59 25 0 0 Spare Main Housing O ring  AAT  Spare Port to Housing O ring       PRANTE Silicone Lubricant in 4 1cc Tubes     O ring Kit with Main O ring  Port O ring   amp  1  c Lubricant  PEET Tray Mounting Screw 12 24 x 1 2 in  Stainless  Konpare 1 4 in  Shoulder Washer for 12 24 Screw  TET Waterproof Bulkhead Cap       Munkena Body Cap         Photo Tips           The number one rule in underwater photography is to eliminate as much  water between the camera and subject as possible  Get as close as you  can to the subject  then use the zoom  If you are using flash for still  photos  subjects beyond 6
    
Download Pdf Manuals
 
 
    
Related Search
 Instructions  instructions synonym  instructions not included movie  instructions for 1040 2024  instructions in spanish translation  instructions for form 8962  instructions brp  instructions meaning  instructions for 1040  instructions unclear meme  instructions for form 941  instructions for schedule c  instructions for form 720  instructions for form ss-4  instructions for 1040 2023  instructions for form 1040  instructions for submitting certain i-589  instructions in writing adr  instructions synonyme  instructions to candidates 
    