Home

SunSetTM T1 - Advanced Test Equipment Rentals

image

Contents

1. a step ahead SunSet T1 SPECIFICATIONS Connectors Bantam jacks Eq Tx Eq Rx Fac Tx Fac Rx 8 pin mini DIN RS232C serial port DTE Access Single Mode DSX Monitor 100Q Bridged Monitor gt 1000Q Terminated 100Q Terminated Loop 100Q Bridged Loop gt 1000Q DSX Monitor Loop 100Q Dual Mode Thru A B Split A B Split E F Loop E F Mon E F Termination Thru Split Loop 100Q Mon gt 10000 Transmitter Framing SF D4 ESF SLC 96 T1DM Coding AMI B8ZS Line Build Out LBO 0 7 5 15 dB DSX pre equalization O to 655 ft 133 ft per step Clock Internal 1 544 MHz 5 ppm looped external Pulse shape to Telcordia TR TSY 000499 reference G 703 CB113 CB119 CB132 CB143 PUB62508 PUB62411 Transmit Patterns Repeating 3 in 24 1 in 8 1 7 all 1s 1 in 16 55 octet alt 1010 all Os T1 T6 DDS1 DDS6 User programmable pattern 1 to 2048 bits Store up to 10 programmable patterns with alphanu meric names Pseudo random ORS PRBS n 6 7 9 11 15 20 23 Test pattern inversion Insert errors BPV logic frame errors programmable error burst 1 to 9999 counts or error rate 2 x 10 to 1x 10 Receiver Input sensitivity Terminate Bridge 6 to 36 dB cable loss DSXMON 15 to 30 dB resistive Coding AMI B8ZS Auto Framing SF ESF SLC 96 T1DM auto frame Frequency range 1542 kHz to 1546 kHz Auto pattern synchronization Received pattern sync independent of transmitted pattern Pro
2. CSU NI replacement emulation Responds to loopback commands inband and datalink Graphic indication of incoming signal status in both directions Simultaneous display of T1 line measurements Automatic generation of AIS Loopbacks Facility Line and payload loopback Equipment Line loopback Simultaneous loopbacks in both directions Local and remote loopback control Remote Control SW100 VT100 emulation with same graphical interface used by test set Circuit status table provides current amp historical information on test set LEDs Uses test set s serial port at 9600 baud 8 pin MINI DIN Serial port can not be connected to printer during remote control Westell PM NIU and MSS SW120 Supports Westell performance monitoring network interface unit and maintenance switch system with ramp Set query NIU time and date Query performance data by hour or all Reset performance registers Read data over ramp line Perform maintenance switch function for Westell and Teltrend Pulse Mask Analysis SW130 Scan Period 800 ns Measurements Pass Fail ns Rise time ns fall time ns pulse width overshoot Youndershoot Resolution 1 ns or 1 as applicable Masks ANSI 11 102 11 403 AT amp T CB119 Pub 62411 Pulse Mask Display Test set screen and SS118 printer DDS Basic Package SW170 Choose receive and transmit time slots independently Test rates 2 4 4 8 9 6 19 2 56 64 kbps Patterns 2047 511 127 63 all 1s all Os DDS 1
3. CSU NIU emula tion ESF SLC 96 data link control CLEI TITUWO2HAA CPR 674486 SW100 Remote Control Graphical menu driven VT100 emulation Includes SS115 amp SS122 SW105 Fractional T1 Purchased with SW1000 only SW106 CSU NIU Emulation Purchased with SW1000 only SW107 ESF amp SLC 96 Data Link Send and Receive Purchased with SW1000 only SW111 VF Level Frequency amp Noise Measurement SW120 Westell Maintenance Switch PM NIU RAMP Purchased with SW1010 only SW130 Pulse Mask Analysis SW141 MF DTMF DP Dialing Decoding and Analysis SW144 Teleos Northern Switched 56 tests SW170 Basic DDS Package Accessories SS101 Carrying Case SS104 Cigarette Lighter Battery Charger SS105 Repeater Extender SS106 Single Bantam to Single Bantam Cable 6 SS107 Dual Bantam to Dual Bantam Cable 6 SS108 Single Bantam to Single 310 Cable 6 SS109 Single Bantam to Probe Clip Cable 6 SS110 SS111 SS112 SS113A SS113B SS114 SS115 SS115B SS116 SS117A SS118B SS118C SS121A SS121B SS121C SS122 SS122A SS123A SS125 SS130A SS130B SS132 Dual Bantam to 15 pin D Connector Cable Male 6 Dual Bantam to 15 pin D Connector Cable Female 6 Dual Bantam to 8 position Modular Plug Cable 6 AC Battery Charger 120VAC AC Battery Charger 110VAC SunSet T1 User s Manual DIN 8 to RS232C Printer Cable DIN 8 to DB 9 Printer Cable Instrument Stand Printer Paper 5 rolls for SS118B C High Capacity Thermal P
4. high low frequencies high low levels twist tone period interdigital time DP decode up to 40 digits Analyze number break PPS interdigital time Signaling Analysis Live Graphical display of A B C D signaling state changes Trigger Programmable A B C D trigger state to start analysis on the opposite side MFR1 Timing analysis of signaling transition states and decoding of dialed digits MFR1M Modified MFR1 CO switches signaling analysis MIXTONE Decode a signaling sequence that has both MF and DTMF digits Fractional T1 SW105 SW1010 Error measurements channel configuration verification Nx64 kbps Nx56 kbps N 1 to 24 Sequential alternating or random channels Auto scan and auto configure to any FT1 order Scan for active channels Rx and Tx do not need to be same channels Hitless drop and insert Programmable idle channel A B C D bits Selectable idle channel code 7F or FF hex ESF Facility Data Link SW107 SW1010 Read and Send T1 403 message on FDL PRM and BOM Automatic HDLC protocol handling YEL ALM LLB ACT LLB DEA PLB ACT PLB DEA AT amp T 54016 24 hr performance report retrieval 71 403 24 hour PRM collection per 15 min interval SLC 96 Data Link SW107 SW1010 Send and receive message WP1 WP1B NOTE formats Alarms switch to protect far end loop To Telcordia TR TSY 000008 specifications SLC 96 FEND loop CSU NI Emulation SW106 SW1010 Bidirectional Equipment and Facility Directions
5. DDS 2 DDS 3 DDS 4 DDS 5 DDS 6 8 bit user Loopbacks Latching interleaved CSU DSU OCU DSO DP 8 bit user Measurements Bit errors Bit error rate Control code send receive Abnormal mux out of sync idle Access Mode Loopback tests require intrusive access to T1 Teleos amp Switched 56 Tests SW1 44 Switched 56 call set up Supervision and dialing Send test patterns 2047 511 127 63 all 1s all Os FOX DDS1 6 USER Bit error bit error rate measurement Teleos signaling sequence timing analysis and dial digits decoding GENERAL Operating temperature 0 C to 50 C Operating humidity 5 to 90 noncondensing Storage temperature 20 C to 70 C Size 2 4 max x 4 2 max x 10 5 Weight 2 7 lb 1 2 kg Battery operation time 2 5 hr nominal AC operation 110V 120V 60 Hz or 220V 240V 50 60 Hz ORDERING INFORMATION Test Set SS100 SunSet T1 Chassis Includes battery charger User s manual Instrument stand Software cartridge must be ordered separately CLEI TITUWO4HAA CPR 674488 Software Options SW1000 Software T1 Includes basic measurements loopback control test patterns send rcv bridge tap propagation delay quick test Also includes VF channel capabilities Talk listen view control A B C D DTMF dialing send 5 tones at 2 levels CLEI T1TUW01HAA CPR 674485 SW1010 Software FT1 Includes all Software T1 features and adds Fractional T1 Teltrend Westell looping device control
6. and percent BPV SES count and percent BPV AS count and percent BPV UAS count and percent BPV degraded minutes count and percent Path Frame Measurements Frame bit error count and rate current and average frame slip count OOF second count COFA count frame synch loss seconds yellow alarm second count frame error second count and percent frame severely errored second count and rate frame available second count and percent frame unavailable second count and percent Path CRC 6 Measurements CRC 6 block error count and rate current and average CRC 6 errored second count and percent CRC 6 severely errored second count and percent CRC 6 available second count and percent CRC 6 unavailable second count and percent Frequency Measurements Moving bar graph of slip rate received signal frequency max frequency min frequency clock slips frame slips max positive wander max negative wander Other Measurements View Received Data View T1 data in binary hex ASCII Shows data in bytes by time slot Shows 8 time slots per display page Captures 256 consecutive time slots as test pattern Propagation Delay Measure round trip propagation delay in unit intervals 1 UI with translation to microseconds and one way distance over cable Quick Test land Il 2 programmable automated loopback tests that save time when performing standardized acceptance tests Bridge Tap Automated transmission and measurement of 21 different patte
7. grammable loss of frame criteria error averaging interval April 2001 Basic Measurements Summary Measurements Elapsed time remaining time framing line coding transmitted pattern received pattern BPV count and rate bit error count and rate framing bit error count pulse level dB CRC 6 block error count line frequency errored second count and percent severely errored second count and percent error free second percent available second percent unavailable second count and percent Logical Error Measurements Bit error count and current rate average bit error rate since start bit slips bit errored seconds and percent severely bit errored seconds and percent available seconds and percent unavailable seconds and percent degraded minutes count and percent loss of sync seconds count and percent Signal Measurements Signal available seconds count and percent loss of signal seconds count and percent low density seconds count excess Os seconds count AIS seconds count signal unavailable seconds percent Simplex current 1 to 150 mA 1 mA 5 Receive bit rate 1542 to 1546 kbps 1 bps clock source accuracy external or internal clock Receive level volts and dBdsx Peak to peak 60 mV to 15V 10 mV 5 Positive pulse 30 mV to 7 5V 10 mV 5 Negative pulse 30 mV to 7 5V 10 mV 5 SunSet T1 Line Error Measurements BPV count and rate current and average BPV error seconds count
8. rinter with 110 VAC charger Includes SS115B High Capacity Thermal Printer with 220 VAC charger Includes SS115B SunSet AC Charger 230VAC 50 60 Cycle European style connector SunSet AC Charger 220VAC 50 60 Cycle 3 prong IEC connector SunSet AC Charger 240VAC 50 60 Cycle 3 prong IEC connector Null Modem Adapter DB 25 Null Modem Adapter DB 9 SunSet Jacket SunSet T1 Training Tape English Removable SunSet Rack Mount 19 23 Permanent SunSet Rack Mount 19 23 Two Single Bantams to 4 position Modular Plug Cable FC CE Note Specifications subject to change without notice 2001 Sunrise Telecom Incorporated All rights reserved Printed in USA ZA s 3 go 3 a 7 D 3001 P
9. rns to identify possible bridge taps at some point on line Loopbacks Loopback Control In band CSU NIU 100000 10 programmable user patterns 1 to 32 bits Loopback Control ESF Facility Data Link Payload Line Network 10 programmable user patterns 1 to 32 bits Westell amp Teltrend Looping Devices Control SW1010 Automated looping of Westell and Teltrend line and central office repeaters Includes SF and ESF modes arm loop up down loopback query sequential loopback power loop query span power down up unblocking Voice Frequency Capability Monitor speaker with volume control Built in microphone for talk View all 24 channel A B C D bits Control A B C D bits E amp M ground loop start FXO FXS on off hook wink Generator 404 1004 1804 2713 2804 Hz 0 dBm and 13 dBm DTMF dialing 32 digits 10 sets preprogrammable speed dial number Programmable tone and interdigital period Companding law u Law Hitless drop and insert Programmable idle channel A B C D bits Selectable idle channel code 7F or FF hex VF Level Freq amp Noise Measurement SW111 Generator 50 to 3950 Hz 1 Hz step 3 to 60 dBm 1 dBm step Level Freq measurements 50 to 3950 Hz 3 dBm to 60 dBm Noise 3 kHz flat C message C notch S N MF DTMF DP Dialing Decoding and Analysis SW1 41 MF DTMF DP dialing Programmable DP break and interdigital period 10 pps MF DTMF decode up to 40 received digits Analyze number