OFA-CCS/CCD Series 1U/2U-Shelf Network Managed Optical
Contents
1. currentAlarmOID now OID of generated alarm 32 DKT A S Fanoevej 6 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 currentAlarmAlarmSate Alarm state of generated alarm currnetAlarmAlarmValue Alarm value of generated alarm 5 2 4 discretePropertyEntry discretePropertyEntry OID 1 3 6 1 4 1 5591 1 1 3 1 Name OID Type Access E T C discreteParameterOID 1 3 6 1 4 1 5591 1 1 3 1 1 x object identifier RO discreteAlarmValue 1 3 6 1 4 1 5591 1 1 3 1 2 x Integer32 RO discreteAlarmEnable 1 3 6 1 4 1 5591 1 1 3 1 3 x Integer32 RO discreteAlarmS tate 1 3 6 1 4 1 5591 1 1 3 1 4 x Integer32 RO discreteParameterOID discrete alarm parameter OID discreteAlarmValue discrete alarm value discreteAlarmEnable discrete alarm enable discreteAlarmState discrete alarm status x Discrete Alarm Index 1 3 5 2 5 alarmsIdent alarmsIdent OID 1 3 6 1 4 1 5591 1 2 Name OID Type Access alarmLogNumberOfEntry 1 3 6 1 4 1 5591 1 2 1 0 Integer32 RO alarmLogLastIndex 1 3 6 1 4 1 5591 1 2 2 0 Integer32 RO alarmLogIndex 1 3 6 1 4 1 5591 1 2 3 1 1 x Integer32 RO alarmLogInformation 1 3 6 1 4 1 5591 1 2 3 1 2 x Octets RO alarmLogText 1 3 6 1 4 1 5591 1 2 4
2. Table 2 Laser On OFF Key Switch Conditions Performance ON Operate EDFA normally OFF Forcefully turn off the EDFA output power W Control Switch Table 3 Control Switch Switch Performance MENU Enter the menu or move the previous menu ENTER Apply the current menu UP DOWN Move the menu items Mm LED state on the front panel Table 4 LED State DKT A S Fanoevej 6 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 Condition Color Performance Green Pump Lasers On Laser Red Pump Lasers Off Green Normal Operation No Alarm Status Red LOS Alarm LOP Alarm Yellow Bias Temp Case Temp Power FAN Alarm Comm Blue Ethernet Link On W Optical Connection Port on the front panel Table 5 Optical Connection Port Port Performance Input Optical Input Port for Launching Input Signal Outl 4 Optical Output Port for Amplified Signal WB Communication Port on the front panel Table 6 Communication Terminal Port Port Performance Ethernet Ethernet Communication Port for SNMP Monitor and Control RS 232C Serial Communication Port for RS 232C Monitor and Control 3 22 LED State Information W LOS Loss of Signal Alarm Wh
3. s Manual Rev 1 3 OFA CCS CCD Series June 2014 DC input voltage range 36 76V for DC 48V AC input voltage range 100 240 VAC 50 60 Hz DC Power supply When you connect DC power supply handle it very carefully Make sure you connect the positive and negative connections properly positive supply to the positive input and negative supply to the negative input If damage is caused by the user due to improper connections and the product does not work properly or malfunctions The manufacturer is not liable for repairs or replacement of the unit After connecting the DC power cord to the unit turn on the power switch on the rear panel If LCD on the front panel turns on the system electric power supply is normal OK DC connector dimensions Below are the specifications on the DC connectors eFORK TYPE Material Electrolytic Copper Surface Tin plated Insulation Polyvinyl Chloride Stud Dimension mm COE ss LS p TE qoe rs do n9 226 125 3 33 eRING TYPE Material Electrolytic Copper Surface Tin plated Insulation Polyvinyl Chloride awe oe Te lee AE AE SES 226 125 3 163 ao 42 100 50 065 AC Power Supply There is a fuse in the AC power socket After connecting the AC power cord to the unit turn on the power switch on the rear panel If LCD on the front panel turns on the system electric power supply is normal OK If LCD does not come on you n
4. 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 If you push the Enter switch the time value is stored 42 7 IP Address The IP Address menu is showed IP Address of network T DKT A S Fanoevej 6 20 DK 4060 Kirke Saaby TIF 45 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 5 INTERFACE 5 1 Command Line Interface CLI User can monitor or control EDFA through Ethernet port or COM port ADMIN and USER accounts are established separately for different access priorities ADMIN account holder can set passwords for both ADMIN and USER accounts In addition the task of administrative work such as network connection monitor and control of EDFA are to be performed under ADMIN account USER account holder usually equipment operator is allowed to monitor EDFA s current status 5 11 Commands Information on how to set arguments of each Command is provided after a Command followed by Enter key Show available Commands in CLI with description for user s reference ver Display basic hardware information on EDFA cls Clear the console screen ping Check connection of equipment to which an IP address is assigned logout Log out from ADMIN or USER account Not available for Telnet connec
5. Parameter The parameter page provides a view similar to the screen shot below The Input Power and Output Power alarm threshold values are displayed and can be modified Other elements are read only Users should exercise caution in adjusting the threshold values away from the default as they are critical for proper optical amplifier operation Only the ADMIN account user can access this page Optical Aerpkher monn c p p A n2g9t Po yyy grfq9g55 muss il Parameter EDFA Alarm threshold Monitoring Parameter input Power Output Power Control set tow high Tm be digh stt Event Log dem 12 0 1 0 dan sum oo 2 0 v dim IP Login set wang 11 5 1 0 06 dam wamlng 0 0 10 dim SNMP set Laser Current Laser Temperature Manwal be high bow high alarm Ld alarm t wma i ma wang oc t Laser Curtent Laser Temperature be high bw high PT LJ aam t worming mA warning 4 x Laser Correct Laser Temperature tow high tm high sum mA am t waming mA warning t Laser Curreet Laser Temperature ow high uw high alarm i me alarm t warming 4 mA wameg c 4 Laser Current Laser Temperature bw high bw high alarm mA alarm warming ma warning x Laser Correes Laser Temperature kw high bw high aam 17 mA alam x DKT A S Fanoevej 6 39 DK 4060 Kirke Saaby TIf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series J
6. The LOP alarm turns off when the output optical power of the EDFA is normal and the color of status LED changes red to green W BIAS Alarm The Pump Laser Diode provides pumping energy to the Erbium Doped Fiber in the EDFA The pumping power of the Pump Laser Diode is controlled by applying a bias current If the bias current of the pump laser diode is loaded above 95 of the end of life EOL value the pump bias current alarm is activated The EOL bias current is defined as 120 of the beginning of life BOL bias current The pump laser diode driver is limited to never exceed the EOL bias level This is an indicating LED for an over current condition of the Pump Laser Diode bias current If the BIAS alarm is activated the color of status LED changes green to yellow E TEMP Alarm The internal temperature of the Pump Laser Diode must be kept the operating range If the internal temperature of the Pump Laser Diode goes outside of the operational range the TEMP alarm is activated If the TEMP alarm signal is activated the color of status LED changes green to yellow Mm POWER Alarm The voltage of power supply must be kept the operating range If the voltage of power supply goes outside of the operational range the POWER alarm is activated If the POWER alarm signal is activated the color of status LED changes green to yellow W FAN Alarm The fans must be kept the operating If the fans are not operated the FAN alarm is activated
7. nel e eet orte teres oe EN Re Eg Figure 4 Shelf Type EDFA Measuring Instrument Setup Table Contents Table 1 The Inventory of Shelf Type EDFA Table 2 Laser On OFF Key Switch Table 3 Control Switch Table 4 LED State Table 5 Optical Connection Port Table 6 Communication Terminal Port ees ese ee ee ee ee ee ee ee ee ee ee e enne hn ee ee ee ennt nnne Table 7 Provision Menu Description ee Table 8 Alarm Descriptions Table 9 The Instrument for measuring the performance esse esse ee ee ee ee rennen 45 Table 10 In the cases alarm events and Alarm LEDS signs 0 0 0 ieee nennen 47 DKT A S Fanoevej 6 4 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 1 INTRODUCTION 1 1 About this Manual This manual consists of six sections They are Introduction of the Shelf Type EDFA System Requirements Installation Operation Testing and Trouble Shooting A brief chapter outline of this manual is below Chapter 1 The introduction of the Shelf Type EDFA and safety cautions for proper installation Chapter 2 How to install the Shelf Type EDFA Chapter 3 Panel description Chapter 4 Utilizing the LCD and Menu switch operation Chapter 5 Interface Chapter 6 EDFA Performance check
8. GEN Eg be de sk ee 9 3 2 Panel Description esse sees sesse se ese See ee Se EG Be Ee GEE Ee Be EG 9 32 1 Front Panel 1 Re Re GR GRA GRA GRA Gee Ge ee Ge ee ee Re GE Re GR Re GR Re GR Re GRA Re Gee ee 9 322 LED State Information sess 10 3 2 3 Rear Panel ee ee ee Re GR RR RR RA RA GRA GRA Gee Ge ee ee ee ee Re ee Re ee Re ee ee 11 4 OPERATION ie se ke EG RE OS EN Ge EN GE N ek Ad Ee KAN Ge ed Go ed ke De 12 AV SUMMALY EE EE EE N EE ON EN 12 4 2 LCD Operation sesse ese se ese se ee A EG Be EE Ee E Bee Ge See esso seta ee ee 13 4 2 1 Menu Selects iese ee ee ee Re Re ER RR RA GRA GRA GRA Gee Ge ee ee ee ee ee Re ee Re enne 13 42 2 Provision MENU ee ee ee Re GR RR RR RA GRA GRA GRA Gee Ge ee ee ee ee Re ee nennen 14 WER OG ARE OR EE EE EE OE N 15 WER OE 16 N RE EE EE EE 19 4 2 6 Function Setting ee ES DERE tes ett Re eee D rere op ED el ese 19 4 2 7 IG ER N N EE N NE N EN ES 20 5 DIN TE BACB EE EE 21 5 1 Command Line Interface CLI users sesse sesse oge ER Re VSA GE DERS GE de EERS GEE GE EER eGGSA GE GEGEE N ee 21 SLI Commands EE OR EE eerie 21 5 1 2 Network ConfiguratiON iese ee se ee RR RA GRA GR GR Ge ee ee ee Re Re RR RR ee ee 31 5 1 3 SNMP Configu ratlon nece niii irte cid ert o et GN ees Re ERG erani 31 52 SNMP TIME Se EG Se ee ae 32 5 2 1
9. Power is displayed the EDFA output power of several ports The LD Bias Current is the bias current of the pump laser diode The unit of LD Bias Current is mA The x of LDx is the number of used laser diode The LD Thermistor is the pump laser diode temperature The unit is centigrade C N Tlf Fax E mail Web DKT A S Fanoevej 6 DK 4060 Kirke Saaby 45 4646 2626 45 4646 2625 mail dktcomega com www dktcomega com Network Managed Optical Amplifier OFA CCS CCD Series User s Manual Rev 1 3 June 2014 The Temperature is the EDFA module temperature The unit is centigrade C Using the Alarm menu you are able to check the EDFA Alarms To move another alarm state push Up Down switch Table 8 Alarm Descriptions Name Variable Descriptions CaseTemp Case Temperature Shows the temperature state of the EDFA module OK Normal FAIL Abnormal IPM Input Power Shows the input optical signal power of the EDFA OK Normal FAIL Abnormal OPM Output Power Shows the output optical power of the EDFA OK Normal FAIL Abnormal POWER 1 Power Supply 1 Shows the Power Supply state of the EDFA module OK Normal FAIL Abnormal POWER 2 Power Supply 2 Shows the Power Supply state of the EDFA module OK Normal FAIL Abnormal FAN 1 Fanl Shows the FAN state of the EDFA module OK Normal FAIL Abnormal FAN2 Fan2 Shows the FAN state of the EDFA module OK Normal FAIL Ab
10. Shelf OFA response with requested data When an alarm occurs SNMP Trap containing the alarm information created by SNMP Agent is sent to SNMP Manager without request from the recipient SNMP Manager should be prepared with SNMP Trap Receiver for this feature Please note that TRAP is created for every alarm activation TRAP format Binding 1 sysUpTime Binding 2 snmpTrapOID Binding 3 Alarm OID and value DKT A S Fanoevej 6 36 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 5 3 WEB Interface Users have an option to monitor or control the EDFA through a WEB browser ADMIN and USER accounts are established separately for different access priorities The ADMIN account holder can set passwords for both ADMIN and USER accounts In addition the task of administrative work such as network connection monitor and control of EDFA can be performed under the ADMIN account The USER account holder usually the equipment operator has permission to monitor the EDFA s status 5 3 1 WEB browser Open a web browser Type the amplifier IP Address in the address edit box and press Enter CETE o n D amp a wes wa ETT oe um A pop up window will prompt for User Name and Password The default for ADMIN is user name admin and password admin The default
11. entPhysicalEntrY ese ee ee GR Re RR RA GRA GRA GR ee Gee ee ee ee ee Re Re ee nennen 32 5 2 2 property D EG AE ono ote ER EE RE eee 32 5 2 3 currentAlarmEntry sese Ge Re GR ee RA Ge RR Ge Re ek ee 32 5 2 4 discretePropertyEntry sess 33 5 22 5 alarmsIdent eer o reor edere EE N 33 5 2 6 commonldent ee ee Re GR RR RR RA GRA GRA Gee Gee ee ee nn eren nennen nennen 33 5 2 7 commonMulticastGroup esee GRA Ge RR Ge Re GR ee GR Ge Re Ge Re eke ie 34 52 8 heOpticalAmplifierGroup sesse sesse eke see ke eke ee GRA Ge AR Ge ek GR ee RA Ge AR Ge Re GR ee 34 5 2 9 NeBAasel Gent AE OE EE OE N r ser sekot 35 DKT A S Fanoevej 6 2 DK 4060 Kirke Saaby Tif 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 52 10 hePowerSupplly isi ee ee ee en ee en ie eee 35 522 11 heFans obe bused Ge EG OS EG Us Ue GE EG ee 36 Cu VO N EE OE OE EE OE EE NE ee 36 53 WEB iul sieesessed esse issie de soos eed se eed ese besoe de Ve eds Ge ees ge Ee die Sies ede ede Reede 37 5 3 1 WEB DrOWs r SS sing Ee se ese ere do E ee kt n oboe Ge Gegee Bi ee ds 37 EN BLOWS 38 533 Parameters TTE 39 sad ControlSet SE EG BG DE Ge i A oe Ee eg 40 5 35 Event lOG SES EE tied a OE EE Loeb Pd get ee 41 5 3 6 IP amp Losin sets 025 08 N i Ad
12. information ex ADMIN gt ver EEEE EE ie N de ole ais E de ie ok de ode ke de oie ie de oie Re de oie ode a oie de k oie N k ode k k k oie k k k k k kk kk Optical Amplifier Shelf System SNMP Board ver 1 0 for pxa270 d S W ver 01 01 02 00 Update Jun 13 2014 LLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLDLLLLLLLLLLLLLLLILEL 5 1 1 2 CLS Clear console screen pin 5 1 1 3 PING Confirm IP address to see if the IP address is assigned to any physical device ex ADMIN gt ping 192 168 0 1 PING 192 168 0 1 192 168 0 1 56 data bytes 64 bytes from 192 168 0 1 icmp_seq 0 ttl 64 time 2 3 ms 64 bytes from 192 168 0 1 icmp_seq 1 ttl 64 time 0 9 ms 64 bytes from 192 168 0 1 icmp_seq 2 ttl 64 time 0 9 ms 64 bytes from 192 168 0 1 icmp_seq 3 ttl 64 time 0 9 ms 192 168 0 1 ping statistics 4 packets transmitted 4 packets received 0 packet loss round trip min avg max 0 9 1 2 2 3 ms 5 1 1 4 LOGOUT Log out from RS 232 interface Not applicable for SNMP connection 5 1 1 5 IP View or set up IP Address Avoid IP address collision by using a unique IP address 5 1 1 6 SUBNETMASK View or set up SubnetMask Address Check network connection configuration before set up 5 1 1 7 GATEWAY View or set up Gateway Address Confirm Gateway address of connected network before set up 5 1 1 8 RESET Reset network connections for configuration change or any other needs for connection reset OFAU op
13. optical input power of the EDFA is satisfied clean the surface of the optical input connector of the EDFA Remember the earlier requirement of clean optical connectors M Case 3 Check the Laser ON OFF state on the Laser Control menu M Case 4 In this case either the capability of the Pump Laser Diode degraded or it is out of order The EDFA needs to be repaired or replaced M Case 5 In this case Status LED turns yellow at first Then both Laser LED and Status LED turn red This is cause by the failure that the internal temperature of the Pump Laser Diode is abnormal It requires either adjustment or replacement DKT A S Fanoevej 6 47 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 If you identify the problems as shown in the Table or have an unidentified problem you must stop operating the EDFA immediately Please contact manufacturer DKT A S Fanoevej 6 48 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com
14. 0 Octets RO alaamLogNumberOfEntry Count of log information 1 100 alarmLogLastIndex Last index of log index alarmLogIndex log index 1 32767 alarmLogInformation alarm log information log information format Time alarm type commonNeStatus OID Alarm Value x Alarm log Index 1 Last Index 5 2 6 commonldent commonldent OID 1 3 6 1 4 1 5591 1 3 Name OID Type Access Note commonLogicalID 1 3 6 1 4 1 5591 1 3 1 1 0 Octets R W commonVendor 1 3 6 1 4 1 5591 1 3 1 2 0 Octets RO commonModelNumber 1 3 6 1 4 1 5591 1 3 1 3 0 Octets RO commonSerialNumber 1 3 6 1 4 1 5591 1 3 1 4 0 Octets RO commonVendorInfo 1 3 6 1 4 1 5591 1 3 1 5 0 Octets RO commonReset 1 3 6 1 4 1 5591 1 3 1 7 0 Integer32 R W commonAlarmDetectionControl 1 3 6 1 4 1 5591 1 3 1 8 0 Integer32 R W commonNetworkAddress 1 3 6 1 4 1 5591 1 3 1 9 0 IP Address RO commonTrapCommunityString 1 3 6 1 4 1 5591 1 3 1 11 0 Octets R W PUBLIC 33 DKT A S Fanoevej 6 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 commonlnternal Temperature 1 3 6 1 4 1 5591 1 3 1 13 0 Integer32 RO commonTime 1 3 6 1 4 1 5591 1 3 1 14 0 Integer32 RO commonVarBindings
15. 1 1 3 1 1 1 1 2 5 1 Integer32 RO heOpAmplnputIndex 1 3 6 1 4 1 5591 1 11 1 3 1 1 2 1 1 5 1 Gauge32 RO heOpAmpInputPower 1 3 6 1 4 1 5591 1 11 1 3 1 1 2 1 2 5 1 Integer32 RO heOpAmpLaserIndex 1 3 6 1 4 1 5591 1 11 1 3 1 1 3 1 1 5 x Integer32 RO heOpAmpLaserTemp 1 3 6 1 4 1 5591 1 11 1 3 1 1 3 1 2 5 x Integer32 RO heOpAmpLaserBiasCurrent 1 3 6 1 4 1 5591 1 11 1 3 1 1 3 1 3 5 x Gauge32 RO heOpAmpOutputIndex 1 3 6 1 4 1 5591 1 11 1 3 1 1 4 1 1 5 y Gauge32 RO heOpAmpOutputPower 1 3 6 1 4 1 5591 1 11 1 3 1 1 4 1 4 5 y Integer32 RO heOpAmpOutputGainType 1 3 6 1 4 1 5591 1 11 1 3 1 1 4 1 5 5 y Integer32 RO heOpAmpUnitOutputStatus output status on off of optical amplifier heOpAmpUnitOnOffControl output status control of optical amplifier heOpAmpInputIndex index of input power 34 DKT A S Fanoevej 6 DK 4060 Kirke Saaby TIf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 heOQpAmpInputPower input power value heOpAmpLaserlIndex index of LD heOpAmpLaserTemp temp of LD heOpAmpLaserBiasCurrent bias current fo LD heOpAmpOutputIndex index of output power heOpAmpOutputPower value of output power heOpAmpOutputGainType output power gain type AGC APC x Pump LD Index 1 7 y Output Power P
16. 1 1 7 x octets RO entPhysicalIndex entity physical index entPhysicalDescr entity physical description entPhysicalClass entity physical class entPhysicalName entity physical name x Entiry Physical Index 1 6 5 2 2 propertyEntry propertyIdent OID 1 3 6 1 4 1 5591 1 1 Name OID Type Access E T C parameterOID 1 3 6 1 4 1 5591 1 1 1 1 1 x object identifier RO alarmEnable 1 3 6 1 4 1 5591 1 1 1 1 2 x octets RO currentAlarmState 1 3 6 1 4 1 5591 1 1 1 1 3 x Integer32 RO analogAlarmHIHI 1 3 6 1 4 1 5591 1 1 1 1 4 x Integer32 RO analogAlarmHI 1 3 6 1 4 1 5591 1 1 1 1 5 x Integer32 RO analogAlarmLO 1 3 6 1 4 1 5591 1 1 1 1 6 x Integer32 RO analogAlarmLOLO 1 3 6 1 4 1 5591 1 1 1 1 7 x Integer32 RO parameterOID analog alarm parameter OID alarmEnable analog alarm enable currentAlarmState current alarm status of analog alarm parameter analogAlarmHIHI analog alarm HIHI threshold value analogAlarmHI analog alarm HI threshold value analogAlarmLO analog alarm LO threshold value analogAlarmLOLO analog alarm LOLO threshold value x Analog Alarm Index 1 16 5 2 3 currentAlarmEntry discretePropertyEntry OID 1 3 6 1 4 1 5591 1 1 2 1 Name OID Type Access E T C currentAlarmOID 1 3 6 1 4 1 5591 1 1 2 1 1 1 object identifier RO currnetAlarmAlarmState 1 3 6 1 4 1 5591 1 1 2 1 2 1 Integer32 RO currentAlarmAlarmValue 1 3 6 1 4 1 5591 1 1 2 1 3 1 Integer32 RO
17. 1 3 6 1 4 1 5591 1 3 1 15 0 Integer32 RO commonResetCause 1 3 6 1 4 1 5591 1 3 1 16 0 Integer32 RO commonLogicalID logical ID commonVendor vendor commonModelNumber model number commonSerialNumber serial number of model common Vendorlnfo vendor information commonReset software reset write 1 commonAlarmDetectionControl Detection control of all alarm parameter commonNetworkAddress network address of system commonTrapCommunityString trap community default public commonInternalTemperature temperature of OFA module commonTime time posix value commonVarBindings value of binding commonResetCause cause of lastest reset 5 2 7 commonMulticastGroup commonMulitcastGroup OID 1 3 6 1 4 1 5591 1 3 3 Name OID Type Access Note commonMaxMulticastAddress 1 3 6 1 4 1 5591 1 3 3 1 0 Integer32 RO commonMulticastAddressIndex 1 3 6 1 4 1 5591 1 3 3 2 1 1 x Integer32 RO commonMulticastAddressNumber 1 3 6 1 4 1 5591 1 3 3 2 1 2 x Octets R W commonMaxMulticastAddress Maximum number of multicast address commonMulticastAddressIndex Index multicast address commonMulticastAddressNumber Address of mulitcast x Mulitcast Address Index 1 5 5 2 8 heOpticalAmplifierGroup heOpticalAmplifierGroup OID 1 3 6 1 4 1 5591 1 11 1 3 Name OID Type Access Note heOpAmpUnitOutputStatus 1 3 6 1 4 1 5591 1 11 1 3 1 1 1 1 1 5 1 Integer32 RO heOpAmpUnitOnOffControl 1 3 6 1 4 1 5591 1 1
18. 4 ADMIN gt snmp get trapen 1 SNMP Trap enable 1 OFF SNMP GET TRAPCOMM Index ex ADMIN gt snmp get trapcomm 1 SNMP Trap Community 1 public SNMP SET ROCOMM string ex ADMIN gt snmp set rocomm public snmp setting is Successful SNMP SET RWCOMM string ex ADMIN gt snmp set rwcomm private snmp setting is Successful SNMP SET TRAPEN Index ON OFF ex ADMIN gt snmp set trapen 1 on snmp setting is Successful SNMP SET TRAP Index IP Address Ex ADMIN gt snmp set trap 1 92 168 0 31 snmp setting is Successful This setting will be applied after reboot SNMP SET TRAPCOMM Index string ex ADMIN gt snmp set trapcomm 1 public snmp setting is Successful 5 1 1 13 NTP NTP commend synchronizes the shelf unit s time from time server To use the NTP features user needs to set NTP server and Time zone accordingly ex ADMIN gt ntp Usage NTP ARGI ARG2 ARG3 ARGx ARGI GET SET ARG2 GET SERVER NTP Server IP Information TIMEZONNE Time Zone SET SERVER TIMEZONNE Time Zone ARG3 SERVER Enter the IP1 xxx xxx xxx xxx TIMEZONNE 24 24 ARGx SERVER Enter the IPx xxx xxx xxx xxx NTP SET SERVER IP1 IP2 IP5 DKT A S Fanoevej 6 29 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dkt
19. As the EDFA operates on high current and high optical power condition any sudden removal of input signal or plugging out of input signal line may cause fatal damage to the active components in the amplifier It is recommended to shutdown the laser using ALS Key before turn on or turn off the power switch In case of Power Supply Unit PSU exchange make sure to turn off the power switch of the PSU before plug in or plug out the PSU to or from the Amplifier Shelf In addition DKT A S Fanoevej 6 5 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 1 5 1 6 it is also strongly prohibited from iterating of power on off in very shot interval The recommended on off interval is at least Ssecconds The optical adapters for the EDFA input and output are located on the front panel of the Shelf Type EDFA When received from the factory the optical adapters have a cap on them for safety and protection Until the Shelf is installed you need to leave the caps on The operator user must keep the surface of the optical connecter clean If the surface of the optical connecter is contaminated with dirt or obstructions the surface of the optical connecter may be damaged as soon as the Laser is turned on Grounding Considerations The Shelf Type EDFA includes Laser Diodes and Photo Diodes those
20. D Series June 2014 In this state push the ENTER switch Note When the Laser is selected the Off the output of the EDFA also turns off and the Laser LED becomes red E Buzzer ON If an alarm has activated on the EDFA Buzzer sound is activated You will hear a beeping sound As soon as the alarm condition of the EDFA is removed the Buzzer sound automatically stops From the below screen the first line indicates the current selected buzzer state of the EDFA If you want to select a state different from your current buzzer state using the Up or Down switch move the cursor to the menu that contains the state you wish to select Push the ENTER switch If you want to turn off the buzzer push the Enter switch to move the cursor to the OFF position In this state push the ENTER switch When the Buzzer OFF is selected and the EDFA alarm is activated the Buzzer sound is not activated 4 2 4 Status In the Status menu you are able to monitor the operational state of the EDFA DKT A S Fanoevej 6 16 DK 4060 Kirke Saaby TIf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 If you push the Enter switch the cursor moves to the Input Power menu The Input Power is the optical input power Input Power is displayed The Output Power is the EDFA output power monitoring The Output
21. DKT OFA CCS CCD Series 1U 2U Shelf Network Managed Optical Amplifier User s Manual June 2014 DKT A S Fanoevej 6 DK 4060 Kirke Saaby Tlf 445 4646 2626 445 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 Contents 1 INTRODUCTION see en de ka ie ii ee on de ie Kan ie Ke N n kin e n die 5 11 About this Manual 5 12 General Descriptions Se EG se 5 13 Mechanical Dimensions and Operational Conditions ee Be ee See Ee Se EG se 5 1 4 Precautions for Installation and WarningS sesse sesse ese sees See Se Se EG Be EG Be EE ee Ge Ee Se EG se an 5 15 Grounding Considerations se ese se ee See se Ee Be EE enses ense Ee Se EA Be sens Be sesto sees suse Se EG Se 6 1 6 Lasser Safety EE EE 6 2 PREPARATION ese ee de de UN eed EUN DU IE ek ok Ge de Ge ie ei de ie 7 21 diuum C N EE NE OG iioi sious 7 2 2 EET TO SCRI R 7 2 3 How to Connect the Power Supply e eres reser esee esee ee ernst setas tns Bee Se ee EE Ge EE Ge 7 24 How to connect the optical cable cerei esee esses Be EE Ee SE EE Be EE enses tns EE Se EG 8 3 DESCRIPTION EE EE EE EE EE 9 SN dulcem ds ede es Nee ede ee see ed Sk Nee ede ke gee ee bee SE de ed ee
22. F GET LOG log information Max log count ex 100 max log index 32767 ADMIN gt shelf get log Log Count 382 1 1024 Last log index 382 1 32767 index 1 index 2 index 3 index 4 index 5 index 6 index 7 alarm index 8 alarm index 9 alarm 4 805c12 05 08 060f2b06010401ba29 1402060 104030300 02010c 4f805c85 05 08 060f2b06010401ba29 1402060 104030300 02010d 4 8067c2 05 08 060f2b06010401ba29 1402060 104030300 02010c 4f806b10 05 08 060f2b06010401ba29 1402060104030300 02010c 4 806c37 05 08 060f2b06010401ba29 1402060 104030300 02010d index 10 4f806c38 05 08 06112b06010401ba2914020602010410010204 02028232 Optical output port No 4 alarm index 11 4f80707a 05 08 060f2b06010401ba291402060104030300 02010d Pwr Supply1 alarm occurred index 12 4f80707a 05 08 060f2b06010401ba291402060201040f00 0205fffffffb28 IPM alarm occurred index 13 4f807072 05 08 06112b06010401ba2914020602010410010201 02028232 Optical output port No 1 alarm Pwr Supplyl alarm occurred Pwr Supplyl alarm occurred Pwr Supplyl alarm occurred Pwr Supplyl alarm occurred Pwr Supplyl alarm occurred 4 806c37 05 08 060f2506010401ba291402060201040f00 0205fffffffb28 IPM alarm occurred 4 806c37 05 08 06112b06010401ba2914020602010410010201 02028232 Optical output port No 1 4 806c37 05 08 06112b06010401ba2914020602010410010202 02028232 Optical output port N
23. If the FAN alarm signal is activated the color of status LED changes green to yellow 32 3 Rear Panel The rear panel of the Shelf Type EDFA consists of two pluggable type power modules and two fans sae Figure 3 Rear Panel DKT A S Fanoevej 6 11 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 4 OPERATION 4 31 Summary In this chapter the operation of the EDFA using the LCD menu will be explained The diagram below shows the operational menu tree selectable MAIN MENU BME Menu Provision EDFA ACT EDFA DEACT Laser Key Switch is ON Control LASER Laser ON MD gt E B Laser OFF Buzzer Buzzer ON Buzzer OFF Status Input Power Output Power LD Bias LD Thermistor Case Temperature EDFA Model Test LED Buzzer Function Setting Time IP Address DKT A S Fanoevej 6 1 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 42 LCD Operation The functions of the Shelf Type EDFA are supported by selecting the LCD Menu switch on the front panel If an electric power is applied the initial display of the LCD display is as follows WARNING In all LCD menus if you do n
24. and then the cursor is on the Provision menu From the cursor on the Provision if you push the Enter switch the cursor moves from the Provision Menu to the SUB MENU The first line of the above screen indicates the current state of the EDFA The initial state of the Provision menu depends on the setting state If you want to change the current state move the cursor by the Up or Down switch to the menu you wish to select From the current state move the cursor by Up or Down switch to the position on the DEACT menu Push the Enter switch The LCD screen displays the operation selected above is complete If you push Enter or Menu switch the cursor moves to the DEACT menu And if you do not select a menu switch for about 15 seconds the menu automatically returns to the previous state and display After selecting the desired state if you want to move to the MAIN MENU above on the screen you can change the menu with the Menu switch W Provision State Descriptions Within the Provision menu the start state is the ACT Activate state when the power is turned on If you select the DEACT state at the Provision Menu the EDFA is working an normal operation except the alarm information The table shows the operational state of the EDFA at the Provision menu DKT A S Fanoevej 6 14 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Op
25. are extremely sensitive to electrical static You must always handle the EDFA with extra care When you unpack or install the EDFA you must obey all the ESD electro static discharge precautions as well as work with a grounded wrist strap Therefore proper ESD precautions are always recommended To avoid performance degradation or loss of functionality install in a properly grounded working shelf The F G terminal must be connected to Earth Ground for protection of the unit during installation and operation To protect the installation and to prevent unexpected accidents such as lightning static electricity short circuit surges etc you must use a grounded receptacle for the AC power cord has Laser Safety IEC 60825 Class 1M laser product All versions are Class 1M laser products per IEC 60825 1 2007 03 CAUTION Use of controls adjustment and procedures other than those specified herein may result in hazardous laser radiation exposure pancer gt ADANGER INVISIBLE LASER RADIATION IS EMITTED FROM THE END INVISIBLE LASER RADIATION AVOID DIRECT EXPOSURE TO BEAM OF FIBER OR CONNECOTR Wavelength 1550nm Avoid direct exposure io beam Max Output30mw Do not view beam directly with Class M Laser Product optical instruments Complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated June 24 2007 DKT A S Fanoevej 6 6 DK 4060 Ki
26. arm Now All alarm value of SHELF system FAN status alarm No 1 1 No 2 1 Value 1 is OK Value 2 is FAIL Power supply status alarm No 1 5 No 2 1 Value 1 is OK Another Value is FAIL Key Als Status Laser status 2 Value 1 Laser On Value 2 Laser Off Casetemp status alarm 1 Value 1 is OK Another Value is FAIL Optical component status alarm IPM status alarm 5 OPM status alarm 5 LD component status alarm LD No 1 BIAS alarm 1 TEMP alarm 1 LD No 2 BIAS alarm 1 TEMP alarm 1 LD No 3 BIAS alarm 1 TEMP alarm 1 LD No 4 BIAS alarm 1 24 DKT A S Fanoevej 6 DK 4060 Kirke Saaby TIf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier OFA CCS CCD Series User s Manual Rev 1 3 June 2014 TEMP alarm 1 SHELF GET SYSTH Shelf system threshold value ex ADMIN gt shelf get systh SHELF system threshold value Casetemp alarm threshold value information AlarmHIHI 750 AlarmHI 650 AlarmLO 100 AlarmLOLO 200 Output voltage information of Power Supply No 1 AlarmHIHI 53 AlarmHI 52 AlarmLO 48 AlarmLOLO 47 Output voltage information of Power Supply No 2 AlarmHIHI 53 AlarmHI 52 AlarmLO 48 AlarmLOLO 47 Divide value by 10 SHEL
27. comega com T Network Managed Optical Amplifier OFA CCS CCD Series User s Manual Rev 1 3 June 2014 ADMIN gt ntp set server 141 223 182 106 172 0 0 1 NTP GET SERVER ADMIN gt ntp get server server 141 223 182 106 server 172 0 0 1 NTP SET TIMEZONE GMT 9 ADMIN gt ntp set timezone 9 NTP GET TIMEZONE ADMIN gt ntp get timezone 30 DKT A S Fanoevej 6 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier OFA CCS CCD Series User s Manual Rev 1 3 June 2014 5 1 2 Network Configuration User needs to set up network configuration for the product Factory default IP address is 192 168 0 100 Network configuration is to be modified by either SNMP or Telnet The modified configuration is enacted by reboot The reset command of CLI also allows the modified configuration to be enacted If information on modified configuration is forgotten then use the console to check or reset IP address Note that network configuration can be set only by ADMIN account Factory Default Item Default Value IP 192 168 0 100 SubnetMask 255 255 255 0 Gateway 192 168 0 1 5 1 3 SNMP Configuration This unit supports SNMPv1 SNMPv2 and SNMPv2c SNMPv3 will not be supported until next software upgrades Using MIB Table for SNMP interface GUI Graphic Use
28. eb www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 Optical Optical Source Attenuator Figure 4 Shelf Type EDFA Measuring Instrument Setup Test procedure of the Shelf Type EDFA 1 Connect the measuring instrument in Figure 4 2 Check the optical signal power from the optical source by using the optical power meter The optical signal power from the optical source must be above the minimum optical input power of EDFA The minimum optical input power and operating wavelength are described on the TEST REPORT document 3 Make sure to check the measurable power range of the optical power meter As the EDFA optical output power level is very high the optical power meter may be heavily damaged if not properly adjusted 4 Connect the output adapter of the EDFA to the optical power meter through the optical jumper cord 5 If the optical power meter is unable to measure the optical output power of the EDFA directly you must use the optical attenuator 6 Under normal operating conditions that is LASER ON state and the optical input power condition is within the optical input power range of the EDFA check the optical output power of the EDFA 6 4 Alarm Test The LOS Alarm of the Shelf Type EDFA occurs when the optical input power of the EDFA is lower than the minimum optical input power condition see the TEST REPORT If you want to check the LOS Alarm tu
29. ee ei idee ele 42 537 SNMPSef See SE Se Ge de Ee Gee de GR SE N De ie ee ede Be tes 43 ss Maal om eb E ee N EE Ee Ee EE E 44 6 PERFORMANCE CHECK 1 eek eek es eek eek eek este ke ek eek eaa eek eek ee ke 45 6 1 Precautions for Testing sesse sees see Bee See Se ee seen seen een Ge EG EG BEG Bee Se ee ee Ee ste EE Ge Ge EG ee 45 6 2 Power NIIT ARR RTT 45 6 3 Primary M LT P 45 6 3 1 Required Measuring Instruments sees see ee se ee Ge ek GR ee SR Ge RR Ge ek eke ie 45 6 3 2 Performance Test Ee Ee EE De ER EE e Ne Re ES Ee Ee che Ee Re EG GE Ee eke ee 45 64 Alarm Test e 46 7 MAINTENANCE uu ccccccnecnscecnecneenscneeeeeeensenseeeneensensensneeneenseuseeseenneeass 47 7 1 Maintenance Cautions sisesscscssccssssesssssisacccsstsscsssesessessensssosssessseesssobieseescssscoesoessssessosscsssasseseoses 47 7 2 Trouble Shooting Procedures esee See se Ee Be eee Be EE BEE Ee Se EG Be sins Be ee Re Se suse ta ee ae 47 DKT A S Fanoevej 6 3 DK 4060 Kirke Saaby TIF 45 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 Figure Contents Figure 1 Electric Power Supply Connection iese esse ee ee ee ee ee ee n ee ee ee ee ee ee ee ee ee ee ee ee ee Figure 2 Front Panel Fisur Re r P
30. eed to check the power in cord and then the AC power fuse 2 4 Howto connect the optical cable The Shelf Type EDFA supports only SC APC optical connectors According to the users requirements connect the optical cable to the input and the output optical adapters on the front panel of the Shelf Type EDFA DKT A S Fanoevej 6 8 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com User s Manual Rev 1 3 June 2014 Network Managed Optical Amplifier OFA CCS CCD Series 3 DESCRIPTION 31 Summary In this chapter general information about the front and rear panels of the Shelf type EDFA are explained The individual switches and connections will be introduced 3 2 Panel Description 3 2 1 Front Panel Figure 2 shows the front panel of the Shelf Type EDFA The components are an LCD capable of 2x20 letters for reading the menu states 4 menu control switches for selecting the LCD menus a Laser ON OFF key switch an EDFA state indicating LED and optical adapter cassette Ethernet Optical Amplifier j ee wa oar oz ows ows ous ouz ous S fo S 5 S 5 S gt S o ls 8g WARNING AVOID EXPOSURE INVISIBLE LASER RADIATION IS EMITTED FROM THESE APERTURES b 2U Shelf Figure 2 Front Panel Mm Laser On Off Key Switch
31. em reboot and Factory Reset can be performed Caution should be exercised as the optical amplifier operation can be affected critically Only ADMIN account user can access this page Lai Optical ampie e Sinn gt B P B operet ama an7 i g gga ee IP amp LOGIN information Monitoring l Parameter p 192 168 0 170 Control set Subeat mask 255 355 255 0 Event Log Gateway 192 168 0 1 j i EA IP f Login set SNMP set 10 amp Password Martial 0 User Aan admi yp SET Bethe Rate lt a System Reboot Rabeot Factory Reset Factoreset i DKT A S Fanoevej 6 42 DK 4060 Kirke Saaby TIf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 5 3 7 SNMP set SNMP Trap IP addresses can be set and enabled disabled The Trap community information is case sensitive and should be matched to the MIB browser or NMS settings that is communicating with the device Only the ADMIN account user can access this page daars Ci Optical Aegifer mwenn c B P Ons ese mous gagga Sn yo SNMP Settings Monitoring Parameter TRAD adress TRAP Phatt E Control set wr 0 0 0 0 disatie Event Log we 0 0 0 0 disatle IP amp Login set 21 0 0 0 0 disatle SNMP set 7 0 0 0 0 disatle Manual ss 0 0 0 0 disatlo Trap community R pubic Trap community Kw private ET stem sysContact se sysrame Opt
32. en the input optical signal power to the EDFA is lower than the minimum input conditions the color of status LED changes green to red see the TEST REPORT The threshold for triggering the loss of input signal alarm is set below the minimum optical input level If the LOS alarm is activated the EDFA automatically changes to the Laser Shutdown state the output power is turned off In response to a loss of input signal the bias current of the pump laser diode goes into a shutdown state to prevent the development of dangerous laser diode operation conditions If laser shutdown does not occur the pump laser diode can be damaged This condition is automatically reset when the input power is restored to a power above the alarm threshold for the EDFA The EDFA returns to its normal state the color of status LED changes red to green and the Laser ON state condition returns W LOP Loss of Output Power Alarm When the optical output power of the EDFA is lower than the reference power the color of status LED changes green to red see the TEST REPORT This level is commonly 3dB below the reference output power If the Laser OFF state is selected from the LCD menu the color of status LED changes 10 Tlf Fax DKT A S Fanoevej 6 DK 4060 Kirke Saaby 45 4646 2626 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 green to red
33. eration is not affected by this command Only network connection is to be reset 5 1 1 9 MPU Check MPU information and status of physical devices connected the MPU In addition basic set up of MPU is possible See below for examples ex ADMIN gt mpu Usage mpu ARG1 ARG2 ARG3 DKT A S Fanoevej 6 22 DK 4060 Kirke Saaby TIf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 ARGI get set ARG 2 get sysinfo MPU module Information status MPU module Status config MPU module Configuration inpower Input Power Value of MPU Module set time descr MPU Description als Machine All ALS Control buzz MPU Buzzer Setting ARGS3 time Set New Time Y YY YMMDDhhmmss descr Enter User define string Len 0 20 als ON OFF buzz ON OFF MPU SET DESCR Len 0 20 Input MPU Description ex MPU SET DESCR Shelf OFA for Node 1 MPU SET TIME YYYYMMDDhhmmss Input time information for MPU Use 14 digits to input the time information such as YY YYMMDDhhmmss ex MPU SET TIME 20061207091830 MPU GET SYSINFO View MPU Model Name Description Serial Number Firmware Version Hardware Version ex ADMIN gt mpu get sysinfo Model Name Description Serial Number Hardware Version 1 00 Firmware Version 1 00 MPU GET STATUS View MPU t
34. for USER is user name user and password user Different user levels can be set up for unlimited or restricted user privileges eo A username anc panneord are being requested Dy http 192 1880 170 The site say EDEA Jun Name Paciword DKT A S Fanoevej 6 37 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 5 3 2 oa Ange iei Monitoring The present status of the optical amplifier can be monitored Status data can be automatically refreshed at a user selectable rate The Default refresh period is 15 seconds The monitoring page is accessible through all of the user levels 21880170 CELAS Manitoriri Parameter Control set Event Log Ped ABR BF VAA Bua System Shef Status information AE EE Sofwarever OFA CCD 2108 TC20120410001 G01A00 1 0 000000000 Staten IP amp Login set amp SNMP set Maral Optical Fiber Ampitfierl OF A Module Status OFA information Model name Serane Hw vers OFA CCD 1T0 amp 201204000000 1 50 OFA Optical States DKT A S Fanoevej 6 38 DK 4060 Kirke Saaby Tif 445 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 5 33 ER
35. ical Amplifier L SET asysLocation CATY Lab set commonLogicall sv se edfamventoryserBata set DKT A S Fanoevej 6 43 DK 4060 Kirke Saaby Tlf 45 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 5 3 8 Manual The user s manual in PDF format is resident on the amplifier and available via the web GUI for convenience This link is accessible through all the user levels ey Optical bmplfer 192106017 RF wet Frea 41087 EST ET Sh MOE Monitoring Parameter Control set Event Log IP amp Login set SNMP set Manual OFA CCS CCD Series 1U 2U Shelf Network Managed Optical Amplifier User s Manual April 2012 DKT A S Fanoevej 6 44 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 6 PERFORMANCE CHECK 6 1 Precautions for Testing In this chapter after completing installation of the Shelf Type EDFA the proper operation power supply procedures monitor connection start test method and other instructions are explained Before applying power to the Shelf Type EDFA check the Optical cable connections on the rear panel of the EDFA once more before turning the Power Switch on 6 2 Power Supply Below show
36. ime information ex ADMIN gt mpu get status Current Time 2012 04 06 19 56 28 Provision Bit Ox1 Card ACT Bit 0x1 Card Alarm Bit 0x0 5 1 1 10 SHELF Basic information of shelf system ex ADMIN gt shelf Usage shelf ARG1 ARG2 ARG3 ARG4 ARGI get set ARG 2 get info SHELF system information psinfo Power Supply Output Power faninfo FAN status alarm Now all alarm value of shelf system systh Alarm threshold value of shelf system log System log information set psen Power Supply Alarm Enable Disable log Log clear AGR3 psen index 1 2 AGRA psen value 1 F alarm enable 0 alarm disable DKT A S Fanoevej 6 23 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier OFA CCS CCD Series SHELF GET INFO View Logical ID SHELF GET PSINFO Power supply module information ex User s Manual Rev 1 3 June 2014 ADMIN gt shelf get psinfo Power Supply Voltage Information Power supply module count 2 Power supply No 1 type DC 48 PS output voltage 1 3 V Alarm enable value bit F Power supply No 2 type AC 100V 240V PS output voltage 5 1 V Alarm enable value bit F SHELF GET ALARM All alarm status of shelf system T value is OK Another value is Not OK ex ADMIN gt shelf get al
37. method Chapter 7 Maintenance and repair 12 General Descriptions The Shelf Type EDFA operates in the range of 1550 nm wavelength The Pump Laser Diode is used as an Erbium Doped Fiber pumping energy source for the EDFA For better system performance isolators are installed on the input and output of the EDFA s optical terminals For convenient operation SNMP LED indicators LCD and Menu functions are assisted The Shelf Type EDFA is available in a variety of electrical power options such as AC 100V 240V DC 48V 13 Mechanical Dimensions and Operational Conditions The Shelf Type EDFA is installable in a 19 1U or 2U Shelf The size is 432 W x 375 D x 44 or 88 H mm The storage temperature must be kept between 40 C to 85 C The relative humidity range is 10 95 The operating temperature range is between 0 C to 50 C The LCD Backlight is assurance between 10 C to 60 C The electrical power consumption depends on the applied use of the EDFA For more information about electrical power consumption read the TEST REPORT 1 4 Precautions for Installation and Warnings The user must ensure that there is enough air flow and convection through the upper and lower panels The Shelf Type EDFA has its own internal circuitry plus an internal electrical voltage converter Both generate heat Unrestricted air flow is required for proper operating conditions Do not shut down the input signal when the EDFA is turned on
38. ne the input power of the EDFA by using the optical variable attenuator to a value below the minimum optical input signal level When the LOS Alarm is activated the color of the Status LED on the front panel is changed to red At this time the Shelf Type EDFA automatically shifted to the Automatic Laser Shutdown ALS mode and the LOS Alarm is also activated The state information watch program of the Shelf Type EDFA stores both the activated events type and the event time If the Buzzer selection in the LCD menu is in the ON state the Buzzer sound goes beep The Buzzer sound can be eliminated by pushing the any switch on the front panel or by cancel the Buzzer ON selection on the LCD menus If the Buzzer selection in the LCD menu is in the OFF state the Buzzer sound does not sound and just the state information and time values are stored When the optical input power of the Shelf Type EDFA is normal the LED on the front panel and the Buzzer sound automatically turn off In this case the state information also is automatically stored DKT A S Fanoevej 6 46 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 7 MAINTENANCE 7 1 Maintenance Cautions If the Shelf type EDFA is out of order a specialized expert must check the EDFA and the problem The expert should try to resolve the
39. normal LD1 BIAS Current Shows the state of the Pump Laser Diode Bias current OK Normal FAIL Abnormal LD1 THER Thermistor Shows the temperature state of the Pump Laser Diode OK Normal FAIL Abnormal T EDFA Model Name is the EDFA model name of built in the Shelf DKT A S Fanoevej 6 DK 4060 Kirke Saaby Tlf 45 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 4 2 5 Test From the Test menu you are able to test the LED Buzzer If you push the Enter switch the cursor moves to the LED Test menu In the LED Test menu the operating state of all the LEDs can be checked If you push the Down switch the cursor moves to the Buzzer Test menu Then if you push the Down switch the operating state of the Buzzer can be checked 4 2 6 Function Setting The Function Setting menu is Time The timer setting procedure for the internal timer is as follows In the below screen the Current Time indicates the present date and time In the Setting Time Menu you can change the date and time to the values you need Using the Up Down Enter switch move the cursor to the position that you want to change If you push the Down switch the cursor moves to another position And Up switch change the time value DKT A S Fanoevej 6 19 DK 4060 Kirke Saaby Tif 445 4646 2626 Fax
40. o 2 4f806c37 05 08 06112b06010401ba2914020602010410010203 02028232 Optical output port No 3 SHELF SET LOG log information clear Ex ADMIN gt shelf set log ADMIN gt shelf get log 25 DKT A S Fanoevej 6 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 Log Count 0 1 1024 Last log index 0 1 32767 5 1 1 11 OFAU Check information on OFAU and its status In addition basic set up of OFAU is possible See below for examples ex ADMIN gt ofau Usage ofau ARG1 ARG2 ARG3 ARGI get set ARG 2 get sysinfo OFAU Model Information status OFAU Module Status config OFAU Module Config Data opmode OFAU Operation Mode set opmode OFAU Operation Mode ref Reference Output Power losth OFAU LOS Alarm Threshold lopth OFAU LOP Alarm Threshold ARGS3 set opmode Card index 1 ref Card index 1 losth lopth hihi value 0 ARGA set opmode Value 20 AGC or 30 APC ref Value Reference value 10 losrh lopth hi value 0 ARGS set losrh lopth lo value 0 ARG6 set losrh lopth lolo value 0 OFAU GET SYSINFO View OFAU module basic Information ex ADMIN gt ofau get sysinfo OFAU Slot Number 1 Model Name OFA CCD 2108 Description EDFA Serial N
41. ogText text information of alarm x Log Table Index 1 Last Index 52 10 hePowerSupply hePowerSupply OID 1 3 6 1 4 1 5591 1 11 2 2 Name OID Type Access hePsUnitDescription 1 3 6 1 4 1 5591 1 11 2 2 1 1 1 1 3 x Octets RO hePsOuputIndex 1 3 6 1 4 1 5591 1 11 2 2 1 1 2 1 1 3 x Integer32 RO hePsOutputVoltage 1 3 6 1 4 1 5591 1 11 2 2 1 1 2 1 2 3 x Integer32 RO hePsUnitDescription description AC 110 220 DC 48 of power supply module hePsOuputIndex index of power supply module hePsOutputVoltage output voltage of power supply module 35 DKT A S Fanoevej 6 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 x PS Index 1 2 5 2 11 heFans heFans OID 1 3 6 1 4 1 5591 1 11 2 3 Name OID Type Access heFanUnitAlarm 1 3 6 1 4 1 5591 1 11 2 3 1 1 1 1 1 x Integer32 RO heFanStatusIndex 1 3 6 1 4 1 5591 1 11 2 3 1 1 2 1 1 1 x Gauge32 RO heFanStatusIndex 1 3 6 1 4 1 5591 1 11 2 3 1 1 2 1 3 1 x Integer32 RO heFanUnitAlarm status of fan l is ok another value is not ok heFanStatusIndex index of fan heFanStatusAlarm status of fan 1 is ok another value is not ok x FAN Index 1 2 52 12 Trap In SNMP SNMP Manager console first request data and then SNMP Agent
42. ort Index 1 8 5 2 9 heBaseldent heBaseldent OID 1 3 6 1 4 1 5591 1 11 2 Name OID Type Access Note heCommonTime 1 3 6 1 4 1 5591 1 11 2 1 1 1 1 1 1 1 0 Octets RO heCommonTemperature 1 3 6 1 4 1 5591 1 11 2 1 1 1 1 1 1 2 0 Integer32 RO heCommonSoftwareReset 1 3 6 1 4 1 5591 1 11 2 1 1 1 1 1 1 3 0 Integer32 RO heCommonAlarmDetectionControl 1 3 6 1 4 1 5591 1 11 2 1 1 1 1 1 1 4 0 Integer32 RO heCommonLogNumberOfEntries 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 1 Integer32 RO heCommonLogLastIndex 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 2 Integer32 RO heCommonLogIndex 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 3 1 1 x Gauge32 RO heCommonLogOID 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 3 1 2 x Object Identifier RO heCommonLogValue 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 3 1 3 x Integer32 RO heCommonLogsState 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 3 1 4 x Integer32 RO heCommonLogTime 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 3 1 5 x Octets RO heCommonLogText 1 3 6 1 4 1 5591 1 11 2 1 1 1 2 3 1 6 x Octets RO heCommonTime time heCommonTemperature internal temperature of Optical Amplifier heCommonSoftwareReset software reset write 1 heCommonAlarmDetectionControl detection control of all alarm parameter heCommonLogNumberOfEntries count of log information heCommonLogLastIndex lastest index of log heCommonLogOID OID of alarm parameter heCommonLogValue alarm value heCommonLogState alarm state heCommonLogTime activated time of alarm heCommonL
43. ot select a menu switch for about 15 seconds the menu automatically returns to the previous menu state 4 2 4 Menu Selects The main menu is Provision Control Status Test Function Setting IP Address You can select any menu by the Menu switch The procedure of selection in the MAIN MENU is as follows Push the Menu switch on the start screen The LCD display is changed to the next screen and then the cursor is on the Provision menu If you push the Down switch the cursor moves to the Control menu With the cursor placed on the menu Control if you push the Down switch the LCD screen changes and the cursor moves to the next menu Status With the cursor on the menu Status push the Down switch the cursor moves to the Test menu From the above screen push the Down switch The cursor moves to the Function Setting menu changing the LCD screen DKT A S Fanoevej 6 13 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 In this condition MAIN MENU is finished 4 2 2 Provision menu User is able to control the operational state of the EDFA in the Provision menu It is the menu for selecting activate ACT and deactivate DEACT operational states of the EDFA E Provision menu LCD display is changed to the next screen
44. p ARG1 ARG2 ARG3 ARGI get set ARG2 rocomm Read Only Community rwcomm Read Write Community trap Trap Receiver Index Select trapen Trap Enable trapcomm Trap Community ver Version Select admintype ADMIN authentication Type SNMP V3 usertype USER authentication Type SNMP V3 adminkey ADMIN account MD5 SHA Key userkey USER account MD5 SHA Key ARG3 rocomm String Limit 2 10 wecomm String Limit 2 10 trap Index Number 1 5 trapen Indax Number 1 5 trapcomm Index Number 1 5 ver Version Select Number 0 2 0 SNMP V1 V2c 1 SNMP V3 2 SNMP V1 V2c V3 admintype Type Select 1 3 usertype Type Select 1 3 1 NONE 2 MD5 3 SHAI adminhey String Limit 2 10 userkey String Limit 2 10 ARG4 trap Trap Receive IP XXX XXX XXX XXX trapcomm String Limit 2 10 trapen String ON OFF SNMP GET TRAP Index ex ADMIN gt snmp get trap 1 SNMP Trap IP 1 92 168 0 31 SNMP GET ROCOMM ex ADMIN gt snmp get rocomm SNMP Read Only Community public SNMP GET RWCOMM ex ADMIN gt snmp get rocomm SNMP Read Only Community public SNMP GET TRAPEN Index ex DKT A S Fanoevej 6 28 DK 4060 Kirke Saaby Tlf 45 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 201
45. problem using the technical information provided The expert should follow the steps below which may fix the problem or recover the operational state Any other repair attempts except those explained in this chapter may cause unexpected damage or problems to the unit or installation Careful treatment and caution is required for all trouble shooting procedures 72 Trouble Shooting Procedures When an operator recognizes any problem on the EDFA front panel he she should try to identify the type of problem When the problems occur the symptoms are shown below Table Table 10 In the cases alarm events and Alarm LEDs signs Case Laser Status Garces LED LED 1 Off Off Electric power is not provided 2 Red Red The optical input power of the EDFA does not meet the minimum requirement 3 nem Red The optical output power of the EDFA does not meet the specified output power The bias current of the Pump Laser Diode of the EDFA is abnormal 4 Green Xelow i Case Temp is out of the specified range FAN fail 5 Green Yellow The internal temperature of the Pump Laser Diode of the to Red toRed EDFA is out of the specified range M Case 1 Check the power switch and power cord so that electric power is provided properly M Case 2 Measure whether the optical input power of the EDFA from the optical source or optical transmitter satisfies the minimum optical input power condition of the EDFA If the
46. r Interface can be established for remote control and monitoring Read Only Community Accounts for general users like operators who are not allowed to modify configurations Identical to USER account in CLI Read Write Community Accounts for system administrators who can modify product configurations Identical to ADMIN in CLI Trap IP IP address for Trap Receiver which receives alarm information in an event of alarm activation Up to 5 Trap IP can be assigned Trap Enable Enable alarm transmission to Trap IP Assign Trap IP before Trap Enable Trap Community The community name to be used by the device when sending traps Factory Default Item sub command Default Value RO community ROCOMM PUBLIC RW community RWCOMM PRIVATE Trap IP TRAP 0 0 0 0 Trap Enable TRAPEN OFF 31 DKT A S Fanoevej 6 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier OFA CCS CCD Series User s Manual Rev 1 3 5 2 June 2014 SNMP MIB Table 52 1 entPhysicalEntry entityMIB OID 1 3 6 1 2 1 47 Name OID Type Access E T C entPhysicalIndex 1 3 6 1 2 1 47 1 1 1 1 1 x Integer32 RO entPhysicalDescr 1 3 6 1 2 1 47 1 1 1 1 2 x octets RO entPhysicalClass 1 3 6 1 2 1 47 1 1 1 1 5 x Integer32 RO entPhysicalName 1 3 6 1 2 1 47 1 1
47. reshold value information ALARM HIHI 24 0 dBm ALARM HI 23 0 dBm ALARM LO 10 0 dBm ALARM LOLO 9 0 dBm BIAS and TEMP alarm threshold value information of LD LD NO 1 BIAS ALARM HIHI 700 mA TEMP ALARM HIHI BIAS ALARMHI 700 mA TEMP ALARM HI BIAS ALARMLO 0 mA TEMP ALARM LO BIAS ALARM LOLO O mA TEMP ALARM LOLO 4 LD NO 2 BIAS ALARM HIHI 680 mA TEMP ALARM HIHI BIAS ALARMHI 680 mA TEMP ALARM HI BIAS ALARMLO 0 mA TEMP ALARM LO BIAS ALARM LOLO 0 mA TEMP ALARM LOLO LD NO 3 BIAS ALARM HIHI 1261 mA TEMP ALARM HIHI BIAS ALARMHI 1261 mA TEMP ALARM HI BIAS ALARMLO 0 mA TEMP ALARM LO BIAS ALARM LOLO 0 mA TEMP ALARM LOLO LD NO 4 BIAS ALARM HIHI 1298 mA TEMP ALARM HIHI BIAS ALARM HI 1298 mA TEMP ALARM HI BIAS ALARMLO 0 mA TEMP ALARM LO BIAS ALARM LOLO O mA TEMP ALARM LOLO 27 DKT A S Fanoevej 6 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 5 1 1 12 SNMP Before SNMP interface connection a few preliminary setups need to be done SNMP interface requires Read Only Community and Read Write Community to be set up For Trap set up Trap IP Trap Community and Trap Enable Disable need to be defined beforehand See below for examples ex ADMIN gt snmp Usage snm
48. rke Saaby Tlf 445 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier OFA CCS CCD Series User s Manual Rev 1 3 June 2014 2 PREPARATION 2 1 Summary In this chapter the first steps of installation after unpacking are covered The box inventory basic electrical and optical connections are presented 2 2 Check the Contents After unpacking you need to check the contents The inventory should be as follows Table 1 The Inventory of Shelf Type EDFA Item Quantity Remarks EDFA Shelf 1 Including EDFA Instructions manual 1 book TEST REPORT 1 booklet Inspect the outside of the EDFA WARNING Remember to take all proper grounding precautions 2 3 How to Connect the Power Supply Figure 1 shows the electrical connectors with the input power terminals on the front panel of the Shelf Type EDFA The user must select the applicable power connections for their application and properly connect to the input power terminal TRIAL 283 FUSE P E Pa N pew gt 7 fo CRY 1 AT NY 7 DC a 1U Shelf i5 oO Pa f 100 244 H2 24 l s Iu 7 2 J DC AC b 2U Shelf Figure 1 Electric Power Supply Connection DKT A S Fanoevej 6 7 DK 4060 Kirke Saaby TIf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User
49. s the circumstances that occur when the Shelf Type EDFA is first powered up Check if the Power Switch on the front panel is in the OFF state Connect power cords to the power sockets on the rear panel Turn on the Power Switch on the front panel All the LED s on the front panel turn on The LCD on the front panel shows the Start state When the Start state of LCD ends all the LED s on the front panel turn off and the related LED s turn on W Ifthe optical input power is normal the EDFA stays in the Laser ON state 6 3 Primary Test 6 3 1 Required Measuring Instruments The required measuring instruments and their performances for the Primary Operation of the EDFA are in Table 10 Table 9 The Instrument for measuring the performance Instrument Performance Optical Source or Optical Transmitter Input Optical Signal Source to the EDFA Operational wavelength 1550nm substitution Optical Variable Attenuator Controls the optical input power Optical Power Meter Measure the optical power 6 3 2 Performance Test Precaution Before this test you must insure the conditions below are met 1 You must always keep clean the surface of the optical connectors 2 Do not look directly into the optical connector 3 Do not wipe the surface of the optical connector during the LASER ON state of the EDFA DKT A S Fanoevej 6 45 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com W
50. tical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 Table 7 Provision Menu Descriptions ACT State DEACT State EDFA normal operation Status LED Green Alarm information is not detected EDFA normal operation 4 2 3 Control In the Control Menu the optical output power of the EDFA can be controlled by Laser ON or Laser OFF Also you can select the Buzzer sound in the Buzzer Control menu From the MAIN MENU using the Menu switch move the cursor to the Control If you push Enter switch the cursor moves to the LASER menu M Laser ON From the below screen the first line indicates the current selected laser state of the EDFA If you want to select a different state from your current laser state using the Up or Down switch move the cursor to the menu that contains the state you wish to select To activate the output of the EDFA normally put the cursor on the LASER ON position Push the ENTER Switch Laser Key switch is ON state If the Laser Key switch is OFF state Laser On Off is not changed it remains the same state Push Enter or Menu switch If you want to turn off the output of the EDFA push the Enter switch to move the cursor to the OFF position DKT A S Fanoevej 6 15 DK 4060 Kirke Saaby TIf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CC
51. tion ip IP address Key information for Telnet SNMP or TCP IP connection subnetmask Subnetmask address Key information for Telnet SNMP or TCP IP connection gateway Gateway address Key information for Telnet SNMP or TCP IP connection reset Reset to factory default setup Reset the network connection due to network reconfiguration or any other network connection problems Operation of optical amplifier is not affected by this command mpu Main Process Unit configuration as well as setup view and confirmation ofau OFAU Optical Fiber Amplifier Unit amplifier module in side shelf type EDFA or amplifier module card for rack type EDFA configuration as well as setup view and confirmation snmp SNMP configuration as well as setup view and confirmation Command Execution Privilege command ADMIN USER ver O O cls Oo O ping O O logout Oo O ip Read Write Read Only subnetmask Read Write Read Only DKT A S Fanoevej 6 21 DK 4060 Kirke Saaby Tif 45 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 gateway Read Write Read Only reset Oo O mpu Read Write Read Only otu Read Write Read Only ofau Read Write Read Only snmp Read Write Read Only shelf Read Write Read Only ntp Read Write Read Only 5 1 1 1 VER Software version
52. umber 201204030001 Firmware Version 2 00 Hardware Version 2 50 OFAU GET STATUS View OFAU current status ex ADMIN gt ofau get status OFAU Slot Number 1 EDFA Alarm Status Bit 0x18 Operation Mode 44 Case Temp 28 C Input Power XX XX dBm Number of Optical Output Port 8 Output Power of port No 1 XX XX dBm Output Power of port No 2 XX XX dBm Output Power of port No 3 XX XX dBm Output Power of port No 4 XX XX dBm Laser Alarm Status Bit 0x0 LD 1 gt Bias O mA Temp 25 C DKT A S Fanoevej 6 26 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 445 4646 2625 E mail mail dktcomega com Web www dktcomega com T Network Managed Optical Amplifier OFA CCS CCD Series User s Manual Rev 1 3 June 2014 LD 2 gt Bias O mA Temp 25 C LD 3 gt Bias 3 mA Temp 24 C LD 4 gt Bias O mA Temp 25 C OFAU GET CONFIG View OFAU configuration ex ADMIN gt ofau get config OFAU Slot Number 1 OFA input 5V Low Limit 4 7 V OFA input 5V High Limit 5 3 V Input Power Minimum 12 5 dBm Input Power Maximum 13 0 dBm Output Power Minimum 0 0 dBm Output Power Maximum 25 1 dBm Reference Output Power 20 9 dBm IPM alarm threshold value information ALARM HIHI 13 0 dBm ALARM HI 12 0 dBm ALARM LO 10 0 dBm ALARM LOLO 11 0 dBm OPM alarm th
53. une 2014 5 3 4 Control set This page allows for various control settings to be adjusted via the convenient WEB GUI Only the ADMIN account user can access this page Optical Amplifier mwono c B A nze99 Fo uma og sz es sme Value setting Control Monitoring Parameter on on Control set Event Log IP amp Login set SNMP set Manual i couetOutpulPower 7 18 0 dim DKT A S Fanoevej 6 40 DK 4060 Kirke Saaby Tlf 445 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 5 3 5 Event log The Event Log page will display all of the recorded events during the optical amplifier s operation Up to 200 events are recorded and shown in this page The event log page is accessible through all the user levels DR EE TE B operei nea cum HEN BAR SR NSS Monitoring Parameter Control set Event Log SNMP set Manual 20131210161729 20131210161717 20131014130320 19131014150320 DKT A S Fanoevej 6 41 DK 4060 Kirke Saaby Tif 45 4646 2626 Fax 45 4646 2625 E mail mail dktcomega com Web www dktcomega com Network Managed Optical Amplifier User s Manual Rev 1 3 OFA CCS CCD Series June 2014 5 3 6 IP amp Login set IP Subnet mask and Gateway addresses can be set via this page Passwords for Admin and User accounts can be set A syst
Download Pdf Manuals
Related Search
Related Contents
Administrator Manual for Campus Post It Website Template System 10-770型 取扱説明書 ビルトインコンロ SYSMAC CS/CJ-series CS1W-PRM21/CJ1W-PRM21 Einhell TH-TS 1525 U Monte Carlo Fan Company 5-Mar-52 User's Manual 1/3” Tag/Nacht-Domekamera mit Pixim-Technologie VKCD Samsung CE137NEM-X Uživatelská přiručka Ground Loop Design: Residential Edition PIANO Reference Manual Python Interface for Assimilation in NemO Copyright © All rights reserved.