1. Reject with means that the filter will drop the input packet and send back a reply packet according to any of the reject types listed below ICMP network unreachable alias ICMP host unreachable alias ICMP port unreachable alias ICMP protocol unreachable alias ICMP network prohibited alias ICMP host prohibited alias Echo reply alias TCP RST packet alias Note The packets are matched using tcp flags and appropriate reject type with the REJECT target Host Table The Host Table form enables you to keep a table of host names and IP addresses that comprise your local network and thus provide information about your network environment To Configure The Host Table 1 Select Network gt Host Table The system invokes the Host Tables form Web Manager for Administrators 95 Configuring the ACS in Expert Mode Host Settings Syslog PCMCIA Management 192 168 160 10 CAS VPN Connections Static Routes Figure 4 31 Host Table Form 2 To edit host select the host IP address from the Host Table and then click on the Edit button If the list is long use the Up and Down buttons to go through each item in the list OR 3 To add a host click the Add button 4 The system brings up the New Modify Host dialog box e New Modify Host Microsoft Internet Explorer ox IP Address 127 D 0 1 Name localhost Figure 4 32 5 Type in the new or modified host address in the IP Add
2. 3 After entering a new chain name click on the Edit Rules button to access the next dialog window to enter the rules for that chain Select OK to commit your changes To add rules to your new chain proceed to the Adding a Rule section Editing a Chain 1 To edit a chain select from the view table the chain you wish to edit and then select the Edit button AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode The system brings up the Edit Chain dialog box 3 Edit Chain Microsoft Internet Explor Name INPUT Policy ACCEPT ha 2 Modify the Policy field as necessary and then select the OK button 3 If you need to edit any rules for this chain proceed to the Editing a Rule section Deleting a Chain Only user defined chains can be deleted The system will not allow you to delete a built in chain 1 From the Firewall Configuration form select the chain you wish to delete from the list and then select the Delete button Editing a Rule The rules define how the filtering should work To edit a rule choose from the Edit Rule dialog box the target policy Accept Reject Log Return Drop and the packets you want to filter source destination IP Ethernet interface and protocol type if it applies to fragments Any of the items i e source destination IP input output interface can be inverted by checking the Inverted check box To invert means rules will apply to everything e
3. Master Unit Software Version 1 1 00 Update First Slave Software Version 1 2 1 Figure 4 20 Power Management Software Upgrade Form 3 Select the Refresh button to ensure that all software information on the form is up to date 4 From the Software Version list select the software you wish to update and then select the Update button to the right of the listed version 5 Select the apply changes button at the bottom of the configuration window to save your configuration Terminal Profile Menu The Terminal Profile Menu form enables you to create a menu of commands for users to use whenever ACS is used as a terminal server with dumb Web Manager for Administrators 65 Configuring the ACS in Expert Mode terminals attached The menu should appear when users turn on the dumb terminal and login to ACS You can create any valid command recognized by the ACS operating system The most common use of this feature is to launch an SSH session to a host system 1 From the top menu bar select Applications from the menu panel select Terminal Profile Menu The system invokes the Terminal Profile Menu form Applications Connect Menu title Power Management Menu Options Figure 4 21 Terminal Profile Form 2 To edit a menu option select the action name from the table and then click on the Edit button OR To add a new menu option to an existing menu click on the Add button 66 AlterPath Advanced Co
4. Appendix B Outlines the Safety Considerations for installing and handling the ACS Appendix C Lists the latest Web Browsers that ACS supports and explains the procedure for installing JRE on your PC AlterPath Advanced Console Server July 2005 Glossary Contains a glossary of terms and acronyms used in the manual Index Index of keywords or subjects Related Documents The following documents for the Cyclades AlterPath ACS is shipped with the product e AlterPath ACS Quick Start Guide hard copy e AlterPath ACS Advanced Administration Guide Updated versions of this document will be posted on the downloads section of the Cyclades website in the AlterPath ACS section when Cyclades releases new versions of the software A hard copy version of this document can be ordered under part number PAC0379 through your Cyclades sales representative Typographical Conventions Form Window labels Words that appear on forms windows or any part of the user interface are typed in boldface Examples The Add User dialog box the Password field Hypertext links With the exception of headings and the Table of Contents which are already linked all underlined words are hypertext links Important words For emphasis important words are italicized Menu selections The order in which you select a menu is indicated by the greater than symbol gt Example Network gt Access Method Screen words Words that appear as
5. The dialog box for configuring the PCMCIA card will have varying sets of input fields depending on the type of PCMCIA card that you select from the drop down box Access Method Modem If the selected card type is Modem default the following fields are used y Slot 1 Microsoft Internet Explorer mm x ox w rele Modem y PPP Local IP Remote IP M Call Back Phone Number fa Table 4 16 Form Fields for a PCMCIA Modem Card Field Name Definition PCMCIA Card Pull down box to select the type of PCMCIA card that you are using PPP Check box to enable point to point protocol AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Table 4 16 Form Fields for a PCMCIA Modem Card Field Name Definition Local IP The local IP address of the PCMCIA card Remote IP The remote IP address of the PCMCIA card Call Back Check box to enable the callback security feature Phone Number The phone number that the ACS uses to call back Access Method ISDN If the selected Access Method is ISDN the following fields are used 5 5 El ISDN gt Local IP 10 0 0 21 Remote IP 10 0 0 22 M Call Back Phone Number 8358 662 iol x E Table 4 17 Form Fields for an ISDN Card Field Name Definition PCMCIA Card Select ISDN from the pull down box PPP Check box to enable point to point protocol Local IP The local IP a
6. IP Address of the PC or terminal AlterPath ACS NameServer and Gateway Network Access Java 2 JRE You will need Root Access on your local UNIX machine in order to use the serial port If you are using a PC ensure that HyperTerminal is set up on your Windows operating system If you have a UNIX operating system you will be using Kermit or Minicom You will need to locate the IP address of your PC or workstation the ACS and the machine that resolves names on your network Your Network Administrator can supply you with these If there is outside access to the LAN that the ACS will be connected with you will need the gateway IP address You must have a NIC card installed in your PC to provide an Ethernet port and have network access You must have Java 2 Runtime Environment JRE version 1 4 2 which can be found at http java sun com installed on your PC with your browser acknowledged to use it AlterPath Advanced Console Server July 2005 Installation and Configuration Process Ensure that the browser you are using acknowledges the Java version by following the procedures given in Appendix C Supported Browsers and JRE Installation and Configuration Process The installation and configuration process is divided into six distinct tasks e Install ACS and connect to the network e Configure the network parameters using the console port e Configure ACS using the Web Manager in Wizard Mode e Test C
7. Installation and Configuration Process 20 AlterPath Advanced Console Server July 2005 Chapter 3 ACS for Regular Users This chapter presents the methods for accessing serial ports and the basic operations for using ACS Addressed to the ACS end user the chapter is divided into the following topics Using the Web Manager Using the Command Line Interface CLI Using Telnet Using the TS Menu Power Management Using the Web Manager Using the Web Manager Note Refer to Appendix C for a description of the web requirements for connecting to a serial port To use the Web Manager to connect to a serial port follow the following procedure 1 Connect your web browser to the ACS by typing in the Console Access Server s IP address e g https 10 10 10 10 provided to you by your system administrator in the address field of your internet browser 2 Press Enter The system brings up the ACS Web Manager Login Window Login username m password ooo ieoi Figure 3 1 Web Manager Login Window 3 To log in type in your username and password as provided to you by your system administrator The system brings up the Port Selection form 22 AlterPath Advanced Console Server July 2005 Using the Web Manager Power Management Security Connect to ACS tstl Figure 3 2 Port Selection Window 4 To connect to a port by default the radio button is already selected for connecting to P
8. Select the available COM port number from the Connection dropdown list box Configure COM port using the following parameters e Serial Speed 9600 bps e Data length 8 bits e Parity None e Stop bit 1 Flow control None Power on the ACS After the initial startup scripts the login prompt appears Note If your ACS model is equipped with dual power supplies make sure you turn both power switches on After system initialization a beep sound may warn if one of the power supplies is off 5 Connect the COM Port to the ACS Console Login as root and enter the default password tslinux Caution Changing the default password closes a security hole that could be easily expolited It is strongly recommended to change the root password before setting up the ACS for secure access to the ACS equipment 6 Le Installing the ACS To Change the root password Enter the passwd command and enter a new password when prompted The following Security Advisory appears the first time ACS is accessed IMPORTANT Security Advisory Console Management provides critical access to management features of attached equipment Please take the required precautions to understand the potential impacts this device may have to your SECURITY policies Installation and Configuration Process From factory this device is configured as follows e Single password for ROOT e All serial ports DISABLED DHCP Telnet SSHv1
9. VPN 81 Authentication Protocol VPN 81 Authentication Type AlterPath Advanced Console Server User Manual 171 Kerberos KerberosDownLocal 114 NIS LocalNIS or NISLocal 114 B Backup and Restore Procedure 137 Backup Configuration form 135 Baud Rate 45 Bonding 70 155 miimon 70 updelay 70 Boot Configuration 133 boot from network 133 boot settings 133 brackets mounting 9 Buffer to Syslog 115 Button Functions 36 C Chain 87 Changing a User Password 47 Changing the User Password 101 Clear Max Detected Current 61 Clear Max Detected Temperature 61 Closing the session from ts_menu 26 COM port 15 Compact Flash 74 Configure PCMCIA Cards 72 Configure the Security Settings 40 Configure User Access to Serial Ports 46 Configure VPN Connections 80 Configuring in Expert Mode 53 Connecting to a port 56 Connection Protocol Port Profile 45 Console Access Profile CAS 43 console port 172 AlterPath Advanced Console Server User Manual D Data Buffering 106 115 Data Size Port Profile 45 DB 9 connector 8 Deleting a Chain 89 Deleting a Slave 122 124 Deleting a User from a Group 101 Deleting a User Power Management 63 Deleting a User Wizard Mode 49 DHCP network settings 68 document related documentation vii Documentation CD 6 E edit 80 Edit Rule dialog box 90 Editing a Chain 88 Editing a Rule 89 Email Notification 127 Enable Data Buffering Ports configuration 115 escape character 26 Ethernet 8 74 Exp
10. amp SSHv2 and HTTP HTTPS enabled Cyclades strongly recommends 1 To change the root password before setting up the box for secure access to the ACS equipment See Chapter 2 To Install ACS and Connect to the Network 2 To select a Security Profile to complete the INITIAL SETUP Security is dependent on Policy and is Configurable to fit in environments with varying levels of Security Cyclades provides three pre set Security Levels SECURED MODERATE and OPEN and in addition the ability to seta CUSTOM Security Profile For details on selecting and configuring a Security Profile see Chapter 4 Configuring the ACS in Wizard Mode For configuring using CLI see ACS Advanced Administation Guide 3 Do not leave the equipment idle WITHOUT selecting a Security Profile 4 To enable Serial Ports and configure them using the Web Manager see Chapter 4 Port Profile For configuring using CLI see ACS Advanced Administration Guide 8 Launch the Configuration Wizard by entering the wiz command As shown in the sample screen below the system brings up the configuration wizard banner and begins running the wizard 16 AlterPath Advanced Console Server July 2005 Installation and Configuration Process Installing the ACS is HAHAHAHA C 0 N F I 6 U R A T I 0 N WW I Z A R D HE EE EEE Des Current configuration Hostname CAS DHCP disabled System IP 192 168 48 11 Domain name cyclades com Pr
11. and vice versa To add a user or edit an assigned user perform the following steps 1 From the top menu bar select Applications from the left menu panel select Power Management from the tabs select Users Manager The system brings up the Users Manager form Web Manager for Administrators 61 Configuring the ACS in Expert Mode Applications Connect Users Manager Terminal Profile Menu Serial Port 2 Users Information Figure 4 18 Power Management Users Manager Form 2 To edit an assigned user select the user you wish to edit from the Serial Port view table and then select the Edit button that corresponds to the table OR To add or assign a new user select the Add button from the appropriate Serial Port view table The system brings up the Add Edit User dialog box 62 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode User Outlets 3 From the Add Edit User dialog box modify or enter in the corresponding fields the user and the outlets to which the user is assigned and then select the OK button Note Jn the Outlets field use the comma to separate each outlet use the hyphen to indicate a range of outlets e g 1 3 6 9 12 Selecting Edit will not allow you to edit or delete the user only the outlet assignments for that user 4 Verify your entry by checking the appropriate Serial Port table from the Users Manager form 5 Select the apply change
12. la tapa abierta precauci n Para prevenir un corto circuito en el AlterPath Advanced Console Server al desconectarlo de la red primero desconectar el cable del equipo y luego el cable que conecta a la red Para conectar el equipo a la red primero conectar el cable a la red y luego al equipo precauci n Asegurarse que el equipo este conectado a tierra para prevenir un shock el ctrico El cable el ctrico del equipo viene con tres clavijas para conectar asegurar conexi n a tierra No use adaptadores o quite la clavija de tierra Si se tiene que utilizar una extensi n utilice una que tenga tres cables con clavija para conexi n a tierra Para proteger al AlterPath Advanced Console Server de fluctuaciones en corriente el ctrica utilice una fuente el ctrica de respaldo Asegurarse de que nada descanse sobre los cables del AlterPath Advanced Console Server y que los cables no obstruyan el paso Asegurarse de no dejar caer alimentos o bebidas en el AlterPath Advanced Console Server Si esto ocurre avise a Cyclades Corporation precauci n No empuje ning n tipo de objeto en los compartimientos del AlterPath Advanced Console Server Hacer esto podr a ocasionar un incendio o causar un corto circuito dentro del equipo precauci n Mantenga el AlterPath Advanced Console Server fuera del alcanc de calentadores y asegurarse de no tapar la ventilaci n del equipo precauci n El AlterPath Advanced Console Ser
13. you don t have any JRE installed in which case please install and repeat the check AlterPath Advanced Console Server July 2005 If you have already installed JRE and you just want to activate your browser to use it go to your system s Control Panel gt Java Plug in icon gt Browser gt check on the browser s you want to activate to use the Java Plug in Now repeat the check to see if your browser will now use the correct Java Plug in Installing From Windows Netscape or Mozilla Check to see if Java is enabled Go to Edit gt Preferences gt Advanced gt Check on Enable Java To see what version of JRE Plug in is used go to Help gt About Plug ins Scroll down to Java Plug in section Check if the Java Plug in is the version you have installed TIP When installing Netscape 7 0 it will ask if you want to install Sun Java If you click on the box to install it a version of JRE will be installed into your system however this does not mean that other browsers such as IE will recognize it If you choose not to install Sun Java through Netscape but do it separately Netscape 7 0 should automatically detect the JRE and this can be checked by the instructions mentioned above Supported Browsers and JRE 153 154 AlterPath Advanced Console Server July 2005 Glossary Authentication Basic In Out System BIOS Baud Rate Bonding Linux The process by which a user s identity is checked within the network to ensure
14. 10 AlterPath Advanced Console Server July 2005 System Requirements System Requirements To configure the ACS Cyclades recommends any of the following hardware specifications e Workstation with a console serial port or e Workstation with Ethernet and TCP IP topology or e Cyclades AlterPath Manager The following table lists the hardware connectivity required for each configuration method Hardware Connectivity Configuration Method Workstation Hub Ethernet Cables Web browser vi Wizard or CLI Console Console Cable constructed vi Wizard or CLI from RJ45 straight through cable adapter Workstation Hub Ethernet Cables Note This manual is designed primarily for Web Manager users If you use vi the wizard CLI version or CLI refer to the ACS Advanced Administration Guide Note To install ACS with AlterPath Manager refer to the AlterPath Manager Manual and configure the device using the AlterPath Manager Installing the ACS 11 Default Configuration Parameters Default Configuration Parameters DHCP enabled if there is no DHCP Server IP for Ethernet is 192 168 160 10 with a Netmask of 255 255 255 0 e CAS configuration e Socket_server in all ports access method is telnet e 9600 bps 8N1 No Authentication Pre Install Checklist Before you install and configure the ACS ensure that you have the following 12 Root Access HyperTerminal Kermit or Minicom
15. 7001 FT Windows EMS TCP Keep alive 1000 a Interval 1000 Idle Timeout jo STTY Options Break Interval 500 a Login Banner Welcome to Console Server Management Server 3h port 3 p xl v Selected ports all Done Figure 4 46 Physical Ports Form Other Tab 2 From the above form complete the following fields as necessary Table 4 36 Physical Ports From Fields Other Tab Field Name Definition Port IP Alias The IP alias of the selected port TCP Port The TCP Port number Port Name As indicated AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Table 4 36 Physical Ports From Fields Other Tab Field Name Definition Windows EMS Checkbox to enable Windows EMS Expanded Memory TCP Keep alive Interval Specifies the time interval between the periodic polling by the system to check client processes and connectivity Idle Timeout The maximum time in seconds that a session can be idle before the user is logged off STTY Options Set terminal options Break Interval Break interval in milliseconds Login Banner Text entry field box Enter the text you wish to appear as a login banner upon logging onto the terminal Host to Connect Address of the host connected to the port Terminal Type As indicated Modem Initialization Text entry field box PPP Options Options when using this protocol Virtual Ports You can use one ACS as a Master to control o
16. Console Server July 2005 Power Management suspend telnet send break toggle binary exit telnet DON 2 Press e to exit from the session and return to the original menu Select the exit option and you will return to the shell prompt Closing the session from ts_menu From Telnet You have to be sure that a different escape character is used for exiting your telnet session otherwise if you were to exit from the session created through the ts_menu you will close your entire telnet session to your unit To do this when you first telnet to your unit use the e option Example to set Ctrl as the escape character type telnet e 192 168 160 10 To exit from the session created through the ts_menu just follow Step 1 from above To exit from the entire telnet session to your unit type the escape character you had set From SSH If you use SSH to make the first connection to the ACS then the escape character for each session becomes tilde tilde period Power Management The Power Management forms Power Management gt Outlets Manager or View IPDUs Info allows you to manage the power outlets on the Cyclade s AlterPath PM family of Intelligent Power Distribution Units IPDUs or view information about the IPDUs connected to the ACS The Outlets Manager form is used to power the remote machines on and off check the status and lock the power outlet in the on or off state to prevent accidental
17. Figure 4 43 Data Buffering Form 2 Complete the necessary fields as follows Table 4 33 Data Buffering Form Fields Field Name Definition Destination Select whether the destination of the data buffer is Local or Remote Web Manager for Administrators 115 Configuring the ACS in Expert Mode 116 Table 4 33 Data Buffering Form Fields Field Name Definition Mode Full Size Bytes Record the timestamp Show Menu Syslog Server Facility Number Syslog Buffer Size Select whether the Buffering Mode is Linear sequential or Circular non sequential The maximum limit of the data buffer Commands the system to include a timestamp in the data buffering file Indicates the menu type for viewing the buffer Select from Show all options No Show data buffering file only and Show without the erase options The IP address of the Syslog Server Facility or location ID of the Syslog Server Maximum size of the buffer By selecting the appropriate radio button you can configure ACS to Buffer Syslog at all times Buffer only when nobody is connected to the port Note To configure data buffering to send alarm notifications use the Notifications form Expert Mode Administration gt Notifications 3 When done select the apply changes button located at the bottom of the ACS configuration window Multi User The Multi User form enables you to open more than on
18. File Version The firmware file version Run Checksum Runs the checksum program to verify the accuracy of the uploaded data 3 Click on Upgrade Now Web Manager for Administrators 139 Configuring the ACS in Expert Mode Reboot The Reboot form allows you to reboot the system by clicking the Reboot button Administration pee System Information MA This administration tool will reboot the system Time Date Boot Configuration Backup Config Upgrade Firmware Figure 4 59 Reboot Window 140 AlterPath Advanced Console Server July 2005 Appendix A Hardware Specifications The following table lists the AlterPath Advanced Console Server hardware specifications CPU MPC855T PowerPC Dual CPU Memory 128MB DIMM SDRAM 16MB CompactFlash Interfaces 1 Ethernet 10 100BT on RJ45 1 RS232 Console on RJ45 RS232 Serial Ports on RJ45 PCMCIA slots supporting Secondary Ethernet Wireless networking CDMA GPRS GSM V 90 modems ISDN Power Internal 100 240VAC 50 60 Hz Optional Dual entry redundant power supplies 48VDC option available Operating Temperature 50 F to 112 F 10 C to 44 C Storage Temperature 40 F to 185 F 40 C to 85 C Humidity 5 to 90 non condensating Dimensions ACS1 6 3 x 4 0 x 1 5 in 16 x 10 x 3 8 cm ACS 4 48 17 x 8 5 x 1 75 in 43 18 x 21 59 x 4 45 cm Certification FCC Part 15 A EN55022 A CE EN55024 UL 1950 Solaris Ready 142 AlterP
19. Form Title Use View IPDUs Info View IPDU information by ports and slaves The information form provides real time global current monitoring of all connected devices Users Manager Add or delete users assigned to specific outlets Configuration Enable over power protection syslog and alarm notification from any specified port The form allows you to set a current alarm threshold that once exceeded will have the ACS sound an alarm or send a notification message Software Upgrade Upgrade power management software You can configure the port assignments of the IPDU units including the user and group access using the Power Management form of the Ports menu Ports gt Physical Ports gt Power Management Outlets Manager The Outlets Manager form allows you to check the status of all IPDUs connected to the Console Server including their outlets Any user who has Administrative privileges can turn on turn off cycle lock and unlock the outlets 1 From the top menu bar select Applications from the left menu panel select Power Management The system invokes the following form 58 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Applications Connect Outlets Manager Terminal Profile Menu ononon nge linuxser Mail myoutlet outs LinuxServer out a2 e a a 0000000 ED ED ED BD ED ED ED ED IA Figure 4 15 Power Management Form 0 50 0 50 0 50
20. Security Profile Step 2 Network Settings aes ee Add users who will be able to access all ports Step 3 Port Profile By default all users can access all ports See Help for more details Step 5 Data Buffering Step 6 System Log Figure 4 9 User Access Setup 2 To complete your User Access configuration proceed to the appropriate subheadings of this section Changing a User Password Adding a User or Deleting a User 46 AlterPath Advanced Console Server July 2005 Configuring the ACS in Wizard Mode v To Change a User Password Note If you havent changed your root administration password now is the time to change it using the Change User Password dialog box 1 From the Users scrollable field box of the Access window select the user whose password you want to change and then click the Change Password button The system brings up the Change User Password dialog box http 192 168 48 11 Change User P a Ea pl New Password Repeat a New Password Figure 4 10 Password Change Dialog box 2 Type in the new password in the two entry fields of the dialog box and then click on the OK button v To Add a User 1 If you haven t opened the Access form select Step 4 Access from the menu panel The system brings up the Access form 2 From the Access form select the Add button The system brings up the Add User dialog box Web Manager for Administrators 47 Configuring the ACS in W
21. The password used to authenticate messages sent between the SNMP client and the router containing the SNMP server Source The IP addresses or the range of source IP address OID Object Identifier Permission Select the permission type e Read Only Read only access to the entire MIB except for SNMP configuration objects e Read Write Read write access to the entire MIB except for SNMP configuration objects e Admin Read write access 3 If you are adding or editing an SNMP agent using SNMPv3 scroll down to the lower half of the SNMP Configuration form 10XXXXXXXXXXXXXXXXXX XXX XXX XXX XXX XX XX XX XX XX XX SNMPv3 Configuration 1xx z ZXXKXXXXXXXXXXXXXXXXX IXXXXXXXXXXXXXKKKXKKXX AXXXXXXXXXXXXXXXXXXX 5XXXXXXXXXXXXXKKKXKXX KXXXXXXXXXXXXXXXXXXX TXXXXXXXXXXXXXKXKXXXX B XXXXXXXXXXXXKXKXKKXXKXKX OXXXXXXXXXXXXXXXKKKK Read write Read write Read write Read write Read write Read write Read write Read write Read write 4 To Add an SNMP agent using SNMPv3 Configuration Web Manager for Administrators 85 Configuring the ACS in Expert Mode 86 select the Add button located at the bottom of this view table OR To edit an SNMP agent select the Edit button The system invokes the New Modify SNMP v3 Configuration dialog box Z New Mod SNMP 3 C ok cance Her User name Password OID Permission Read Only Figure 4 28 5 Complete the form and select the OK butt
22. a serial port enter the following command telnet lt hostname or IP address gt lt TCP port number gt Press ENTER Where lt hostname gt is the hostname configured in the workstation where the telnet client will run through etc hosts or DNS table Or it can just be the IP address of the ACS Ethernet s interface as configured by the administrator or as learned from DHCP lt TCP port number gt is the number associated to the serial port The factory default values 7001 corresponds to serial port 1 7002 to serial port 2 and so forth and 3000 is a pool with all serial ports To close the telnet session just press the telnet hot key configured in the telnet client application usually it is Ctrl SSH Access Secure Shell SSH is a command interface and protocol often used by network administrators to connect securely to a remote computer SSH replaces its non secure counterpart rsh and rlogin There are two versions of the protocol ssh v1 and ssh v2 The AlterPath Console Server offers both To open an ssh session to a serial port or the next free serial port from a pool issue the command ssh 1 lt username gt lt server gt lt hostname or IP address gt Where lt username gt is the user configured to access that serial port It is present either in the local CAS database or in a Radius Tacacs LDAP Kerberos etc database lt Server gt can be just the TCP port number assigned for that serial port 7001
23. appendix e AlterPath ACS supported browsers e Jave Runtime Environment JRE requirements e JRE installation procedures e Using Windows and Internet Explore browser e Using Windows and Netscape or Mozilla browsers 152 Supported Web Browsers The web browsers that support the AlterPath Console Server web interface are as follows e Netscape 7 1 for Windows e Mozilla 1 3a for Windows e MS Internet Explorer 6 0 Browsers that do not support the ACS web interface e Netscape Communicator 4 8 e Netscape Communicator 4 79 Installing JRE Tested Environments e Windows XP JREv1 4 2 e Internet Explorer 6 0 Successful e Netscape 6 0 6 2 3 Successful e Netscape 7 0 7 1 Successful e Mozilla 1 1 1 3a Successful Installation Requirements For the ACS application to run you must have Java 2 Runtime Environment JRE version 1 4 2 which can be found at http java sun com installed on your PC with your browser acknowledged to use it You can first check if the browser you are using acknowledges the Java version by following the procedures given in the next sections Installing From Windows Internet Explorer Go to Tools gt Internet Options gt Advanced Scroll down and look for a section on Java There should be a check box that says Use Java 2 v1 4 2 If there isn t this could either mean your browser is not activated to use the Java plug in that came with the JRE you have installed or it just means that
24. button Boot Configuration Boot configuration defines the settings for loading the operating system In the event that the ACS fails to boot successfully you can use the Boot Configuration form to change the boot settings The ACS can boot from its internal firmware or from the network By default the unit boots from Flash If you need to boot from the network install one TFTP or BOOTP server with the firmware to boot from and then choose boot from network and fill in the fields You may skip Flash test and RAM test for a faster boot 1 From the top menu select Administration from the left menu select Boot Configuration The system brings up the Boot Configuration form Web Manager for Administrators 133 Configuring the ACS in Expert Mode 134 System Information Notifications Time Date Backup Config Upgrade Firmware Reboot Administration IP Address assigned to Ethernet 192 168 160 10 Watchdog Timer Unit boot from Boot Type active y riash y reer y Boot File Name Server s IP Address zymppecs bin 192 168 160 1 Console Speed Flash Test RAM Test 9600 y Skip Y skip Fast Ethernet Max Fast Ethernet Interrupt Events Auto Negotiation x Figure 4 55 Boot Configuration Form 2 Complete the fields as follows Table 4 42 Boot Configuration Form Fields Field Name Definition IP Address assigned to As indicated Ethernet Watchdog Timer Sets the Watchdog Timer to Active
25. can configure from this form is as follows Table 4 32 Serial Ports Access Modification Form Fields Authentication Type Definition None Local Remote Radius TacacsPlus Ldap Kerberos Local Radius Radius Local Local TacacsPlus TacacsPlus Local RadiusDownLocal TacacsPlusDownLocal kerberosDownLocal No authentication Authentication is performed locally i e using the etc passwd file This is for a terminal profile only The unit takes in a username but does not use it for authentication Instead it passes it to the remote server where it is then used for authentication Authentication is performed using a Radius authentication server Authentication is performed using a TacacsPlus authentication server Authentication is performed against an ldap database using an ldap server Authentication is performed using a Kerberos server Authentication is performed locally first switching to Radius if unsuccessful The opposite of the previous option Authentication is performed locally first switching to TacacsPlus if unsuccessful The opposite of the previous option Local authentication is tried only when the Radius server is down Local authentication is tried only when the TacacsPlus server is down Local authentication is tried only when the kerberos server is down AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Table
26. changes The View IPDUs Info form is used to view information about the status of the IPDU units ACS for Regular Users 27 Security For information on how to configure Power Management refer to the Power Management section of Chapter 4 Web Manager for Administrators Figure 3 4 Power Management Configuration Form Security The Security form allows you to change your password v To Change Your Password 1 From the menu panel select Security The system brings up the Security form 28 AlterPath Advanced Console Server July 2005 Security Connect Power Management Current Password New Password Repeat Doo New Password Figure 3 5 Password Management Form 2 From the Security form enter your current password and your new password twice Select OK when done Log out and log in using your new password to verify your password change ACS for Regular Users 29 Security 30 AlterPath Advanced Console Server July 2005 Chapter 4 Web Manager for Administrators This chapter discusses the procedures for configuring ACS using the Web Manager It is organized as follows Overview Logging In ACS Web Manager GUI Elements Configuring in Wizard Mode e Security Profile e Network Settings e Port Profile e Access data Buffering System Log e Configuring in Expert Mode e Applications Network Security Ports Administration Overview Overview This chapter addresses the System Ad
27. enabled Device generates Fault Reports Traps that are defined in the MIB which the SNMP Agent has implemented The Trap Definition vary with the SNMP Version which defines the messaging format but the information contained in these are essentially identical The major difference between the two message formats is in identifying the events A bit which signals the end of a unit of transmission on a serial line A stop bit may be transmitted after the end of each byte or character A bit mask used to select bits from an Internet address for subnet addressing Also known as Address Mask A protocol which permits secure remote access over a network from one computer to another SSH negotiates and establishes an encrypted connection between an SSH client and an SSH server Set the options for a terminal device interface This command prints information about your terminal settings The information printed is the same as if you had typed stty while interacting with a shell The stty utility sets or reports on terminal I O characteristics for the device that is its standard input Without options or operands specified it reports the settings of certain characteristics usually those that differ from implementation dependent defaults Otherwise it modifies the terminal state according to the specified operands Terminal Access Controller Access Control System Authentication protocol developed by the DDN community that provide
28. forms such as the one shown above These forms are identified by their tabs Select the tab to access the desired form Button Functions The control buttons located on the bottom of the ACS Web Manager window provides you the following functions for operating the interface Table 4 1 Web Manager Buttons Button Name Use Wizard Expert Switches the ACS Web Manager screen to either Expert or Wizard Mode The Expert Mode is the default mode Clicking the Expert mode will change the screen Wizard mode 36 AlterPath Advanced Console Server July 2005 ACS Web Manager Elements Table 4 1 Web Manager Buttons Button Name Use Help Invokes the Help window which provides brief description of the functionality behind the active form Back Wizard Mode Goes back to the previous form i e the form preceding the current form as it appears in the menu Next Wizard Mode Goes to the next form i e the form succeeding the current form as it appears in the menu Try Changes Test or run the system based on the settings from the current form without having to save the configuration Cancel Changes Cancel your changes or revert back to the original configuration parameters apply changes Save your changes to the ACS Flash card Reload Page Expert Refreshed the active page Mode Saving Your Configuration The Unsaved Changes indicator on the lower right hand corner of the Web Manager window reminds y
29. menu to Terminal Profile Menu Create command menu for a terminal i e CLI or VI Note Most of the fields for each form are defined in the procedure For a more detailed definition of these field names or terms refer to the Glossary of this manual Table 4 9 Network Menu Menu Selection Use this menu to Host Settings Configure host connections including Ethernet Port connections DNS Service and Name Service Access Syslog Define the Syslog Servers to enable system logging PCMCIA Management Enable the insertion or ejection of PCMCIA cards configure the type of access and connection e g Modem ISDN Ethernet to ACS VPN Connections Configure IPsec tunnels to establish a secure connection between ACS and a security gateway machine SNMP Daemon Settings Configure the SNMP server to manage complex networks Firewall Configuration Configure static IP tables Host Table View table of hosts create edit and delete hosts Static Routes View create and delete routes from the table 54 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Table 4 10 Security Menu Menu Selection Use this menu to Users and Groups Active Port Sessions Security Profile Create edit users and groups establish change their passwords access rights and privileges View the status of all active port sessions Select a pre defined Security Profile or configure a Custome
30. or Inactive Unit boot from Specify whether to boot unit up from Flash or from the Boot Type Select from the following types of booting bootp tftp or both Boot File Name Filename of the boot program you want to use Server s IP Address As indicated Console Speed Select from 4800 through 118200 Flash Test Select this to test boot from the Flash card You can Skip this test or do a Full test AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Table 4 42 Boot Configuration Form Fields Field Name Definition RAM Test Select this to test boot from RAM You can Skip this test do a Quick test or a Full test Fast Ethernet Select the appropriate Ethernet setting if you need to change the Auto Negotiation default value 100BaseT Half Duplex 100BaseT Full Duplex 10BaseT Half Duplex 10BaseT Full Duplex Fast Ethernet Max The maximum number of packets that the CPU Interrupt Events will handle 3 Select Apply Changes to save your configuration to Flash Backup Configuration The Backup Configuration form allows you to Usea FTP server to save and retrieve your ACS configuration For the backup configuration to work the FTP server must be on the same subnet Ensure that it is accessible from the ACS by pinging the FTP server e Use a storage device to save your configuration v To save configuration to an FTP server 1 From the top menu select Administration fro
31. part of the graphical user interface are typed in boldface Examples The Configuration window the Password field Before You Begin vii Untitled Data Fields Untitled forms User entry words Window levels Naming Conventions ACS Dialog box Form viii Some data entry fields of the GUI windows or forms do not have titles When this field is described in any field definition section of the manual the field is indicated as untitled enclosed in angled brackets Example untitled Type in the port number in this field While most forms are identified by it s menu selection some forms do not bear the title The manual uses initial capitals to refer to their names or titles Examples The Data Buffering form the VPN Connections form the Active Ports Session form Words or characters that you would type in are shown in courier Example myPas8worD Screen levels are also indicated by the greater than symbol gt starting from parent to child to grandchild and so forth In ACS the navigable window types are the forms and the dialog boxes Example Security gt Users and Groups gt Add Short name for the Cyclades AlterPath Advanced Console Server The dialog box is a pop up window that appears and prompts for user input as part of the process for completing a form in order to configure the ACS The form is the largest part of the user interface it contains the user selection or input f
32. program on a server Using RPC a system developer do not need to develop specific procedures for the server The client program sends a message to the server with appropriate arguments and the server returns a message containing the results of the program executed SSH has the same functionality as Telnet see definition for Telnet but adds security by encrypting data before sending it through the network A collection of servers running in the same location see Cluster Simple Mail Transfer Protocol Specifies the format of messages that an SMTP client on one computer can use to send electronic mail to an SMTP server on another computer Short for Simple Network Management Protocol a set of protocols for managing complex networks The first versions of SNMP were developed in the early 80s SNMP works by sending messages called protocol data units PDUs to different parts of a network SNMP compliant devices called agents store data about themselves in Management Information Bases MIBs and return this data to the SNMP requesters Source Webopedia Notifications or Event Reports are occurrences of Events in a Managed system sent to a list of managers configured to receive Events for that managed system These Event 165 Stop Bit Subnet Mask SSH Secure Shell STTY TACACS 166 Reports are called Traps in SNMP The Traps provide the value of one or more instances of management information Any SNMP
33. system waits after the outlet is switched on select OK when done View IPDUs Info The IPDU Info form allows you to view all IPDU information e g number of outlets of each unit current temperature alarm threshold levels firmware etc by serial port The form stores historical values of the maximum current and the maximum temperature To view IPDU information perform the following steps 1 From the top menu bar select Applications from the left menu panel select Power Management from the form tabs select View IPDUs Info AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode 2 The system brings up the IPDUs Info form View rouse UsersManager Conigwation Software Upgrade Serial Port 4 General Information Name PowerMgm 4 Syslog ON Number of Outlets 8 Number of Units 1 Buzzer ON Over Current Protection OFF Master Unit Information Model PM8 154 Software Version 1 2 0 Alarm Threshold 15 04 Current 0 04 Maximum Detected 0 4A Temperature Maximum Detected Figure 4 17 Power Management Information Screen 3 To delete the stored values for the maximum detected current select the Clear Max Detected Current button 4 To delete the stored values for the maximum detected temperature select the Clear Max Detected Temperature button Users Manager The Users Management form of Power Management allows you to assign users to selected outlets for each serial port
34. that the user has access to the requested resources Chips on the motherboard of a computer contain read only memory instructions that are used to start up a computer The operating system of a PC also makes use of BIOS instructions and settings to access hardware components such as a disk drive Some BIOS CMOS settings can be set to scan for viruses causing problems for some installation programs The baud rate is a measure of the number of symbols characters transmitted per unit of time Each symbol will normally consist of a number of bits so the baud rate will only be the same as the bit rate when there is one bit per symbol The term originated as a measure for the transmission of telegraph characters It has little application today except in terms of modem operation It is recommended that all data rates are referred to in bps rather than baud which is easy to misunderstand Additionally baud rate cannot be equated to bandwidth unless the number of bits per symbol is known Ability to detect communication failure transparently and switch from one LAN connection to another The Linux bonding driver has the ability to detect link fail ure and reroute network traffic around a failed link in a manner transparent to the application It also has the ability with certain network switches to aggregate net work traffic in all working links to achieve higher throughput The bonding driver accomplishes this by enslaving all of the Et
35. the network configuration steps described in Chapter 2 you may have already changed the default password If you have not make sure you do so after login After login 1f another administrator is logged in to the Web Man ager the following dialog box appears otherwise the ACS Ports Status page will appear Another administrator root is currently logged in Only one administrator can be logged in at once Decide how you want to proceed C Proceed Log into the device and log off the currently logged in administrator Cancel 3 Click on the appropriate radio button and then click on the Apply button Web Manager for Administrators 33 ACS Web Manager Elements Note Take note of this login procedure All subsequent online procedures in this chapter assume that you are already logged in Note The following Security Advisory appears the first time ACS unit is accessed Note that the browser s pop up blocker should be disabled for this dialog box to appear IMPORTANT Security Advisory O Introduction Console Management provides critical access to management features of attached equipment Please take the required precautions to understand the potential impacts this device may have to your SECURITY policies From Factory From factory this device is configured as follows single password for ROOT all serial port DISABLED DHCP Telnet SSH 1 amp SSH 2Z and HTTP amp HTTP
36. 0 50 0 50 0 50 0 50 0 50 Outlet Outlet Name t State Power Up Interval In the example above the yellow bulbs i e the actual color online when the switch is ON and the opened padlock indicate that the outlets are switched on and unlocked 2 To switch on off an outlet click on the light bulb to lock unlock an outlet click on the padlock In the sample form below outlet 2 is switched off and locked Outlets Manager Outlet Outlet Name Outlet State Power Up Interval ngc X linuxser 3 Mail 4 myoutlet 5 outs 6 LinuxServer it out 8 a2 Web Manager for Administrators Q Q Q Q Q Q Q Q 0 50 0 50 0 50 0 50 0 50 0 50 0 50 0 50 59 Configuring the ACS in Expert Mode 60 3 To save your changes click on the Save Outlets State button located in the form 4 From the lower control buttons of the main window click on the apply changes button To Edit the Power Up Interval You can edit the power up interval of an outlet as follows 1 From the Outlets Manager form Applications gt Power Management select the particular outlet that you wish to edit by clicking the adjacent Edit button The system brings up the Edit Outlet dialog box 3 Edit Outlet Microsoft Internet Exp 15 x Outlet Name nge Power Up Interval fo 50 Figure 4 16 Edit Outlet Dialog Box 2 From the Power Up Interval field of the Edit Outlet dialog box enter the time interval in seconds in which the
37. 132 Setting Network Time Protocol NTP esseere 132 Bo t Configuration RE 133 Backup Configuration ii A ee 135 Up r d Firmware decoradas 138 REBOOT uranio 140 111 Appendix A Hardware Specifications 141 Appendix B Safety Guidelines ooommmmmmmo 143 Safety Guidelines for Rack Mounting the ACS oes 144 Safety Precautions for Operating the ACS eee eee ceteeeeeee 145 Working inside the AlterPath Console Port Server 0 0 0 0 eee 146 Replacing the Battery rosana 146 BCC Warning Statement isss cis sdcccssccsasceasvacas eetacddanapiesceoansccetaseesas 147 Notice About FCC Compliance for all Alterpath ACS Models 147 Canadian DOC Notice eiii ai 147 Aviso de Precauci n S Mark Argentina oooccnoccnonnnonnnnnnnnonncnoncnnnnos 148 Trabajar dentro del AlterPath Advanced Console Server 149 Batera tania 149 Appendix C Supported Browsers and JRE 151 Supported Web Browsers A 152 Instala JRE it hia A A aa de es 152 Tested Environments AAA a tases 152 Installation Requirements veritat rd 152 Installing From Windows Internet Explorer oooonnccnncnnninocccnnno 152 Installing From Windows Netscape or Mozilla oe 153 GIOSSARY iii os ce eceveecedicccccsatenveeeeiens 155 A TTET 171 iv AlterPath Advanced Console Server Before You Begin This manual is designed to guide you in installing and configuring the AlterPath Advanced Console Server through the ACS Web Manager It also
38. 4 32 Serial Ports Access Modification Form Fields Authentication Type Definition IdapDownLocal Local authentication is tried only when the Idap server is down NIS All authentication types but NIS follow the format all authtype lt Authentication gt DownLocal or lt Authentication gt e g all authtype radius or radiusDownLocal or ldap or IdapDownLocal etc NIS requires all authtype to be set as local regardless if it will be nis or its Downlocal equivalent v To configure user group authentication 1 From the top menu select Ports from the left menu select Physical Ports from the form tab menu select Access The system brings up the Access form Authorized Users Groups Type None Selected ports 1 Done 2 Enter the user or the group name 3 From the Type drop down list select the authentication type Web Manager for Administrators 113 Configuring the ACS in Expert Mode Entry Fields Based on Authentication Type The user entry fields that are available from the Access form depend on the authentication type that you select from the Type field Authentication Radius e Authorized Users Groups e First Authentication Server e Hostname e Second Authentication Server e Hostname e First Accounting Server e Hostname e Second Accounting Server e Hostname e Secret e Timeout e Retries Authentication LDAP or LdapDownLocal When you select LDAP authenti
39. 45 connector end and connect the adapter end to your PC s available COM port Note The modem cable is not necessary for a standard installation and configuration Use it when the configuration is complete and you want to access the box remotely through a serial port 4 Connect to the Network Connect the ACS network port to the Ethernet hub or switch Network Parameters This step is necessary to make ACS visible on the network The configuration can be done using the console port of the Cyclades ACS or through the network using the default network settings v To Configure the Network Parameters Using the Console Port 1 Install and launch your serial communication software e g HyperTerminal Kermit or Minicom You can obtain the latest update to HyperTerminal from http www hilgraeve com htpe download html If you are using a PC use HyperTerminal to perform the initial configuration of the ACS directly through your PC s COM port connected with the ACS HyperTerminal which comes with Windows 95 98 Me NT 2K and XP is often located under Start gt Program gt Accessories HyperTerminal emulates a dumb terminal when your PC connects to the serial port console port of the ACS AlterPath Advanced Console Server July 2005 Installation and Configuration Process Select available COM port In HyperTerminal Start gt Program gt Accessories select File gt Properties and click the Connect To tab
40. 5 Configuring the ACS in Expert Mode 3 To add a new syslog server type in the IP address in the New Syslog Server field and click Add Repeat step for as many syslog servers you need to add OR 4 To delete a syslog server select the Syslog server to be deleted from the Syslog Servers scrollable list box and then click Delete 5 Click on the apply changes button at the bottom of the main panel Configuring the ACS in Expert Mode This section presents the procedures for configuring the ACS Web Manager in Expert Mode This mode is designed for the advanced user administrator who needs to configure the ACS beyond the capabilities of the basic wizard mode As indicated in the top menu bar there are five additional areas of ACS configuration in Expert mode Applications on page 56 Network on page 67 Security on page 99 Ports on page 106 Administration on page 125 Expert Mode Menu Each top menu option provides additional side menu selections Their functions are as follows Table 4 8 Applications Menu Menu Selection Use this menu to Connect Select and connect to a port Power Management View and edit IPDU settings This menu comprises five tabbed forms Outlets Manager View IPDUs Info Users Manager Configuration and Software Upgrade Web Manager for Administrators 53 Configuring the ACS in Expert Mode Table 4 8 Applications Menu Menu Selection Use this
41. 5 PCMCIA card 74 PCMCIA Configuration Dialog Boxes 74 PCMCIA Management form 72 PCPU 103 Physical Ports form 106 plugs 7 Port Profile form 44 Port profile 43 Ports configuration 106 Power Management 27 Power Management Configuration 64 Power management form 57 Power Up Interval field 60 Q QuickStart 6 R Rack Mounting the ACS 10 Radius 112 Radius Local 112 RadiusDownLocal 112 Reboot button 140 Reboot form 140 176 AlterPath Advanced Console Server User Manual Reject Options 94 RJ 45 to DB 9 adapter female cross converter 8 RJ 45 to RJ 45 cable 8 RPC 40 RSA Key VPN 82 Rule 87 Run Checksum 139 S Safety vi Safety Guidelines 143 Saving Your Configuration 37 Security 28 Security configuration 99 Security profile 38 custom 39 default 39 moderate 39 open 39 secured 39 Security Settings 40 serial ports 8 Services 40 Sniff Mode 118 SNMP 40 82 SNMP Daemon Settings 82 83 SNMP Trap Notification 130 SNMPv1 v2 and v3 83 SNMPv1 v2 83 SNMPv3 85 Software Upgrade Power Management 64 SSH Access 25 Static Routes form 97 Stop Bits Port Profile 45 STTY Options 121 Syslog form 71 AlterPath Advanced Console Server User Manual 177 T TacacsPlus 112 TacacsPlus Local 112 TacacsPlusDownLocal 112 Telnet Access 25 Terminal Profile Menu 65 Test Configuration 19 Time Date form 132 To 28 to change your password 28 ts_menu Access 26 TTY 102 U United 7 United States power cord for
42. 68 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode DHCP Host Name Console Banner cyclades AlterPath ACS Ethernet Port Primary IP Network Mask 192 168 48 11 255 2595 252 0 Secondary IP Secondary Network Mask MTU 1500 DNS Service Primary DNS Server Secondary DNS Server 192 168 44 21 Domain Name cyclades com Gateway IP 192 168 48 1 Bonding Enabled Figure 4 23 Network Host Settings form with DHCP disabled 3 On the Host Settings form complete or edit the following fields Table 4 14 Host Settings Fields Filed Name Field Definition Host Name The fully qualified domain name identifying the specific host computer within the Internet Console Banner A text string designed to appear on the console upon logging into and exiting from a port as a way to verify or identify the particular port connection Primary IP IP address of the unit Web Manager for Administrators 69 Configuring the ACS in Expert Mode Table 4 14 Host Settings Fields Filed Name Field Definition Secondary IP The second IP address of the unit Configuring the second IP address the unit will be available for more than one network Network Mask The 32 bit number used to group IP addresses Secondary Network Mask MTU DNS Server Secondary DNS Server Domain Name Gateway IP Bonding Miimon Updelay together or to indicate the range of IP ad
43. 7 Unsaved Changes indicator 37 Updelay 70 Upgrade Firmware form 138 Users and Groups confirguration 99 Using the Command Line Interface CLI 24 Using the Web Interface 22 y Virtual Ports form 121 Virtual Private Network 79 VPN 78 79 VPN configuration form 80 W Watchdog Timer 134 Wireless LAN 74 178 AlterPath Advanced Console Server User Manual Wizard Mode 34 AlterPath Advanced Console Server User Manual 179
44. 7002 etc 3000 etc the alias for the server connected to that serial port ACS for Regular Users 25 Using the Command Line Interface CLI 26 lt hostname or IP address gt is the hostname configured in the workstation where the ssh client will run through etc hosts or DNS table It can also be just the IP address of the Alterpath ACS Ethernet s interface configured by the user or learned from DHCP To exit the ssh session press the hot key configured for that ssh client usually ts_menu Access To access the serial port telnet or ssh using the ts_menu login to the CAS unit and after receiving the shell prompt type in ts menu If configured the menu will display the servername otherwise it defaults to the serial port number See the sample menu below Serial Console Server Connection Menu for your Master Terminal Server 1 ttyS1 2 ttyS2 3 ttyS3 4 ttyS4 5 ttyS5 6 ttyS6 7 ttyS7 8 ttys8 Type q to quit a valid option 1 8 or anything else to refresh Closing the session from ts_menu from the console of your unit 1 Enter the escape character The escape character is shown when you first connect to the port In character text Mode the Escape character is caret and bracket for telnet or tilde and period for SSH After entering the escape character the following menu is shown Console escape Commands are l go to line mode c go to character mode AlterPath Advanced
45. AN port and many RS 232 serial ports It is used to connect many terminals to the network Because they have the same physical interfaces terminal servers are sometimes used as console access servers 1 In Unix refers to any terminal sometimes used to refer to the particular terminal controlling a given job it is also the name of a Unix command which outputs the name of the current controlling terminal 2 Also in Unix any serial port 167 168 UDP U Rack Height Unit VPN Watchdog Timer whether or not the device connected to it is a terminal so called because under Unix such devices have names of the form tty User Datagram Protocol uses a special type of packet called a datagram Datagrams do not require a response they are one way only connectionless Datagrams are usually used for streaming media because an occasional packet loss will not affect the final product of the transmission A standard computer rack has an internal width of 17 inches Rack space on a standard rack is measured in units of height U One U is 1 75 inches A device that has a height of 3 5 inches takes 2U of rack space Virtual Private Networking allows local area networks to communicate across wide area networks typically over an encrypted channel See also IPsec A watchdog timer WDT is a device or electronic card that performs a specific operation after a certain period of time if something goes wrong with an electronic system a
46. AlterPath Advanced Console Server User Manual 3 ALTERPATH E alee aise ne sacan naa cyclades Cyclades Corporation 3541 Gateway Boulevard Fremont CA 94538 USA 1 888 CYCLADES 292 5233 1 510 771 6100 1 510 771 6200 fax http www cyclades com Release Date July 2005 Part Number PAC0379 O 2005 Cyclades Corporation This document contains proprietary information of Cyclades Corporation and is not to be disclosed or used except in accordance with applicable contracts or agreements Information in this document is subject to change without notice All trademarks trade names logos and service marks referenced herein even when not specifically marked as such belong to their respective companies and are not to be considered unprotected by law The following are registered or registration pending trademarks of Cyclades Corporation Cyclades and AlterPath ActiveX Microsoft Microsoft Internet Explorer Windows and Windows NT are registered trademarks of Microsoft Corporation in the United States and other countries AIX is a registered trademark of International Business Machines Corporation in the United States and other countries FreeBSD is a registered trademark of the FreeBSD Foundation HP UX is a registered trademark of the Hewlett Packard Corporation Linux is a registered trademark of Linus Torvalds in the United States and other countries Mozilla and Mozilla Firefox are trademarks of the Mozilla F
47. Caution To help prevent electric shock plug the ACS into a properly grounded power source The cable is equipped with a three prong plug to help ensure proper grounding Do not use adapter plugs or remove the grounding prong from the cable If you have to use an extension cable use a three wire cable with properly grounded plugs Caution To help protect the ACS from electrical power fluctuations use a surge suppressor line conditioner or uninterruptible power supply Be sure that nothing rests on the cables of the ACS and that they are not located where they can be stepped on or tripped over Do not spill food or liquids on the ACS Safety Guidelines 145 146 1 Caution Do not push any objects through the openings of the ACS Doing so can cause fire or electric shock by shorting out interior components Caution Keep your ACS away from heat sources and do not block host s cooling vents Caution The AlterPath Console Server product DC version is only intended to be installed in restricted access areas Dedicated Equipment Rooms Equipment Closets or the like in accordance with Articles 110 18 110 26 and 110 27 of the National Electrical Code ANSI NFPA 701 1999 Edition Use 18 AWG or 0 75 mm2 or above cable to connect the DC configured unit to the Centralized D C Power Systems Install the required double pole single throw DC rated UL Listed circuit breaker between the power source an
48. Configuring the ACS in Expert Mode Z New Modify Port Microsoft Internet Explorer TES E E E 12 10 10 10 10 0 30 30 30 30 0 telnet 13 Po 10 10 10 10 1 30 30 30 30 1 telnet 14 gt 10 10 10 10 2 30 30 30 30 2 telnet 15 sd 10 10 10 10 3 30 30 30 30 3 telnet 16 sd 10 10 10 10 4 30 30 30 30 4 telnet 17 10 10 10 10 5 30 30 30 30 5 telnet 18 sd 10 10 10 10 6 30 30 30 30 6 telnet 19 sd 10 10 10 10 7 30 30 30 30 7 telnet 20 sd 10 10 10 10 8 30 30 30 30 8 telnet 21 sid 10 10 10 10 9 30 30 30 30 9 telnet 22 Po 10 10 10 10 10 30 30 30 30 10 telnet 23 Po 10 10 1010 11 30 30 30 30 11 telnet 24 zy 10 10 10 10 12 30 30 30 30 12 telnet 26 Po 10 10 10 10 13 30 30 30 30 13 telnet 26 is 10 10 10 10 14 30 30 30 30 14 telnet 27 is 10 10 10 10 15 30 30 30 30 15 telnet si 5 For each port to be named enter the port name in the corresponding Port Name field and then select the OK button 6 Click on the apply changes button to save your configuration v To Delete a Slave 1 To delete a slave from the list select the unit to be deleted from the Virtual Ports form and then click Delete Ports Status Show the status of each port Information provided are RS 232 signal status and which users are connected to each port 124 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Physical Ports Virtual Ports SAS Administration System Information Figure 4 48 Ports Status Form RT
49. Configuring the ACS in Expert Mode Time Date The Time Date form is used to enable ACS to work as an NTP client Network Time Protocol NTP is a standard for synchronizing your system clock with the true time defined as the average of many high accuracy clocks around the world By default NTP is disabled and you may enter the time and date manually using the Time Date form Manual Setting To set the time and date manually i e locally without NTP perform the following steps 1 Select Administration from the top menu bar and then select Time Date from the left menu panel The system brings up the Time Date form Administration System Information Notifications Network Time Protocol Disable y Month 5 Day i2 Year 2002 Time Hour fis Minute fis Second feo Figure 4 54 Time Date Form 2 If you are not using NTP complete the date and time fields by selecting the appropriate numbers from the dropdown list boxes 3 Click on the Apply Changes button to complete the procedure Setting Network Time Protocol NTP To set the time and date through NTP perform the following steps 132 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode 1 From the Time Date form choose Enable from the Network Time Protocol field 2 Type in the address of the NTP server in the NTP Server field Network Time Protocol Enable NTP Server fizo 6 15 28 3 Click on the Apply Changes
50. OT oa re ema sanancaedey teas cadane dees E AN EEE 52 Configuring the ACS in Expert Mode cocococncccnoccconncnoncnannnonnnononcnoncnnnnos 53 Expert Mode Men A A EEEE ARA 53 ADPIC seg 25 2 a A o 56 Comedia As 56 Power Management isserrat ni geiao ute iais 57 Terminal Profile Menu msniniciitn alla ica ld 65 NetWork enere tenuis ati aad eea do amet aad ees eerie 67 Host SCE IS is ache ech ance ict ose ooeaa O ee Draenei 68 AlterPath Advanced Console Server Contents O e ls 71 PCMCIA Mana mentid 72 WG IS VEN osito dad 78 VPN Connections sitial lei 80 SNMP Daemon Settings ti iaa 82 Firewall CONSUL aio 86 E A A nd 95 Statie ROUTES rol scale ci S 97 SECT ai 99 Users and TOLOSA di 99 Active Ports SESSIONS ansoriciindioininosiciai sicario asdea niiina 102 Securty Profle cater caerecaea nad sigue a a haaeeerees 103 POTS Seek eee i Eel a A NIA a 106 Physical Ports srs Gali E E eine Bee ee eee E 106 General Port Configuration ica iia 108 Access Power Management cooococcnocccnoncnononcnononcnnnnncnonnncnnnnnannnns 110 Access User and Group Setup oooocccnnocccnocnonocanonnnnononacononaconnnos 111 Data B ffering valid dis a R lonas 115 Multi USET inem tues let otal aa doce emesis 116 Power Management 265432 casos ceaa o 118 Other Setting cesis ei n tendiendo 120 A n a a a R aiatant 121 Ports Stats a dde 124 A LEAL o eee ed lo 125 SS AA O ioeina 125 O A O 126 A ett ena tases a iiie e asier 132 Manual Setting ccnn niening dar R dee
51. S CTS DCD DTR System information provides information about the ACS version CPU memory including PCMCIA Notifications Kernel Version Time Date Boot Configuration Backup Config Upgrade Firmware Reboot MemTotal MemPree MemShared Web Manager for Administrators Administration Linux version 2 4 17_mwvi21 linuxplanet root exodus cyclades com gce version 2 95 3 20010315 release MontaVista 1 gcc version 2 95 3 20010315 release MontaVista 1 Tue May 11 13 25 07 PDT 2004 AlterPath ACS4 Linux W_2 2 0z May 11 04 10 Wed May 12 15 06 24 20 49 Bxx 48MHz 0 0 pvr 0050 0000 47 82 127172 kB 54472 kB OkB 125 Configuring the ACS in Expert Mode Figure 4 49 System Information View To view system information select Administration from the top menu bar select System Information from the left menu panel Notifications The Notification form is used to set up alarm notification to users through email pager or SNMP traps 1 From the top menu bar select Administration from the left menu panel select Notifications The system invokes the Notifications form Administration System Information Notification Alarm For Data Buffering Time Date Boot Configuration Backup Config Upgrade Firmware Reboot Figure 4 50 Notifications Form 2 Complete the main form as follows Table 4 38 Notification Form Fields Field Name Definition Notification Alarm for Checkmark t
52. S enabled Cyclades STRONGLY recommends 1 To change the ROOT password before setting up the box for secure access to the ACS equipment 2 That you SELECT A SECURITY PROFILE to complete the INITIAL SETUP Security is dependent on Policy and is Configurable to fit in environments with varying levels of Security Cyclades provides three pre set Security Levels SECURED MODERATE and OPEN and in addition the ability to set a CUSTOM Security Profile 3 Do not leave the equipment idle WITHOUT selecting a SECURITY PROFILE 4 To ENABLE Serial Ports and CONFIGURE them using Web Ul or CLI Refer to the Quick Start Guide or the User s Guide for Security Profile selection details and Serial Port configuration Close ACS Web Manager Elements The ACS Web Manager operates in two modes e Wizard e Expert Wizard Mode The wizard is designed to simplify configuring the ACS for the administrator It is designed to perform the necessary set up and configuration quickly 34 AlterPath Advanced Console Server July 2005 ACS Web Manager Elements When you log in to ACS by default the system brings up the Expert Mode To change to the Wizard Mode click on the button located in the left bottom corner of the screen labeled Wizard Step 2 Network Settings Step 3 Port Profile Step 4 Access Step 5 Data Buffering Currently there is NO SECURITY PROFILE set Step 6 System Log You must define a Security Level before procedi
53. ameters oooococnnocccnoncccnonanononanonananonnnaconnncn ns 12 Presinstal Ch cklist ant a cdta ds ln e od 12 Installation and Configuration Process oooonoccnonccnonononocannnonn nono nononcnnnns 13 A A A 13 Network PafametefS sisimas ee na rS ET RTT ii 14 Configure the ACS in Wizard Mode cocooooncccnocononnnconcnannnnnncconncnnncnnnos 19 Test the Configuration gar didas 19 Configure the ACS in Expert Mode cococoocccnoncccnonccononcnionancnonnccnnnncnnns 19 Save the Chances tona a a e E N N E esate 19 Chapter 3 ACS for Regular Users asiassaan 21 Using the Web Manager ti dida 22 Using the Command Line Interface CLI ooooooocccnocaccnonccinonacinananonnos 24 Logging into the Terminal hu ita tt 23 A as cons E A S ARETES SS 25 SOLACE eee acini tele da iaia 25 bamen ACCESS de 26 Power Management cssinoscinotiiseresnrsiiiigiii nini sepsis 27 OEE 0 LA AREE E A E E E 28 Chapter 4 Web Manager for Administrators 31 OVETV EW ara a AASE e ene eee 32 e A E EEES AEE 32 ACS Web Manager Elements oocinonocinnoncconaccnnonoconnncc onccconneci nncc nnos 34 Wizard Mode ds 34 Expert Mode a ad toh la a aaa 35 Button PUnCt0ons vierta isa arene 36 Saving Your Configuration s c3i cess cgscus danita arias piensa 37 Configuring the ACS in Wizard Mode coocococccnocccooncnononannnonnnonnncnoncnanos 38 Sec rity Profe min oa a E EE E E 38 Network Settings diia 41 A E R E E 43 ACCESS do 45 Data B ffering sintio dada 49 System D
54. ath ACS Advanced Administration Guide Package Contents There are six models of the AlterPath Advanced Console Server based on the number of serial ports ACS48 e ACS32 e ACS16 e ACS8 ACS4 ACSI All models are available with either a single A C or VDC or double A C or 48 VDC power supply The shipping box contains the AlterPath Advanced Console Server along with the items shown in Table 2 1 The entry for each part provides an illustration its part number P N description and purpose You can use checkboxes to check off each item and you can use the part numbers from this table to reorder any of the parts The list is numbered for internal cross referencing among descriptions within this table Table 2 1 Shipping Box Contents Part Numbers and Description R Item P N Description Purpose o amp PAC0266 Documentation CD PDF copies of this guide and a OS all other Cyclades product y documents 2 PAC0199 AlterPath ACS Basic installation guide in QuickStart Guide printed format Written for users experienced in installing Cyclades products AlterPath Advanced Console Server July 2005 R Item P N Description Purpose 3 Power cable Two To connect the ACS to a C an ee cables are included power source The for the dual power destination country is used to supply units determine which type of cord is shipped based on the country s standard power outlet The prongs of avai
55. ath Advanced Console Server July 2005 Appendix B Safety Guidelines The following Safety Guidelines for AlterPath Advanced Console Server are described in this appendix Safety Guidelines for Rack Mounting the Advanced Console Page 142 server Safety Precautions for Operating the Advanced Console Page 143 server Working inside the AlterPath Advanced Console Server Page 144 Replacing the Battery Page 144 FCC Warning Statement Page 144 Notice About FCC Compliance for all Alterpath Advanced Page 145 Console Server Models Canadian DOC Notice Page 145 Aviso de Precauci n S Mark Argentina Page 145 Trabajar dentro del AlterPath Advanced Console Server Page 146 Bater a Page 146 Safety Guidelines for Rack Mounting the ACS The following considerations should be taken into account when rack mounting the AlterPath Advanced Console Server Temperature The manufacturer s maximum recommended ambient temperature for the AlterPath Advanced Console Server is 122 F 50 C Elevated Operating Ambient Temperature If the ACS is installed in a closed or multi unit rack assembly the operating ambient temperature of the rack environment may be greater than room ambient temperature Therefore consideration should be given to installing the equipment in an environment compatible with the manufacturer s maximum rated ambient temperature See above Reduced Air Flow Installation of the e
56. bility and thus need some way to tell data from commands A LAN cable and access protocol that uses twisted pair or coaxial cables and CSMA CD Carrier Sense Multiple Access with Collision Detection a method for sharing devices over a common medium Ethernet runs at 10 Mbps Fast Ethernet runs at 100 Mbps Ethernet is the most common type of LAN Flash refers to a type of memory that can be erased and reprogrammed in units of memory known as blocks rather than one byte at a time thus making updating to memory easier A method of controlling the amount of data that two devices exchange In data communications flow control prevents one modem from flooding the other with data If data comes in faster than it can be processed the receiving side stores the data in a buffer When the buffer is nearly full the receiving side signals the sending side to stop until the buffer has space again Between hardware such as your modem and your computer hardware flow control is used between modems software flow control is used Short for File Transfer Protocol The protocol for exchanging files over the Internet FTP works in the same way as HTTP for transferring web pages from a server to a user s browser FTP uses the Internet s TCP IP protocols to enable data transfer Ability to remove and add hardware to a computer system without powering off the system AlterPath Advanced Console Server July 2005 ICMP In band Network Manag
57. button when done Click on the apply changes located at the bottom of the ACS configuration window to save your configuration Adding a Rule The forms and dialog boxes for adding a rule is similar to the ones used for editing a rule Refer to the Editing a Rule procedure section for a definition of the user input fields 1 aRU N From the Firewall Configuration form select the chain to which you wish to add a rule or if you are adding a new chain select the Add button and follow the procedure for Adding a Chain Click on the Edit Rule button The system brings up the Edit Rule for Chain dialog box From the Edit Rule for Chain dialog box click on the Add button The system brings up the Add Rule dialog box Complete the Add Rule dialog box Refer to the Editing a Rule section for a definition of the input fields as needed Click on the apply changes button located at the bottom of the ACS configuration window to complete the procedure About the Reject Options Section When Reject is selected as the target the Reject Options Section appears with the following fields 94 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Table 4 27 Reject Options Section Fields Field Name Definition Reject with Choices are icmp net unreachable icmp host unreachable icmp port unreachable icmp proto unreachable icmp net prohibited icmp host prohibited echo reply tcp reset
58. cation is performed against an LDAP database using an LDAP server Selecting LdapDownLocal means that authentication is tried on LDAP Server LDAP Base Domain Name e Secure LDAP Authentication Type NIS LocalNIS or NISLocal All ACS only e Authorized Users Groups NIS Domain Name e NIS Server IP Authentication Type Kerberos KerberosDownLocal e Kerberos The server performing the authentication 114 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode e KerberosDownLocal Local authentication is tried only when the kerberos server is down e Authorized Users Groups e Kerberos Server Realm e Kerberos Realm Domain Name Data Buffering 1 From the top menu select Ports from the left menu select Physical Ports from the Physical Ports form select the ports to modify from the resulting form select the Data Buffering tab The system brings up the Data Buffering form The form below shows both checkboxes Enable Data Buffering and Buffer to Syslog selected to reveal all the form fields Data Buffering Enable Data Buffering M Buffer to Syslog Destination Local Mode Circular File Size Bytes a Record the timestamp in the data buffering file I Show Menu Show all options y Syslog Server Facility Number Local0 y Syslog Buffer Size 0 Buffer SysLog at all times Buffer SysLog only when nobody is connected to the port y Selected ports 1 Done
59. circular File size Bytes Loo Record the timestamp in the data buffering file I Show Menu Show all options Figure 4 12 Data Buffering Form 2 Select the Enable Data Buffering checkbox if unselected The system invokes the Data Buffering input fields 3 Complete the input fields as follows Table 4 7 Data Buffering fields Field Name Definition Destination Destination of the buffer files Local i e Ramdisk or Remote 50 AlterPath Advanced Console Server July 2005 Configuring the ACS in Wizard Mode Table 4 7 Data Buffering fields Field Name Definition Mode If you selected Local destination choose the file sort mode Select Linear for sequential files Circular for non sequential files File Size Bytes If you selected Local destination the value for this field cannot be zero Record the time Commands the system to include a time stamp in stamp the buffer Data Buffering file Name of the buffer file Show Menu Defines what you want to show in the menu of the buffer file Select from Show all options No Show data buffering file only and Show without the erase options 4 If you selected Remote from the Destination field type in the NFS File Path from the resulting form i e specify the NFS mount point The NFS server must be already configured and the mount point exported Set up data buffering file and mode for ports controlled by the ACS4 Enable Data Bufferi
60. cket to another user defined chain Source IP The source IP address Mask Source network mask Required when a network should be included in the rule Web Manager for Administrators 91 Configuring the ACS in Expert Mode Table 4 25 Edit Rule Dialog Box Fields Field Name Definition Inverted Select box to invert the target action i e the action assigned to the target will be performed to all source IPs Masks except to the one just defined Destination IP Destination IP address Mask Destination network mask Inverted Select box to invert the target action i e the action assigned to the target will be performed to all Destination Mask IPs except to the one just defined Protocol The transport protocol to check If the numeric value is available select Numeric and type the value in the adjacent text input field otherwise select one of the other options Inverted Select box to invert the target action i e the action assigned to the target will be performed to all protocols except to the one just defined Interface The interface where the IP packet should pass Inverted Select box to invert the target action i e the action assigned to the target will be performed to all interfaces except to the one just defined Fragments Indicates the fragments or unfragmented packets to be checked The firewall 1 e IP Tables can check for All Packets 2nd 3rd fragmented packets Non fragmen
61. cted ports all Done Figure 4 45 Serial Ports Power Management Form 2 Complete the form as follows Table 4 35 Serial Ports Power Management Form Fields Field Name Definition Enable Power Management on this Port Power Management Port Power Management Key Allow All Users Allow Users Groups Allowed Users Groups Check mark to enable Power Management on the the selected port s View listbox for the PM ports and the assigned outlet numbers The key sequence which the allowed user s can use to perform power management Radio button to allow all users to perform power management on this port Radio button to allow only selected users or groups to perform power management on this port View List Box of Allowed Users or Groups Use the Delete or Add button to maintain this listbox Web Manager for Administrators 119 Configuring the ACS in Expert Mode 120 3 Select the apply changes button at the bottom of the ACS configuration window to save your configuration Other Setting The Other form is used to define less commonly used port settings such as the Port IP Alias STTY options TCP keepalive intervals enabling Windows EMS and the like v To Configure Other Port Settings 1 Select Ports from the top menu select Physical Ports from the left menu select Other from the row of tabs The system brings up the last tabbed form for Physical Ports Port IP Alias TCP Port
62. ctions Form Fields Field Name Definition Connection Name Authentication Protocol Authentication Method Remote Right ID IP Address Name of the VPN connection Authentication protocol used to establish a VPN connection Authentication method used to establish a VPN connection Set the following values Identification name Remote IP address Web Manager for Administrators 81 Configuring the ACS in Expert Mode 82 Table 4 22 Add Modify VPN Connections Form Fields Field Name Definition NextHop The router to which the Console Server sends packets in order to deliver them to the left Subnet Mask As indicated RSA Key You may use the copy and paste feature of Local Left ID IP Address NextHop Subnet Mask RSA Key Boot Action Pre Shared Secret your browser to enter the RSA key Set the following values Identification name Local IP address The router to which the Console Server sends packets in order to deliver them to the right As indicated You may use the copy and paste feature of your browser to enter the RAS key Boot action with regards to generating an RSA key pair upon system boot The pre shared password between left and right users 4 Select the OK button 5 Select the apply changes button to save your configuration SNMP Daemon Settings Short for Simple Network Management Protocol SNMP is a set of protocols for manag
63. d Filename to which you have rights to access and write The Path and Filename field must contain the full path and the filename that you will assign to the backup file Example To upload to the upload folder with the filename AcsxxxxConfig040521 type in the following in the Path and Filename field upload AcsxxxxConfig040521 Always check the FTP server s upload folder after you have selected the Save to FTP Server button Ensure that the file is there as some FTP servers do not return error conditions which can cause the ACS to display a DONE result even though the FTP did not store a copy v To Save Configuration to a Storage Device Note For this feature to work the RESTORECONF utility must be modified to enable the system to read the configuration file from the compact flash Refer to the ACS Advanced Administration Guide for more details 1 From the top menu select Administration from the left menu select Backup Configuration 2 From the Type dropdown field of the Backup Configuration form select Storage Device The system displays the following form Web Manager for Administrators 137 Configuring the ACS in Expert Mode Administration System Information Notifications E Save Load Boot Configuration Type Storage Device Upgrade Firmware Reboot Default Configuration I Replace Configuration PF Figure 4 57 Backup Configuration Form Storage Device 3 Complete the form as fo
64. d by dots The part on the left is the most specific and the part on the right is the most general A given machine may have more than one Domain Name but a given Domain Name points to only one machine For example the domain names matisse net mail matisse net workshop matisse net can all refer to the same machine but each domain name can refer to no more than one machine Usually all of the machines on a given Network will have the same thing as the right hand portion of their Domain Names matisse net in the examples above It 1s also possible for a Domain Name to exist but not be connected to an actual machine This is often done so that a group or business can have an Internet e mail address without having to establish a real Internet site In these cases some real Internet machine must handle the mail on behalf of the listed Domain Name A sequence of special characters that sends a command to a device or program Typically an escape sequence begins with an escape character but this is not universally true 157 158 Ethernet Flash Flow Control FTP Hot Swap An escape sequence is commonly used when the computer and the peripheral have only a single channel in which to send information back and forth If the device in question is dumb and can only do one thing with the information being sent to it for instance print it then there is no need for an escape sequence However most devices have more than one capa
65. d the AlterPath Console Server DC version Minimum Breaker Rating 2A Required conductor size 18 AWG Working inside the AlterPath Console Port Server Do not attempt to service the AlterPath Advanced Console Server yourself except when following instructions from Cyclades Technical Support personnel In the latter case first take the following precautions Turn the AlterPath Advanced Console Server off 2 Ground yourself by touching an unpainted metal surface on the back of the equipment before touching anything inside it Replacing the Battery Caution There is the danger of explosion if the battery is replaced incorrectly Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used batteries according to the manufacturer s instructions AlterPath Advanced Console Server July 2005 Vorsicht Bei Einsetzen einer falschen Batterie besteht Explosionsgefahr Ersetzen Sie die Batterie nur durch den gleichen oder vom Hersteller empfohlenen Batterietyp Entsorgen Sie die benutzten Batterien nach den Anweisungen des Herstellers FCC Warning Statement The AlterPath Advanced Console Server has been tested and found to comply with the limits for Class A digital devices pursuant to Part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment g
66. ddress of the PCMCIA card Remote IP The remote IP address of the PCMCIA card Call Back Check box to enable the callback security feature Phone Number The phone number that the ACS uses to call back Web Manager for Administrators 75 Configuring the ACS in Expert Mode Access Method GSM If the selected Access Method is GSM the following fields are used loxi aE E GSM bs Local IP l Remote IP l Pin Number l Call Back Table 4 18 Form Fields for a GSM Card Field Name Definition PCMCIA Card Select GSM from the pull down box Local IP The local IP address of the PCMCIA card Remote IP The remote IP address of the PCMCIA card Pin Number The personal identification number associated with the GSM Call Back Check box to enable the callback security feature Access Method Ethernet If the selected Access Method is Ethernet the following fields are used 76 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode A Network Access Method Configuration ox cancel Her Ethernet o x IP Address Network Address Y Table 4 19 Form Fields for an Ethernet LAN Card Field Name Definition PCMCIA Card Select Ethernet from the Pull down box IP Address The local IP address of the Ethernet Network Address The network address of the Ethernet Access Method Compact Flash If the selected Access Method is Compact F
67. dresses for this IP network subnet supernet Optional Maximum Transmission Unit used by the TCP protocol Address of the Domain Name Server Address of the backup Domain Name Server The name that identifies the domain e g domainname com As indicated Enables redundancy for the Ethernet devices using the standard Ethernet interface as the primary mode of access and one PCMCIA card as a secondary mode of access If enabled the following values should be set Configure the interval in milliseconds in which the active interface is checked to see if it is still communicating Configure the time in milliseconds that the system will wait to make the primary interface active after it has been detected as up Caution If you have set IP Filtering rules before bonding is activated the interface reference in the firewall configuration will be ethO You need to change the interface to bondO in order to reference the AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode bonded interface See Firewall Configuration on page 86 or The Advanced Administration Guide Chapter 3 4 Select the apply changes button at the bottom of the application window to complete the procedure Syslog The Syslog form allows you to configure one or more syslog servers to receive ACS generated syslog messages The ACS generates syslog messages related to users connecting to ports login failu
68. e Object Identifier AlterPath Advanced Console Server July 2005 Packet Parity PCMCIA Port Glossary A packet is a basic communication data unit used when transmitting information from one computer to another The maximum length of a packet depends on the communication medium As an example in Ethernet networks the maximum length is1500 bytes A data packet can be divided into two parts the header part and the data part The header contains information needed for communication between nodes the data is the body of the packet that is ultimately received by the application In serial communications the parity bit is used in a simple error detection algorithm As a stream of data bits is formed an extra bit called the parity bit is added This bit is set on 1 or off 0 depending on the serial communications parameters set in the UART chip The following lists the available parity parameters and their meanings Odd Parity bit set so that there is an odd number of 1 bits Even Parity bit set so that there is an even number of 1 bits None Parity bit is ignored value is indeterminate Personal Computer Memory Card International Association An organization consisting of some 500 companies that has developed a standard for small credit card sized devices called PC Cards Originally designed for adding memory to portable computers the PCMCIA standard has been expanded several times and is now suitable for many ty
69. e common and sniff session multiple sessions from the same port If configured as No i e do not allow multiple sessions only two users can connect to the same port simultaneously If configured as Yes more than two simultaneous users can connect to the same serial port AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode A Sniffer menu is presented to the user and they can choose to e Open a sniff session e Open a read and or write session e Cancel a connection e Send a message to other users connected to the same serial port If it is configured as RW only read and or write sessions will be opened and the sniffer menu won t be presented If configured as sniff_session only a sniff session will be opened and the sniffer menu won t be presented Default value no v To configure ACS to allow multiple sessions 1 Select Ports from the top menu bar select Physical Ports from the left menu panel The system brings up the Physical Ports list 2 From the Physical Ports list select the Port s you wish to modify to enable multiple sessions 3 Select the Multi User tab from the resulting form The system invokes the Multi User form Allow Multiple Sessions No Sniff Mode Privilege Users 4 Menu Hotkey fez v Notify Users Selected ports 1 Done Figure 4 44 Multi User Form Web Manager for Administrators 117 Configuring the ACS in Expert Mode 5 C
70. ec provides similar services as SSL but it works on a network layer Through IPsec you can create encrypted tunnels VPN or encrypt traffic between two hosts A set of communications standards allowing a single wire or optical fibre to carry voice digital network services and video ISDN is intended to eventually replace the plain old telephone system 159 160 Kerberos LDAP MAC Masquerading MTU Kerberos was created by MIT as a solution to network security problems The Kerberos protocol uses strong cryptography so that a client can prove its identity to a server and vice versa across an insecure network connection After a client and server has used Kerberos to prove their identity they can also encrypt all of their communications to assure privacy and data integrity as they go about their business Lightweight Directory Access Protocol A software protocol for enabling anyone to locate organizations individuals and other resources such as files and devices in a network whether on the Internet or on a corporate intranet LDAP is a lightweight smaller amount of code version of DAP Directory Access Protocol which is part of X 500 a standard for directory services in a network Medium Access Control Internationally unique hardware identification address that is assigned to the NIC Network Interface Card which interfaces the node to the LAN Where a system acts on behalf of other systems such as whe
71. em P N Description Purpose 9 CAB0025 RJ45 to DB25M Use for modems and other C Ca straight thru cable DCE devices 10 CAB0042 DB9F to DB25F To connect the RS 232 serial C crossover cable port to a computer that has a ASC1 Only DB 25 male connector 11 CON0071 DB25F Loopback Use to test and diagnose serial ports 12 CON0093 DB9F to DB25M Use to convert serial port O adapter connectors ASCI Only 13 CON0095 3 5mm Block Plug Use to establish RS 485 C ASCI Only connection HARO370 2 Mounting Use to mount the ACS to a S ba bs brackets with 8 screws 2 spares rack or cabinet To mount on a wall order the brackets under part number HARO220 Installing the ACS Rack Mounting the ACS R Item P N Description Purpose 15 POW0021 Power Supply Power supply for ACS1 5V 2 5A ACSI Only Rack Mounting the ACS To rack mount and connect the ACS to your network perform the following steps 1 Install the brackets onto the front or back edges of the box using a screw driver and the screws provided with the mounting kit 2 Mount the ACS box in a secure position Note Refer to Appendix B Safety Guidelines section of this manual to ensure safety Caution Install your AlterPath Advanced Console Server near the power managed equipment and where there is an adjacent and accessible wall socket outlet 3 Proceed to the Installation and Configuration section of this chapter
72. ement IP Address IP packet filtering IPsec ISDN Glossary Internet Control Message Protocol is an Internet protocol sent in response to errors in TCP IP messages It is an error reporting protocol between a host and a gateway ICMP uses Internet Protocol IP datagrams or packets but the messages are processed by the IP software and are not directly apparent to the application user In a computer network when the management data is accessed using the same network that carries the data this is called in band management A 32 bit address assigned to hosts using TCP IP It belongs to one of five classes A E and is expressed as 4 octets separated by periods formatted as dotted decimals Each address has a network number an optional sub network number and a host number The first two numbers are used for routing while the host number addresses an individual host within the network or sub network A subnet mask is used to extract network and sub network information from the IP address This is a set of facilities in network equipment that allows the filtering of data packets based on source destination addresses protocol TCP port number and other parameters Packet filtering is one of the main functions of a firewall Short for IP Security Protocol IPsec is an extended IP protocol that provides encrypted security services These services enable authentication as well as for access and trustwothiness control IPs
73. enerates uses and can radiate radio frequency energy and if not installed and used in accordance with the Installation amp Service Manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user is required to correct the problem at his or her own expense Notice About FCC Compliance for all Alterpath ACS Models To comply with FCC standards the AlterPath Advanced Console Server require the use of a shielded CAT 5 cable for the Ethernet interface Notice that this cable is not supplied with either of the products and must be provided by the customer Canadian DOC Notice The AlterPath Advanced Console Server does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications L AlterPath Advanced Console Server n mete pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la classe A prescrites dans le r glement sur le brouillage radio lectrique edict par le Minist re des Communications du Canada Safety Guidelines 147 148 Aviso de Precauci n S Mark Argentina Por favor de leer todos los avisos de precauci n como medida preventiva para el operador y el AlterPath Advanced Console Server precauci n No hacer funcionar el AlterPath Advanced Console Server con
74. er Physical Ports The Physical Ports form is used to select the ports you wish to configure i e all ports or individually selected ports Once you have selected the port s to configure you will have access to five tabbed forms to configure any of the following Table 4 30 Physical Ports Form Fields Tab Name Use this form to General Define general port settings Connect to an IPDU port and select the connection type SSH Telnet or both Access Designate users and groups to authenticate and assign authentication type or server Data Buffering Define data buffering mode size syslog server etc Multi User Enable concurrent usage and sniff mode Power Management Other port settings Enable Power Management for the selected port s assign users and groups to enable them to set the IPDU settings for these port s Configure other port settings such as break interval login banner PPP options etc 106 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode v To Modify Port Access 1 From the top menu select Ports from the left menu select Physical Ports Note By default all Serial Ports are disabled The Administrator can activate and assign specific users to individual physical ports The system invokes the Physical Ports Modification form Virtual Ports Ports Status Console Telnet 9600 8N1 IPDU 9600 8N1 Console Telnet 9600 8N1 Console Tel
75. ert Mode 35 Expert Mode Menu 53 F Firewall configuration 86 Flow Control Port Profile 45 FreeSWAN 79 FTP 40 AlterPath Advanced Console Server User Manual 173 G General form Ports 108 GSM 74 H Hardware Specifications vi Host Tables form 95 HyperTerminal 12 I ICMP 40 ICMP Options 93 Initial Configuration Using the ACS Console Port 14 installation and configuration process 13 IP filtering 86 IPDU 8 IPSec 40 IPsec tunnels 79 ISDN 74 J Java 2 JRE 12 Java window 24 JCPU 103 JRE vi K Kerberos 112 kerberosDownLocal 112 Kermit 12 174 AlterPath Advanced Console Server User Manual L LAN 8 launch an SSH session 66 Ldap 112 IdapDownLocal 113 Local Radius 112 Local TacacsPlus 112 Logging In Web User Interface 32 Login Banner 121 M Miimon 70 Minicom 12 Modem 74 modify selected ports 107 mounting brackets 9 Multi User 106 Multi User form 116 N Net SNMP package 82 Network Host Settings 68 Network Settings 41 New Modify Host dialog box 96 New Modify Route dialog box 98 New Modify SNMP v3 Configuration dialog box 86 New Modify VPN Connection dialog box 81 NIS NIS 113 Notification Alarm for Data Buffering 126 Notifications form 126 NTP client 132 NTP Setting 132 AlterPath Advanced Console Server User Manual O OID 83 Outlets Manager form 58 60 P Package Contents 6 Pager Notifications 129 Parameters for All Serial Ports 44 Parity Port Profile 4
76. es button v To Delete a User 1 From the Users scrollable field box of the Access form select the user that you wish to delete 2 Select the Delete button 3 Select apply changes For information on how to configure users and groups see Users and Groups under configuring ACS in expert mode Data Buffering This step configures the data buffering file and mode for all ports that ACS controls You can set data buffering to be done in local files or in remote files through NFS When using remote files the remote server s disk partition space imposes a limitation and the data is kept in linear or sequential files in the remote Server When using local files the size of the available RAMdisk also imposes a limitation You can have data buffering done in file syslog or both Web Manager for Administrators 49 Configuring the ACS in Wizard Mode If you accept the default configuration values for data buffering skip this step and proceed to Step 6 System Log Do not click on the Enable Data Buffering checkbox v To Configure Data Buffering 1 Select Step 5 Data Buffering The system brings up the Data Buffering form Step 1 Security Profile PH O Set up data buffering to the output from the consoles in a Step 3 Port Profile console log file Step 4 Access See Help for more details The previous port specific parameters will be discarded Step 6 System Log Enable Data Buffering M Destination Local Mode
77. from a workstation on the LAN or WAN There is no authentication by default you can configure the system for authentication to be performed by a Radius server a TacacsPlus server or even by a local database You can use either Telnet or ssh a secure shell session Product Models and Components There are two models of the ACS based on the type of power supply e ACS with a dual power supply and two PCMCIA slots e ACS with a single power supply and two PCMCIA slots 2 AlterPath Advanced Console Server July 2005 Product Models and Components There are six models of the ACS based on the number of serial ports e ACS48 e ACS32 ACSI6 e ACS8 ACS4 ACSI The figure below shows AlterPath ACS1 through ACS48 Introduction ACS Setup Diagram ACS Setup Diagram The diagram below shows a typical setup of the AlterPath Console Server S Application Server erver Server AlterPath ACS48 with local authentication Remote Data Buffering 1087 Ethernet Switch oar 108T 108T Router a Access Methods User Telnet SSH TACACS Server Local User Custom Application 4 AlterPath Advanced Console Server July 2005 Chapter 2 Installing the ACS This chapter presents the procedures for installing and setting up the ACS and is organized as follows e Package Contents e Rack Mounting e Installation and Configuration Process Note For configuration procedures using vi or CLI refer to the AlterP
78. g To activate the snmpd services you should go to the PCMCIA Management Network Services section VPN Connections Services System Information Settings Firewall Configuration Host Table SysContact configure ete snmp snmpd conf Static Routes y SysLocation configure etc snmp snmpd conf Access Control SNMPv1 SNMPv2 Configuration Figure 4 27 SNMP Daemon Settings Form Web Manager for Administrators 83 Configuring the ACS in Expert Mode 2 Type in the following System Information as necessary Table 4 23 System Information Settings Field Name Definition SysContact The email of the person to contact regarding the host on which the agent is running e g me Omymachine mydomain SysLocation The physical location of the system e g mydomain Note If you are using SNMPy3 skip steps 2 and 3 proceed to step 4 e To Add an SNMP agent using SNMPv1 SNMPv2 Configuration select the Add button located at the bottom of the view table OR e To Edit an SNMP agent select the Edit button The system invokes the New Modify v1 v2 Configuration dialog box New Mod SNMP v1 v2 ox cancei _Hetp Community Source sss OID A Permission Read Only y 84 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Complete the dialog box as follows Table 4 24 SNMP v1 v2 Configuration Dialog Box Fields Field Name Definition Community
79. groups to which you can assign a user are Admin Read Write Access Regular User Limited R W Access Although root is also a user there is only one root user username root default password tslinux Note If a step does not apply e g edit delete skip to the next step v To Add Users and Groups to the Access List 1 From the top menu bar select Security from the left menu panel select Users and Groups The system brings up the Users and Groups form Security Active Ports Sessions Security Profile Figure 4 35 Users and Groups Form 2 To add a user to the User list OR to add a group to the Group list select the Add button at the bottom of the corresponding list box 3 The system brings up the Add Users and Groups dialog box 100 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode ox cosa Eme User Name Po Password UI Repeat Password II Group Regular User y nonsio y Shell Comments ll 4 Complete the dialog box shown above and then select OK Note All users must be assigned to a group 5 To edit a user or a group from the Users and Groups form select the user or the group you wish to edit from the appropriate listbox and then select the Edit button located that the bottom of the corresponding listbox 6 Repeat step 3 v To Delete a User from a Group 1 To delete a user select the user name you wish to delete from the U
80. h Advanced Console Server July 2005 Configuring the ACS in Wizard Mode The following tables illustrate the properties for each of the Security Profiles The enabled services in each profile is designated with a check mark Note that the Default option will set the parameters to the same as Moderate and the Custom Profile allows for individual configurations Table 4 2 Enabled services to access the ACS box for each security profile Access to Secured Moderate Open Default Custom ACS Telnet Y Y Y 5 e SSH vl Y Y Y S c SSH v2 Y Y Y Y Q Allow SSH S root access zi S HTTP Y Y Y S O HTTPS Y Y Y Y HTTP Y Y Y redirection to HTTPS Web Manager for Administrators 39 Configuring the ACS in Wizard Mode Table 4 3 Enabled services to access the serial ports for each profile Connection to Serial Ports Access to Secured Moderate Open Default Custom Serial Ports SSH to Serial Y Y Y Y 5 Ports E Telnet to Serial Y Y Y 5 Ports lt Q Raw Y Y Y 5 E E S z O Serial Port Authentication Table 4 4 Enabled protocols for each profile shown with a check mark Other Secured Moderate Open Default Custom Services SNMP Y S a RPC Y S 5 ICMP Y Y Y E Q FTP S Eh IPSec S O v To Configure the Security Settings 1 Select Step 1 Security Profile 2 Select a pre defined Security Profile or create a Custom Profile 3 Select apply changes to save the configuration to Flash 40 A
81. hernet ports in the bond to the same Ethernet MAC address which ensures the proper routing of packets across the links Boot Break Signal Checksum Cluster Console Access Server CAS Community Console Console Port 156 To start a computer so that it is ready to run programs for the user A PC can be booted either by turning its power on Cold Boot or by pressing Ctrl Alt Del Warm Boot A break signal is generated in an RS 232 serial line by keeping the line in zero for longer than a character time Breaks at a serial console port are interpreted by Sun servers as a signal to suspend operation and switch to monitor mode A computed value which depends on the contents of a block of data and which is transmitted or stored along with the data in order to detect corruption of the data The receiving system recomputes the checksum based upon the received data and compares this value with the one sent with the data If the two values are the same the receiver has some confidence that the data was received correctly A cluster is a group of one or more computers working as a group to execute a certain task From the user standpoint a cluster acts as a large computer system A CAS has an Ethernet LAN connection and many RS 232 serial ports It connects to the console ports of servers and networking equipment and allows convenient and secure access from a single location The community name acts as a password and is
82. ields for each selected item in the menu AlterPath Advanced Console Server July 2005 Form names The name or title of a form may not necessarily appear on the actual form When this is the case the form is named after its menu selection or form function Select To select is the same as to click your mouse Cross References The ACS User Manual cross references the following Cyclades documents e ACS Advanced Administrator Guide e AlterPath Manager Manual e Cyclades Power Management Manual To access Cyclades product documentation including release notes and updates please visit the Cyclades web site at www cyclades com support downloads php Additional Resources The following sections describe Cyclades offerings including technical training and firmware upgrades Cyclades Technical Training Cyclades offers a suite of technical courses to increase your knowledge of the AlterPath ACS To learn more about Cyclades Technical Training Center and offerings please visit our website at www cyclades com training call us at 1 888 292 5233 or send an email to training cyclades com Cyclades Firmware Upgrades Cyclades offers periodic firmware upgrades for the AlterPath ACS These upgrades are available free of charge to current Cyclades customers Visit http www cyclades com support downloads php acs to download the latest firmware Before You Begin ix AlterPath Advanced Console Server July 2005 Cha
83. iguration The General form is used to define the port profile for the selected port s 1 From the top menu select Ports from the left menu select Physical Ports 108 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode The system invokes the General tabbed form Virtual Ports Ports Status Connection Protocol console ssm Alias Baud Rate Kbps 9600 Flow Control None Data Parity None Stop Bits DCD State bisregara Selected ports 3 Figure 4 41 Serial Ports General Modification Form 2 Complete the form as follows Table 4 31 Serial Port Modification Form Fields Field Name Definition Connection Protocol The connection protocol to be used by the selected port Choices are Console Telnet Console SSH Console Raw Telnet SSHv1 SSHv2 Local Terminal Raw Socket PPP No Auth PPP SLIP CSLIP and Power Management Alias Port alias if applicable Baud Rate Kbps 9600 Kbps is the default rate for most servers Flow Control Choices None Hardware or Software Data The number of data bits Parity Port parity none even or odd Stop Bits The end of the data type Web Manager for Administrators 109 Configuring the ACS in Expert Mode 110 Table 4 31 Serial Port Modification Form Fields Field Name Definition DCD State Data Carrier Detect Signal Regard or Disregard 3 Click on the apply changes button at the bottom of
84. imary DNS Server 192 168 44 21 Gateway IP 192 168 48 1 Network Mask 259 259 292 0 Set to defaults y n n _ a At the prompt enter n to change the defaults Set to defaults y n n n b Press Enter to accept the default hostname otherwise enter your own hostname Hostname CAS C Press Enter to keep DHCP enabled or enter a static IP address By default ACS uses the IP address provided by the DHCP server If your network does not use DHCP then ACS will default to 192 168 160 10 Do you want to use dhcp to automatically assign an IP for your system y n yl d Enter the domain name Domain name cyclades com e Enter the IP address for the Primary DNS domain name server Primary DNS Server 192 168 44 21 f Enter the IP address for the gateway Gateway IP eth0 17 Installation and Configuration Process g Enter the netmask for the subnetwork Network Mask The network configuration parameters appear Current configuration Hostname CAS DHCP disabled System 1P 192 168 51 143 Domain name cyclades com Primary DNS Server 129 168 44 21 Gateway IP 192 168 48 1 Network Mask 255 255 252 0 h Enter y to the prompts shown in the following screen example Are all these parameters correct y n n i To confirm the configuration enter the if config command Note For the procedure on how to configure the ACS from wiz to support Kerberos tickets refer to the ACS Advanced Admi
85. ing complex networks SNMP works by sending messages called protocol data units PDUs to different parts of a network SNMP compliant devices agents store data about themselves in Management Information Bases MIBs and return this data to the SNMP requesters The ACS uses the Net SNMP package http www net snmp org The Net SNMP package contains various tools relating to the Simple Network AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Management Protocol including an extensible agent an SNMP library tools to request or set information from SNMP agents tools to generate and handle SNMP traps a version of the unix netstat command using SNMP and a Tk perl mib browser SNMP is configured with community names OID and user names ACS supports SNMPv1 v2 and v3 The two versions require different configurations SNMPv1 v2 requires community source object ID and the type of community read write read only V3 requires user name Note Check the SNMP configuration before gathering information about ACS by SNMP There are different types of attacks an unauthorized user can implement to retrieve sensitive information contained in the MIB By default the SNMP configuration in ACS cannot permit the public community to read SNMP information v To Configure SNMP 1 Select Networks gt SNMP Daemon Settings The system invokes the SNMP Daemon Settings form ee Host Settings Syslo
86. ion User The user who initiated the port session TTY The name of the serial port 102 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Table 4 29 Active Port Session Fields Field Name Definition From The network machine to which the port is connected Login The time of the last login Idle The time when the port became inactive JCPU The duration of time used by all processes attached to the tty It does not include past background jobs only currently running background jobs PCPU The time used by the current process that is named in the What column What The current process attached to the tty Security Profile gt The first step in configuring AlterPath ACS is to define a Security Profile Security Profile consists of a set of parameters that can be set to control access to the ACS There are three pre defined security profiles Secured Moderate Open and an option to configure a Custom profile A fifth option Default will set the parameters to the same as Moderate See Configuring the Security Profile in Wizard Mode on page 38 for detailed definition of each profile Web Manager for Administrators 103 Configuring the ACS in Expert Mode Step 2 Network Settings Step 3 Port Profile Step 4 Access S Date ffe gt ee ae bala Utero Currently there is NO SECURITY PROFILE set Step 6 System Log You must define a Security Level before proceding with f
87. ity m Server IP A Body Figure 4 53 SNMP Ndotification Form 130 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Table 4 41 SNMP Notification Form Fields Field Name Definition Alarm Trigger The trigger expression used to generate an SNMP trap untitled dropdown field OID Type Value The value that uniquely identifies an object to the SNMP agent Trap Number The trap type defined in the MIB Community The password used to authenticate the traps Server IP The address of the server running the SNMP Body The text or content of the notification 1 Complete the Notification Entry dialog box and select the OK button 2 Select the apply changes button at the bottom of the ACS configuration window to save your configuration Port Alarm Notification You can configure the Notification form to monitor the DCD signal such that the system will generate an alarm in any of the following events e A serial console cable is removed from the console server e A server network equipment attached to the console is powered down e The configuration also enables you to detect if a modem that is in use is still powered on and active 1 From the Notification form select the Action Email SNMP Trap or Pager Click the Add button Enter the Alarm Trigger Port Configure the parameters of the action a oN Select Apply Changes Web Manager for Administrators 131
88. izard Mode 48 3 Add User Microsoft Internet Explorer 1 ioj x ox cancer A User Name ho Password E Repeat Tr Password Group Regular User NonBio y shell Comments Figure 4 11 Add User Dialog Box 3 Enter the necessary User information into the following fields Table 4 6 Add User fields Field Name Definition User Name Name of the ACS user Password Password to be used by the user to access ACS Repeat Password Re type the password Group Select the user group to which the user belongs There are two default groups with the following associated access rights Admin Read Write Regular User Read Only dropdown list Select whether the user of this group is a NonBio or a BioUser The NonBio group is the correct choice for regular users The BioUser group should only be selected if authentication will be made through the Cyclades AlterPath Bio biometric authentication AlterPath Advanced Console Server July 2005 Configuring the ACS in Wizard Mode Table 4 6 Add User fields Field Name Definition Shell Text string you wish to use as part of the shell prompt for the current user Comments Comments about the current user Note To define a new group select the Expert button to switch to the Expert Mode and then select Security gt Users and Groups 4 Select the OK button when done 5 From the bottom of the main window select the apply chang
89. l defined naming syntax to specify the variables to the SNMP agent Object names in this syntax are called Object Identifiers Object IDs or OIDs OIDs are series of numbers that uniquely identify an object to an SNMP agent OIDs are arranged in a hierarchical inverted tree structure The OID tree begins with the root and expands into branches Each point in the OID tree is called a node and each node will have one or more branches or will terminate with a leaf node The format of OID is a sequence of numbers with dots in between There are two roots for Object Identifiers namely iso and ccit iso starts with 1 and ccit starts with 0 Most Object Identifiers start with 1 3 6 1 where 1 iso 3 org 6 dod 1 internet The Internet sub tree branches into mgmt and private To understand the concept of relative and absolute Object Identifiers let us consider the AdventNet Object Identifier 1 3 6 1 4 1 2162 It specifies the path from the root of the tree The root does not have a name or a number but the initial 1 in this OID is directly below root This is called an absolute OID However a path to the variable may be specified relative to some node in the OID tree For example 2 1 1 7 specifies the sysContact object in the system group relative to the Internet 1 3 6 1 node in the OID tree This is called a relative OID This is a CAS feature that allows capture of console data even when there is no one connected to the port Se
90. lable cords are shown in the following rows Talk with a Cyclades sales representative if the power cable you need is not listed in this table or if you have special requirements CABO0010 NEMAS 15P Flat United States and other blades with round countries grounding pin CAB0037 Schuko Round pin European and other Y y attachment plug countries CAB0055 Oblique flat blades Australia New Zealand and lt p with ground other countries CAB0056 Rectangular blade UK Ireland and other CAB0104 plug countries e Installing the ACS R Item P N Description Purpose CABO0278 Flat blades with Japan round grounding pin 4 ADB0017 RJ45 to DB25F To connect the console port C crossover adapter to a computer that has a DB 25 male connector 5 ADB0025 RJ45 to DB25M To connect the console port C crossover adapter to a computer that has a DB 25 female connector 6 ADB0036 RJ45 to DB9F To connect the console port C LJ a crossover adapter to a computer that has a DB 9 4 i connector 7 i ADB0039 Sun Netra To connect the console port C D crossover adapter to a Sun Netra server or other devices with the same pinout configuration 8 CAB0018 RJ45 to RJ45 7ft Use for the following CATS cable To connect a device or an IPDU to a serial port To connect an Ethernet port to the LAN e To connect a terminal to a console port AlterPath Advanced Console Server July 2005 R It
91. lash the following fields are used A Network Access Method Configuration je oO x A ox canei mot Compact Flash y M Enable Use for data buffering Table 4 20 Form Fields for a Compact Flash Card Field Name Definition PCMCIA Card Select Compact Flash from the Pull down box Enable Check box to enable the compact flash Web Manager for Administrators 77 Configuring the ACS in Expert Mode Table 4 20 Form Fields for a Compact Flash Card Field Name Definition Use for Data Buffering Check box to use the compact flash for data buffering Access Method Wireless LAN If the selected Access Method is Wireless LAN the following fields are used 1 Microsoft Internet Explorer loj x a ox Cancel meto Wireless LAN y IP Address Network Mask MyPrivateNet 2 ESSID Channel 0 Encrypted Table 4 21 Form Fields for a Wireless LAN Card Field Name Definition Unlabeled Pull down box to select the type of PCMCIA card that you are using PPP Check box to enable point to point protocol Local IP The local IP address of the PCMCIA card Remote IP The remote IP address of the PCMCIA card Call Back Check box to enable the callback security feature Phone Number The phone number that the ACS uses to call back What is VPN If you already understand how VPN works skip this section and proceed to the next procedure Network gt VPN Connections 78 A
92. llows Table 4 44 Backup Configuration Form Fields Storage Device Field Name Definition Default Configuration The system uses the configuration in the storage device but does not override the internal flash configuration after reboot Replace Configuration The system saves the configuration in the storage device with a flag REPLACE that is used by the RESTORECONF utility 4 Click on Save 5 Click on Apply Changes Upgrade Firmware The Upgrade Firmware form allows you to upload the ACS firmware from the Cyclades website to the ACS To upgrade the ACS firmware follow the procedure below 138 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode 1 Select Administration from the top menu and then select Upgrade Firmware from the left menu The system brings up the Upgrade Firmware form Administration System Information Notifications The upgrade will only be performed if Time Date Upgrade Now button is pressed Boot Configuration See Help for more details Backup Config Type FTP FTP Site Reboot Username Password File version Run Checksum Figure 4 58 Upgrade Firmware Form 2 Complete the form as follows Table 4 45 Upgrade Firmware Form Fields Field Name Definition Type The method of upload FTP Site The address of the FTP site Username Username of the person who is doing the upload Password Password associated with the Username
93. ls Usage setup of the ACS either as a Console Access Server CAS a Terminal Server or a Remote Access Server Remote Authentication Dial In User Service is a client server protocol and software that enables remote access servers to communicate with a central server to authenticate dial in users and authorize their access to the requested system or service RADIUS allows a company to maintain user profiles in a central database that all remote servers can share Reduced Instruction Set Computer This describes a computer processor architecture that uses a reduced set of instructions and achieves performance by executing those instructions very fast Most UNIX servers Sun Sparc HP IBM RS6000 Compaq Alpha were designed with a processor using a RISC architecture The Intel x86 architecture Root is the term for a very highly privileged administrative user particularly in unix environments When an ISP grants you root access it means you will have full control of the AlterPath Advanced Console Server July 2005 Routing Table RPC Secure Shell SSH Server Farm SMTP SNMP SNMP Traps Glossary server With full control you will be able to install any software and access any file on that server The Routing Table defines which interface should transmit an IP packet based on destination IP information Short for Remote Procedure Call A type of protocol that allows a program on one computer to execute a
94. lterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode A VPN or Virtual Private Network lets the Console Server and a whole network communicate securely when the only connection between them is over a third network which is not trustable The method is to put a security gateway machine in the network and create a security tunnel between the Console Server and this gateway The gateway machine and the Console Server encrypt packets entering the untrusted net and decrypt packets leaving 1t creating a secure tunnel through it Often 1t may be useful to have explicitly configured IPsec tunnels between the Console Server and a gateway of an office with a fixed IP address in this case every machine on the office network would have a secure connection with the Console Server or between the Console Server and the Console Server administrator machine which must in this case have a fixed IP address You can add this connection descriptor to both the Console Server and the other end This is the advantage of using left and right instead of using local remote parameters If you give an explicit IP address for left and left and right are not directly connected then you must specify leftnexthop the router which Console Server sends packets to in order to get them delivered to right Similarly you may need to specify rightnexthop vice versa The Role of IPSec IPsec is used mainly to construct a secure connection t
95. lterPath Advanced Console Server July 2005 Configuring the ACS in Wizard Mode Note Before proceeding forward to Network Settings the following dialog box appears The protocols and access methods for the Serial Ports must match the selected Security Profile To configure parameters for all Serial Ports see Port Profile on page 43 To modify services for each Serial Port see Physical Ports on page 106 Mrasoft Internet Explorer g x A Changing Security Level does not affect Serial Ports configuration Please make sure the current protocols and access method for al Seria Ports match the Security Level chosen Network Settings The network settings form allows configuring parameters to make ACS accessible over the network v To configure the Network Settings 1 Select Step 2 Network Settings The system brings up the DHCP page shown below By default DHCP is active which means that the system is configured to use the DHCP server Web Manager for Administrators 41 Configuring the ACS in Wizard Mode Step 1 Security Profile Set up the network parameters Step 3 Port Profile Select the DHCP checkbox for automatic configuration Step 4 Access Uncheck the DHCP box to perform manual configuration Step 5 Data Buffering See Help for more details Step 6 System Log DHCP M Figure 4 6 Network Parameters with DHCP enabled 2 If you are using DHCP proceed to Step 3 Port Profile if not click
96. m products 3 alterpath_acs or go to www cyclades com gt Products gt IT Infrastructure Management gt AlterPath ACS gt Click here for a list of supported PCMCIA cards You can insert a card at any time and the corresponding driver should load automatically Before removing a card however you must configure the PCMCIA form to eject the card and stop the system from using the card v To Configure PCMCIA Cards 1 Select Network gt PCMCIA Management The system brings up the PCMCIA Management form AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode PCMCIA Figure 4 25 PCMCIA Management Form 2 Insert the card into the PCMCIA slot and then select the Insert button 3 To configure the card select the Configure button 4 The system brings up the PCMCIA Configuration dialog box 3 Slot 1 Microsoft Internet Explorerja E Modem ii r PPP From the pull down menu select the type of card that you are using o 6 Complete the rest of the dialog box See the succeeding PCMCIA Configuration Dialog Boxes section for information about each input field Click on the OK button when done Click on apply changes to save your configuration Web Manager for Administrators 73 Configuring the ACS in Expert Mode 74 PCMCIA Configuration Dialog Boxes The ACS supports the following types of PCMCIA cards Modem ISDN e GSM Ethernet e Compact Flash e Wireless LAN
97. m the left menu select Backup Configuration The system brings up the Backup Configuration form Web Manager for Administrators 135 Configuring the ACS in Expert Mode Administration System Information Notifications Save Load Time Date Type FTP x Upgrade Firmware z Reboot Sono Path and Filename Username Boot Configuration Password Figure 4 56 Backup Configuration Form 2 Complete the form as follows Table 4 43 Backup Configuration Form Fields Field Name Definition Type Type of backup FTP or Storage Device Server IP IP address of the FTP server Path and Filename Path and filename of the FTP server Username Username of the person who is doing the backup Password Password associated with the Username Note Read the succeeding section Backup and Restore Procedure for a more detailed explanation of the fields 3 Select Save to FTP Server or Upload from FTP Server as appropriate 136 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode v Backup and Restore Procedure For backup purposes you can give the configuration backup file a name according to your company s naming convention From the Backup Configuration form fill in the fields with the server name i e the IP address of your workstation if you have just installed an FTP server in it Username and Password for a valid username defined in your FTP server and the Path an
98. ministrator who is responsible for configuring the ACS Web Manager and its users For information on how to configure ACS using vi or Command Line Interface CLD please consult the ACS Advanced Administration Guide The ACS Web Manager provides two modes of operation Wizard and Expert This chapter describes the functionality of the Web Manager in the two modes of operation and details the menu selections available under each mode If you are a regular user refer to Chapter 3 ACS for Regular Users Logging In 1 Connect your internet browser to the Console Server by typing in the Console Access Server s IP address e g http 10 0 0 0 in the browser s address URL field Note To determine the IP address of the ACS switch on the ACS connected to the Ethernet where there is a DHCP server When you inquire based on the MAC address the 12 digit hexadecimal number located at the bottom of the ACS unit the server will provide the appropriate IP address If there is no DHCP server use the default static IP address that is pre configured in the ACS 192 168 160 10 For more detailed information see Chapter 2 Installing the ACS The system brings up the ACS Login page 32 AlterPath Advanced Console Server July 2005 Logging In Login usemame password Figure 4 1 Login page 2 Log in as root and type in the root password The default password is tslinux Warning If you have performed
99. n negotiated plain socket connections Flow Control The method of flow control used by the attached devices Hardware Software or None Baud Rate The serial speed on each console port which should match the equipment you will connect to The recommended Baud Rate is 9600 Data Size Number of data bits used by the attached devices 5 6 7 or 8 Parity Parity used by the attached devices None Odd or Even Stop Bits Number of stop bits used by the attached devices Authentication Required Selecting this checkbox sets the system to require authentication to access the ports This is done in the local database in the ACS Note f you require individual Serial Port Authentication then you must add users through Wizard Step 4 Access 3 Select apply changes to save configuration to Flash 4 Select the Next button or proceed to the next section Step 4 Access Access Configure which users are allowed access to the ports By default any user can access any port as long as they have a valid user ID and password Web Manager for Administrators 45 Configuring the ACS in Wizard Mode Note To grant users access to specific ports switch to the Expert Mode then go to Security gt Users and Groups From this window you can Change a User Password e Add a user e Delete a user v To Configure User Access to Serial Ports 1 Select Step 4 Access The system brings up the Access screen Step 1
100. n an ISP server accesses network services on behalf of a dial up user Short for Maximum Transmission Unit the largest physical packet size measured in bytes that a network can transmit Any messages larger than the MTU are divided into smaller packets before being sent Every network has a different MTU which is set by the network administrator On Windows you can set the MTU of your machine This defines the maximum size of the packets sent from your computer onto the network Ideally you want the MTU to be the same as the smallest MTU of all the networks between your machine and a message s final destination Otherwise if your messages are larger than one AlterPath Advanced Console Server July 2005 Network Mask NES Glossary of the intervening MTUs they will get broken up fragmented which slows down transmission speeds Trial and error is the only sure way of finding the optimal MTU but there are some guidelines that can help For example the MTU of many PPP connections is 576 so if you connect to the Internet via PPP you might want to set your machine s MTU to 576 too Most Ethernet networks on the other hand have an MTU of 1500 A 32 bit number used to group IP addresses together or to indicate the range of IP addresses on a single IP network subnet supernet There is a group of addresses assigned to each network segment For example the mask 255 255 255 0 groups together 254 IP addresses If we have a
101. nd the system does not recover on its own A common problem is for a machine or operating system to lock up if two parts or programs conflict or in an operating system if memory management trouble occurs In some cases the system will eventually recover on its own but this may take an unknown and perhaps extended length of time A watchdog timer can be programmed to perform a warm boot restarting the system after a certain number of seconds during which a program or computer fails to respond following the most recent mouse click or keyboard action The timer can also be used for other purposes for example to actuate the refresh or reload button in a Web browser if a Web site does not fully load after a certain length of time following the entry of a Uniform Resource Locator URL AlterPath Advanced Console Server July 2005 Glossary 169 170 AlterPath Advanced Console Server July 2005 Index A Access Configuration Wizard Mode 45 Access form Ports 111 Access Method Compact Flash 77 Ethernet 76 GSM 76 ISDN 75 Modem 74 Wireless LAN 78 Access to ACS 39 Access to Serial Ports 40 ACS firmware 138 Active Port Sessions 102 add 81 Add Edit User dialog box 62 Adding a Chain 88 Adding a Rule 94 Adding Users and Groups to the Access List 100 Administration 125 Allow Multiple Sessions 118 AlterPath ACS Login page 32 Apply Changes button 37 Authentication LDAP or LdapDownLocal 114 Radius 114 Authentication Method
102. net 9600 8N1 Figure 4 39 Physical Ports Form This form allows you to e Modify all or only selected ports e Enable or disable selected ports 2 To modify selected ports select the port you wish to modify from the Physical Ports Modification form and then click on the Modify Selected Ports button OR 3 To modify all ports click on the Modify All Ports button 4 Proceed to the next section Configuring Ports and select the tabbed form you wish to configure Web Manager for Administrators 107 Configuring the ACS in Expert Mode v To Associate an Alias to a Port A name alias can be associated to a port when it s individually selected for modification To associate an alias to a port perform the following steps 1 While in Expert Mode go to Ports gt Physical Ports 2 From the Physical Ports Selection form select the port to configure and then click on the Modify Selected Ports button 3 The system displays the Modify Selected Port form Connection Protocol Console Telnet y Alias tstl Baud Rate Kbps 2600 Flow Control None y Data Parity None y Stop Bits Selected ports 2 Done Figure 4 40 Port Modification Form Note The Alias field cannot be set if you select the Modify All Ports button 4 From the Alias field enter the port alias using one or more strings separated by spaces 5 Click on the apply changes button to save your configuration General Port Conf
103. ng M Destination Remote y NFS File Path Record the timestamp in the data buffering file I Show Menu Show all options y 5 Click on the apply changes button The system can filter messages based on their content and perform an action e g to send an e mail or pager message To configure data buffering to send Web Manager for Administrators 51 Configuring the ACS in Wizard Mode a notification alarm you must use the Notifications form Go to Expert Mode Administration gt Notifications System Log The System Log form allows you to configure one or more syslog servers to receive syslog messages that are generated by the ACS The ACS sends syslog messages to all syslog servers that are defined here Note To configure syslog with data buffering features for specific ports switch to the Expert Mode and then go to Ports gt Physical Ports gt Data Buffering v To Configure Syslog servers 1 Select Step 6 System Log The system brings up the System Log form Step 1 Security Profile Step 2 Network Settings Step 3 Port Profile Step 4 Access See Help for more details Step 5 Data Buffering Configure external syslog server location to receive unit s Facility Number Local 7 New SysLog Server Figure 4 13 Syslog Form 2 From the System Log form select the Syslog facility number that the ACS will use to send out syslog messages 52 AlterPath Advanced Console Server July 200
104. ng with further configuration Please choose from the three preset security levels Secured Moderate or Open You can also configure a customized security profile Figure 4 2 Security Profile Setup Shown above is a typical page of the ACS web interface in Wizard Mode The user entry panel or form varies depending on the selected menu item The ACS uses forms and dialog boxes i e pop up windows that prompt you for an answer or command for data entry Expert Mode Designed for advanced users this is the default mode when you log in to the ACS If you are in the Wizard mode you can change to this mode by clicking on the Expert button at the bottom of the menu panel Shown below is a typical ACS screen in Expert Mode The main difference between the two modes is the addition of a top menu bar in the Expert Mode to support more detailed and customized configuration In Expert mode the top menu bar contains the primary commands and the left menu panel contains the secondary commands Based on what you select from the top menu bar the left menu selections will change accordingly Web Manager for Administrators 35 ACS Web Manager Elements Virtual Ports Ports Status Connection Protocol Console Telnet Ala LinuxServer Baud Rate Kbps 9600 Flow Control None 7 Data Parity None Stop Bits DCD State Figure 4 3 Serial Ports Setup Occasionally an Expert Mode menu selection will comprise multiple
105. nistration Guide 9 After the initial configuration you can configure the network further by using any of the following methods Web Manager Command Line Interface CLI via SSH AlterPath Manager if installed on your network Note To use the ACS Web Manager ask your system administrator for the IP address By default ACS uses the IP address provided by the DHCP server If your network does not use DHCP then ACS defaults to 192 168 160 10 Configure your ACS to connect to this address and run the Web Manager 18 AlterPath Advanced Console Server July 2005 Installation and Configuration Process Configure the ACS in Wizard Mode e Proceed to Chapter 4 Web Manager for Administrators and complete the procedure for configuring ACS in Wizard Mode Test the Configuration e Log in as a regular user and connect to a port Check the other features for example Data Buffering Power Management and so on as discussed in Chapter 3 ACS for regular users Note To create new users see Wizard Mode Step 3 Access page 4 10 of Chapter 4 Web Manager for Administrators Configure the ACS in Expert Mode Proceed to Chapter 4 Web Manager for Administrators and continue with configuration using the Expert Mode Save the Changes Click on the apply changes button located on the bottom of the ACS Web Manager Configuration screen to save your configuration to Flash Installing the ACS 19
106. nsole Server July 2005 Configuring the ACS in Expert Mode The system invokes the following dialog box 3 Add Option Microsoft Internet Explorer 0 x A ox w up Title Action Command Type in the menu title and or action to the corresponding entry fields Verify your entry or edits from the Menu Options list of the Terminal Profile Menu form To enter or edit another command repeat steps 2 through 4 Click on the apply changes button located at the bottom of the configuration window Network The Network menu allows configuring the ACS generic network setting as well as additional parameters as described and illustrated in each section below The following are the available options Host Settings Syslog PCMCIA Management VPN Connections SNMP Daemon Settings Firewall Configuration Host Table Static Routes Web Manager for Administrators 67 Configuring the ACS in Expert Mode Host Settings The Host Settings form allows you to configure the network settings for ACS v To Configure Host Settings 1 Select Network gt Host Settings The system brings up the Host Settings form M DHCP Host Name Console Banner cas Atterpath acs Figure 4 22 Network Host Settings Form with DHCP enabled By default the DHCP field checkbox is checked 2 To disable DHCP and enter the host settings manually clear the DHCP checkbox The system should add the following fields to your form
107. o enable notification alarms for data Data Buffering buffering unlabeled view table List of alarm types and triggers 126 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Table 4 38 Notification Form Fields Field Name Definition unlabeled dropdown list Pull down menu of notification methods select Email Pager or SNMP Trap 3 Select the Add button The system brings up the Notifications Entry dialog box The type of dialog box that appears will depend on the notification method that you select from the Notifications form Email Notifications If you selected Email as the notification method the following dialog box is used Web Manager for Administrators 127 Configuring the ACS in Expert Mode 128 3 Notifications Entry Microsoft Internet Explorer Subject A Body SMTP Server IP m SMTP Port P Figure 4 51 Email Notification Form Table 4 39 Email Notification Form Fields Field Name Definition Alarm Trigger untitled dropdown field To From Subject Body SMTP Server IP SMTP Port The trigger expression used to generate an alarm The email for the designated recipient of the alarm notification The IP address of the SMTP server The port used by the SMTP server AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Pager Notifications If you selected Pager as the notifica
108. omplete the form as follows Table 4 34 Multi User Form Fields Field Name Definition Allow Multiple Sessions Select from No Yes show menu Read Write do not show menu ReadOnly do not show menu Sniff Mode Select from Out In In Out and No Menu Hotkey The hotkey for accessing the menu Notify Users Check box to notify users of session access When multiple sessions are allowed for one port ACS will accept only one common session and one sniffer session In this setting the behavior of the ACS is as follows e The first user to connect to the port opens a common session e From the second connection on only Admin users are allowed to connect to that port e The ACS will send a hotkey menu to the administrator s Power Management The Power Management form of the Ports menu is used to enable power management for the current port add and delete power management ports and assign user and group access to these ports v To Configure Ports for Power Management 1 Select Ports from the top menu select Physical Ports from the left menu select Power Management from the row of tabs The system brings up the Power Management form 118 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Power Management Power Management Port Outlet Number Ma EA Power Management Key C C o a Enable Power Management on this port M Allow All Users Allow Users Groups Sele
109. on the checkbox to deselect DHCP and enter your network settings manually The Network Settings entry fields should appear as follows 42 AlterPath Advanced Console Server July 2005 Configuring the ACS in Wizard Mode Step 1 S Profil ibi Set up the network parameters Select the DHCP checkbox for automatic configuration Step 3 Port Profile Uncheck the DHCP box to perform manual configuration Step 4 Access See Help for more details Step 5 Data Buffering Step 6 System Log Host Name CAS IP Address Network Mask 192 168 48 11 255 255 252 0 Domain Name cyclades com DNS Server Gateway IP 192 168 44 21 192 168 48 1 Figure 4 7 Network Parameters with DHCP disabled 3 Enter the network information e Host Name e IP addresses e Network Mask e Domain Name DNS Server e Gateway IP 4 Select apply changes to save configuration to Flash 5 Select the Next button OR proceed to Step 3 Port Profile section Port Profile The Port Profile configures your Console Access Profile CAS defining the protocol and type of command line interface you will use to access the ACS The Port Profile controls the speed data size parity and stop bits of all ports Web Manager for Administrators 43 Configuring the ACS in Wizard Mode It sets the flow control to hardware software or none and sets the DCD signal and tty after the system establishes a socket connection to that serial port Note In Wi
110. on from the dialog box 6 Verify your entry or modification from the respective tables of the SNMP Configuration form 7 Select the apply changes button to complete the procedure Firewall Configuration Firewall configuration also known as IP filtering refers to the selective blocking of the passage of IP packets between global and local networks The filtering is based on rules that describe the characteristics of the packet e g the contents of the IP header the input output interface or the protocol This feature is used mainly in firewall applications to filter the packets that could potentially crack the network system or generate unnecessary traffic in the network Structure of IP Filtering The Firewall Configuration form is structured on two levels AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode e The view table of the Firewall Configuration form which contains a list of chains e The chains which contain the rules that control filtering Chain The filter table contains a number of built in chains and can include any other chains that you add user defined chains through the Add Chain dialog box User defined chains are called when a rule which is matched by the packet points to the chain The built in chains are called according to the type of packet and are classified as follows e INPUT For packets coming into the ACS box itself FORWARD For packets being routed
111. onfiguration e Customize configuration using the Web Manager in Expert Mode e Save Changes Note You can configure ACS using the command line interface alone See the ACS Advanced Administration Guide to configure ACS using CLI Installation The following procedure describes the necessary physical connection in order to connect the ACS to the network v To Install ACS and Connect to the Network 1 Plug the power cable into the ACS 2 Insert the female end of the black power cable into the power socket on the ACS and the 3 prong end into a wall outlet Caution To help prevent electric shock plug the ACS into a properly grounded power source The cable is equipped with a 3 prong plug to help ensure proper grounding Do not use adapter plugs or remove the grounding prong from the cable If you use an extension cable use a 3 wire cable with properly grounded plugs Installing the ACS 13 Installation and Configuration Process 14 Caution The AlterPath Advanced Console Server must be plugged into a receptacle protected by an appropriate listed circuit breaker 3 Connect the console cable Construct a Console Cable out of the RJ 45 straight through cable and the appropriate adapter provided in the product box All adapters have an RJ 45 connector on one end and either a DB25 or DB9 connector on the other end male or female Connect this cable to the port labeled Console on the ACS with the RJ
112. ort 1 From the drop down menu select the port to which you wish to connect and then click on Connect OR To connect to the ACS box select the radio button Connect to ACS and then click on Connect Depending on your selection the system either opens a Java connection to the port selected or launches an SSHv2 connection to the ACS box In the sample screen below the system displays a Java window after connecting to the selected server ACS for Regular Users 23 Using the Command Line Interface CLI A Port 1 Microsoft Internet Explorer Connected to 200 200 200 1 7001 SendBreak Disconnect Figure 3 3 SSHv2 or Java Connection Using the Command Line Interface CLI 24 Operating the terminal varies according to whether the selected port is configured for Telnet access or for SSH access To log in see the log in instructions for Telnet or SSH in the next section of this chapter Click in the terminal window and start entering commands To send a break to the terminal click on the SendBreak button The upper right hand corner of the browser Java window shows two icons Reconnect amp Close ES Select the left icon to reconnect to the server select the right icon to end the session or disconnect from the Java window AlterPath Advanced Console Server July 2005 Using the Command Line Interface CLI Logging into the Terminal Telnet Access To open a telnet session to
113. ou that a configuration parameter has changed and it requires to be saved Figure 4 4 Configuration parameters unsaved indicator Unless you do not need to save your configuration be sure to select the apply changes button to ensure that your changes are saved to Flash Web Manager for Administrators 37 Configuring the ACS in Wizard Mode Configuring the ACS in Wizard Mode The Wizard Mode configuration is comprised of six steps Security Profile on page 38 Network Settings on page 38 Port Profile on page 43 Access on page 45 Data Buffering on page 49 System Log on page 52 Security Profile A Security Profile consists of a set of parameters that can be set to control access to the ACS The ACS offers three pre defined security profiles Secured Moderate Open and an option to configure a Custom profile A fifth option Default sets the parameters to the same as Moderate Note The first step in configuring AlterPath ACS is to define a Security Profile Step 2 Network Settings Step 3 Port Profile Step 4 Access Step 5 Data Buffering Currently there is NO SECURITY PROFILE set Step 6 System Log You must define a Security Level before proceding with further configuration Please choose from the three preset security levels Secured Moderate or Open You can also configure a customized security profile Figure 4 5 Security Profile Setup form 38 AlterPat
114. oundation Sun Sun Microsystems Java J2SE Solaris are trademarks or registered trademarks of Sun Microsystems Inc in the United States and other countries UNIX is a registered trademark of The Open Group in the United States and other countries All rights reserved This document may not in whole or part be copied photocopied reproduced translated or converted to any electronic or machine readable form without the prior written consent of Cyclades Corporation Contents Before You Begins conan oien aia V A eon eaa se a aore Sae in vi Document Organization si vi Related DOCUMENTS terien n T ETA tan eta vii Typographical Conventions cooocconocccnoncccnnncnonnnanonnnnnononcnonnnancnnnccnonnnnnns vii Naming Conventions mesial drid e iisas viii Cross References uti es E rd oe ao ix Additional Resources viii dees ix Cyelades Technical Trainin senere ieie antes oprectevenee ix Cyclades Firmware Upgrades ss soeeesseessesssesseeesseeesresseessereseeessees ix Chapter 1 IntroductioON oooncconcccnonoccncncnnnnnnenennonnnos 1 ACS Access and Configuration ssesssesssesssseeesseessressersseresseeesseesseesse 2 Product Models and Components coocococccocccnocncnoncnonononcnonn nono nononnnnnncnnnnnns 2 ACS Setup Diagram A Bad eee 4 Chapter 2 Installing the ACS ooooooccccccccccconcncncnnnonss 5 Package Contents ote it ss 6 Rack Mounting the ACS ui datnt tuoi ier ants 10 Ad A N 11 Default Configuration Par
115. pes of devices including network cards NICs The PCMCIA 2 1 Standard was published in 1993 As a result PC users can be assured of standard attachments for any peripheral device that follows the standard A port is a 16 bit number the allowed range being 1 through 65535 used by the TCP and UDP protocols at the transport layer Ports are used to address applications services that run on a computer If there was only a single network application running on the computer there would be no need 163 PPP Profile RADIUS RISC Root Access 164 for port numbers and the IP address only would suffice for addressing services However several applications may run at once on a particular computer and we need to differentiate among them This is what port numbers are used for Thus a port number may be seen as an address of an application within the computer Point to Point Protocol This protocol is a way to connect your computer to the Internet over telephone lines PPP is replacing an older protocol SLIP as it is more stable and has more error checking features PPP has been a widely used Internet standard for sending datagrams over a communications link The PPP standard is described in RFC 1661 by the Point to Point Working Group of the Internet Engineering Task Force IETF PPP is commonly used when remote computers call an Internet service provider ISP or a corporate server that is configured to receive incoming cal
116. provides other necessary information to guide you in your day to day Operations of the ACS Audience This manual is intended for System administrators and regular users who are responsible for the daily administration and operation of the AlterPath Advanced Console Server using the Web Manager interface While users may use any available method to configure the ACS the ACS Web Manager is primarily designed for users who are new to Linux or UNIX with a primarily PC Microsoft background The user is expected to have a basic knowledge of networking and using a graphical user interface For users who wish to configure ACS using vi or Command Line Interface CLD or read about other advanced features of the ACS please refer to the ACS Advanced Administration Guide Document Organization vi This manual is organized as follows 1 Introduction Defines and explains the overall product features and uses of ACS 2 Installing the ACS Explains the procedure for installing and setting up ACS 3 ACS for Regular Users Explains how to access devices and operate the web interface This chapter is designed for the ACS regular user 4 Web Manager for Presents the procedures for configuring the Administrators ACS using the web interface All the procedures follows the menu structure of the entire web interface in Wizard Mode and Expert Mode Appendix A Summarizes the Hardware Specifications of the AlterPath Advanced Console Server
117. pter 1 Introduction The AlterPath Console Server ACS comes from Cyclades line of Console Access and Terminal Servers designed to allow local and dial in access for in band and out of band network management Modeled after the Cyclades TS line of console server the ACS adds the following advanced features e PCMCIA slots that support standard interface cards Ethernet Modem and wireless LAN e Optional dual entry redundant power supply AC DC for extra reliability e Secure clustering for up to 1024 devices SSH v2 RADIUS authentication IPSec IP filtering and user access lists per port e Console management supports Windows Server 2003 EMS protocols e Data buffering Event notification and a selection of direct access methods to serial ports The Alterpath ACS is available in 1 4 8 16 32 and 48 port models that fit in 1U of rack space As with most Cyclades products the ACS runs an embedded version of the Linux operating system ACS Access and Configuration ACS Access and Configuration You can access the ACS using any of the following three methods e Web Browser e Console directly connected to the ACS Telnet SSH over a network You can configure ACS by using any of the following user interfaces e Web Browser e VI Editor e Wizard Command Line Interface CLI With the ACS set up as a Console Access Server you can access a server connected to the ACS through the server s serial console port
118. quipment in a rack should be such that the amount of air flow required for safe operation of the equipment is not compromised Mechanical Loading Mounting of the equipment in the rack should be such that a hazardous condition is not achieved due to uneven mechanical loading Circuit Overloading Consideration should be given to the connection of the equipment to the supply circuit and the effect that overloading of circuits might have on overcurrent protection and supply wiring Appropriate consideration of equipment nameplate ratings should be used when addressing this concern 144 AlterPath Advanced Console Server July 2005 Reliable Earthing Reliable earthing of rack mounted equipment should be maintained Particular attention should be given to supply connections other than direct connections to the branch circuit such as power strips or extension cords Safety Precautions for Operating the ACS Please read all the following safety guidelines to protect yourself and your AlterPath Console Server Caution Do not operate your ACS with the cover removed Caution To avoid shorting out your ACS when disconnecting the network cable first unplug the cable from the Host Server unplug external power if applicable equipment and then unplug the cable from the network jack When reconnecting a network cable to the back equipment first plug the cable into the network jack and then into the Host Server equipment
119. r Profile Table 4 11 Ports Menu Menu Selection Use this menu to Physical Ports Virtual Ports Port Status Modify ports settings for individual or all ports Physical Ports is composed of five configuration forms as identified by their tab names General Access Data Buffering Multi User Power Management and Other Add edit or delete port slaves Shows the current status of each port The information provided here are RS232 Signal Status and user connected to each port Table 4 12 Administration Menu Menu Selection Use this menu to System Information Notifications Time Date Boot Configuration View summary information about the system e g Kernel CPU memory etc Configure the system to deliver alarm notification by email pager or snmp trap define alarm triggers set data buffering to send notification Set the unit s date and time Defines the settings for loading the operating system in the event that the ACS fails to boot successfully Web Manager for Administrators 55 Configuring the ACS in Expert Mode Table 4 12 Administration Menu Menu Selection Use this menu to Backup Configuration Use a FTP server to save and retrieve your ACS configuration use a storage device to store your configuration Upgrade Firmware Upload upgrade new firmware Reboot Reboot the ACS system Applications Connect The Connect form which launche
120. res and other information that can be used for audit trailing purposes You also use this form to delete syslog servers v To Configure Syslog 1 Select Network gt Syslog The system brings up the Syslog form Network Host Settings PCMCIA Management ns Facility Number Local 7 eee Figure 4 24 Network Syslog Form Web Manager for Administrators 71 Configuring the ACS in Expert Mode 72 2 Complete the form as follows Table 4 15 Field Name Definition Facility Number Facility number to identify the location of the Syslog Server New Syslog Server Name of the Syslog Server that you wish to add Syslog Servers List of all Syslog Servers connected to ACS 3 To add a new Syslog Server type in the name of the server in the New Syslog Server field and then select the Add button 4 OR 5 To delete a Syslog Server from the Syslog Servers list box select the server you wish to delete and then select Delete 6 Select apply changes to save your changes to Flash PCMCIA Management The PCMCIA Management form allows you to configure the types of PCMCIA card that are installed in either one or both of the PCMCIA slots ACS supports several PCMCIA cards including modem ISDN wireless and wired network cards Compact Flash and IDE drives for data buffer storage Note For a list of the supported PCMCIA cards refer to the AlterPath Advanced Console Server web site at http www cyclades co
121. reshold 1 100 amps for that master or slave unit 4 Click on the apply changes button at the bottom of the ACS application window Software Upgrade The Software Upgrade form of Power Management allows you to upgrade the Power Management software for a selected serial port The first line of the form shows the latest software version available The presence of an Upgrade button indicates that a new software version for that master or slave port is available To upgrade the software for a selected port perform the following steps 64 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode 1 Goto the Cyclades web site and enter the Download Drivers area Download the latest AlterPath PM firmware to the tmp folder in the ACS box Be sure to name the firmware pmfirmware otherwise the ACS should not detected it Note that you cannot copy the firmware image to the ACS unit through the web interface you must do it via SSH or by accessing the console port 2 From the top menu bar select Applications from the left menu panel select Power Management from the tabs select Software Upgrade The system brings up the Software Upgrade form Latest software version available 1 2 1 Refresh Serial Port2 Name PowerStrip2 Number of Units 2 Master Unit Software Version 1 1 00 Update First Slave Software Version 1 1 00 Update Serial Port3 Name PowerStrip3 Number of Units 2
122. ress field and the host name in the Name field and then select the OK button 6 To delete a host select the host you wish to delete from the Host Table form and then select the Delete button from the form 7 Select the apply changes button to save your configuration to Flash 96 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Static Routes The Static Routes form allows you to manually add routes The Routing Table defines which interface should transmit an IP packet based on destination IP information Static routes are a quick and effective way to route data from one subnet to another You can add or edit a hard coded static route by clicking on the corresponding buttons They ll bring you to a dialog box to enter the route to be added To delete a static route highlight the route and then select the Delete button v To Configure Static Rules 1 Select Network gt Static Routes The system brings up the Static Routes table form Figure 4 33 Static Routes Form Note Refer to the field definitions in Step 3 for the meaning of each field in the table 2 To edit a static route select a route from the Static Routes form and then select the Edit button OR 3 To add a static route select the Add button from the form Web Manager for Administrators 97 Configuring the ACS in Expert Mode 4 The system invokes the New Modify Route dialog box E New Modify Route Mic
123. rosoft Internet Explorer Aa ie Route Default y Goto Interface x ethD Metric 3 Figure 4 34 5 Complete the fields as follows Table 4 28 New Modify Route Dialog Box Fields Field Name Definition Route Select Default Network or Host Network IP This field appears only if Network is selected The address of the destination network Network Mask Only if Network is selected The mask of the destination network Host IP Only if Host is selected The IP address of the destination host Go to Select Gateway or Interface Adjacent field The address of the gateway or interface Metric The number of hops 6 Select Apply when done 98 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Security The Security configuration of the ACS as shown by the left menu panel includes the following configuration forms Security Active Ports Sessions Security Profile e Users and Groups e Active Ports Sessions e Security Profile Users and Groups Users and Groups configuration allows you to set up users to have access to the ACS web application assign them to specific groups that share common access rights as well as assign or re assign passwords Moreover you can create new groups to add to the group list The access limits provide privileges based on the functionality of the Web page Web Manager for Administrators 99 Configuring the ACS in Expert Mode The two
124. s a Java browser is used to e Connect to the ACS box The connection type is always SSHv2 e Connect to a console port based on which port you select from the drop down menu The connection type depends on how your ACS is configured 1 From the top menu bar select Applications from the left menu panel select Connect The system invokes the port selection form 56 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Applications Power Management Terminal Profile Menu Connect to ACS c quote y Figure 4 14 ACS and Serial Ports Connection Form 2 To connect to a port by default the radio button is selected for connecting to a port select the port from the drop down menu to which you wish to connect and then click on Connect OR To connect to the ACS box select the radio button for Connect to ACS and click on Connect Depending on your selection the system either opens a Java connection to the port selected or launches SSHv2 connection to the ACS box Power Management ACS allows you to remotely manage all Intelligent Power Distribution Units IPDUs connected to the ACS Power management configuration comprises five tabbed forms Table 4 13 Power Management Tabs Form Title Use Outlets Manager Switch on off and lock unlock outlets Web Manager for Administrators 57 Configuring the ACS in Expert Mode Table 4 13 Power Management Tabs
125. s another example a sub network 192 168 16 64 with mask 255 255 255 224 the addresses we may assign to computers on the sub network are 192 168 16 65 to 192 168 16 94 with a broadcast address of 192 168 16 95 A number used by software to separate the local subnet address from the rest of a given Internet protocol address Network masks divide IP addresses into two parts network address and address of a particular host within the network Mask have the same form as IP addresses i e 255 255 255 0 however its value is needed to be understood as a 32 bit number with certain number of ones on the left end and zeros as the rest The mask cannot have an arbitrary value The primary function of a subnet mask is to define the number of IP hosts that participate in an IP subnet Computers in the same IP subnet should not require a router for network communication Network File System is a protocol suite developed and licensed by Sun Microsystems that allows different makes of computers running different operating systems to share files and disk storage NFS is implemented using a connectionless protocol UDP in order to make it stateless 161 162 NTP Object Identifiers OID Off Line Data Buffering OID Network Time Protocol A standard for synchronizing your system clock with the true time defined as the average of many high accuracy clocks around the world The SNMP manager or the management application uses a wel
126. s button located at the bottom of the ACS application window to save your configuration To Delete a User 1 To delete an assigned user select the user you wish to delete from the appropriate Serial Port view table 2 Based on the Serial Port view table that you are working on select the corresponding Delete button 3 Select the apply changes button located at the bottom of the ACS application window Configuration To configure IPDUs to generate alarms or syslog files perform the following steps Web Manager for Administrators 63 Configuring the ACS in Expert Mode 1 From the top menu bar select Applications from the left menu panel select Power Management from the default Outlets Manager form select the Configuration tab The system brings up the Configuration form Configuration Serial Port 2 Configuration Name FT Enable Over Current Protection l Enable Syslog l Enable Buzzer Alarm Threshold Master Unit fa y First Slave El Serial Port 3 Configuration Name l Enable Over Current Protection C Enable Syslog FT Enable Buzzer Alarm Threshold Master Unit j First Slave fa Figure 4 19 Power Management Configuration Form 2 From the Configuration form select the Serial Port you wish to configure and then click on the appropriate radio buttons to enable disable Over Current Protection Syslog and Buzzer 3 Ifenabling the buzzer or alarm notification provide the Alarm Th
127. s remote access authentication and related AlterPath Advanced Console Server July 2005 TACACS TCP Keep Alive Interval Telnet Terminal Server TTY Glossary services such as event logging User passwords are administered in a central database rather than in individual routers providing an easily scalable network security solution Terminal Access Controller Access Control System Plus A protocol that provides remote access authentication authorization and related accounting and logging services used by Cisco Systems The time interval between the periodic polling of all inactive TCP IP connections checking that the client processes really are still there After a certain period of inactivity on an established connection the server s TCP IP software will begin to send test packets to the client which must be acknowledged After a preset number of probe packets has been ignored by the client the server assumes the worst and the connection is closed The keep alive timer provides the capability to know if the client s host has either crashed and is down or crashed and rebooted A terminal emulation program for TCP IP networks such as the Internet The Telnet program runs on your computer and connects your PC to a server on the network You can then enter commands through the Telnet program and they will be executed as if you were entering them directly on the server console A terminal server has one Ethernet L
128. ser List of the Users and Groups form and then select the Delete button at the bottom of the list box OR 2 To delete a group select the group name from the Group listbox of the Users and Groups form and then select the Delete button v To Change the User Password 1 To change a user s password select the user whose password you wish to change from the User List and then select the Change Password button The system brings up the Change Password dialog box Complete the Change Password dialog box and then select OK From the bottom of the main ACS window select apply changes to save your configuration to Flash Web Manager for Administrators 101 Configuring the ACS in Expert Mode Active Ports Sessions The Active Ports Sessions window is designed to provide you a quick status and usage information for example user tty Login time JCPU etc pertaining to all active ports sessions Open sessions are displayed with their identifications and statistical data for login session and CPU usage for the specific client JCPU relates all processes attached to that port including running background processes PCPU relates the current processing time e Select Security gt Active Ports Sessions The system invokes the Active Ports Sessions form Security Users and Groups Uptime 5 01 Security Profile Figure 4 36 Active Port Sessions Form Table 4 29 Active Port Session Fields Field Name Definit
129. ted and 1st fragmented packets 92 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Table 4 25 Edit Rule Dialog Box Fields Field Name Definition ICMP Options Section Select from the scrollable list the error message to be associated with the rule ICMP is the internet protocol sent in response to errors in TCP IP messages i e IP datagrams or packets between a host and a gateway The messages are processed by the IP software and are transparent to the application user Additional Fields If you selected Log as the Target the following additional fields appear LOG Options Section Log Level emerg Z Log Prefix TCP sequence TCP options F IP options Table 4 26 Edit Rule Log Options Field Name Definition Log Level The log level classification to be used based on the type of error message e g alert warning info debug etc Log Prefix The prefix that will identify the log TCP Sequence Check box to include TCP sequence in the log TCP Options Check box to include TCP options in the log IP Options Check box to include IP options in the log If you selected Reject as the target the Reject Options field appears Web Manager for Administrators 93 Configuring the ACS in Expert Mode REJECT Options Section Reject with icmp net unreachable y From the scrollable list select the ICMP message to be associated with the Reject target Click on the OK
130. the ACS configuration window to save your port settings Access Power Management There are three ways in which the General form allows you to access Power Management SSH Telnet SSH and Telnet Go to Ports gt Physical Ports gt General From the Connection Protocol pull down menu of the General tabbed form select Power Management The system invokes new fields for selecting the connection type From the invoked dropdown entry field Allow Access by select the desired connection type AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Virtual Ports Ports Status Console Telnet IPDU Console Telnet Console Telnet Figure 4 42 Serial Ports Access Modification Form 5 6 7 9 The system activates the Access and Other tabs If you selected SSH and or Telnet select the Access tab From the Access tabbed form configure the authentication method for SSH and or Telnet as selected from the previous form If Biometric authentication is required select and complete the Other tabbed form Click on apply changes to save your configuration to Flash Access User and Group Setup The Access form of the Ports menu is used to assign users and groups to an authentication services You also select the authentication service from this form Web Manager for Administrators 111 Configuring the ACS in Expert Mode 112 A summary of authentication services that you
131. ther ACS units slaves The ports on the slave unit acts as an extension of the master unit The Virtual Ports form is used to add edit or delete these virtual ports or slaves 1 From the top menu select Ports from the left menu select Virtual Ports The system brings up the Virtual Ports Slave form Web Manager for Administrators 121 Configuring the ACS in Expert Mode v To Add or Edit a Slave Figure 4 47 Virtual Ports Form 1 To add a new slave select the Add button OR 2 To edit a slave select the slave you wish to edit from the Slave list The system brings up the New Modify Port dialog box 122 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode Number of ports First Local Port Number Local IP First Local TCP Port Number Remote IP First Remote TCP Port Number Protocol Telnet y 3 Complete the dialog box Table 4 37 New Modify Port Dialog Box Fields Field Name Definition Number of Ports Choices are 1 4 8 16 32 and 48 First Local Port No As indicated Local IP Local IP address First Local TCP Port No As indicated Remote IP Remote IP address First Remote TCP Port No As indicated Protocol Communication method between master and slave Telnet or SSH 4 If you want to assign port names to the ports select the Port Names button The system brings up the Port Names dialog box Web Manager for Administrators 123
132. through the ACS box e OUTPUT For locally generated packets Rule Each chain has a sequence of rules that address the following e How the packet should appear in order to match the rule Some information about the packet is checked according to the rule for example the IP header the input and output interfaces the TCP flags and the protocol e What to do when the packet matches the rule The packet can be accepted blocked logged or jumped to a user defined chain When a chain is analyzed the rules of this chain are reviewed one by one until the packet matches one rule If no rule is found the default action for that chain will be taken v To Configure The Firewall e Select Network gt Firewall Configuration The system brings up the Firewall Configuration form As explained in the last section this form lists the chains that make up the rules for IP filtering Web Manager for Administrators 87 Configuring the ACS in Expert Mode 88 Network Host Settings Syslog PCMCIA Management VPN Connections ACCEPT SNMP Daemon Settings Services Host Table Static Routes Figure 4 29 Network Firewall Configuration Form Adding a Chain 1 From the Firewall Configuration form click on the Add button The system brings up the Add Chain dialog box 3 Add Chain Microsoft Internet Explorer m E4 2 Type in the chain name in the Name Field and then select OK Spaces are not allowed in the chain name
133. tion method the following dialog box is used 3 Notifications Entry Microsoft Internet Explorer rim la Alarm Trigger Pager Number m Text SMS User Name A SMS Server IP A SMS Port 0 Figure 4 52 Pager Notification Form Table 4 40 Pager Notification Form Fields Field Name Definition Alarm Trigger The trigger expression used to generate an alarm untitled dropdown field Pager Number The pager number of the notification recipient Text The text message for the pager SMS Server IP The IP address of the SMS server SMS Port The port used by the SMS server Web Manager for Administrators 129 Configuring the ACS in Expert Mode SNMP Trap Notifications SNMP traps are event notifications that are sent to a list of managers configured to receive events for that managed system The Traps provide the value of one or more instances of management information Any SNMP enabled Device generates Fault Reports Traps that are defined in the MIB which the SNMP Agent has implemented The Trap Definition vary with the SNMP Version which defines the messaging format but the information contained in these are essentially identical The major difference between the two message formats is in identifying the events If you selected SNMP Trap as the notification method the following dialog box is used Alarm Trigger OID Type Value o Trap Number Cold Start Commun
134. unnel between two networks ends over a not necessarily secure third network In ACS the IPsec is used to connect the ACS securely to a host or to a whole network configurations usually referred to as host to network and host to host tunnel Practically this is the same thing as a VPN but here one or both sides have a degenerated subnet i e only one machine The IPsec protocol provides encryption and authentication services at the IP level of the network protocol stack Working at this level IPsec can protect any traffic carried over IP unlike other encryption which generally protects only a particular higher level protocol PGP for mail SSH for login SSL for Web work and so on The implementation of IPSec used by the ACS is FreeSWAN www freeswan org You can use IPsec on any machine that does IP networking Wherever required to protect traffic you can install dedicated IPsec gateway machines IPsec can also run on routers firewall machines various application servers and end user desktop or laptop machines Web Manager for Administrators 79 Configuring the ACS in Expert Mode 80 Authentication Keys To establish a connection the Console Server and the other end must be able to authenticate each other For FreeS WAN the default is public key authentication based on the RSA algorithm VPN Connections The VPN configuration form allows you to configure one or more VPN connections to other systems or Cyclades ACS de
135. urther configuration Please choose from the three preset security levels Secured Moderate or Open You can also configure a customized security profile Figure 4 37 Security Profile Form 1 From the main entry panel select a pre defined Security Profile and click on apply changes OR 2 Click on Custom to define services individually The system brings up the following Custom Profile window 104 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode M Telnet C FIP SSH M ssHy1 SSHVv2 Web Access HTTP M HTTPS Access to Serial Ports M allow SSH to Serial Ports M allow Telnet to Serial Ports zj Figure 4 38 Custom Security Profile Dialog Box M SNMP M IPSec M RPC M ICMP SSH Options SSH port 22 F allow root access HTTP amp HTTPS Options HTTP port eo E HTTP redirects to HTTPS HTTPS port 1443 3 Enable or disable services configure ports and configure access to the Serial Ports 4 Click on apply changes Web Manager for Administrators 105 Configuring the ACS in Expert Mode Ports The Ports section of the ACS configuration in Expert Mode provides three menu choices e Physical Ports Allows you to view and modify the physical port settings e Virtual Ports Allows you to view and modify the slave port settings e Ports Status Provides a read only view on status of each physical port its signal status and the current active us
136. used to authenticate messages sent between an SNMP client and a router containing an SNMP server The community name is sent in every packet between the client and the server Terminal used to configure network devices at boot start up time Also used to refer to the keyboard video and mouse user interface to a server Most of the equipment in a data center servers routers switches UPS PBX etc has a serial console port for out of band management purposes AlterPath Advanced Console Server July 2005 DHCP DNS Server Domain Name Escape Sequence Glossary Dynamic Host Configuration Protocol A protocol for automatic TCP IP configuration that provides static and dynamic address allocation and management DHCP enables individual computers on an IP network to extract their configurations from a server the DHCP server or servers in particular servers that have no exact information about the individual computers until they request the information The overall purpose of this is to reduce the work necessary to administer a large IP network The most significant piece of information distributed in this manner is the IP address Domain Name Server The computer you use to access the DNS to allow you to contact other computers on the Internet The server keeps a database of host computers and their IP addresses The unique name that identifies an Internet site Domain Names always have 2 or more parts separate
137. ver con alimentaci n de corriente directa CD solo debe ser instalado en reas con restricci n y de AlterPath Advanced Console Server July 2005 acuerdo a los art culos 110 18 110 26 y 110 27 del National Electrical Code ANSI NFPA 701 Edici n 1999 Para conectar la corriente directa CD al sistema utilice cable de 0 75 mm 18 AWG Instalar el interruptor corriente directa CD aprobado por UL entre la fuente de alimentaci n y el AlterPath Advanced Console Server El limite m nimo del interruptor deber ser 2 amperes con conductor de 0 75 mm 18 AWG Trabajar dentro del AlterPath Advanced Console Server No intente dar servicio al AlterPath Advanced Console Server solo que este bajo la direcci n de Soporte T cnico de Cyclades Si este es el caso tome las siguientes precauciones Apague el AlterPath Advanced Console Server Asegurase que este tocando tierra antes de tocar cualquier otra cosa que puede ser al tocar la parte trasera del equipo Bater a precauci n Una bater a nueva puede explotar si no esta instalada correctamente Remplace la bater a cuando sea necesario solo con el mismo tipo recomendado por el fabricante de la bater a Deshacerse de la bater a de acuerdo a las instrucciones del fabricante de la bater a Safety Guidelines 149 150 AlterPath Advanced Console Server July 2005 Appendix C Supported Browsers and JRE The following are the list of topics that are covered in this
138. vices Select one of the existing VPN connections and click the edit button or click the add button to add a new one This launches a dialog box to prompt for the details of the connection Complete the fields in the dialog box The RSA keys may be entered using the Copy and Paste feature of your Browser v To Configure VPN Connections 1 Select Network gt VPN Connections The system brings up the VPN Connections form Syslog PCMCIA Management SNMP Daemon Settings Servic Figure 4 26 VPN Connections Form 2 To edit a VPN connection select the VPN connection that you wish to edit from the form and then select the Edit button OR AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode To add a VPN connection select the Add button The system brings up the New Modify VPN Connection dialog box F New Modify Connection Microsoft Internet Explorer iol xi Connection Name Authentication Authentication cli ase Authent Ron Public xy Remote Right ID IP Address NextHop Subnet RSA Key El dl Local Left R i WaAddress SS NextHop ay Subnet Ho RSA Key O g E Boot Action Ignore Y ll If the selected Authentication Method is RSA Public Keys the left dialog box is used If the Authentication Method is Shared Secret the right dialog box is used 3 Edit or complete the appropriate fields from either dialog box as follows Table 4 22 Add Modify VPN Conne
139. xcept for the adjacent item just defined 1 From the Firewall Configuration form select the chain containing the rule s that you wish to edit and then click on the Edit Rule button The system brings up the Edit Rules for Chain form Web Manager for Administrators 89 Configuring the ACS in Expert Mode Edit Rules for Chain INPUT anywhere anywhere DROP anywhere anywhere Figure 4 30 Edit Rule Form 2 From the Edit Rules for Chain form select the rule you wish to edit and then click on the Edit button Use the Up and Down buttons to navigate through the list as necessary 3 The system brings up the Edit Rule dialog box 90 AlterPath Advanced Console Server July 2005 Configuring the ACS in Expert Mode A Edit Rule Microsoft Internet Explorer E Ee ie Target accer y Source IP 0 0 0 0 Mask o Inverted Destination IP 0 0 0 0 Mask fo I Inverted Protocol rme z T Inverted Input Interface Inverted Output Interface Inverted Fragments All packets ICMP Options Section ICMP Type timestamp request Inverted a 4 Complete the necessary fields as follows Table 4 25 Edit Rule Dialog Box Fields Field Name Definition Target Indicates the action to be performed to the IP packet when it matches the rule The kernel can be configured to ACCEPT DROP RETURN LOG or REJECT the packet by sending a message translating the source or the destination IP address port or sending the pa
140. zard mode the system assumes that all devices will be connected with the same parameter values If you need to assign different parameters for each device then you must click on the Expert mode button and select Ports gt Physical Ports to enter these values By default all Serial Ports are disabled The administrator can select and assign specific users to individual ports through the Expert mode v To Set Parameters for All Serial Ports 1 Select Step 3 Port Profile The system displays the Port Profile form Step 1 Security Profile SS NS Set up the CAS Console Access Server profile for the serial ports Specify the serial parameters for all ports Step 4 Access See Help for more details Step 5 Data Buffering The previous port specific parameters will be discarded Step 6 System Log Connection console SSH Ea ES 3600 Protocol Flow Control None Data Size Parity None Stop Bits Authentication Required 7 lez fez Figure 4 8 Serial Ports Parameters Setup for All Serial Ports 2 From the Port Profile form complete the necessary fields 44 AlterPath Advanced Console Server July 2005 Configuring the ACS in Wizard Mode Table 4 5 Serial Ports Parameters Field Name Definition Connection Protocol The method you will use to access the serial ports Cyclades recommend SSH to ensure that all data and authentication information are encrypted Other options are Telnet and Raw Data for u