Home
Ex d Gas installation
Contents
1. warning signals 1 Introduction The BExTS110D is a flameproof Sontel telephone sounder which is certified to the meet the requirements of the ATEX directive 94 9 EC and IECEx scheme The Sontel produces a loud audible signal when triggered by a telephone ringing signal and can be used in hazardous areas where potentially flammable atmospheres may be present Thirty two different sounds can be selected by internal switches see tone table on Page 4 The BExTS110D unit produces output levels in the 110dB A range The unit can be used in Zone 1 and Zone 2 areas with gases in groups IIA IIB and IIC and temperature Classifications of T1 T2 T3 and T4 For ambient temperatures over 55 C the gas groups are limited to IIA and IIB 2 Marking All units have a rating label which carries the following important information Unit Type No BExTS110D Input Voltage 230V or 110V or 115V Codes Ex d IIC T4 for Ta 50 C to 55 C Ex d IIB T4 for Ta 50 C to 70 C Certificate Nos KEMA 99ATEX6312 IECEx KEM 10 0003 Il 2G C s 0518 DO NOT OPEN WHEN AN EXPLOSIVE GAS ATMOSPHERE IS PRESENT CE Marking Notified Body No Warnings COVER BOLTS CLASS A4 80 USE HEAT RESISTING CABLES AND CABLE GLANDS Rated 110 C AT AMB TEMPERATURES OVER 40 C Year of Construction Serial No i e 10 1TS23000001 3 Type Approval Standards The Sontel has EC Type Examination and IECEx certificates issued by KEMA and have been appro
2. Section 7 of this manual 2 S S Mounting 7 Safety Warning Electrostatic Hazard The acoustic horn section is made of ABS Plastic therefore to avoid a possible ELECTROSTACTIC CHARGE the unit must only be cleaned with a damp cloth 8 Access to the Flameproof Enclosure In order to connect the electrical supply cable and the telephone line cable to the Sontel it is necessary to remove the flameproof cover to gain access to the flameproof chamber To achieve this remove the four M6 hexagon socket head screws see figure 2 and withdraw the flameproof cover taking extreme care not to damage the flameproof joints in the process Note the four M6 screws are Class A4 80 stainless steel and only screws of this category can be used on these Sontels It is therefore important that these screws and their spring washers are kept in a safe place during installation 4 off M6 Cover Screws External Earth Terminal On completion of the cable wiring installation the flameproof joints should be inspected to ensure that they are clean and that they have not been damaged during installation Also check that the earth bonding wire between the two casting sections is secure and the O ring seal is in place When replacing the flameproof cover casting ensure that it is square with the flameproof chamber casting before inserting Carefully push the cover in place al
3. B Ethylene Group IIC Up to 55 C only Hydrogen and Acetylene Equipment Category 2G Temperature Classification T1 400 C T2 300 C T3 200 C T4 135 C Ambient Temperature Range 50 C to 55 C Gas Groups IIA IIB and IIC 50 C to 70 C Gas Groups IIA and IIB European Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH Document No IS 2427 P Issue F 12 03 10 sales e 2 s com Www e 2 s com Tel 44 0 208 743 8880 Fax 44 0 208 740 4200 Sheet 1 of 4 6 Sontel Location and Mounting The location of the Sontels should be made with due regard to the area over which the warning signal must be audible And they should only be fixed to services that can carry the weight of the unit The Sontels should be securely bolted to a suitable surface using the 7mm diameter boltholes in the stainless steel U shaped mounting bracket see figure 1 The angle can then be adjusted in the direction that the sound is primarily required to cover This can be achieved by loosening the two large bracket screws in the side of the unit which allow adjustment in steps of 18 On completion of the installation the two large bracket adjustment screws on the side of the unit must be fully tightened to ensure that the unit cannot move in service Flameproof Flameproof Chamber Cover iwi Plastic Acoustic Horn Please see Safety Warning in
4. Facsimile 44 0 20 8740 4200 Company Registration No 2763350 E mail sales e2s com Registered Office Impress House www e2s com Mansell Road London UK W3 7QH UK
5. Www e 2 s com Tel 44 0 20 8743 8880 Fax 44 0 20 8740 4200 EC DECLARATION OF CONFORMITY amp Manufacturer European Safety Systems Ltd Impress House Mansell Road Acton E p London W3 7QH UK warning signals Equipment Type BExS110D BExS120D BExS110E BExS120E BExDS120D BExDS110D BExDS120E BExDS110E BExL25D BExL15D BExL25E BExL15E BExDL25D BExDL15D BExDL25E BExDL15E BExA110D BExA120D BExA110E BExA120E BExDA110D BExDA120D BExDA110E BExDA120E BExTS110D BExDTS110D BExH120D BExDH120D BExL25GD BExDL25GD Directive 94 9 EC Electrical and Mechanical equipment for use in explosive atmospheres ATEX Notified Body for EC type Examination KEMA Quality B V Notified Body No 0344 Utrechtseweg 310 6812 AR Arnhem The Netherlands EC type Examination Certificate KEMA 99ATEX6312 Notified Body for Quality Assurance Notification Sira Certification Service Notified Body No 0518 Rake Lane Eccleston Chester CH4 9JN UK Quality Assurance Notification SIRA 05 ATEX M342 Provisions fulfilled by the equipment I2 G Ex d IIB or IIC T4 or 2 G Ex de IIB or IIC T4 2 D Ex tD A21 IP66 or IP67 T100 C or T115 C Standards applied EN 60079 0 2006 EN 60079 1 2007 EN 60079 7 2003 EN 61241 0 2006 EN 61241 1 2004 Directive 89 106 EEC Construction Products Directive CPD BExS110D24DC BExS120D24DC tones 2 3 9 15 16 17 only Notified Body for EC type Examination VdS Schadensverh tung Gm
6. ations can be used which must be suitable for the type of cable being used and also meet the requirements of the Ex d flameproof installation standard EN60079 14 2008 IEC60079 14 2007 SAFETY WARNING If the BExTS110D Sontels are used at high ambient temperatures i e over 40 C then the cable entry temperature may exceed 70 C and therefore suitable heat resisting cable glands must be used with a rated service temperature of at least 110 C If a high IP Ingress Protection rating is required then a suitable sealing washer must be fitted under the cable gland When only one cable entry is used the other one must be closed with an Ex d flameproof blanking plug which must be suitably approved for the installation requirements 13 Cable Connections The cable connections are made into the terminal blocks on the Sontel pcb assembly located in the flameproof enclosure See section 8 of this manual for access to the flameproof enclosure The printed circuit board has two terminal blocks one for the mains supply input voltage and one for the telephone signal input cable see figure 4 The mains input cable should enter the enclosure via one of the M20 cable entries and be connected to the supply terminals L and N and the telephone signal cable should enter the enclosure via the other M20 entry and be connected to the telephone terminal A single wire with a cross sectional area of up to 4mm can be connected to each t
7. bH Notified Body No 0786 Amsterdamer Str 172 174 50735 K ln Germany EC type Examination Certificate 0708 CPD 20225 Standards applied EN 54 3 2001 A1 2002 Directive 2009 26 EC Marine Equipment Directive MED BExS110D24DC M onl Notified Body for EC type Examination Germanischer Lloyd SE Notified Body No 0098 Brooktorkai 18 20457 Hamburg Germany EC type Examination Certificate 19 702 11 HH Standards applied EN 54 3 2001 A1 2002 A2 2006 IEC 60092 504 2001 IEC 60533 1999 Directive 2004 108 EC Electromagnetic Compatibility Directive EMC Standards applied EN 61000 6 1 2007 EN 61000 6 2 2005 EN 61000 6 3 2007 EN 61000 6 4 2007 The standards EN 60079 0 2006 EN 60079 7 2003 EN 61241 0 2006 and EN 61241 1 2004 are no longer harmonized The requirements of these standards have been checked against the harmonized standards EN 60079 0 2009 EN 60079 7 2007 and EN 60079 31 2009 and there were no major technical changes affecting the latest technical knowledge for the products listed above On behalf of European Safety Systems Ltd declare that on the date the equipment accompanied by this declaration is placed on the market the equipment conforms with all technical and regulatory requirements of the above listed directives Martin Streetz Date and Place of Issue London 04 07 2012 Quality Assurance Manager Document No DC 001 Issue_C Telephone 44 0 20 8743 8880 European Safety Systems Ltd
8. ed 70 C and therefore suitable heat resisting cables must be used with a rated service temperature of at least 110 C European Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH Document No IS 2427 P Issue F 12 03 10 sales e 2 s com Www e 2 s com Tel 44 0 20 8743 8880 Fax 44 0 20 8740 4200 Sheet 2 of 4 11 Earthing The Sontel units must be connected to a good quality earth The units are provided with internal and external earthing terminals which are both located on the terminal chamber section of the unit see figures 2 and 3 When using the internal earth terminal ensure that the stainless steel M4 flat washer is between the incoming earth wire and the enclosure Internal Bonding Wire Terminal 2 off M20 Cable Entries Internal Earth Terminal Figure 3 When using the extemal earth terminal a cable crimp lug must be used The cable lug should be located between the two M5 stainless steel flat washers The M5 stainless steel spring washer must be fixed between the outer flat washer and the M5 stainless steel nut to ensure that the cable lug is secured against loosening and twisting The internal earth bonding wire ensures that a good quality earth is maintained between the flameproof chamber casting and the flameproof cover casting 12 Cable Glands The BExTS110D Sontels have dual cable gland entries which have an M20 x1 5 Only cable glands approved for Ex d applic
9. erminal way When connecting wires to the terminals great care should be taken to dress the wire so that when the cover is inserted into the chamber the wires do not exert excess pressure on the terminal blocks This is particularly important when using cables with large cross sectional areas such as 2 5mm and above BExTS110D Sontel Pulse Tone Header Pin Volume Control DIP Switch Mains Supply Input Terminals LandN Telephone Signal Input Terminals 14 Tone Selection The BExTS110D Sontels have 32 different tones that can be selected by the DIP switches on the sounder pcb see figure 4 The tone table on page four shows the switch positions for the 32 tones European Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH Document No IS 2427 P Issue F 12 03 10 sales e 2 s com Www e 2 s com Tel 44 0 20 8743 8880 Fax 44 0 20 8740 4200 Sheet 3 of 4 15 Volume Control The BExTS110D Sontel has a volume control to adjust the output level To set the required output level adjust the potentiometer on the sounder pcb see figure 4 For maximum output level the potentiometer should be set to the fully clockwise position TONE SELECTION TABLE DIP Switch Tone Selection Settings Stage 1 Frequency Description 12345 1 Continuous 1000Hz 00000 Toxic gasalarm 2 Altemat
10. ing 800 1000Hz at 0 25s 1 000 0 intervals 3 Slow Whoop 500 1200Hz at 03Hz 0 100 0 with 0 5s gap repeated 4 Sweeping 800 1000 at 1Hz 11000 5 Continuous at 2400Hz 00100 6 Sweeping 2400 290Hz at 7Hz 10100 7 Sweeping 2400 2900Hz at 1Hz 01100 8 Siren 500 1200 500Hz at 0 3Hz 11100 9 Sawtooth 1200 500Hz at 1Hz 00010 10 Altemating 2400 2900Hzat 2Hz 10010 11 Intermittent 1000Hz at 0 5Hz 01010 General alarm 12 Altemating 800 1000Hz at 0 875Hz EEO 10 13 Intermittent 2400Hz at 1Hz 00110 14 Intermittent 800Hz 0 25s on Is off 1 0110 15 Continuous at 800Hz EITO 16 Intermittent 660Hz 150mS on a e O 10 150mS off 17 Altemating 544Hz 0000 100mS 440H z 400 mS 18 Intermittent 660Hz 1 8s on 1 85 off 1000 19 1400Hz to 1600Hz sweep up over 0 1 0 0 Is 1600Hz to 1400Hz sweep down over 0 5s 20 Continuous 660Hz 1100 21 Altemating 554 440Hz at 1Hz 0010 22 Intermittent 554Hz at 0 875Hz 1010 23 800Hz puking at 2Hz 0110 24 Sweeping 800 1000Hz at 50Hz Lod 140 25 Sweeping 2400 2900Hz at 50Hz 0001 26 Simulated bell sound 1001 27 Continuous 554Hz 0101 28 Continuous 440Hz 1101 29 Sweep ing 800 1000Hz at 7Hz 0011 30 420Hz repeating 0 625s on 0 625s PEVA off Australian alert signal 31 1200 500Hz at 1 Hz Olli Prepare to abandon platform 32 Sweeping 500 1200Hz 3 75s on EFLA 0 25s off 15Hz European Safety Systems Ltd Impress House Mansell Road Acton London W3 7QH Document No IS 2427 P_ Issue F 12 03 10 Sheet 4 of 4 sales e 2 s com
11. lowing time for the air to be expelled Only after the cover is fully in place should the four M6 Stainless Steel A4 80 cover bolts and their spring washer be inserted and tightened down If the cover jams while it is being inserted carefully remove it and try again Never use the cover bolts to force the cover into position 9 Power Supply Selection It is important that a suitable power supply is used to run the Sontels The following table shows the input current taken by the various units Unit Type Input Input Max Voltage Current I P Volts BExTS110D 230V AC 56mA 264V BExTS110D 110V AC 93mA 121V BExTS110D 115V AC 110mA 126V The input current will vary according to the voltage input level and the frequency of the tone selected The current levels shown above are for the 440Hz Continuous tone nominal input voltage The units have a switching voltage regulator circuit and therefore the input current level will decrease slightly as the input voltage in increased and will increase slightly as the input voltage is reduced The above table also shows the maximum voltages at which the sounders can be operated 10 Cable Selection When selecting the cable size consideration must be given to the input current that each unit draws see table above and the length of the cable runs SAFETY WARNING If the high output BExTS110D units are used at high ambient temperatures i e over 40 C then the cable entry temperature may exce
12. ved to the following standards EN60079 0 2006 IEC60079 0 2004 Ed4 General Requirements EN60079 1 2007 IEC60079 1 2007 Ed6 Flameproof Enclosure d INSTRUCTION MANUAL ATEX IECEx BExTS110D_ Fiameproof Sontel 4 Installation Requirements The Sontels must be installed in accordance with the latest issues of the relevant parts of the EN60079 standards or the equivalent IEC standards Selection Installation and maintenance of electrical apparatus for use in potentially explosive atmospheres other than mining applications or explosive processing and manufacture EN60079 14 2008 Electrical Installations in Hazardous Areas other than mines EN60079 10 2003 Classification of Hazardous Areas The installation of the units must also be in accordance with any local codes that may apply and should only be carried out by a competent electrical engineer who has the necessary training 5 Zones Gas Group Category and Temperature Classification The BExTS110D Sontels have been certified Ex d IIC T4 for Ta 50 C to 55 C and Ex d IIB T4 for Ta 50 C to 70 C This means that the units can be installed in locations with the following conditions Area Classification Zone 1 Explosive gas air mixture likely to occur in normal operation Zone2 Explosive gas air mixture not likely to occur and if it does it will only exist for a short time Gas Groupings Group IIA Propane Group II