Home

CHG 518 - Williams Sound

image

Contents

1. 44 800 328 6190 952 943 2252 FAX 952 943 2174 www williamssound com 2015 Williams Sound LLC MAN 150C
2. PRESENTATION OR WARRANTY WITH RESPECT TO THE CHG 518 MULTIPLE BATTERY CHARGER UNAUTHORIZED REPAIRS OR MODIFICATIONS WILL VOID THE WARRANTY The exclusions and limitations set out above are not intended to and should not be construed so as to contravene mandatory provisions of applicable law If any part or term of this Disclaimer of Warranty is held to be illegal unenforceable or in conflict with applicable law by a court of competent jurisdiction the validity of the remaining portions of this Disclaimer of Warranty shall not be affected and all rights and obligations shall be construed and enforced as if this Limited Warranty did not contain the particular part or term held to be invalid Your warranty becomes effective the date you purchase your system Your returned warranty card is our way of knowing when your warranty begins Please take a moment to fill it out and mail the enclosed card You may also register your product online http www willamssound com Warranty registration This information will help us serve you better in the future Thank you If you experience difficulty with your system call Toll Free for Customer Assistance 1 800 843 3544 U S A or 1 952 943 2252 Outside the U S A If it is necessary to return the system for service your Customer Service Representative will give you a Return Authorization Number RA and shipping instructions YP WILLIAMS SOUND 10300 Valley View Rd e Eden Prairie MN 553
3. YP WILLIAMS SOUND CHG 518 5 Unit Drop In Battery Charger USER MANUAL For use with Williams Sound WIR RX 18 and PLR SR1 Receivers MAN 150C CHG 518 5 Unit Drop in Charger Recycling Instructions ON Help Williams Sound protect the environment Please take the time to dispose of vA 9 your equipment properly Product Recycling Please do NOT dispose of your Williams Sound equipment in the X household trash Please take the equipment to an electronics recycling center OR return the product to the factory for proper disposal Setup Instructions 1 Plug the DC power connector into the rear of the CHG 518 Figure 1 2 Plug the TFP 043 power supply into an AC wall outlet Figure 1 Figure 1 CHG 518 Rear View CHG 518 DC Power Connection TFP 043 A pOT Connection Power Supply 3 Insert the Receiver into the charging slot The receivers must be facing forward to make contact with the charging contacts Figure 2 The LED Indicator will illuminate red when charging and will change to green when charging is complete Figure 2 CHG 518 Top View Receiver place into slot facing forward Charging slot Charging LED Indicator s 1 per slot CHG 518 CHG 518 5 Unit Drop in Charger 4 It is safe to leave the receivers in the charger even after the batteries are fully charged However we do not recommend leaving receivers in the charger for a prolonged period of time 5 A piggy ba
4. ck cable is provided which can be used to connect up to three CHG 518 chargers to one TFP 043 power supply e Up to 5 receivers can be charged simultaneously per CHG 518 charger e The charging cycle is approximately 6 hours e Anew charging cycle will begin each time a unit is placed into a slot or when the charger is powered up e Each each slot in the charger has its own independent charging circuit so the indicator lights may be different depending on the charging status of each RX 18 receiver CHG 518 Specifications Dimensions 1 5 H x 6 25 W x 12 D 88mm x 158mm x 305mm Weight 1 04 lbs 0 47 kg excluding power supply Color Black Metal and Plastic with white legends Power Supply Input 120 VAC Power Supply 100 240 VAC 12 VDC Model TFP 043 Unit Capacity 5 units per charger 15 units total with three CHG 518 ganged together Inputs One 3 5mm stereo jack and two 1 pair RCA jacks Indicators Individual charging indicators one LED per bay Warranty 1 year 90 day warranty on cables and power supply Approvals CE CJ ROHS WEEE Note Charging specifications are based on Williams Sound rechargeable NiMH battery APO11 Troubleshooting No LED s Light Up 1 Verify that the power supply is plugged into a wall outlet 2 Verify the wall outlet has power no tripped circuit breaker etc 3 Verify the BAT APO11 is installed correctly in the Receiver s 4 Verify that all recei
5. vers are facing front in the charger If charging the indicator LED will illuminate red if fully charged it should illuminate green Limited Warranty Williams Sound products are engineered designed and manufactured under carefully controlled conditions to provide you with many years of reliable service Williams Sound warrants the CHG 518 Multiple Battery Charger against defects in materials and workmanship for ONE 1 year During the first year from the purchase date we will promptly repair or replace the CHG 518 Charger Microphones earphones headphones rechargeable batteries cables carry cases and most other accessory products carry a 90 day warranty WILLIAMS SOUND HAS NO CONTROL OVER THE CONDITIONS UNDER WHICH THIS PRODUCT IS USED WILLIAMS SOUND THEREFORE DISCLAIMS ALL WARRANTIES NOT SET FORTH ABOVE BOTH EXPRESS AND IMPLIED WITH RESPECT TO THE CHG 518 MULTIPLE BATTERY CHARGER INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE WILLIAMS SOUND SHALL NOT BE LIABLE TO ANY PERSON OR ENTITY FOR ANY MEDICAL EXPENSES OR ANY DIRECT INCIDENTAL OR CONSEQUENTIAL DAMAGES CAUSED BY ANY USE DEFECT FAILURE OR MALFUNCTION OF THE PRODUCT WHETHER A CLAIM FOR SUCH DAMAGES IS BASED UPON WARRANTY CONTRACT TORT OR OTHERWISE THE SOLE REMEDY FOR ANY DEFECT FAILURE OR MALFUNCTION OF THE PRODUCT IS REPLACEMENT OF THE PRODUCT NO PERSON HAS ANY AUTHORITY TO BIND WILLIAMS SOUND TO ANY RE

Download Pdf Manuals

image

Related Search

Related Contents

R&S ZVH Analyseur de câble et d`antenne  SAISON 2014/2015  EA993CK-1.5、-2(ハイリフトサービスジャッキ)取扱説明書  E2F  2005v1 Manual False Start Spanish  Télécharger  the instruction manual  MELSEC iQ-R Positioning Module User`s Manual (Startup)  AutoTrac™ RowSense™ - stellarsupport global  User`s manual - Schneider Electric  

Copyright © All rights reserved.
Failed to retrieve file