Home

user manual

image

Contents

1. FIGURE 3 FIGURE 2 Special Note Line termination e When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems O and interferance it is always advisable to connect a 3 o DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and pin 3 DMX of the last fixture Using a cable terminator part number CABL90 will decrease the possibilities of erratic behaviour 5 Pin XLR DMX Connectors e Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion 3 Pin XLR to 5 PIN XLR Conversion Conductor 3 Pin XLR out 5 Pin XLR in Ground shield Pin 1 Pin 1 Negative Pin 2 Pin 2 Positive Pin 3 Pin 3 www prolight co uk
2. operation modes using the UP and DOWN buttons 1 Soun Sound Active mode 2 Slav Slave mode 3 Auto Auto Run mode Once you have selected your desired operation mode press the SET UP button to confirm the setting Sound Active Mode To activate the Sound Active mode first please make sure that you selected Soun in the LED Display window from the above Auto Run Function Mode Now press the SET UP button and select one of the 15 different flower effects using the UP and DOWN buttons P 00 Runs all 15 flower effects one after another P 01 gt gt P 15 Runs selected individual flower effects Once you have set your desired flower effect press the SET UP button to confirm the setting To adjust the sound sensitivity in Sound Active mode press the MODE button to show Sens in the LED display window then press the SET UP button and adjust the sensitivity using the UP and DOWN buttons Once you have selected your desired sensitivity level press the SET UP button to confirm your setting S 00 Low S 15 High Equinox Fever Functions Other functions Slave Mode To set the unit in the Slave mode press the MODE button to show Func in the LED display window Now press the SET UP button and use the UP and DOWN buttons to show Slav in the LED display window and press t
3. EQUIN X FEVER order code EQLED42 user manual www prolight co uk Equinox Fever WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP CAUTION Keep this equipment away from rain moisture and liquids SAFETY INSTRUCTIONS Every person involved with the installation operation amp maintenance of this equipment should Be competent Follow the instructions of this manual CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Before your initial start up please make sure that there is no damage caused during transportation Should there be any consult your dealer and do not use the equipment To maintain the equipment in good working condition and to ensure safe operation it is necessary for the user to follow the safety instructions and warning notes written in this manual Please note that damages caused by user modifications to this equipment are not subject to warranty Equinox Fever Safety IMPORTANT The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorised modification to the equipment e Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipment e Do not open the equipment and do no
4. a universal protocol used as a form of communication between intelligent fixtures and controllers A DMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures most controllers only have a data out terminal DATA Cable DMX cable requirements for DMX operation e The Equinox Fever can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split Equinox Fever DMX Set up Notice e Be sure to follow figures 2 4 3 when making your own cables Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and erratic behaviour common DMX 512 out ES Wio n i DMX 512 in 3 pin XLR Se 3 pin XLR DMX po tds XLR MALE SOCKET XLR FEMALE SOCKET XLR Pin Configuration 2 cold 1 ground 1 ground Pin 1 Ground 2 cold Pin 2 Negative 3Hot 3 Hot Pin 3 Postive
5. hase OPERATING DETERMINATIONS If this equipment is operated in any other way than those described in this manual the product may suffer damage and the warranty becomes void Incorrect operation may lead to danger e g short circuit burns electric shocks lamp failure etc Do not endanger your own safety and the safety of others Incorrect installation or use can cause serious damage to people and property Equinox Fever Technical specifications You should find inside the Equinox carton the following items 1 Equinox Fever 2 Power cable 3 Instruction manual Technical Specifications DMX channels 4 Voltage AC 110 240V 50Hz 60Hz 224 Ultra bright LED s R 48 G 48 B 48 W 48 Y 32 Fuse 1 Amp Power Consumption 25W Dimensions 330 x 230 x 230mm Weight 2 5Kg Operations There are 3 operating modes to choose from 1 DMX Mode 2 Auto Run 3 Sound Active mode DMX Mode When the unit is connected with a universal DMX controller press the MODE button to show Addr in the LED display window you can now set the DMX address from 001 512 using the UP and DOWN buttons once you have set your desired DMX address press the SET UP button to confirm the setting Auto Run Function Mode When the unit is not being used via a DMX controller press the MODE button to show Func in the LED display window Now press the SET UP button and select one of the three following
6. he SET UP buton to confirm the setting The unit will now run in conjunction with the Master unit when linked together with multiple units LED Display On Off Press the MODE button to show LED in the LED display window and press the SET UP button to choose one of the two following options using the UP and DOWN buttons 1 ON The LED display will stay ON all of the time 2 OFF The LED dispaly will turn OFF after the setting has been confirmed Once you have selected your desired option press the SET UP button to confirm your setting Blackout Mode Press the MODE button to show Blind in the LED display window and press the SET UP button to choose one of the two following options using the UP and DOWN buttons 1 NO Auto run mode when the unit is not in Sound Active 2 YES Blackout mode when the unit is not in Sound Active Once you have selected your desired option press the SET UP button to confirm your setting DMX Function Chart Channel 1 Channel 2 Channel 3 Channel 4 i Static colour mode 000 009 010 255 Strobe Speed Master Dimmer Use CH2 to select any of the 24 static patterns colours Sound Active Mode Use CH2 to select any of the 010 255 000 255 Strobe Speed Master Dimmer 30 built in dynamic patterns triggered via the internal microphone Equinox Fever DMX Set up DMX 512 e DMX Digital Multiplex is
7. t modify the equipment e Do not connect this equipment to a dimmer pack e Do not switch the equipment on and off in short intervals as this will reduce the system s life e Only use the equipment indoors e Do not expose to flammable sources liquids or gases e Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable e Make sure that the available voltage is between 220v 240v e Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically e f the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again e If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediately The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature e If your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service e Only use fuses of same type and rating e Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS e WARRANTY One year from date of purc

Download Pdf Manuals

image

Related Search

Related Contents

Seabreeze WA24ZM Specifications  Katun 43143  Suite Notaro Sistema Informativo Studi Notarili  Istruzioni per l`uso - Documentazione tecnica  Manual  Emerson SPS 4001B Recording Equipment User Manual  ASUS T7295 User's Manual  GM 3000AC - Wagner SprayTech USA  Avaya Bay Command Console BCC User's Manual  eppendorf - UCSD Department of Physics  

Copyright © All rights reserved.
DMCA: DMCA_mwitty#outlook.com.