1. POWER SOURCE Universal 100 240V AC 50 60Hz 5A AC power limits USA 100 240V AC 50 60Hz 5A UK 100 240V AC 50 60Hz 5A Germany and EU 100 240V AC 50 60Hz 5A Belgium and France 100 240V AC 50 60Hz 5A South Africa 100 240V AC 50 60Hz 5A Australia 100 240V AC 50 60Hz 5A FUSE RATING T 6 3A 250V OPERATING TEMPERATURE 5 to 45 Deg Centigrade RANGE OPERATING HUMIDITY RANGE 10 to 90 RHL non condensing STORAGE TEMPERATURE 20 to 70Deg C RANGE STORAGE HUMIDITY RANGE 5 to 95 RHL non condensing DIMENSIONS 20 5cm x 17cm x 13 2cm 8 07 x 6 69 x 5 20 W D H WEIGHT TBUS 1A 1 5kg 3 3lbs approx Table clamps 0 26kg 0 57Ibs Metal template 0 125kg 0 28lbs ACCESSORIES Power cord six self locking ties metal template OPTIONS Passive wall plates and interfaces 1 Specifications are subject to change without notice 2 The Universal socket is fully compatible with power plugs in UK India Italy Denmark and the 2 prong Europlug 3 The Universal socket is partially compatible polarity is reversed with plugs in China Switzerland Israel and USA The Universal socket does not supply grounding to plugs in Central Europe and France Order country specific sockets instead 4 The Universal socket does not fit South African plugs 10 KRAMER SIMPLE CREATIVE TECHNOLOGY LIMITED WARRANTY Kramer Electronics hereafter Kramer warrants this product free from
2. see section 5 1 Cut out an opening in your table according to the cutout template Step 2 Connect the Step 3 Adjust the height modular wall plate items of the Connecting see section 5 2 Surface see section 5 3 Configure as required Step 4 Insert the unit Step 5 Secure the unit to see section 5 4 the table see section 5 4 2 KRAMER SIMPLE CREATIVE TECHNOLOGY Overview 3 Overview The TBUS 1A is a furniture mounted connection bus that is easily installed into a table or podium top The TBUS 1A lets you connect any equipment to the room s presentation system installations via cable access or passive interfaces see Figure 1 When the cables are not in use they can be stored inside the unit covered by the lid and out of sight In addition the TBUS 1A features e Modular design letting you tailor it according to your needs e One power socket available in 7 versions USA UK Germany EU Belgium France South Africa Australia and Universal for general use e A black textured lid with a special opening for cable pass through To achieve the best performance e Connect only good quality connection cables thus avoiding interference deterioration in signal quality due to poor matching and elevated noise levels often associated with low quality cables e Avoid interference from neighboring electrical appliances that may adversely influence signal quality and position your Kramer TBUS 1A
3. defects in material and workmanship under the following terms HOW LONGIS THE WARRANTY Labor and parts are warranted for seven years from the date of the first customer purchase WHOIS PROTECTED Only the first purchase customer may enforce this warranty WHAT IS COVERED AND WHAT IS NOT COVERED Except as below this warranty covers all defects in material or workmanship in this product The following are not covered by the warranty 1 Any product which is not distributed by Kramer or which is not purchased from an authorized Kramer dealer If you are uncertain as to whether a dealer is authorized please contact Kramer at one of the agents listed in the Web site www kramerelectronics com 2 Any product on which the serial number has been defaced modified or removed or on which the WARRANTY VOID IF TAMPERED sticker has been torn reattached removed or otherwise interfered with 3 Damage deterioration or malfunction resulting from i Accident misuse abuse neglect fire water lightning or other acts of nature ii Product modification or failure to follow instructions supplied with the product iii Repair or attempted repair by anyone not authorized by Kramer iv Any shipment of the product claims must be presented to the carrier v Removalor installation of the product vi Any other cause which does not relate to a product defect vii Cartons equipment enclosures cables or accessories used in conjunction with the product WHAT WE WILL
4. distributors visit our Web site www kramerelectronics com where updates to this user manual may be found We welcome your questions comments and feedback Safety Warning Disconnect the unit from the power supply before opening servicing Caution CE Kramer Electronics Ltd Web site www kramerelectronics com E mail info kramerel com P N 2900 000696 REV 3
5. 5 4 Connect the cables see section 5 5 5 1 Cutting an Opening in the Table To cut an opening in the table 1 4 Place the included cut out template on the surface of the table where you want to install TBUS 1A Attach the template to the table with the included screws if using the optional metal template Following the inside edge of the template cut a hole in the table surface with a sabre or keyhole saw according to the dimensions shown in Figure 4 not to scale Note The thickness of the table should be 3 inches or less 191 2mm Figure 4 Cutout Dimensions Remove the template from the surface of the table and clean the table surface Take care not to damage the table If needed you can download a full scale template from our Web site 1 At http www kramerelectronics com KRAMER SIMPLE CREATIVE TECHNOLOGY Installing the TBUS 1A Table Connection Bus Kramer Electronics is not responsible for any damage caused to the table 5 2 Installing the Required Wall Plates By default the mounting surface includes a universal power supply two cable pass through plates and four blank plates for optional video audio telephone and network connectors Any of the plates mounted to the Connecting Surface can be rearranged or removed and replaced with Kramer passive wall plates or connector modules for interfacing A V type signals To mount a Kramer insert or con
6. Kramer Electronics Ltd USER MANUAL Model TBUS 1A Table Connection Bus Contents Contents 1 Introduction 2 Getting Started 2 1 Quick Start 3 Overview 4 Your TBUS 1A Table Connection Bus 5 Installing the TBUS 1A Table Connection Bus 5 1 Cutting an Opening in the Table 5 2 Installing the Required Wall Plates 5 3 Adjusting the Height of the Connecting Surface 5 4 Inserting the TBUS 1A through the Cut Out Opening 5 5 Installing the Cables 6 Using the TBUS 1A 7 Technical Specifications Figures Figure 1 TBUS 1A inside a Table Figure 2 TBUS 1A Table Connection Bus Top View Figure 3 TBUS 1A Connecting Surface Figure 4 Cutout Dimensions Figure 5 Inserting TBUS 1A into the Prepared Opening Figure 6 TBUS 1A Boardroom Installation Tables Table 1 TBUS 1A Table Connection Bus Features Table 2 TBUS 1A Connecting Surface Features Table 3 Technical Specifications of the TBUS 1A pu SMU 0 12 gt 0023 A We No QQ Ur FW Introduction 1 Introduction Welcome to Kramer Electronics Since 1981 Kramer Electronics has been providing a world of unique creative and affordable solutions to the vast range of problems that confront the video audio presentation and broadcasting professional on a daily basis In recent years we have redesigned and upgraded most of our line making the best even better Our 1 000 plus different models now appear in 11 groups that are clearly defined by functi
7. PAY FOR AND WHAT WE WILL NOT PAY FOR We will pay labor and material expenses for covered items We will not pay for the following 1 Removal or installations charges 2 Costs of initial technical adjustments set up including adjustment of user controls or programming These costs are the responsibility of the Kramer dealer from whom the product was purchased 3 Shipping charges HOW YOU CAN GET WARRANTY SERVICE 1 To obtain service on you product you must take or ship it prepaid to any authorized Kramer service center 2 Whenever warranty service is required the original dated invoice or a copy must be presented as proof of warranty coverage and should be included in any shipment of the product Please also include in any mailing a contact name company address and a description of the problem s 3 For the name of the nearest Kramer authorized service center consult your authorized dealer LIMITATION OF IMPLIED WARRANTIES All implied warranties including warranties of merchantability and fitness for a particular purpose are limited in duration to the length of this warranty EXCLUSION OF DAMAGES The liability of Kramer for any effective products is limited to the repair or replacement of the product at our option Kramer shall not be liable for 1 Damage to other property caused by defects in this product damages based upon inconvenience loss of use of the product loss of time commercial loss or 2 Any other damages whether incidental consequent
8. away from moisture excessive sunlight and dust Figure 1 TBUS 1A inside a Table 1 The complete list of Kramer wall plate devices for designing the Connecting Surface can be found on our Web site at http www kramerelectronics com 2 See compatibility restrictions in the Specification section 7 Your TBUS 1A Table Connection Bus 4 Your TBUS 1A Table Connection Bus Figure 2 and Table 1 define the TBUS 1A unit Figure 2 TBUS 1A Table Connection Bus Top View Table 1 TBUS 1A Table Connection Bus Features Feature Function Connec ing Surface See Figure 3 and Table 2 2 Black Textured Lid Has an opening for cable pass through covers the Connec ing Surface leaving the table surface neat and tidy 3 Outer Rim Fits over the table surface Enclosure Inserted into the table cutout 5 Height Adjustment Screws 10 screws on each side panel for adjusting the height of the Connecting Surface 6 Rubber Protectors Protect the table surface when moun ing the unit one on each side 7 Locking Butterfly Screws Tighten to lock the mounting butterfly screw one on each side 8 Mounting Butterfly Screws Tighten to secure the unit to the table surface one on each side KRAMER SIMPLE CREATIVE TECHNOLOGY Your TBUS 1A Table Connection Bus Feature Function 9 Mounting Brackets 2 units Place in the bracket slits after inserting the en
9. closure into the table for securing the unit to the table surface one on each side 10 Tie Holes Insert the self locking tie through the holes to fix the pass through cables to the inside walls of the unit 6 pairs of holes 3 for the front panel and 3 for the rear panel 12 Bracket Slits Located on the front and rear panels and on both sides of the unit For attaching the two mounting brackets on opposite sides Figure 3 and Table 2 define the Connecting Surface Figure 3 TBUS 1A Connecting Surface Table 2 TBUS 1A Connecting Surface Features Feature Function 1 Blank Plates Four blank covers that can be replaced with wall plates as required 2 Split Grommets Push apart slightly to insert cables 3 Split Brackets Support the split grommet for the pass through cables 4 Universal Power Socket Suitable for international power requirements 5 Adjustable Height Screw For adjusting the height of the Connecting Surface Holes 1 Some versions may not include tie holes 5 Installing the TBUS 1A Table Connection Bus 5 Installing the TBUS 1A Table Connection Bus To install the TBUS 1A perform the following steps 2 3 4 5 Cut an opening in the table see section 5 1 Mount the required wall plate items see section 5 2 Set the height of the Connecting Surface see section 5 3 Insert the unit through the hole and secure to the table see section
10. ial or otherwise Some countries may not allow limitations on how long an implied warranty lasts and or do not allow the exclusion or limitation of incidental or consequential damages so the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights which vary from place to place NOTE All products returned to Kramer for service must have prior approval This may be obtained from your dealer This equipment has been tested to determine compliance with the requirements of EN 50081 Electromagnetic compatibility EMC generic emission standard Part 1 Residential commercial and lightindustry EN 50082 Electromagnetic compatibility EMC generic immunity standard Part 1 Residential commercial and lightindustry environment CFR 47 FCC Rules and Regulations Part 15 Radio frequency devices Subpart B Unintentional radiators CAUTION B gt Servicing the machines can only be done by an authorized Kramer technician Any user who makes changes or modifications to the unit without the expressed approval of the manufacturer will void user authority to operate the equipment Use the supplied DC power supply to feed power to the machine Please use recommended interconnection cables to connect the machine to other components FCC and CE approved using STP cable for twisted pair products 11 For the latest information on our products and a list of Kramer
11. nector module do the following 1 Unscrew the two screws that fasten the blank plate to the connecting surface and remove the blank plate 2 Place the required Kramer insert over the opening insert the two screws to fix the Kramer insert in place and tighten them 5 3 Adjusting the Height of the Connecting Surface If needed you can adjust the connecting surface to one of four possible heights to accommodate large or bulky cables By default the height is set to the second level from the top To adjust perform the following 1 Remove the height adjustment screws while supporting the surface from underneath with your fingers 2 Use your fingers to bring the Connecting Surface to the required height screw and tighten it in place using the height adjustment screws 5 4 Inserting the TBUS 1A through the Cut Out Opening To install TBUS 1A in the opening 1 Carefully insert the unit into the prepared opening see Figure 5 2 Take the support brackets under the table and place them into the support bracket grooves on both sides of the unit see Figure 2 3 Verify proper alignment of the unit before tightening the mounting screws 1 The complete list of Kramer wall plates and module connectors is on our Web site at http www kramerelectronics com 7 Installing the TBUS 1A Table Connection Bus Screw both mounting butterfly screws upward until they reach the table surface from underneath Tighten firmly
12. on Thank you for purchasing the Kramer TBUS 1A Table Connection Bus which is ideal for boardrooms conference and training rooms The package includes the following items e TBUS 1A Table Connection Bus e 2table clamps e Power cord e 6 self locking ties e Metal template i 4 e This user manual 2 Getting Started We recommend that you e Unpack the equipment carefully and save the original box and packaging materials for possible future shipment e Review the contents of this user manual e Use Kramer high performance high resolution cables 2 1 Quick Start This quick start chart summarizes the basic setup and operation steps 1 GROUP 1 Distribution Amplifiers GROUP 2 Switchers and Matrix Switchers GROUP 3 Control Systems GROUP 4 Format Standards Converters GROUP 5 Range Extenders and Repeaters GROUP 6 Specialty AV Products GROUP 7 Scan Converters and Scalers GROUP 8 Cables and Connectors GROUP 9 Room Connectivity GROUP 10 Accessories and Rack Adapters GROUP 11 Sierra Products 2 We recommend that you use only the power cord supplied with this device 3 In addition to the cardboard template provided an optional metal template is available for order 4 Download up to date Kramer user manuals from our Web site http www kramerelectronics com 5 The complete list of Kramer cables is on our Web site at http www kramerelectronics com 1 Getting Started Step 1 Mount the machine
13. see Figure 5 Screw the locking butterfly screws downward until tight against the mounting bracket 5 5 Figure 5 Inserting TBUS 1A into the Prepared Opening Installing the Cables To insert the pass through cables for example to connect a laptop do the following 1 Remove the two screws attaching the split pass through bracket 2 Remove the split grommet 3 Insert the cable through the rectangular opening 4 Open the split grommet slightly and insert the required cables 5 Place the split bracket around the grommet and position this assembly over the Connecting Surface frame 6 Place the two screws appropriately and tighten the split bracket together with the grommet and inserted cables to the Connecting Surface 7 Insert the self locking ties through the tie holes to secure the cables to the inside walls of the enclosure KRAMER SIMPLE CREATIVE TECHNOLOGY Using the TBUS 1A 6 Using the TBUS 1A Once the TBUS 1A is installed you can easily customize it to your own needs by plugging in the required A V equipment as illustrated in the example in Figure 6 Video Conference Switcher Scaler Power Amplifier with Speakers Computer Graphics Source Laptop Figure 6 TBUS 1A Boardroom Installation Technical Specifications 7 Technical Specifications Table 3 includes the technical specifications Table 3 Technical Specifications of the TBUS 1A

Download Pdf Manuals

image

Related Search

Related Contents

Draper Paragon Large Electrically Operated Projection Screen User's Manual  5000シリーズ 取扱説明書    Référentiel "Activités  Manual em PDF  えこだんLASSELE DM&LMT取扱説明書  MAGHRÉBINS EN EUROPE - Annuaire de l`Afrique du Nord  wash filters register your dyson 2 year guarantee today  Gorenje RB60298OA combi-fridge  