1. L Black Masking Borders Optional on AV format standard on all others L Wall Mount Bracket Kit Includes two brackets L Endcap Ceiling Tile Flange Kit 2 per kit LJ Ceiling Tile Flange for front and or rear of case 12 lengths How many 12 lengths do you need Control Options Please Note This Draper motorized screen comes with one 110V 120V AC 3 position wall switch silver wall plate with black rocker Total number of 110 120V AC switches switches operate independently 1 2 threaded rod for suspending Case Dimensions 1314 high x 12 deep Optional wall mounting brackets extend 134 beyond each end of case hole centers are 1 from end of case Paragons with cases longer than 300 require special handling L Substitute white switch es for silver wall plate with black rocker C Serial or Network Communication Complete Serial amp Network Control Planning Sheet LJ ci Low Voltage Control Module LVC III 24 Volt 3 Button Switch Number of 24V switches two per end with plastic plugs Left hand motor location only on Paragon Please see back page for dimensional diagrams of case and L Radio Frequency Remote Control only with 24v LJ Infrared Remote Control only with 24v Ll Optional Key Operated Switch Power Supply Key Switch On off L 3 Position Key Control LJ 3 Position Switch with Hinged Key Locking Coverplate L Optional Video Inter
2. by Underwriters Laboratories Inc for the U S and Canada Suitable 300 146 x 260 151 x 264 274 484 for use in environmental air space in accordance with Section 300 22 c of the National 304 160 x 284 165 x 288 398 508 Electrical Code and Sections 2 128 12 010 3 and 12 100 of the Canadian Electrical ee a Code Part 1 CSA C22 1 U S Patent No 6 873 461 394 173 x 308 178 x 312 322 5 2 Options 384 187 x 332 192 x 336 346 616 Wall Mount Bracket Kit Kit includes two structural steel brackets and hardware to attach Custom Size brackets to case Hardware for mounting to wall structure by others Endcap Ceiling Tile Flange Kit Extruded aluminum finished white Attaches to endcaps Each kit contains two 2 flange pieces and hardware for attaching trim flanges to endcaps Ceiling Tile Flange for Front of Case Each kit includes 12 extruded aluminum finished white Attaches to front of case Hardware for attachment to case included Downloadable 3 part specifications are available at www draperinc com Please Mark Appropriate Selections Select Viewing Surface screen by others L Matt White 3 a 16 threaded rod L Glass Beaded use for adjusting Optional Accessories deflection in extremely LI extra Screen Drop Total screen height cannot exceed 24 ong uns z nore L Same color as viewing surface standard on AV format screens L Black standard on all other formats Length of total drop
3. 120V Line Black Single gang box by others l l l l l l l l l l l l l l l l l l l l l l l l l l Min 4 x 21 8 x 17 s deep Io 3 shown More or less equally I l feasible cAn Location of key I operated on off L switch if furnished l l 1 To 110 120V Line Low Voltage IR Remote or RF Remote LVC III Internal Screen Wiring White Common to screen amp 110 120V AC Neutral White Common Red to screen directional ees F Red Up Brown to screen directional 7 4 7 Black Down Yellow to 110 120V AC Hot 1 4 Green Ground Black to 110 120V AC Hot 7777 T TTF boro Green Ground i o t l i eo bSu sees Dashed wiring by electrician lt gt 1 o TETEE Low voltage wiring by others 7 fo eee e i ee i 0 Eye Port for IR Eye RF Receiver or LED 7 110 120V Wall Switch For more than one of o a 6 Line these a splitter is required P Lot Location of key BI EGE ice svinas are Fi operated on off keas COM WNE ESE sien o switch if furnished aA UP Red Gu Mowe Un we D a Sel a we ie ee wed ee Control Aux Port for connecting additional LVC III Switches modules up to six total can be linked 24v DC connect from Aux to Eye For more information and wiring diagrams for low voltage PROJECT multiple motors and network communication please see
4. Draper Screen and Lift Controls Planning Sheet Draper SUPPLIER Screens and Lift Controls Wiring Manual and wiring diagrams supplied with individual items DATE SSM REVISE b d gt e o5 bd SE www draperinc com 765 987 7999
5. Large Electrically Operated Projection Screen With Motor In Roller Gs Children amp Schools Paragon Specifications Paragon Dimensions amp Data projection screens size ___h x W i electrically operated 110 120v AC 60 Hz 3 wire motor mounted inside REENGUARD S an ae Lbs l screen roller 2 5 amp draw instantly reversible lifetime lubricated Indoor Ait Quality Certified J AY Enorma with internal thermal overload protector and mechanical brake Motor 15x 20 350 440 mounted with sound absorbing fixtures Left hand motor location only _ Baa Preset accessible limit switches J box inside case accessible via 22 a N 20 x 20 250 450 ga steel cover plate Entire roller and drive assembly easily removable RAPER 11 x 22 274 484 through bottom of case wa 161 2 x 22 274 494 Roller to be 6 OD x s wall steel tube Roller brackets to be painted Ec Vi sion 29 y 29 274 504 white and to have double row radial ball bearings Viewing surface to 12 x 24 298 528 be GREENGUARD for Children and Schools certified Matt White Part of the Draper 18 x 24 308 538 Glass Beaded flame and mildew resistant Matt White and High 1 TM C ae ee EcoVision range 24 x 24 298 548 ontrast Grey viewing surfaces shall qualify as low emitting and meet all of the requirements of the GREENGUARD for Children and of products 13 x 26 322 5 2 Schools and GREENGUARD certification program which are emissio
6. face Control LI vic 115 LI Override Switch X VICs are compatible only with the PROJECT LI vic 12 LI Override Switch X Override Switch and not with any LI vic 6 LI Override Switch other wall switches or controls ARCHITECT CONTRACTOR SUPPLIER 411 S Pearl St Spiceland IN 47385 USA I 765 987 7999 www draperinc com I fax 765 987 7142 Copyright 2008 Draper Inc Form Paragon_Sub08 R DATE Printed in U S A optional wall mounting bracket REVISED Paragon by Draper Page 2 of 2 Case Dimensions Optional Wall Mounting Bracket 4 3 s dia Please Note Optional wall brackets add 134 per bracket to case length Wall mounting bracket hole location is 1 from end of case Wiring Diagrams Single Station Control Multiple Station Control L A we commen o p AE we aon o Black Down o Black Down r Red Up pade Red Up o Green Ground l d Green Ground L ai Cap off with wire Dashed wiring soe l by electrician I I l l l l l l l 1 Control Single gang box by others Red Blue switch Min 4 x 21 8 x 17 8 deep l l e l o m ____ Blue I Black Black i Dashed wiring l k i l by electrician l Red Blue l Pe _ l l l l l Location of ke rh y l operated on off i Blacki L switch if furnished i l l Red Blue l To 110
7. ns of total volatile 19 2 x 26 322 582 organic compounds lt 0 22 mg m formaldehyde lt 0 0135 ppm total aldehydes lt 0 043 14 x 28 346 616 ppm individual volatile organic compounds lt 1 1000 TLV and lt chronic REL and 21 x 28 346 626 total phthalates lt 0 01 mg m Dowel shall be 1 OD steel tube with black polyethylene Nominal Image Overall Case NetWt Qty endcaps Diagonal AreaHxW Size Length _ Ibs Case constructed of extruded aluminum Bottom of case fully enclosed except for slot 4 3 NTSC Video Format allowing fabric passage Bottom closure panel shall be extruded aluminum finished white 35 177 x 236 182 x 240 350 440 and may be removed manually for access to roller and drive unit Closure panel shall be D7 194 x 260 199 x 264 274 484 held in place by screw and bracket at each end of case Aluminum endplates with integrated s steel brackets for suspended mounting shall be fastened to extruded case with thread 30 212 x 284 217 x 288 298 528 cutting screws Eyebolts shall be provided for use in hoisting screen Case support brackets 3212 230 x 308 235 x 312 322 572 shall be welded steel channel riveted to exterior of case 35 248 x 332 253 x 330 346 616 Three position control switch or switches specify number shall stop or reverse screen at 16 9 HDTV Video Format any point Controls to be furnished complete with cover plate 970 133 x 236 138 x 240 950 440 Entire unit certified