Home
9448 - Templewood Security Systems
Contents
1. 9448 Installation and User Guide Compatible Equipment 9040 Internal Sounder 660 Speech communicator 496327 Issue 1 1 of 6 9448 INTRODUCTION The 9448 is a3 zone control panel with separate Entry Exit and PA zones designed specifically for domestic installations The control unit PCB is built into a polycarbonate box with keypad and eight indicator LEDs on the front of the lid Technical Specification Dimensions hxwxd 212x212 x 68mm Weight Approx 1 1kg without stand by battery Power Supply System Power Supply 230VAC Ambient Temp 20 Quiescent Panel Power 70mA nominal Standby Battery 12 Volt 2 1AH rechargeable lead acid Gel Type battery Outputs Bell Strobe and O P are open collector transistor outputs Bell Strobe 500mA Max AUX for detectors 300mA 12VDC Communicator Outputs PA Intruder Outputs PIR Set Latch Shock Sensor Reset LS 9040 1 max Fuses F1 Battery 2A Quick Blow F2 12V AUX 1A Quick Blow Caution When replacing fuses use the ratings quoted above The control panel has none of the required software functions to allow it to conform with the required standards for remote signalling in the UK Scantronic recommend that you use this system for bell only installations Wiring Figure 1 shows the layout of the 9448 PCB and its connector 2of6 496327 Issue 1 9448 Programming 42VAUX Normally
2. crewdriver blade Key in 1234 Key in 0 then ENTER followed by 7890 You must now reprogram the system Engineer Walk Test Allows the engineer to test all devices on the system 1 2 4 Enter programming mode Key in 97 ENTER The panel gives a continuous tone Open and close each detector contact in turn When a detector contact is open the panel gives an interrupted tone and flashes the zone LED Press OMIT to stop the walk test Note that the Engineer s walk test allows you to test all zones including PA zones zone tampers and panel and bell tampers The user s walk test does not allow this User Commands Set Unset System User code Omit zone Part set 2 OMIT and or 3 OMIT User code Test Bells 4 ENTER User code The system sounds the internal sounder for three seconds followed by the bell and strobe for three seconds Walk Test 5 ENTER User code Key in User code to end test Change User code 6 ENTER current user code 6 of 6 new user code ENTER 496327 Issue 1
3. d tamper bell tamper and the global zone anti tamper Leaving Programming Mode 1 Connect the battery 2 Complete the connections between the 12V terminal and the external sounder and 12VAUX and the detectors Note The SAB module in the external sounder will continue to ring until the hold off supply is connected or until the bell cover lid tamper switch is closed 3 Close the panel lid 4 Key in 99 ENTER to leave programming mode You are now in user mode To Re enter Programming Mode You can re enter programming mode at any time when the panel is in the unset mode Key in 0 then ENTER followed by the engineer access code Open the control panel lid You are now in programming mode Restoring Factory Defaults The control panel can retain all programmed information and access codes if both mains and battery power fail When power is restored the panel will simply need resetting with the customer or engineer s access code If the installer wants to return the panel to the factory default settings then 1 Power down the control panel mains and battery 2 Locate the pair of Molex pins marked RST near the microcontroller 3 Place a small screwdriver blade to short between the RST pins 4 With the blade still across the pins apply battery power then mains The system loads the factory default user and engineer s access codes 496327 Issue 1 5 of 6 Eningeer Walk Test 9448 ONO Remove the s
4. eps twice to show that it has accepted the command The panel gives a single error tone if you enter an incorrect command or if you close the lid Re enter the correct command 3 Key in 99 ENTER to leave programming mode when you have fin ished You will then be in user mode Engineer Program Command List To change Key in Followed by Notes Defaults Engineer Code 20 ENTER new code ENTER 4 digits 7890 User Code 1 21 ENTER new code ENTER 4 digits see note 1 1234 Zone 2 Entry 36 ENTER 0 ENTER Normal Alarm v Route 1 ENTER Entry Route Auto Re Arm 40 ENTER 1 ENTER Never rearm y 4 ENTER Rearm three times Bell Duration 42 ENTER 1 ENTER 90 seconds 2 ENTER 3 minutes 3 ENTER 10 minutes 4 ENTER 20 minutes v Entry time 43 ENTER 1 ENTER 20 seconds v 2 ENTER 1 minute 3 ENTER 2 minutes 4 ENTER 4 minutes Exit time 44 ENTER 1 ENTER 10 seconds y 2 ENTER 30 seconds 3 ENTER 1 minute 4 ENTER 2 minutes Bell Trigger Type 50 ENTER 0 ENTER SAB y 1 ENTER SCB 4of6 496327 Issue 1 9448 Leaving Programming Mode Prog O P 51 ENTER 0 ENTER PIR set latch y 1 ENTER Shock reset Zone 1 in Part Set 52 ENTER 0 ENTER Normal Alarm y 1 ENTER Entry Exit Walk Test 97 ENTER Trigger detectors Press OMIT to exit test Leave Program 99 ENTER See note 2 Notes 1 The end user may change the user codes see separate user guide 2 If the internal sounder activates when you use this command then check the li
5. open P contacts e g AT stairmat EE E E contact PA z Communicator a output pins E Pi l 4321 cece SHSSISS S T T T T 1 TELELE 3 Intruder Strobe E o J LL 16 Ohm Loudspeaker 1 Max internal speaker HO PIOH 3 HO PIOH 3A Buy Aiddy 34 Figure 1 9448 PCB Layout Programming Initial Start Up Before applying power to the control panel ensure that all Zone circuits are connected link out any circuits not used DO NOT connect the 12V terminal to the external sounder or 12VAUX terminals to the detectors at this stage Caution You may damage the panel if you connect bell and AUX power before you power up the system 1 Apply mains to the control panel The green power LED lights and the internal sounder will sound Ignore any other lights 2 Key in the factory default user access code 1234 The internal sounder stops Ignore any other lights 496327 Issue 1 3 0f6 Changing Default Programming 9448 3 Key in 0 then ENTER followed by the factory default engineer access code 7890 The Day LED goes off 4 Open the control panel lid You are now in programming mode Changing Default Programming To change the factory defaults the panel must be in programming mode Then 1 Key ina two digit programming command followed by ENTER See Engineer Program Command List 2 Key in the correct digit for the option you want and then press ENTER The panel be
Download Pdf Manuals
Related Search
Related Contents
Tablones y Listones Sólidos de 3/4" (1,9 cm Hitachi DV18DSDL Servicio de búsqueda PATENTSCOPE Guía del usuario Avaya BCM 2.5 Attendant Console User's Manual Untitled User Manual - B&H Photo Video Digital Cameras, Photography Tronconneuse carrelage Clipper TT20EM Instruction Manual FPSTCML900 PCA96PS-xxA 取扱説明書 Copyright © All rights reserved.