1. 6 Make sure to connect the polarity of battery side and the unit correctly Positive pole Red of battery to the positive terminal of the unit Negative pole Black of battery to the negative terminal of the unit Step 7 Put the covers back to the external battery terminals Step 8 Take the DC breaker on 6 Trouble Shooting Use the table below to solve minor problems Problem Probable Cause Solution Utility power is normal but the unit is in battery mode AC input power cord is not connected well Check AC input power connection Input breaker is activated Reset the input breaker When power fails the backup time is shorten The unit is overload Remove some non critical loads Battery voltage is too low Charge the unit at least 8 hours Battery capacity is not full even after charge the unit for at least 8 hours Check the date code of the battery If the batteries are too old replace the batteries No LED display on the front panel when the utility power is normal The unit is not turned on Press power switch to turn on the unit Battery is not connected well Check the external battery cable and terminal Make sure all the battery connections to the unit are all correct Battery defect Replace the batteries Battery voltage is too low Charge the unit at least 8 hours
2. Atom Series Quick Guide I Product Introduction Atom is a compact unit which combines both benefits of UPS and inverter for long time operation With built in voltage stabilizer it works as a UPS to accept wide input voltage range and convert to stable and pure power source to the connected devices Besides it also can provide stable power to a various of electronic devices from personal computers energy saving bulbs television to small inductive devices such as fans It is perfect choice for home owners or small office users in the unstable power area y J Product Overview Front View Back View B o i A oO 99 o9 oe noe 00 7 Power switch India Type Universal Type Line mode indicator green lighting AC input Output receptacles Circuit breaker External battery terminal Battery mode indicator yellow flashing Q Fault indicator red lighting Important Safety Warning SAVE THESE INSTRUCTIONS Personnel Precaution CAUTION Careful to reduce the risk or dropping a metal tool on the batteries It could spark or short circuit the batteries and could cause an explosion CAUTION Remove personal metal items such as rings bracelets necklaces and watches when working with batteries Batteries can produce a short circuit current high enough to make metal melt and could cause severe burns CAUTION Avoid touching eyes while working near batteries CAUTION Have
3. ate battery cable Please refer to Important Safety Warnings Section for the details Step 3 There are two terminal types Type 1 Screw battery cables to terminals with the M5 nuts Do NOT place anything between the flat part of battery terminal and the battery cable ring terminal or overheating may occur Type 2 Simply screw battery cables to terminal with flat screwdriver See Fig 1 Type 2 Fig 1 Battery cable connects to the terminal Step 4 Install a DC Breaker in a positive battery line The rating of the DC Breaker must be according to the inverter s battery current 50 Amp Keep the DC breaker off see Fig 2 Step 5 Connect battery cables to the external batteries Note For the user operation safety we strongly recommend that you should use tapes to isolate the battery terminals before you start to operate the unit 1 Single battery connection Refer to Fig 2 When using a single battery its voltage must be equal to the Nominal DC Voltage of the unit see below Table 1 Table 1 Model Nominal Battery DC Voltage Atom 600 12VDC 2 Multiple batteries in series connection Refer to Fig 3 All batteries must be equal in voltage and amp hour capacity The sum of their voltages must be equal to the nominal DC Voltage of the unit Fig 3 3 Multiple batteries in parallel connection Refer to Fig 4 Each battery s voltage must be equal to the Nominal DC Voltage of the unit Fig 4 Step
4. partment CAUTION Use insulated tools to reduce the chance of short circuit when installing or working with the inverter the batteries or other equipments attached to this unit CAUTION For battery installation and maintenance read the battery manufacturer s installation and maintenance instructions prior to operating A Specifications Model Atom 600 CAPACITY 600 VA 300 W INPUT Voltage 230 VAC Voltage Range 140 300 VAC Frequency 50 Hz or 60 Hz OUTPUT Output Voltage Batt mode 10 Frequency Range Batt mode 50 Hz 1Hz or 60 Hz 1 Hz Transfer Time 13 ms max Waveform Simulated Sine Wave BATTERY Battery Voltage 12 VDC Maximum Charge Current 13A PHYSICAL Dimension DxWxH mm 358 5 X 96 8 X 146 5 Net Weight kgs 5 8 ENVIRONMENT Humidity 0 90 Temperature 0 40 C non condensing J 5 Installation NOTE Before installation please inspect the unit Be sure that nothing inside the package is damaged Q Connect to Utility and Charge Plug in the AC input cord to the wall outlet The unit will automatically charge the connected external battery even though the unit is off Connect External Battery Step 1 Take away the cover of external battery terminal Step 2 Following battery polarity guide printed near the battery terminal RED cable to the positive terminal BLACK cable to the negative terminal WARNING Please use the appropri
5. plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes CAUTION NEVER smoke or allow a Spark or flame in vicinity of a battery CAUTION If a remote or automatic generator start system is used disable the automatic starting circuit or disconnect the generator to prevent accident during servicing CAUTION The unit is designed for indoor use Do not expose this unit to rain snow or liquids of any type CAUTION To reduce risk of injury only use qualified batteries from qualified distributors or manufacturers Any unqualified batteries may cause damage and injury Do NOT use old or overdue batteries Please check the battery type and date code before installation to avoid damage and injury WARNING It s very important for system safety and efficient operation to use appropriate external battery cable To reduce risk of injury external battery cables should be UL certified and rated for 75 C or higher And Do not use copper cables less than 10AWG Table 1 Minimum Recommended Battery Cable Size versus Length Typical Amp 1 meter one way Dia mm Atom 600 50A AWG 8 6 0 CAUTION Do not disassemble the inverter Contact with the qualified service center when service or repair is required WARNING Provide ventilation to outdoors from the battery compartment The battery enclosure should be designed to prevent accumulation and concentration of hydrogen gas at the top of the com