INSTRUCTION MANUAL PCE-JR 911 www.pce
Contents
1. www pce industrial needs com Tursdale Technical Services Ltd Unit N12B Tursdale Business Park Co Durham DH6 5PG United Kingdom Phone 44 0 191 377 3398 Fax 44 0 191 377 3357 info tursdaletechnicalservices co uk http www industrial needs com INSTRUCTION MANUAL PCE JR 911 53 info Otursdaletechnicalservices co uk FINS TOC HON MANUAL 1 DATA O GU CHOU ATEENA EET rene 3 2 Material SUpDIIEd a e s 3 s A AA E A EEA N AEA A E E E E 3 3 1 IR thermometer with laser targeting sscscccsssssssssssscsssssscssssecssssscsssssssssssssssssssssssssssssssssscsecs 3 3 2 Procedure Programming Function seeessecessoceessccessoccessccessoceessocesscceessocesscceessoeessoceesscocessoceessoeessoeeesse 4 DO SU ALAIOGUER FUR CHON oase AA ENN NENNE SS 5 A G OMPD ARS ON Table eramaal tn aa 5 IFON VOW croc cas ceca ce cases SE E O EE T E E E A 6 O aDer REN 279727 09723477 oionn aoa E NO E EEN E innincen 7 ABANG HE DIE EM ER LEE EU Er er Eee 7 8 FUNCTION IR thermometer with laser tarQetind 1sssscsssssssecssssssessssssssssssssssesesssssass 9 9 FUNCTION Procedure programming ss1ssscsscssssssssssssssssssscsncssssssssssssensassansnsnsssnssnsassess 9 10 FUNCTION Data logger 2222222 eee eres kaane aa kasaka ka aaasta is 10 11 FUNCTION Setting Parameters aruavunravaavnnnavaannnanavnannnnavaaennnanaanannanaaea 14 TZ FUNCGTION Link WIA PG AAA m 15 D info Otursdaletechnicalservices
2. co uk 1 Introduction Thank you for purchasing this IR Meter Printer This unit has been developed to meet your maximum satisfaction with its user friendly design Please review the entire manual for a complete overview of how to operate this new IR Meter Printer 2 Material Supplied Check for damaged or missing parts in your IR Meter Printer before starting The IR Meter Printer Set should contain 1 Meter 2 4pcs AA batteries 3 Printing Paper 4 Operation manual 3 Features This IR Meter Printer eguipped with three functions e IR thermometer with laser targeting e Procedure programming function o Data logger function Please refer to below features of each function for clear understanding 3 1 IR thermometer with laser targeting Temperature Range PCE info Otursdaletechnicalservices co uk 40 500 Resolution 0 1 unit lt 100 or 1 unit Unit is or Accuracy 3 or 3 Whichever is greater Repeatability 1 Emissivity Adjustable from 0 3 1 0 Response time 0 2 seconds Backlight Laser sighting Yes Yes Distance Ratio 8 1 Printer Interface with PC 38 mm Thermal Printer 80mm x 30 thermal paper RS 232C TTL level Power supply AA x4 Battery or DC 9V 1000mA adaptor w 5 5 x 2 0mm Center plug Center is positiv Operating current 500mA Printing 6MA IR active 2MA IR standby Auto Power off No operation for 10 seconds at norma
3. seeing the battery symbol flashing on the right up corner of the LCD means the batteries are weak 03 11 27 10 14 49 If the power is too low to operate the IR printer printer will reset with below indication on LCD monitor Low Power please change the battery Follow the steps to remove and replace batteries 1 Open the batteries set cover on the rear side 2 Remove the expired batteries 3 Insert new 4pcs AA batteries and make sure the batteries are inserted with correct polarity 4 Put on the cover 53 info Otursdaletechnicalservices co uk 6 FUNCTION IR thermometer with laser targeting 1 Press ON key to enter IR mode LCD will display real time target temperature until ON key released After releasing the ON key LCD will hold the last value for 10 seconds and then auto power off 2 Press ON key and key at the same to in active the laser targeting while measure the temperature Once releasing the key laser targeting function activated again 3 Press PRINT key to print out current value date and time 9 FUNCTION Procedure programming 1 Press PROC key to enter procedure mode 2 There are 1to 4 procedures included in this function Press SET key to select the procedure number you want If selecting 3 LCD will display as below 3 01 02 03 04 05 3 How to name the procedure Make sure the procedure number you choose has been highlight Press ENTER key one
4. Ft Begin 03 01 01 End 99 12 31 Start 00 00 00 Suspend 23 59 59 Rate 1 Start Now Yes 3 How to set the data logger parameters Press for forward and for backward to choose the parameters Pressing alohanumeric keys to modify the parameters one by one Press ENTER key to start the data logger 10 PCE info Otursdaletechnicalservices co uk Begin means begin date MM DD YY or DD MM YY or YY MM DD it depended on what is the date mode set in SET function End means end date same as above Start means start time HH MM SS Suspend means stop time HH MM SS Rate means the time period to get the data For example 60 means to get the value every 60 seconds The rate could be from 1 to 9999 Ff Begin 03 11 22 End 03 11 23 start 08 05 00 Suspend 08 30 00 Rate 60 start Now Yes 5 Meter will record date time and value when the data logger is activated Please refer to below figure FI LOGGING 01 11 2208 05 00 F 03 11 22 08 07 30 6 How to stop data logger Press 0 twice to stop the data logger or the data logger will automatically stop after sampling 99 points 11 info Otursdaletechnicalservices co uk 7 Press PRINT to print out data logger data Print will appear on LCD If OK press PRINT again to continue If NO press LOG to back to data logger function Press 0 to stop printing Please be reminded that while data logger is still in recording status all the other fun
5. ctions of the meter could not be activated Please refer to below printed data Single print D XXX X C F Notei MM dd hh mm ss D XXX X C F mm dd hh mm ss Motes E XXX x C F mm dd hh mm ss X X X company Procedure Table print 12 info Otursdaletechnicalservices co uk Procedure Measure I Tr ao a ater aetna ae Procedure Name Total XXX rec D Unit C D 01 xxx x C F Oven A i aa als D 99 xxx x C F Logger Table print 13 info Otursdaletechnicalservices co uk Logger Measure 1 Fromm nm rage Logger Name Begin vy mm dd End vy mm dd Start hh mm ss Suspend hh mm ss Rate XXXX Total XXXX rec D Unit C 8 01 xxx x C F mm dd hh mm ss 1 99 xxx x C F mm dd hh mm ss mm dd xx 8 Press LOG key at least 2 seconds to clear data logger data 11 FUNCTION Setting Parameters 14 PCE info Otursdaletechnicalservices co uk 1 Press SET key to enter setting mode while meter is at IR mode 2 Parameters could be set by users including LCD contrast 1to 9 bright to dark Print contrast 1to 9 light to heavy Emissivity Unit or Date mode MM DD YY or DD MM YY or YY MM DD pressing ENTER to select the preferred mode Date and time Please see below figure LCD Cont 5 Prn Cont 5 Emi Rate 0 95 Unit F Date YY MM DD SetClock YY MM DD hh mm ss 03 11 22 08 11 08 3 Press SET twice at IR mode to enter ID se
6. l mod 60 seconds for others mode Operation temperature 0 50 Operation humidity Less then 90 RH Dimension Remarks 208 x 70 x 53 mm Software for downloading data to PC is optional 3 2 Procedure Programming Function D info tursdaletechnicalservices co uk Procedure capacity 4 procedures in total Indicated as 1 to 4 with procedure name Measure point 99 measure points in each procedure Measure point content Each measure point consists of point number point name and temperature value 3 3Datalogger Function Data logger capacity 4 data logger settings Indicated by 5 to 8 Data logger setting Setting by Begin Date End Date Start Time Suspend Time Rate 99 measure points in each data logger setting Measure point Each measure point consists of point number point title and temperature value Remarks Rate means the time period to get the temp Value For example 20 means getting temp value every 20 seconds during Start Time and Suspend Time Point name consisted by logging s date amp time automatically 4 Comparison Table Function Procedure Logger Number 1 to 4 5 to 8 Name User defined or automatic Automatic Note 1 Note 2 Measuring User pressed Automatic measure and store Sampling by specified setting by user Note 3 Max point 99 99 ON key to measure then press enter key to confirm store Note 1 Meter automatic defines title info Otu
7. rsdaletechnicalservices co uk if user doesn t key in any The name is consisted by current date and time For example if point name is 05 06 09 21 51 means the date is 6th May and the time is 09 21 51 Note 2 Meter automatic defines the name of the measured point by current date and time Note 3 Logger setting defined by Start Date Begin time Suspend time End Date and sample rate Each logger starts from Start Date 8 time sampling by specified rate until Suspend time Start again next day until End Date Logger is stopped by reaching End Date or 99 points or press 0 key twice 5 Front View Please refer tobelow photo forthe function of each key onthe meter Paper Cover info Otursdaletechnicalservices co uk Pressing for changing meter parameters Procedure function For pnnting OL Data logger function PROC LOG SEL PRINT 7 in d Pressing for o Fran tn f back light P f rassing grup i s A Pressing for down COND or laser targeting y TE ON OFF 8 7 a Pressing for detectingtemp 6 Paper Replacement For feed paper and confirming setting Feed the paper when it s held down except printing Please follow the pictures to scissor out a paragraph from supplied printing paper To make easier feeding the paper insert the sharp cut to the cartidge of the printer Keep the matt surface of the paper upward when inserting the paper 7 Battery info Otursdaletechnicalservices co uk Replacement When
8. time and the highlight will start flashing Editing function is valid only when above highlight is flashing Pressing alphanumeric keys to edit the name release the alphanumeric keys when you select the word you need Press 0 key for a space or press for forward for backward Press ENTER key to finish and store the editing 4 How to name the measured point First of all press or to find the point you need Press 1 to quickly skip to 10 11 or press 2 to skip to 20 21 Or press 9 to skip to 90 91 etc The point naming procedure is the same as How to name the procedure section Meter will also automatic store current date and time as point name if user didn t edit any 5 Press ON to get the current temperature and then press ENTER to save the value User will see the LCD shown as below 9 info Otursdaletechnicalservices co uk 3 01 11 22 07 54 33 6 Press PRINT to print out procedure saved data Print will appear on LCD If OK press PRINT again to continue If NO press PROC to back to procedure function Please refer to below for the printed out data 7 How to delete data Press PROC key at least 2 seconds to clear procedure name point name or temperature value 10 FUNCTION Data logger 1 Press LOG key to enter data logger mode 2 There are 5to 8 loggers included in this function Press SET key to select the data logger number you want If selecting 7 LCD will display as below
9. tting Press Enter to enter modification mode ID parameter will be highlight and flashing Choose the desired characters and then toggle enable or disable by pressing ENTER key The desired character will appear on printing data when it is in enable mode 12 FUNCTION Link with PC Please be reminded that the software amp cable for this function is optional and please consult with your supplier if you would like to order this optional item 1 Plug the cable to your computer and follow up the software install operation procedure indicated in software manual 2 1 he software could be used for below functions Upload and Download 1 to 4 procedure data including updating procedure name and point name Download 5 to 8 data logger data 15 info Otursdaletechnicalservices co uk In this direction will find a vision of the measurement technigue http www industrial needs com measuring instruments htm NOTE This instrument doesn t have ATEX protection so it should not be used in potentially explosive atmospheres powder flammable gases 16
Download Pdf Manuals
Related Search
Related Contents
CO2 Infra Red Transmitter/ Sensor Units Enermax Sgalaxy Evo Service Manual for Prophet ワンワンとうーたんなかよしホールハウス取説表裏 納品.eps Hyundai D468FL Targus Notebook Security DEFCON® CL Combo Cable Lock Название документа Epson EB-1880 Rapport_final_AGBD_enquete_satisfaction YASKAWA INVERETER CA V1000 Copyright © All rights reserved.