1. Sensitivity nominal 12dB SNAD Channels Scan Rate Search Rate Time Accuracy Audio Output normal Power Requirements Antenna External Jacks Accessories Speaker Operating Temp Storage Temp Size Weight 0 5 uV 0 52 1 72 MHz 0 3 uV 25 88 MHz 0 4 uV 108 137 MHz 0 3 uV 137 174 MHz 0 3 uV 406 512 MHz 0 4 uV 806 960 MHz 300 30 channels x 10 Banks 50 channels per second 50 steps per second 20 seconds per month at normal temperature 25 C 5 C 0 9W Max 230V AC 10 50Hz Telescoping included AM Radio Loop Antenna included Antenna jack AM Radio Antenna Jack Headphone Jack DC 12V Power Jack AC Adapter AD 973 8 ohm 2 watt 10 C to 50 C 20 C to 60 C 209 W x 147 75 D x 80 7 H mm 600g without batteries and antenna Features specification and availability of optional accessories are all subject to change without notice UB355ZH UBC360CLT indd 29 Technical Specifications 29 9 2008 04 08 15 56 06 9 Declaration of Conformity We Uniden Corporation 2 12 7 Hatchobori Chuo ku Tokyo 104 8512 Japan declare under our sole responsibility that this equipment Uniden Bearcat model UBC360CLT is in compliance with the essential requirements and other relevant provisions of the Council Directive 1999 5 Declaration of Conformity 4 UB355ZH UBC360CLT i
2. 9 Uniden UBC360CLT OWNER S MANUAL OWNER S MANUAL UB355ZH UBC360CLT indd 1 Precautions Before you read anything else please observe the following Changes or modifications to this product not expressly approved by Uniden or operation of this product in any way other than as detailed by this Reference Guide could void your authority to operate this product The installation possession or use of this scanning radio in a motor vehicle may be prohibited regulated or require a permit in certain country cities and or local jurisdiction Your local law enforcement officials should be able to provide this information regarding the laws in your community EARPHONE WARNING You can use an optional 32 Q stereo headset or earphone with this scanner Use of an incorrect earphone or stereo headset might be potentially hazardous to your hearing The output of the phone jack is monaural but you will hear it in both headphones of a stereo headset Set the speaker volume to a comfortable level before plugging in either a monaural earphone or a stereo headset of the proper impedance 32 Q Otherwise you might experience some discomfort or possible hearing damage if the volume suddenly becomes too loud because of the volume control or squelch control setting This is particularly true for the type of earphone that is placed in the ear canal Precautions a UB355ZH UBC360CLT
3. slide the mode switch to Scanner HOLD SCAN Programming Memories You will first need to determine the frequencies you want to program Make a list of the frequencies you want to program then organize them in up to 10 groups of 30 or fewer and fill out the table below It always helps to plan and organize what you want to do before you start so don t skip this important step The numbers in the left hand columns below correspond to your scanner s memory numbers 09 1 COIN OD Oy COIN gt 4 Oo Using the Scanner Memories 19 a UB355ZH UBC360CLT indd 19 2008 04 08 15 56 04 Bank 10 M Once you fill out the above chart follow these steps to enter or change a frequency in a memory 1 Press E PGM to enter the program mode the scanner turns on the PGM icon 2 If the current channel is not the one you want to program enter the memory number then press HOLD 3 Enter the frequency including the decimal point then press E PGM 4 To program the next memory press A or W and repeat step 3 To program a different memory repeat from step 2 5 To exit program mode press HOLD or SCAN or change the scanner s mode
4. 5 12 162 6000 173 9900 FM 10 13 406 0000 439 9937 FM 6 25 14 440 0000 465 9950 FM 5 15 466 0000 469 9900 FM 10 16 470 0000 512 0000 FM 6 25 17 806 0000 960 0000 FM 12 5 Introduction UB355ZH UBC360CLT indd 7 9 T 2008 04 08 15 55 52 9 Features Channel Memory Scanning Scans frequencies you have stored in any of the channels or banks at a rate of 50 channels per second Memory Availability Store and then scan any of up to 300 channels distributed over 10 banks Direct Channel Access Press 0 9 and HOLD to directly access any stored frequency Channel Lockout Frequency Lockout Skip over stored frequencies channels using the Lockout feature to enable faster scanning Lets you designate up to 50 frequencies each to skip during a search limit or Aircraft to increase the scanning speed Alarm Clock with Snooze provides standard radio broadcasts that you can set as your alarm sound AM FM lets you store up to 30 preset broadcast channels 10 AM and 20 FM for quick access Priority Channel Designate a specific frequency as a Priority Channel Then the radio scans and checks that channel every 2 seconds Select and designate up to 10 frequencies as Priority Channels one per bank Duplicate Channel Alert Lets you know that a selected frequency has already been programmed into memory if you attempt to store it again Limit Frequency Search
5. Delay is turned on by default when you program a memory To turn Delay off or back on first select the channel Then press DELAY The scanner turns on the DELAY icon for memories that have been programmed with delay Using the Scanner Memories a UB355ZH UBC360CLT indd 22 2008 04 08 15 56 05 9 Searching for Active Frequencies Many people enjoy searching for the unknown frequencies that are in use in their area but are not posted to any site or in any publication This scanner radio has two ways to search Limit searching that searches between two set frequencies and Aircraft Band Search Using Limit Search Programming an Upper Lower Limit Follow these steps to program an Upper and Lower limit for the limit search 1 Press SEARCH then HOLD The scanner holds on the current search frequency 2 Enter one of the range limits then press E PGM Press A or W then enter the other range limit and press E PGM Note By press and hold E PGM key it goes to enter the range limit program mode Searching the Selected Range After entering the limits or use the default limits press SEARCH The scanner starts searching from the lower range up to the higher range To change the direction of the search press A or V Using Aircraft Band Search Aircraft Search Operation When MODE switch is moved to Aircraft scanner goes to aircraft search mode In this mode Aircraft Band Search can be
6. Using the Scanner Memories 9 UB355ZH UBC360CLT indd 20 2008 04 08 15 56 04 20 Notes Any frequency you program replaces the previous memory contents f you enter a frequency you have already stored in a different memory in Step 3 the scanner beeps and displays the channel where you have previously stored the frequency If you want to store the frequency anyway press E PGM a second time in Step 3 To clear the contents of a memory enter O in Step 3 Channels you program are automatically unlocked see Locking Unlocking Memories and have Delay turned on See Setting Channel Delay Selecting a Memory To select a single memory to monitor press HOLD The scanner turns on the HOLD icon Then select a memory by pressing A or to go to the memory or input the memory number then press HOLD Scanning Memory Banks To scan the memories you have programmed press SCAN The scanner scans all unlocked programmed memories in enabled memory banks stopping on a memory when it detects a transmission To turn on off memory banks while scanning press the number button that corresponds to the memory bank you want to enable or disable Locking Unlocking Memories You can lock memories so that they are not scanned even if their bank is turned on Simply press L O when the scanner stops on a transmission on the frequency or manually select the memory then press L O The scanner turns o
7. battery low voltage condition In the operating condition with battery power only without AC power an alert tone sounds when the battery needs to be replaced The backup provides backup for the clock when power is off and will power scanning for a short time Auto Power Off turns the scanner off when the battery power gets too low Introduction 9 a UB355ZH UBC360CLT 9 2008 04 08 15 55 52 Controls Scanner e AM RADIO ANT 9 ANT DC IN 12V 9 HEADPHONE 21 20 17 18 19 9990595000909 5599905099950989000050500 999909099999989999999992 0090909090909090909090909090908080 999999999990990999999999399999999 99999990909999399999899999999899 99999903090309999908090999990909 393980393039393039999039393999893 9990969955995 595959590 999009809930399 598099909 000909090009090900090900000 10509090909090900090909090909090900 logo 999 893980399030393039393039899039893 99 209990209090009090009090909090 95909 598099959 909090909090909090909090909090 9 06096909096969095959595959599999090 29509900900 5980009 19595959595959999999999999009999999 9999059995529 999909 09090909090909090909090 599 99909990909990909099809090999999 939803939303930903930399939393939 000009000000090000000909000 50809 0000990900090 090 900090900000909090 0909090900090900000 100
8. indd 2 2008 04 08 15 55 49 WARNING Uniden does not represent this unit to be waterproof To reduce the risk of fire or electrical shock do not expose this unit to rain or moisture Important If you use the supplied AC adapter to power the scanner but have not installed batteries in the scanner never turn the scanner off by disconnecting the AC adapter or unplugging it from the AC outlet This might corrupt the scanner s memory Always use POWER to turn the scanner off before disconnecting AC power Precautions 3 9 UB355ZH UBC360CLT indd 3 2008 04 08 15 55 49 Contents Unpacking Your Scanner 6 INtTFODUCUION iis os ieee anne ee he end RUE elie ete ES Mx 7 Feal les ic cers eles XY ed ce eee GEN 8 CONTOS EE XAR eee whe ee RENE RUE oe Ea he a dn 10 Setting Up The 14 Connecting iioc mas fe x ua DE EE 14 Connecting an Antenna nns 15 Using the Backlight EE 15 Using the Alarm Clock eseseseees een 16 Setting the Current 0000 eee 16 Setting the Alarm cece eren 16 5100 SNOOZE CCP 17 Listening to AM FM Channels 18 Directly Selecting a 18 Using AM FM Memory 0000
9. 0900000009000000090000000900000 10000900000009000000090000000900000 00090 0009590900090900000909000909090 AM FM Aircraft Scanner Backlight 16 15 14 13 12 4 6 5 7 8 9 11 10 Introduction 10 2008 04 08 15 55 54 10 indd UB355ZH UBC360CLT 9 VOLUME Control lets you raise or lower the level of the sound N SQUELCH Control lets you set the signal level required to receive a transmission If you open the squelch all the way you will hear hissing between transmissions This lets you hear weak signals but prevents scanning As you close squelch a stronger signal is required to stop scanning and open audio You normally set the control to a point just where hissing on all channels stops between transmissions SCAN press to begin scanning the channels to resume scanning ALARM Select Set to Off to disable alarm Set to Radio to enable the radio alarm Set to Tone to enable the tone alarm SNOOZE Backlight Backlight Tap to turn the LCD backlight on for 15 seconds Press and hold to permanently turn on the backlight Press and hold again to turn off the backlight Snooze Press while the alarm sounds to silence the alarm for 5 minutes o TIME Set Use to select your desired operation Alarm Set Clock Set Clock HOLD B
10. 50 100 AUTO 160 162 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 162 173 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 406 439 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 440 465 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 466 469 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 470 512 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 806 960 12 5 15 20 25 50 100 AUTO 12 5 KHz 5 12 5 10 12 5 12 5 5 12 5 10 12 5 10 6 25 5 10 6 25 IRR Follow the steps to change the step STEP 1 By pressing STEP in scan hold mode limit search hold mode and aircraft search hold mode go to select step menu STEP Sacre 2 20 77 Ix CJ STEP 2 Press BAND and then press A key to change the band Holding A or W change the band continuously STEP Clune ce n 17433LU 102 Select Step Operation 25 UB355ZH UBC360CLT indd 25 2008 04 08 15 56 06 9 STEP 3 Press STEP and then press A W to change the step and decide it Holding A or W to change the step continuously 5777792 By pressing CLR you can change the step into previous step
11. AND Press HOLD BAND to go to scan hold mode limit search hold mode air band search hold mode radio direct hold mode Press HOLD BAND to resume scanning searching in each hold mode HOLD BAND key is used also for direct channel access Press HOLD BAND to change the band in select step menu EN E PGM Press to enter the Program Mode In Program Mode enter the desired frequency using the numeric keys Then press E PGM to store that frequency into the memory In Limit Search Mode after entering the frequency press E PGM to program the upper and lower limit frequency Note Press and hold E PGM it goes to programming mode for limit frequency 0 to 9 use the numeric keys in four basic operations press a numeric key to enter a frequency press a numeric key to change a channel using the Direct Channel Access feature press a numeric key while scanning to enable or disable the associated scanning bank memory bands 10 POWER Press to turn power on and off The time displays when power is off standby mode 11 CLR this key has three functions press to input a decimal point when you enter a frequency press to cancel a numeric key input O to 9 press to clear an error display Introduction 11 9 UB355Z7H UBC360CLT indd 11 2008 04 08 15 55 54 9 12 SEARCH AM In Scanner mode press to start a Limit Search or to resume searching In AM FM
12. OGRAM and Aircraft Band Search or the step frequency in LIMIT SEARCH and AM FM mode refer to the frequency and step table on page 9 Press and hold for more than 1 second to have the changes run continuously 20 HEADPHONE Jack lets you use an headphone for private listening 21 Antenna Connector connect an external antenna using a BNC connector AM RADIO ANT connector connect the supplied loop antenna and position it for best AM Broadcast radio reception Introduction 9 UB355ZH UBC360CLT indd 12 2008 04 08 15 55 54 LCD 1 2 3 4 12345678910 6 5 STEP HOLD 7 70 90 000 0008 LICI ILI ALARM L O DELAY MEMORY DIREC 9 1011 12 13 14 1 BANK Indicates scan mode and scan hold mode 2 1 10 Indicates scan mode program mode and radio mode In scan mode it indicates select bank Current scanning bank number flashes In radio mode it indicates a radio station channel 3 Batt Flashes when the battery voltage is low Indicates no battery is installed 4 STEP Indicates select step menu 5 SEARCH Indicates limit search hold mode 6 HOLD Indicates scan hold search hold and radio mode direct entry hold 7 PGM Indicates program mode 8 25 Appears when 100Hz and 10Hz digits of the frequency is 25 50 Appears when 100Hz and 10Hz digits of the frequenc
13. Y mode The display shows the initial clock time of 0 00 The scanner remains in STANDBY mode Connecting an Antenna The scanner uses an AM Radio Antenna Jack external loop antenna to Telescopic Antenna Jack receive AM broadcast stations and an external telescopic antenna to receive all other signals Connect the supplied pte Antenna rod antenna by pushing the antenna s connector onto the antenna jack on the back of the scanner and twisting it to the desired angle Connect the two wires from the loop antenna to the AM RADIO ANT terminals on the back of the scanner Carefully remove the tube inserted before using the AM Antenna Jack When the Jack is not in use keep the tube mounted EE AM Loop Antenna You can also use an external antenna not supplied to help to bring in weaker signals Use RG58 50 Ohm lead with a BNC connector to connect the antenna to the scanner Connect and mount the antenna according to the instructions provided with the antenna CAUTION Be sure to follow all safety warnings provided with the antenna Failure to do so could expose you to risk of injury or death and could severely damage the scanner Using the Backlight To turn on the backlight for 15 seconds tap SNOOZE Backlight To turn on the backlight permanently press and hold SNOOZE Backlight for over 2 seconds To turn off the backlight press and hold SNOOZE Backlight again Setting Up The Scanne
14. alarm time move the slide switch to Clock Using the Alarm Clock 9 UB355ZH UBC360CLT indd 16 2008 04 08 15 56 01 9 have the scanner radio alert you at the Backlight selected time slide Off Radio Tone to either SNOOZE Radio or Tone If you set the selector to Radio the alarm will sound with the selected Oft audio source AM FM Scanner or Aircraft If you set the selector to Tone the scanner will sound a tone at the set time To silence the alarm slide Off Radio Tone to Off If you do not turn off the alarm it will sound for 20 minutes then reset to alert you again the following day ALARM Using Snooze t When the alarm sounds press the snooze BAND bar to silence the alarm for 5 minutes Clock Set Clock Off Radio mdp W W Using the Alarm Clock 17 a UB355ZH UBC360CLT indd 17 2008 04 08 15 56 02 9 Listening to AM FM Channels To listen to AM FM channels slide the mode selector to AM FM Then press the button at the top of the scanner to select the desired source AM for AM Broadcast FM1 or FM2 for FM Broadcast Directly Selecting a Channel Press STEP DIR to select the direct entry mode Use the A buttons to step through the selected band The scanner stops on active channels You can also enter the channel frequency using the keypad enter the chan
15. c Antenna uniderr OWNER S MANUAL This Owner s Manual Other Printed Material AM Loop Antenna AC Adapter 3 AA Alkaline Batteries Unpacking Your Scanner 9 UB355ZH UBC360CLT indd 6 2008 04 08 15 55 52 9 Introduction Your scanner radio is a multi featured conventional channel scanner You marine air amateur and other radio services into 300 channels distributed can easily enter and store frequencies for police fire emergency over ten banks Use your scanner to monitor Police and fire departments including rescue and paramedics Business industrial radio Motion picture and press relay Aircraft Auto racing frequencies Utilities Land transportation frequencies such as trucking firms buses taxis tow trucks and railroads Marine and amateur ham radio bands Many more in the 25 88MHz 108 137MHz 137 174MHz 406 512 and 806 960MHz ranges AM FM radio Your scanner can monitor the following bands No Range MHz Mode Default step kHz 1 0 5200 1 7200 AM RADIO 10 2 25 0000 29 9950 FM 5 T 3 30 0000 79 9875 FM 12 5 4 80 0000 82 9900 FM 10 5 83 0000 87 2875 FM 12 5 6 87 3000 107 9000 WFM RADIO 100 7 108 0000 136 9875 AM 12 5 8 137 0000 137 9950 FM 5 9 138 0000 157 9875 FM 12 5 10 158 0000 160 5900 FM 10 11 160 6000 162 5875 FM 12
16. do not use abrasive cleaners or solvents Be careful not to rub the LCD window Do not use excessive amounts of water Birdies All radios can receive birdies undesired signals If your scanner stops during Scan mode and no sound is heard it might be receiving a birdie Birdies are internally generated signals inherent in the electronics of the scanner Press L O to lock out the channel Care and Maintenance a UB355ZH UBC360CLT indd 27 2008 04 08 15 56 06 Technical Specifications Band Coverage Frequency Range Scanner Mode Range MHz 25 0000 to 29 9950 30 0000 to 79 9950 80 0000 to 82 9950 83 0000 to 87 2950 108 0000 to 136 9950 137 0000 to 137 9950 138 0000 to 157 9950 158 0000 to 160 5950 160 6000 to 162 5950 162 6000 to 173 9950 406 0000 to 439 9950 440 0000 to 465 9950 466 0000 to 469 9950 470 0000 to 512 0000 806 0000 to 960 0000 Step Size 5 6 25 8 33 10 12 5 15 20 25 50 100 kHz or AUTO for 800 MHz Band 12 5 15 20 25 50 100 kHz or AUTO Radio Mode UB355ZH UBC360CLT indd 28 0 5200 to 1 7200 87 3000 to 107 9000 15 Bands Default Step 5 kHz 12 5 kHz 10 kHz 12 5 kHz 12 5 kHz 5 kHz 12 5 kHz 10 kHz 12 5 kHz 10 kHz 6 25 kHz 5 kHz 10 kHz 6 25 kHz 12 5 kHz 10 kHz 100 kHz Mode FM FM FM FM AM FM FM FM FM FM FM FM FM FM FM AM WFM Technical Specifications a 2008 04 08 15 56 06
17. e eh 18 Using the Scanner 19 Programming Memories llle eee 19 Selecting a Memory 000 0 eee eee 21 Scanning Memory Banks 21 Locking Unlocking Memories 21 Using Priority cee 22 Setting Channel Delay 22 Searching for Active 23 Using Limit Search liliis 23 Using Aircraft Band 23 Saving a Found Frequency into a Scan Memory 24 Search EOGKOUIS us soper ated eee ee eee 24 Select Step 25 Care and Maintenance 27 General 050 iicet ep lee PEU ue Rue ER Gee Re nate 27 LOCaLtlOlL co REESE AN due Rob e ice ee ac 27 Cleaning seco mecs ense ue eed s 27 DP 27 Contents gt UB355ZH UBC360CLT indd 4 2008 04 08 15 55 49 Technical 28 Declaration of Conformity 30 Contents 5 a UB355ZH UBC360CLT indd 5 2008 04 08 15 55 49 9 Unpacking Your Scanner Please unpack this box carefully and make sure you have Telescopi
18. ing Lets you designate lower and upper frequency range and search within that range for active frequencies You can then store frequencies in memory as channels for later recall Aircraft Band Search Lets you designate the preprogrammed Aircraft Band channels to search Scan and Search Speed Scan Speed 50 channels per second maximum in SCAN MODE Search Speed 50 steps per second maximum in SEARCH MODE TURBO MODE For frequency steps 5kHz apart searching occurs in Turbo Mode which is 150 steps per second Introduction 9 UB355ZH UBC360CLT 8 2008 04 08 15 55 52 9 Clock Display the scanner in standby mode displays the time The clock also features an alarm that can sound up to 20 minutes or be shut off manually A convenient snooze button lets you silence the alarm for an extra 5 minutes Delay you can enable or disable the 2 second delay to resume scanning when a transmission ends Enabling this feature helps prevent missing a response from one of the parties in the transmission LCD Backlight you can enable or disable the LCD back lighted display Key Touch Tone a tone sounds to confirm you have made a valid key input while a different tone sounds to alert you to an invalid entry EEPROM Memory Backup the scanner uses a non volatile EEPROM for memory backup Battery Alert A battery icon alerts you to a no battery installed condition and a
19. l plug into the power jack on the back of the scanner Then plug the Adapter into a standard household outlet that supplies DC Pug AC Adapter 230V AC 50Hz Do not plug the adapter into a switch controlled To Standard outlet Wall Outlet Open the battery compartment and insert 3 AA batteries Be sure to note the polarity markings in the battery compartment You can use either alkaline or rechargeable batteries but the scanner will not recharge batteries in the compartment Use only fresh alkaline AA batteries Rechargeable batteries can be used but battery life is shorter than with alkaline batteries Always remove old weak batteries Batteries can leak chemicals that destroy electronic circuits Do not mix old and new batteries different types of batteries standard alkaline or rechargeable or rechargeable batteries of different capacities Setting Up The Scanner 14 9 UB355ZH UBC360CLT indd 14 2008 04 08 15 55 59 9 Note that the batteries are intended to provide backup power for the clock and for scanning for a short time When the backup batteries becomes too low appears Promptly replace the batteries When you either install batteries or connect the AC Adapter to a standard wall outlet the scanner powers on and goes to STANDB
20. mode press to select the AM memory bank 13 L O FM1 In Scanner mode press to lock or unlock a channel memory in SCAN HOLD or PROGRAM mode In Search mode press to set or clear a selected frequency previously locked out in the LIMIT SEARCH In AM FM mode press to select the FM1 memory bank 14 DELAY FM2 In Scanner mode press to turn the delay option on off In AM FM mode press to select the FM2 memory bank 15 PRI MEM In Scanner mode press to set a Priority channel for Scan Hold mode and Program mode In Program mode press to set the Priority channel setting In SCAN and SCAN HOLD modes press to set Priority Scan on or off In AM FM mode press to select Memory Mode to allow quick channel recall using the 0 9 keys 16 STEP DIR Press STEP DIR in scanner mode to go to select step menu Press STEP DIR to change the step in select step menu Press STEP DIR in radio mode to go to direct entry mode 17 MODE Switch Use to select the desired mode AM FM Aircraft Scanner Slide switch must be set to Clock 18 W Press and release to move down through channel numbers in the following HOLD modes SCAN PROGRAM and Aircraft Band Search or the step frequency in LIMIT SEARCH and AM FM mode refer to the frequency and step table on page 7 Press and hold for more than 1 second to have the changes run continuously 19 A Press and release to move up through channel numbers in the following HOLD modes SCAN PR
21. n the L o icon when it is set to a memory that is locked out To unlock a memory manually select the memory then press L O The scanner turns off the L o icon and includes the memory when scanning its bank To unlock all memories of the bank press and hold L O for 2 seconds the scanner beeps twice and the L o icon disappears Using the Scanner Memories 9 UB355ZH UBC360CLT indd 21 2008 04 08 15 56 04 9 Using Priority Scan You can set one memory in each bank as a priority memory If you turn on the Priority feature the scanner will check the priority memories in enabled banks every 2 seconds even if it has stopped on a transmission on another memory To set the memory in a bank to be the priority memory manually select the memory then while holding on the memory press E PGM to put the scanner in program mode and press PRI The scanner turns on the icon when it is stopped on a memory designated as priority To turn on Priority Scan press PRI while the scanner is scanning or holding on a memory but not in program mode You will notice a short break in audio every 2 seconds as the scanner checks the enabled priority memories If there is a transmission on a priority memory the scanner will immediately tune to that memory Setting Channel Delay You can set the scanner to pause for 2 seconds at the end of a transmission on a memory This is useful to help prevent missed replies
22. ndd 30 2008 04 08 15 56 07 Memo UB355ZH UBC360CLT indd 31 a 31 2008 04 08 15 56 07 THANK YOU FOR BUYING A UNIDEN PRODUCT A World Without Wires Liniden 2008 Uniden Corporation Printed in China UBZZ01355ZZ 0 a UB355ZH UBC360CLT indd 32 2008 04 08 15 56 13
23. nel frequency for FM or AM and press E Using AM FM Memory Your scanner has 30 AM FM memories for quick channel recall To store a channel into memory first select the band AM FM1 or FM2 Then directly select the channel you want to store see above While listening to the channel press and hold the number button that corresponds to the memory you want to save the channel into for 2 seconds The scanner switches to the Memory mode for the current band w SS w AM FM Aircraft Scanner wis BAND motn scan iLAY STEP M2 MEM DIR LO DELAY PRI STEP FM1 FM2 MEM DIR AM FM Aircraft Scanner p BUE To quickly recall a channel select the band select the channel memory mode by pressing PRI MEM then tap the number button that corresponds to the memory where the channel is stored Listening to AM FM Channels 18 a UB355ZH UBC360CLT indd 18 2008 04 08 15 56 03 9 Using the Scanner Memories Your scanner has 300 memories you can store s frequencies into for scanning The memories eS ee are arranged in 10 banks of 30 memories each BLEU While scanning you can quickly select which MODE bank to scan by pressing the number button that corresponds to the bank you want to turn Ew on or off for scanning To select the scanner BAND mode
24. operated Searching starts initially when MODE switch is moved to aircraft Searching stops at a frequency when transmission is found Searching resumes automatically after the transmission ends Press SEARCH or A V to start aircraft search when search stops at a frequency Search direction can be changed by A Searching for Active Frequencies 23 9 UB355ZH UBC360CLT indd 23 2008 04 08 15 56 05 9 The scanner keeps receiving the current frequency in aircraft search hold mode regardless of existence of transmissions However if there is no transmission the speaker is muted By pressing HOLD in aircraft search mode searching stops and the scanner goes to aircraft search hold mode In this mode pressing W changes search direction to downward and pressing A changes search direction to upward As the another function of and A in this mode pressing can decrement the frequency 1 step and pressing A can increment the frequency 1 step Holding or A to decrement increment the frequency continuously By pressing HOLD or SEARCH key to go to aircraft search Saving a Found Frequency into a Scan Memory When the scanner stops on the frequency you want to save press HOLD to hold on that frequency Then press E PGM The scanner displays the lowest numbered empty memory or the last scanned memory if all memories are used Use A F to select the memory to hold the frequency then pres
25. r 15 9 UB355ZH UBC360CLT indd 15 2008 04 08 15 56 00 9 Using the Alarm Clock Your scanner s Clock displays whenever you turn off the radio functions It can also be used as a standard alarm clock Setting the Current Time Follow the steps to set the current time Backlight 1 Move the slide switch to Clock Set E SNOOZE The hour digits flash Alarm Set Clock Set Clock Off 2 Press A or to change the hour by one 18 hour increments decrements or press the number keys to select the present hour Then press E PGM to set the hour The minutes digits flash Co Press A or W to change the minute setting by one minute or press the appropriate number keys to enter the minutes Then move TIME slide switch to Clock position Note When minute is changed second is reset to O Setting the Alarm Clock Follow these steps to set the alarm time 1 Move the slide switch to Alarm Set Backlight The hours digits flash E SNOOZE 2 Press A or W to change the hour by one Alarm Set_ Clock Set Clock Off hour increments decrements or press the Jaa number keys to select the present hour PAL 1 Then press E PGM to set the hour The TIME minutes digits flash Co Press A or V to change the minute setting by one minute or press the appropriate number keys to enter the minutes Press E PGM to set the minutes 4 To lock in the
26. s E PGM to store the frequency into the memory Search Lockouts If the scanner stops on a frequency that you don t want to hear you can lock it out When locked out the scanner won t stop on the frequency in either Limit Search or Aircraft Band Search Simply press L O when the scanner stops on the frequency to lock the frequency out To unlock the frequency during search press HOLD Then manually step to the frequency using the A W keys When you have selected the frequency press L O Notes Up to 50 frequencies can be skipped for limit search Up to 50 frequencies can be skipped for Aircraft Band search Searching for Active Frequencies 9 UB355ZH UBC360CLT indd 24 2008 04 08 15 56 05 9 Select Step Operation The user can change the steps of each band in select step menu when MODE switch is moved to Aircraft or Scanner Follows are optional band and step 25 29 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 30 79 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 80 82 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 83 87 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 108 136 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 137 138 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 138 157 5 6 25 8 33 10 12 5 15 20 25 50 100 AUTO 158 160 5 6 25 8 33 10 12 5 15 20 25
27. that goes to step menu STEP 4 Press ENT to go to previous mode Or wait for 5 seconds to return to the mode you were in Press SCAN to go to scan mode Press SEARCH to go to search mode Move the MODE slide switch to Aircraft to go to Aircraft Hold mode Move the MODE slide switch to AM FM to go to AM FM radio mode Notes The all lockout frequencies of the band automatically can be unlocked when the step is changed at the Band The frequency can be programmed by 5kHz step even though the step is set up to 15kHz or 20kHz Select Step Operation 9 UB355ZH UBC360CLT indd 26 2008 04 08 15 56 06 Care and Maintenance General Use Turn the scanner off before disconnecting the power If memory is lost simply reprogram each channel Always press each button firmly until you hear the entry tone for that key entry Location Do not use the scanner in high moisture environments such as the kitchen or bathroom Avoid placing the unit in direct sunlight or near heating elements or vents f the scanner receives strong interference or electrical noise move it or its antenna away from the source of the noise If possible a higher elevation might provide better reception Also try changing the height or angle of the antenna Cleaning Disconnect the power to the unit before cleaning Clean the outside of the scanner with a mild detergent To prevent scratches
28. y is 50 75 Appears when 100Hz and 10Hz digits of the frequency is 75 9 ALARM Indicates ALARM is enabled Flashes while ALARM is being activated or snoozing 10 L o Indicates locked out channel and at search skip frequency 11 12 Indicates the designated Priority channel 12 DELAY Indicates delay is on 13 MEMORY Indicates radio mode memory mode 14 DIRECT Indicates radio mode direct entry hold mode Notes The backlight turns off automatically after 15 seconds from the last key stroke if not permanently turned on The scanner sounds special tones as follows to confirm key entry to indicate an error in key entry to indicate low battery voltage Introduction 13 9 UB355ZH UBC360CLT indd 13 2008 04 08 15 55 57 9 Setting Up The Scanner These guidelines will help you install and use your new scanner f your scanner receives interference or electrical noise move the scanner or its antenna away from the source You might also try changing the height or angle of the antennas Use an optional mono earphone or mono headset with proper impedance for private listening Do not use the scanner in high moisture environments such as in the kitchen or bathroom Avoid placing the scanner in direct sunlight or near heating elements or vents Connecting Power e Insert the supplied AC Adapter s barre