Home
BI-LD016 LED Three-Claw Fish
Contents
1. 5 T r Y um Y T m gm qm T qm umm T L4 P en n c a eS 3 5S jr qe p pe qe pe pe qe qj 04 04 04 094 Cua cn 7 1 le p ke v br pb pe le C zx ja joo jon 4 co c3 64 en S Loto jm joo jo ly es O le Neo I eg pr foo Ss Ju 5 en A Dip Switch position
2. BI LD016 Instruction Manual WARNING FOR YOUR OWN SAFETY PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START UP The manufacturer will not accept liability for any resulting damages caused by the non observance of this manual or any unauthorized modification to the equipment Never let the power cable come into contact with other cables Handle the power cable and all mains voltage connections with particular caution Never remove warning or informative labels from the equipment Do not open the equipment and do not modify the equipment Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment 15 not in use or before cleaning Only handle the power cable by the plug Never pull out the plug by pulling the power cable Make sure that the available voltage is between 110v 240v Make sure that the power cable is never crimped or damaged Check the equipment and the power cable periodically If the equipment is dropped or damaged disconnect the mains power supply immediately Have a qualified engineer inspect the equipment before operating again If the equipment has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediatel
3. chasing until the power is turned OFF or the mode is changed Sound Active Mode To select sound active mode set dipswitch 9 to ON You can now use the sensitivity control on the back panel to set the required sound input level With no music present the LEDs will turn OFF and will come back ON as soon as the music starts again Slave Mode To select the slave mode set dipswitch 9 to OFF and others to ON The slave units will now follow in conjunction with the master unit Note The master unit can be run in any mode for the slave units to follow Overview _ Features 1 1 Hanging bracket 2 DMX in 3 DMX out 4 Dipswitches 5 Power Out 6 Power In 7 Mirophone 8 Sound sensitivity control 9 9 Fuse 10 Cooling fan DMX Function Chart 0 251 Pattern selector 1 to 15 bottom right mirror 252 255 Blackout bottom right mirror 0 251 Pattern selector 1 to 15 bottom left mirror 252 255 Blackout bottom left mirror 8 o 0 255 opeed control 7 0 251 Pattern selector 1 to 15 top mirror 252 255 Blackout top mirror DMX Set up DMX 512 DMX Digital Multiplex is a universal protocol used as a form of communication between intelligent fixtures and controllers ADMX controller sends DMX data instructions form the controller to the fixture DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures m
4. ost controllers only have a data out terminal DATA Cable DMX cable requirements for DMX operation The TriScan can be controlled via DMX 512 protocol The DMX address is set on the back of the unit Your unit and your DMX controller require a standard 3 pin XLR connector for data input output figure 1 Figure 1 Further DMX cables can be purchased From all good sound and lighting suppliers or Prolight dealers Please quote CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split DMX Set up Notice Be sure to follow figures 2 amp 3 when making your own cables Do not connect the cable s shield conductor to the ground plug or allow the shield conductor to come in contact with the XLR s outer casing Grounding the shield could cause a short circuit and malfunctions common DMX 512 out 3 pin XLR DMX 512 in 3 pin XLR XLR MALE SOCKET XLR FEMALE SOCKET i XLR Pin Configuration 2 cold 1 ground 1 ground 2 cold Pin 1 Ground Ip Pin 2 Negative 3Hot 3Hot Pin 3 Postive FIGURE 3 FIGURE 2 Special Note Line termination When longer runs of cable are used you may need to use a terminator on the last unit to avoid erratic behaviour Termination reduces signal transmission problems and interferance it is always advisable to connect a 9 DMX terminal resistance 120 Ohm 1 4 W between pin 2 DMX and
5. pin DMX of the last fixture Using a cable will reduce the possibilities of malfunctions 5 Pin XLR DMX Connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 Pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The Chart below details the correct cable conversion 3 Pin XLR to 5 PIN XLR Conversion Conductor 3 Pin XLR out 5 Pin XLR in Ground shield Pin 1 Pin 1 Negative Pin 2 Pin 2 Positive Pin 3 Pin 3 pen O O A m Q Switch Quick Reference Chart Dip Switch Position DMX Di DMX DIP SWITCH 472 303 6 2 2 x 5 s OF 37s 405 437 aeo 57 i E 0 al CX C04 04 TRS PON 04 04 04 064 094 04 C04 04 PESOS 094 POND 094 09 EERRREERRRRRRE SERERE SERE ER m ge 3 285 3 C O4 EE e arr s uns ur 0s 5 DMX Address a 306 335 370 402 434 466 5 2 F oa 241 2 EIER 256 328 360 302 424 255 488 192 q a qm qu q q qm qme qu q q q qm q q qm q q q q q qm q area es Je fst fst 1 jus fii us jus fin Jin u ju 1
6. y The arising condensation might damage the equipment Leave the equipment switched off until it has reached room temperature f your product fails to function correctly discontinue use immediately Pack the unit securely preferably in the original packing material and return it to your Prolight dealer for service Only use fuses of same type and rating Repairs servicing and power connection must only be carried out by a qualified technician THIS UNIT CONTAINS NO USER SERVICEABLE PARTS WARRANTY One year from date of purchase CAUTION TAKE CARE USING THIS EQUIPMENT HIGH VOLTAGE RISK OF ELECTRIC SHOCK Technical specifications You should find inside the carton the following items 1 BI LDO16 2 Power cable 3 Instruction manual Technical Specifications DMX channels 8 Voltage AC 110 125V 50 60Hz 72 Ultra bright LED s R 24 G 24 B 24 Fuse 1 Amp Power Consumption 20W Operations There are 4 operating modes to choose from 1 DMX mode 2 Auto Run mode 3 Sound active mode 4 Slave mode DMX Mode To select DMX mode set dipswitch 10 to ON You can now set the required DMX address using dipswitches 1 to 9 The start address for this fixture is O Please refer to the chart below for DMX functions Auto Run Function Mode To select auto pattern mode set all dipswitches to the OFF position The unit will now cycle through all it s built in patterns In this mode the LEDs will remain constantly