1. and appropriate protection devices must be incorporated into the system as required by federal state and local laws 33 Z se 2 Green oa Pr A premium efficiency motor in the Centurion motor family Disclaimer The information in this document incorporates proprietary rights and IS not to be duplicated wholly or in part without the express written permission of Regal Beloit EPC Inc Copyright 2010 The text and images in this document are not to be modified without express written permission of Regal Beloit EPC Inc This document as a whole may be reproduced and distributed but not sold for educational purposes This document as a whole may be included in the bulk of other education material that is for sale with express written permission of Regal Beloit EPC Inc 34 century Distribution Services 1325 Heil Quaker Blvd LaVergne TN 37086 Phone 866 887 5216 Fax 800 468 2062 www pool motors com 2508142 005 Rev C 11 10 11 Century Formerly A O Smith Electrical Products Company A Regal Beloit Company S FF H G BELOIT Copyright O 2011 Regal Beloit Corporation
2. contrast increases or decreases by five increments at a time e Press ENTER to save the settings and return to the Main screen 8 century 7 a LS Q 2 Green mium efficiency motor in th il 0 sn a A pre e Centurion motor family 3 4 Set the System Clock Time The current system time displays in the upper left hand corner of the LCD display Adjust the system clock time to match the current time Follow these steps to set the time The system time and the actual time must match for the timers to work correctly Note The user must manually adjust the time to accommodate regional time zones and daylight savings Check the system clock time after Power ON 1 On the main screen press CHANGE G SETTINGS Century 2 Press CHANGE CLOCK Power century 9 3 Press YES to change the clock setting or NO to return to the main screen without changing the time DO YOU WANT TO CHANGE THE CLOC 4 Press HOUR or MINUTE Power Q re 10 century 5 Press and hold or to set the time Press SN CT ENTER to save the settings Press ENTER when the hour and minutes are set to return to the main screen 1210 PM The main screen displays the new time Power G nturys century 11 50 2ZGreen 3 5 Set High Speed Maximum Time Limit The maximum time limit for High Speed is 24 hours The default time limit is 12 hours Follow these steps to change t
3. not potential injury to personnel NOTICE century Table of Contents 1 0 2Green Specifications ss 1 1 1 gt OC 110 9 EE cies ai E E E EE EEEN ES 1 1 2 gt 61516 612 11 6 d eo eo a 2 1 2 1 Electrical Specifications rrrnrnnnnrrnnnrnvrnnnnrvnnrrrnnnrrnrnnnennnnnnen 2 122 SPECIAL NOCES hs dard case romane 3 2 0 2Green Features 4 2 1 TROP MOTE ea ee ae ne ae ha mien 4 2 2 Manual Mode errernnnornnnornnnnnnnnnvnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnennnnennunere 4 3 0 2Green Operation iii 5 3 1 Screen LA OUT 5 3 2 MAINS Cl EEE 6 3 3 Set the Display Contrast 7 3 4 Set the System Clock Time 9 3 9 Set High Speed Maximum Time Limit 12 3 5 1 Maximum High Speed Error Messages 14 3 6 Timer Mode Settings 15 3 6 1 Set High Speed Timer 15 3 6 2 Set Low Speed Timer rrrnnnnnnnnnnannnnnnrnnnnrnnnnnnvnnnrnnnnrnnnnennanennnne 19 3 7 Change the Timer Mode Settings 20 3 8 Manual Mode Settings cccccccsseeecesseeeseseeecesseesesseeseesenens 21 3 9 2Green Fault Log Error Codes 30 DENE re 34 century 1 0 2Green Specifications 1 1 Introduction The 2Green s integrated electronics control the power supply to the motor The interface controls the Start and Stop time of the two speed
4. 2Green A premium efficiency motor in the Centurion motor family TIMER INTERFACE USER MANUAL Premium Efficiency Two Speed Motor with Integrated Timer Green Choice Eco Friendly Electric Motors Century Formerly A O Smith Electrical Products Company A Regal Beloit Company Z se 2 Green oa Pr A premium efficiency motor in the Centurion motor family COPYRIGHT Copyright 2011 Regal Beloit EPC Inc Tipp City Ohio All rights reserved by Regal Beloit EPC Inc TRADEMARKS All trademarks and registered trademarks are the property of their respective companies The information in this document incorporates proprietary rights and is not to be duplicated wholly or in part without the express written permission of Regal Beloit EPC Inc REVISION C November 2011 2508142 005 century pb 2Green A premium efficiency motor ii enturion motor family SAFETY Safety is emphasized throughout the user manual Obey all safety messages that follow these symbols to avoid possible injury or death and or damage to the equipment WARNING the safety alert symbol alerts you to potential personal injury hazards Obey all safety messages that follow this symbol to avoid injury or death CAUTION identifies potential equipment damage or failure conditions It also alerts personnel to potentially dangerous situations NOTICE identifies potential equipment damage or failure conditions but
5. 9 Z a Q 2 Green D A premium efficiency motor in the Centurion motor family 3 7 Change the Timer Mode Settings The timer mode settings can be changed when necessary The timer settings can be adjusted even when the motor is ON The changed set tings become effective immediately Follow the steps in this section to change the timer mode settings 1 Press CHANGE TIMERS at the main Power G screen Century HIGH SPEED REMAINING TIME DHOURS 4 MINUTES 2 Press YES to reset the timers or press Power O NO to return to the Century main screen If the user presses Yes the motor turns RESET MOTOR TIMERS 7 OFF The current HIGH SPEED SET FROM I I 12 00 FM gt 100 P i setting IS erased LOW SPEED SET FROM from memory 1 00 ding PM A Follow the steps in section 3 6 1 to reset the times century 20 3 8 Manual Mode Settings The Manual mode turns the motor ON or OFF in either the High Speed or Low Speed mode immediatley for specific period duration as defined by the user The Manual mode is set in one hour increments Each Manual interval overrides the Timer mode settings The Timer mode settings reactivate after the Manual mode is completed Manual mode Features e The motor can be turned ON or OFF for a minimum of one hour in either the Low Speed or High Speed modes e The maximum time a motor can be operated in Manual High Speed mode is 24 Hrs e The mot
6. WMT LASSEN fai D MOURS Screens continued on next page 28 century Error message screens continued Low Speed Error Messages Power Century KOTDR OFF HiHi LCA GREED Ab THE CARNOT EE LESS I FR Century BLARLEL LO SPEED On TAF WAT CoM PSP PT century Power Century TL Orr MEHL LO BREED Ob Fae SAT BE LESS Century br k Li LO SPEED OFF TRE LAIT CAT CLSC Z a Q 2 Green D T T A premium efficiency motor in the Centurion motor family 3 9 2Green Fault Log Error Codes Electronic malfunctions may cause error codes to flash on the screen When this happens the timer is disabled The user must recycle the power The 2Green stores the last ten faults in a log To view the log follow these steps 1 Press CHANGE SETTINGS at the Power G main screen CET 2 Press MORE MENU Power 30 century 3 Press FAULT LOG Power G nturye 4 Press UP or DOWN to scroll Power O through the log Century The following screen shows that Fault 09 occurred on the 12th day at EE en 13 hours and 31 7B MEID OOH DEM minutes Press HOME to return to the main screen century 31 7 a 2 Green me aA A premium efficiency motor in the Centurion motor family This page shows three fault screens that may appear Os G ntury CE 32 century 7 a Q 2Green A pr
7. ation Lo Speed High Speed e The center rows show user defined settings e The three data entry keys are the bottom row The user presses the appropriate key and enters or changes timer data In the following illustration the system time is 12 18 PM the motor status is High Speed On and the High Speed Remaining time is 42 minutes Power G ntury C Power LED C Current system time HIGH SPEED and motor status REMAINING Tire HOURS 43 MRUTES CHANGE CHANGE MANUAL C D User defined settings TIMERS SETINGS Data Entry keys century 5 Z Q 2 Green D Gp oe A premium efficiency motor in the Centurion motor family 3 2 Main Screen The system functions are set on the main screen Power G nturys Set the following functions on the Main Screen e High Speed and Low Speed timers e System settings e High Speed and Low Speed timers in Manual mode 6 century 7 a LS Q 2 Green AA N T T Z PA A premium efficiency motor in th il e Centurion motor family 3 3 Set the Display Contrast Adjust the display contrast to improve visibility in various lighting conditions Follow these steps to set the contrast 1 Press CHANGE SETTINGS G century 2 Press CHANGE CONTRAST Power G century century 7 3 Press the or to increase or decrease Power O the display contrast Century e Hold a button down for three seconds and the
8. emium efficiency motor in the Centurion motor family This table shows the Faults Error Codes that may occur and the steps the user must take to remedy the situation Fault Name ee Message Display Remarks Course action to reset the Fault RAM Fault Remove power or call Wait for minimum 15 sec and service person then take necessary action REGISTER Fault 04 Remove power or call Wait for minimum 15 sec and service person then take necessary action CLOCK Fault 05 Remove power or call Wait for minimum 15 sec and service person then take necessary action ADC STUCK Remove power or call Wait for minimum 15 sec and Fault service person then take necessary action OVERCURRENT Remove power and Wait for maximum 1hr and take Fault rotate shaft necessary action It is due to the locking of shaft EEPROM Fault Remove power or call Wait for minimum 15 sec and service person then take necessary action EEPROM Remove power or call Wait for minimum 15 sec and CONFIGURATION service person then take necessary action Fault RTC Fault 10 Remove power or call Wait for minimum 15 sec and service person then take necessary action KEYPAD Fault Remove power or call Wait for minimum 15 sec and service person then take necessary action OVERLOAD Fault Remove power and Wait for maximum 1 hr and take check impeller size necessary action It is due to over load of motor The 2Green is not a primary protection device Additional
9. er Time Press ENTER to store the High Speed start time 4 The High Speed stop time displays Press or to change the vo CT High Speed stop time or press ENTER to accept the times 200 PM HIGH SPEED START TIME 3 00 FM HIGH SPEED STOP TIME ENTER A N 16 century If the High Speed ON duration exceeds the High Speed Maximum Limit an error message appears 5 Ifthe High Speed ON duration does exceed the Maximum limit the High Speed default time screen appears after the error message flash Press Enter century Power CT MOTOR OFF HIGH SPEED TIME LIMIT CANT CROSS 12 HOURS GOTO CHANGE SETTINGS Power CT 12 00 PM HIGH SPEED START TIME 12500 AM 17 6 The user is asked to set the LOW SPEED timer Press NO 7 The SAVE TIMER SETTINGS screen appears Press HI SPEED MAX TIME SAVE TIMER SETTINGS 7 HIGH SPEED SET FROM 1300 PM 1 00 Fw LOW SPEED IS NOT SET CHANGE SAVE Hi SPEED TIMES Follow the steps in section 3 6 to set the HI SPEED MAX TIME Follow the steps in section 3 7 to set the timers again 18 century 3 6 2 Set Low Speed Timer Follow the steps in section 3 6 2 to set the Low Speed The motor oper ates at the times set by the user The main screen appears and shows the High and Low Speed remaining times depending on whether the current speed is high or low P i Cr CT JT AM JE AM Low Sit Stor TM Century century 1
10. he limit 1 On the main screen press CHANGE Power O SETTINGS Century 2 Press MORE MENU j de Century 12 century 3 Press HIGH SPEED MAX TIME Power G B 4 Press the or to increase or Power O decrease the High Century Speed maximum time Press ENTER to return to the main screen century 13 Z a Q 2 Green D T A premium efficiency motor in the Centurion motor family 3 5 1 Maximum High Speed Error Messages The maximum High Speed Time limit is 24 hours and the minimum is one hour If a time limit is set too high or too low more than 24 hours and less than one hour error messages flash on the screen for 10 seconds Reset the time limits Power G ntury MAX HIGH SPEED TIME LIMIT CANNOT EXCEED A HOURS Power G nturye MINIMUM HIGH SPEED TIME UMT CANNOT BE 14 century 7 a LS Q 2 Green ANA T T T ee A premium efficiency motor in th rion mote i e Centu 3 6 Timer Mode Settings The Timer mode settings determine the everyday High Speed and Low Speed run time Follow these steps to set the timers after first power ON 3 6 1 Set High Speed Timer 1 Press SET TIMERS at the main screen G CT 2 Press YES to set the High Speed timer If No is selected the Low Speed timer settings screen appears SET HIGH SPEED TIMER century 15 3 Press or to set the High Speed Start O Pow
11. leave the Manual mode and return to Timer mode press Resume Timers 7 Press Yes to resume Timer mode CE To engage Setting 2 Power PR 1 Press HIGH SPEED Century OFF at the High Speed On screen to engage Option 1 2 Press LOW SPEED ON at the High Speed On screen to engage Option 2 century 25 3 To leave the Manual mode and return to G ntury Timer mode press Resume Timers 4 Press Yes to resume Timer mode Power Century To engage Setting 3 Power G nturys 1 Press HIGH SPEED ON at the Low Speed On screen to engage Option 1 2 Press LOW SPEED OFF at the Low Speed On screen to engage Option 2 26 century 3 To leave the Manual mode and return to Power G y Timer mode press Century Resume Timers 4 Press Yes to resume Timer mode century 27 2 Green SS ee A premium efficiency motor in the Centurion motor family The Manual mode duration limit is a maximum 24 hours and minimum 1 hour If the user attempts to set the times higher or lower than the defined limits error messages such as those shown on the following eight screens flash for 10 seconds The user can exit before 10 seconds by pressing any key High Speed Error Messages Century CE MOTOR DET EF pe MOTOR DEF RAPA bie SFR GH TIME CAMHOT BE LESS MAMJAL HiHi SPEED OFF TRE CARROT BE LESS BT CFF INA Aa TL OFF AL TO SPL Lr I Pe UT CANNOT EXCERT MANUAL LO SEED DEF TP
12. mode duration or Low Speed mode duration is set in increments of 30 minutes e Speed times cannot be set to overlap e The default maximum duration for which the timer High Speed mode can be set is 12 Hours The maximum high speed time limit can be adjusted in Change Settings on the screen menu e The Low Speed mode can be set for a maximum ON duration of 24 hours 2 2 Manual Mode In Manual mode the electronics start and stop the motor in high or low speed for a period of time specified by the user The duration is set in multiples of one hour The Manual mode of operation overrides the Timer mode of operation In Manual mode the user selects how long the motor will operate in High Speed or Low Speed The 2Green returns to the Timer mode of operation after the Manual mode operation ends The motor can oper ate in either High Speed manual or Low Speed manual for a maximum of 24 hours Only one mode can be activated at a time Select the time period for which the motor operates in either High Speed manual or Low Speed manual mode ON or OFF 4 century 3 0 2Green Operation 3 1 Screen Layout The power LED on the front face of the timer indicates when the motor is powered ON The user enters settings on the three data entry keys at the bottom of the display screen The 2Green display screen is divided into three parts e The top row displays the current system time and the status of the motor ON OFF or active mode of oper
13. or cannot be simultaneously operated in both Low Speed and High Speed modes e The motor responds within five seconds after the user presses Enter The Manual Mode has three current Motor Status settings Each setting has two options Setting Current Manual Manual Motor Status Operation Option 1 Operation Option 2 Motor Off High Speed On Low Speed On High Speed On High Speed Off Low Speed On Low Speed On High Speed On Low Speed Off AEE Pol Century 21 A 7 a N 2 Green AA N T T A premium efficiency motor in the Centurion motor family Enter the Manual mode from any of these three screens Motor Off Power G ntury High Speed On Low Speed On Olde G ntury 22 century To engage Setting 1 1 Press MANUAL on the main screen 2 Press HIGH SPEED ON to engage Option 1 century Power G nturys OUT G nturys TIMERS 23 3 Press or to increase or decrease the High Speed ON duration Press ENTER to save the settings The motor turns on in High Speed and runs for the time duration you set 4 The main screen shows the remaining time 0 HIGH SPEED ON MANUAL HIGH SPEED REMAINING TIME 1 HOUR O MINUTES 24 century a LS Q 2 Green mium efficiency motor in th il gp a A pre e Centurion motor family 5 Press LOW SPEED ON to engage Pa F Option 2 orm Repeat step 3 6 To
14. residential in ground pool pumps rated greater than 1HP have at least two speeds The low speed must be the default circulation speed The high speed operates only temporarily or intermittently This speed variation reduces the pump s electrical consumption by calculating its volume pressure and power based on the change in revolutions per minute rpm or the change in the impeller diameter The 2Green meets all California legal requirements NOTICE When using two speed pumps manufactured on or after January 1 2008 the pump s default circulation speed MUST be set to the LOW EST SPEED high speed override can be set for a temporary period not to exceed one normal cycle or two hours whichever is less California Title 20 Compliance for Pool Pumps The built in electronics control only one line input to the motor The system power must be disconnected prior to installing servicing to avoid the risk of electrical shock Failure to do so can result in electrocution or personal injury such as shock or burns or damage to the equipment P Century 3 7 e 2 Green oa Ste A premium efficiency motor in the Centurion motor family 2 0 2Green Features 2 1 Timer Mode The Timer mode operates the motor in High or Low speed during each 24 hour period Once set the start and stop times are the same for each day Timer mode features include e The motor operates in either High Speed or Low Speed e The High Speed
15. single phase induction PSC motors The motors are rated up to 230V AC at 3 45 HP or 115V AC at 1 26 HP The 2Green offers the Timer mode and Manual mode You can set either High Speed or Low Speed in both modes You can set the timer to power ON and OFF at specific times Only one mode can be activated at a time It takes the timer only two seconds to turn the motor on in both modes for high speed and low speed The 2Green offers the following e Wide LCD display with contrast adjustment e User friendly interactive screens e Timer mode eliminates need for frequent user adjustment e Settings are protected in case of power failure e Low power standby mode e LCD backlight turns off after 30 seconds of inactivity e Power ON LED indication e Timer recognizes an overcurrent condition and protects the electronics century 1 7 2 Green Pr A premium efficiency motor in the Centurion motor family 1 2 Specifications 1 2 1 Electrical Specifications Electrical Ratings RS EE 230VAC 3 45 HP maximum or 115VAC 1 26 HP maximum Real Time Clock Accuracy 5 4 sec month time drift Power Consumption Less than 3 watts Insulation Class Agency approval UL and CUL UL 60730 1A Ace Application and Environment Ambient Conditions Se 20 to 85 degree Celsius Operating 0 to 50 degree Celsius Humidity 95 Relative Humidity 1 2 2 Special Notices NOTICE The state of California requires that all