Quick start guide
Contents
1. BiPAP AVAPS Quick start guide e Set up device e Front panel overview e Start therapy e Stop therapy e View information e Comfort settings e Undocking the humidifier e Humidification PHILIPS S RESPIRONICS sense and simplicity Set up device To access provider mode 1 From the main menu highlight e Setup 2 Press and hold ramp button and control wheel simultaneously for 4 5 seconds until beep 3 Provider Setup screen then appears You will remain in provider mode until you exit the Setup screen using the lt Back selection or until a screen time out occurs after one minute To program device 1 Turn control wheel to specific setting and press 2 Turn control wheel to desired option and press control CPAP S T wheel to select v 3 Turn control wheel to next setting and repeat 4 To exit turn control wheel to lt Back and press Provider setup menu Therapy settings pap Mode CPAP S S T T PC AVAPS AVAPS On Off V Vte 200 1500 ml IPAP IPAP max 4 25 cmH7O IPAP v IPAP min 4 25 cmH7O IPAP IPAP 4 25 cmH7O EPAP EPAP 4 to IPAP BPM BPM 0 30 Ti Ti 0 5 3 0 sec Comfort settings FLEXa Flex control 1 On o Off FLEX Flex setting D Off 1 2 3 Ta Rise time control 2 On 2 Off va Rise time 1 3 1 200 ms 2 300 ms 3 400 ms a Ramp 0 45 min Ramp start 4 to EPAP Provider setup menu cont Alarm settings HA Apnea SBA Patient disconnec
2. am below Hold entire unit at each end and slide release latch to the right Humidifier bottom view Release latch Humidification R With device turned off remove and fill chamber with water 1 a Lift humidifier door until it locks in place Do not force CJ door higher than the locked position b Grasp front of chamber and slide toward you i m 2 a Gently push tab located inside round opening on top a of chamber b Separate top and bottom of chamber VN 3 Fill bottom chamber with distilled water al 4 Observe maximum fill lines located on sides of chamber K bs 5 Do not overfill C N Y Reassemble the chamber by placing the hinges on lid over the Pa two tabs on back of chamber Close lid until it locks in place _ eo with an audible click Insert filled chamber into humidifier Philips Healthcare is part of Royal Philips Electronics How to reach us www philips com healthcare healthcare philips com Asia 49 7031 463 2254 Europe Middle East Africa 49 7031 463 2254 Latin America 55 11 2125 0744 North America 1 425 487 7000 800 285 5585 toll free US only Philips Respironics 1010 Murry Ridge Lane Murrysville PA 15668 Customer Service 1 724 387 4000 800 345 6443 toll free US only Philips Respironics International Headquarters 33 1 47 28 30 82 Philips Respironics Asia Pacific 65 6882 5282 Philips Respironics Australia 61 2 9666 4444 Phili
3. ghout the night even if room temperature changes Start therapy l 1 From the main menu turn the control wheel to C om C Therapy and press 2 The monitor screen will be displayed and the device Note You can select the measured parameter to display on the monitor screen Choose from i Leak RR MinVent or Vre S T 4 0 cmH20 1 lt 21 I min In provider mode gf simultaneously pressing the alarm silence button Xx and the ramp button lt lt for a few seconds gives 4 0 21 Al access to the full monitoring screen allowing all parameters to be viewed at once To get back to the monitor screen push the 400 10 95 control wheel Stop therapy eh AVAPS While the monitor screen is displayed press the control wheel S T for a few seconds and the device will stop 4 0 cmH20 1 lt 21 l min View information 1 Turn the control wheel to Info and press 2 Turn the control wheel to desired option to view the information g 3 To exit out turn the control wheel to lt Back and press Comfort settings 1 From the patient screen highlight T Comfort The Flex FLEX Ramp start t and Rise Time 7 comfort features will be shown in this menu selection if enabled 2 Turn wheel to specific setting and press 3 Turn control wheel to desired option and press to select 4 To exit turn control wheel to lt Back and press Undocking the humidifier Refer to diagr
4. ps Respironics China 86 021 24127311 Philips Respironics Deutschland 49 8152 93 060 Philips Respironics France 33 2 51 89 36 00 Philips Respironics Italy 39 039 203 1 Philips Respironics Sweden 46 8 120 45 900 Philips Respironics Switzerland 41 6 27 45 17 50 Philips Respironics United Kingdom 44 800 1300 845 www philips com respironics Respironics BiPAP and AVAPS are trademarks of Respironics Inc and its affiliates All rights reserved Please visit www philips com respironics 2010 Koninklijke Philips Electronics N V All rights are reserved PHILIPS Philips Healthcare reserves the right to make changes in specifications and or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication Broudy AE 10 15 10 MCI 4103088 PN 1070333
5. t 4 MinVent A Low min vent vv A Low Vte o Off 10 20 30 sec o Off 15 60 sec O Off to 99 Ipm in 1 0 increments 4 On 0 Off a System settings O Backlight 1 On o Off eS Language EN IT ES DE FR Icon Ee hPa cmHyO has cmH 0 CD Setup parameter display Leak RR MinVent v PO Humidifier Otos5 2 Reset blower hours x No v Yes CY Provider mode 1 On 0 Off 1 Setup parameter display You can select which measured parameters will display on the monitor screen Choose from K Leak RR Respiratory Rate MinVent Minute Ventilation or Vre Tidal Volume See the Measured Parameter section of the User Manual for more information 2 Provider mode g You can choose 1 or O to enable or disable provider mode Selecting 1 will unlock the device and give access to all ventilation settings in Setup menu Selecting 9 will lock the device so the patient does not have access to his ventilation settings Front panel overview LCD display screen Humidifier number settings Humidifier icon Alarm silence Ramp button button Control wheel Push button 1 If the humidifier is attached to the device when blower is activated the humidification icon and numerical setting will light up on the device 2 Turn control wheel to adjust humidifier number to the desired setting 0 to 5 The settings represent relative humidity levels that will remain consistent throu
Download Pdf Manuals
Related Search
Related Contents
EG I F D E P GR OPERATING INSTRUCTIONS 売上をあげる3つの要素。 - 魔法の3スタンプ・カード USER`S MANUAL - Assured Automation 施工説明書 installations- und wartungsanleitung compact unit Controlador del generador MEC310 Weldanpower 125 - Lincoln Electric Kinect Sports - Center PDK-5011 - Pioneer STM32Cube USB device library Copyright © All rights reserved.