Home
Manual
Contents
1. SMART POWER 8H Remote Control Surveillance Management System AR A L Oo i PRODUCT INTRODUCTION ii lee issssscsccdsasacssescnsscudassssdcasssessedeasousaescuadsodsssccdvesasasdedsessceases 1 I RANGEOE APLICA TON GO O a O Os 1 MONITORING INDICATING CHAR Fi E oi 2 ToS PRODUCT FEATURES sreccssssssormocsnicatents E sis iaa 2 1 4 HARDWARE ENVIRONMENTAL EXPLANATION viscsccssssscnsnssscscssssnnaseaseccenssscassnensedsonscdennaponsonuencsscnnannss 4 1 5 POWER ENVIRONMENTAL EXPLANATION sisi tetas i UG a O Nu Gu y SG 5 1 0 HARDWARE INS TAIRA TIO NA O 5 1 7 PRODUCT TACKA GIN isis 6 HARDWARE OPERA TION cuan da 7 2L POWER SWITCH OPERATION rs 7 2 VASE NES PLAN aieia a No SYN cielo Saati dd i dd dd aaa 8 WEBPAGE OPERATION id yD YC FO aad aY YNA Nad Nawdd aY ON 9 3 DONLINE SE UP aia tada dada 9 DZ INET WV ORR Ke O ETUD a rd o NO EFO An ao 11 IT LIME SYNCHRONIZATION leed 12 SE POWER MONITOR FST FFEFRYN FYNNWN WYF PEY YN FFR AF HF PAO HF FFF FFF NN FFF EA NET FF 14 Oral POWcE WICH SCH GR dn CD Da dida odia 15 2 POWELL wich Operation a eU CO telah eu GA A yb Wn ae teeta 16 Y ADVANCEMENT SETUP saesson cesed Usani eae owa eaa iaaa uresen aua asna oradea 17 AAW POWER MIONEFOR Su A O O lets 17 delel Warnms Temperature Setup eo GY os 17 dna nt ee se id LIS ES N 18 Aa Ne SP OWE Operatoria 18 Aled Powe Conta tato SCLUD a y deal stan Ad o ela GON OU A OS 19 AE ES o is 20 E AD e AZ RN 20 dele Electro Current Deo
2. Device Mail Address a No Vy 2 o See yl Tele sve doe 1 alll 3 Delete o Choose and mark to delete User s Data e Press Delete button to proceed the action of deleting User s Data After deleting the data you must press Save button to store the deleting setup really _ 30 4 4 Time Simultaneity Eguipment Time Equipment Date tyyvy mrm ced 2006 03 20 Equipment Time hh mm ss 15 45 07 Em PC Date tyyyy mm dd 2006 03 20 PC Time hh mm ss 15 45 07 NTP Server Address time stdtime gov tw v New Time Zone GMT Date t yyvyy mm ddi 2006 03 20 Time hh mm s85 15 45 00 Dana Eguipment Date The system date of SmartPower Device Eguipment Time The system time of SmartPower Device Sync with PC If you choose this item the equipment time and computer system time will be identical PC Date The current Computer System Date PC Time The current Computer System Time Sync with NTP Server If you choose this item the equipment time and Time Server will be identical NTP Server Address SmartPower presets several Time Servers for choice If there is not the Time Server you want in the Time Server list you may re add Time Server by yourself and then setup the time Press New button when the window below appears input the NTP server address and then press OK te Explorer User Prompt Script Prompt
3. Please input NTF Server Address Cancel time bellwin com Time Zone This time area is relative to Greenwich time The time for the normal time server is simultaneous with Greenwich Time So it is needed to adjust to local time Manual Setup If you choose this item the equipment time will be setup manually Date Keyin the date manually Please keyin by the correct Date Form Time Keyin the time manually Please keyin by the correct Time Form 4 5 Event Record In this Webpage you may check the operation and warning events in the recent 7 days You may see the action time and operated reason for each Power Switch At the same time if Power Switch can t be operated normally it will produce warning case Operated Event O Warming Event 2006 0321 09 43 50 20060321 09 40 55 006 0321 09 45 53 2006 03 21 09 40 54 2006 05 21 09 48 54 2006 03 21 09 48 55 006 0321 09 40 55 20060321 09 45 57 2006 0321 09 40 50 20060321 08 40 53 2006 03 21 08 46 59 006 0321 09 49 00 200605321 09 49 01 software Reboot Port 1 First Qutlet Power On Port 2 Second Outlet Power On Port 3 Third Outlet P awer Off Port 4 Fourth Outlet Power Off Part 5 Fifth Outlet P awer Off Port 6 Sixth Outlet Power Off Port 6 Sixth Dutlet Power On Port 5 Fifth Outlet ower On Port 4 Fourth Cutlet Power On Porta Third Outlet P awer On Port 2 Second Qutlet P ower Of Port 4 Second Outlet Power On Click to
4. 4 6 2 Download Reset Configuration Download f Reset Configuration Please Select Configuration Bss Upload file The steps of Store Setup File are as below Step 1 Press Download button Step 2 Store Setup File in the catalogue you appointed ye File Download Do you want to save this file Mame cFg bin Type Unknown File Type 768 KB From 192 168 1 21 Save While files From the Internet can be useful some files can potentially harm your computer If you do not trust the source do not save this file What s the risk Save in 96D a mty Music i 2 Amy Pictures My Recent ny Videos Documents SP6V_1 0 060102_EN Desktop My Documents gt My Computer mA a File name cg ka i ave The step to reset configuration are as below Step 1 Press BROWSE button Step 2 Select the catalogue of Setup File and press OPEN after selecting Sc Choose file Look in f My Documents des ei Ed A amy Music E my Pictures My Recent Remy videos Documents E SP6Y_1 0 060102 EN Desktop y Documents My Computer My Network File name cha Places Files of type All Files Cancel Step3 By means of Re set Setup File Function when you press Upload button it will be displayed according to the following state SmartPower will reboot automatically an
5. in column Select model and then choose COM1 for On port Pull down list click Next button last UPS Selection select manufacturer Select model 8 After entering the window of UPS Interface Configuration On set up all of the pole signals as Positive and then click Finish button UPS Interface Configuration On COM1 UPS Signal Polarity Warming Please consult your UPS documentation before attempting to configure signal polarities Power Fail On Battery O Negative Low Batter O Negative UPS Shutdown O Negative Attachment A How to return SmartPower setup _45 to initial value When you forget the password of network account of SmartPower you can utilize RESET button of SmartPower to return the initial value At the same time SmartPower will carry out the action of reboot too Please note after operating RESET button It will clear up all the users information Meanwhile the webpage management account number and password to return to admin And the phone password will be returned to 123456 the network site will be to 192 168 1 10 The other data will be remained unchanged Use nib or thing to press Reset button slightly After seconds the phone indicating light will flash and then the machine will be reboot Phone Indicating Light Reset Button 46 Attachment B How to use tape recorder to record equipm
6. you can enter this screen Y Remete Dove Han pcimest 5 Fle Edt Wea Faber Took Help Qa O Ma e Pew 6 OBS Address hopa 1 10 Ay Or Remote Control Tyner Account Tinia Sie Event Upgrade Dere Temp 32 T e A a Exi Tamg W A Waiting Tang El T j 10 3 2 Network Setup After you select function System in homepage choose Network Network lide s Sut HEN 265 255 0 so 7 Domai an Server I Web Server Setun 4 J CD o Network Setup Please fill in IP site sub network shade preset communication gate data offered by the service center of the supplier according to your network setup state to input the data If you don t have relevant data on hand please inquire to your ISP service center This product only provides for the establishment of regular IP If your connect type to surf the Net is by dialing please cooperate to use with IP Hub EJ Domain Name Server Setup Please fill in your DNS server provided by ISP service center You can setup two sets of DNS servers If you don t know DNS server site you may check your DNS service by input C gt nslookup in Subsidiary application program Order prompted character 11 gt nz lookup Default Server dns hinet net Address 168 95 1 1 gt E Web Server Setup When you connect with SmartPower through webpage browser e g IE if you do not wa
7. because of the network or the computer equipment system halted during their vacations often find that only needs to reboot the power to solve the problem So SmartPower integrates the power control the electric current monitor eguipment temperature control UPS control webpage management voice control messages E mail and API function to let MIS personnel learn the power state of the eguipment as soon as possible and can deal with the relevant problem with voice or network far to solve the problem lt reduces the enterprise s losses as well as saves MIS personnel s traveling time 1 1 Range of Application The monitoring and management of the computer equipment room The power management of the computer centers of every organization The machinery equipment power control of the factory building The network equipment power monitoring Other power equipment power monitoring 1 2 Monitoring Indicating Chart SERVER1 SERVER2 SERVER3 SERVER4 SERVERS SERVER SERVERT SERVERS F 1 3 Product Features Control the remote equipment power switch through the network or the telephone voice message to replace personnel to come to the scene personally a LED panel looks over the current equipment ID total electric current and all routes electric current directly a It may ink to 16 sets at most and control 128 sets of equipments at most Detect two sets of Power Circuit are normal or not automatically B
8. ent please mark the item Reboot and then use Mouse to press left key twice sl yy gt Advancement Setup This chapter is mainly to explain the advancement operation in SmartPower webpage You may learn about Power Monitor System Setup Account Management Time Synchronization Event Record and Firmware Upgrade the detailed explanation for all of these functions 4 1 Power Monitor In this webpage you may proceed the setup for Basic Data Working Schedule Safety Shutdown Network Detect Electric Current Monitor Temperature Monitor through browser operation for power switch and Voice Sending 4 1 1 Warning Temperature Setup This block is to display the present device temperature and outer temperature of SmartPower and setup the warning temperature for outer temperature Device Temp a2 L Ext Temp M A Warning Temp 8D de Device Temperature Display the current temperature of SmartPower Temperature will change according to the surrounding temperature If the environment temperature rises the temperature of SmartPower will rise too Exterior Temperature If you connect temperture detector It may display the current exterior temperature If not it will display N A Warning Temperature If you connect temperature detector to setup a basic warning temperature when the equipment temperature rises to this temperature the system will send the warning message by setup email and message to all of
9. for convenience of the user to answer the phone firstly When the phone is nobody answered SmartPower will answer it then Ring Setup Reboot power switch Choice Language English se SAVE Answering Ring Setup Setup the answering ring times Reboot Power Switch Setup if the selection of Power Switch Reboot is on START or not Choice Language you may select the traditional Chinese or English to change webpage interface and phone voice language version _ 28 4 3 Account Management Choose Account in Webpage Management Function List and then proceed the Account Management You may setup 20 sets of accounts in total 4 3 1 Account Add Account When enter the webpage it will reguest to input User s account Password When enter the webpage it will reguest to input User s password TEL Password When operate by phone the phone voice will reguest to input the password for six digits Cellphone When there is a warning the mobile phone number it will transmit to Mail Address When there is a warning case the email address it will transmit to Device No Select the device code you want to setup the right Each set of account may setup the using right for each route of power supply switch according to each set of SamrtPower You may setup the using authorization for all routes power switch according to each account setup 29 4 3 2 Account Delete
10. last stage please press Y metel Facility ponar Please walk 23092 5 3 Electric Current Reading Procedure the Current Power Code if YoU want to te First Route for First Set Judge if the keyin is correct the Power Code you entered is not existed Please re enter Correct 3 a mi e x L Limits of Insufficiency sorry you have no right authorization for a to control set XX Please judgement re enter Sufficient The Power Code you chose X The present current is AA degree A0 X Safety Switch Assembly and Setup 6 1 Connecting Chart 6 2 Setup 1 Enter Windows Control Panel double click the Administrative Tools icon E Control Panel Ea tx a Fie Edit View Favorites Tools Help Q sack k a a DO search gt Folders Address Vg Control Panel E Accessibility Add Hardware Addor A Switch bo Category View Options Remove Tools See Also j pa UN Automatic Date and Time Display Folder Options Wp Windows Update Updates Help and Support e Ti Game Internet Keyboard Controllers Options eo b Network Network Setup Phone and Connections Wizard Modem 2 After entering Administrative Tools and then double click the Services icon Fr Administrative Tools File Edit View Favorites Tools Help pack 3 ys Search gt Folders Hab i f Bd E ag File and Folder Tasks 4 gt El mm aY ie e Componen
11. the user s accounts e When you finish setup for the above data please make sure to press the key of Save to store all of the data setup 4 1 2 Eguipment Selection In this area you may select SmartPower eguipment you want to monitor and check the total current and connecting state of this eguipment hl g Total Current 0 Amp AF 2 Ao 3 y 91 4 O5 8 Total Current Display the present loading total current of this SmartPower Illustration Connect Disconnect gt Overdue gt Not Authorized gt Lights Explanation means this route s power ON means this route s power OFF It can be linked to 16 sets of SmartPower equipments at most 4 1 3 Power Operation Every route power provides the explanation for Power Data Setup Power ON Power OFF Power Reboot present electric current value and Power Eguipment 0 00Amp Reboot First Outlet le Button Illustration ami ON OFF OFF gt Not Authorized L f Local Side under control No Power gt Power Overloading 4 1 4 Power Configuration Setup The main purpose for Power Set List is to setup the relative data for all routes power switches W Configuration e Network e gt Current lev Direct Start Shutdown a IAE shutdown Shutdown Delay Time Delay Time First Ouilet O reattime reattime x Discription The discription for all routes of Power Switch equipment after setup
12. 21 Alas TEMPEratute MOI diera UO 21 ql Voice ES Send A A O DN 22 AZ SYSTEM SETUP ritos dild 23 42221 Network SCUD a a a Seles DG A ban aiuto 23 422 Emaiu ec o o a eels 24 A Sa ELV Clr A Ue A se OO 25 de NND UD ere aera ne NT TN eT IO CoO NT BED Tee Ca ne oP aC eee er 26 AS a ORT TaN Tuna ee MRR Me eG ET FN 2 A2 OOE Se UD S ess POE o E 28 AS ACCOUNT MANAGEMEN T cren A 29 a AEE ena E AY 6 A a AEE E ATIE EEE O EEE E E AS 29 E ACCO De Ee aa A RR a RH RHYN 30 A MIES A E ET 31 Aer EVENT oll CLG Dd E A o ie 32 O FIR NN AREUPORLDE GG a a o a el lo E 33 aol mw are Up a E AU A A A SO 33 4 6 2 Download Reset Configuration occcccncccncncnonononnnnnnncnnnnnnnnnnnnnnnnnnnonnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnns 34 PHONETIC OPERATION PROCEDURE 2 cceccccccccccccccccccccccccccccccccccccccccccccccsccecces 37 92 MAIN PROCEDURE es a GO rar o e a ON DS DA DR ese ones YDA AD e dol bei 38 5 2 POWER CONTROL PROCEDURE 00 dianas 39 5 3 ELECTRIC CURRENT READING PROCEDURE ad el actin el 40 KX SAFETY SWITCH ASSEMBLY AND SETUP 11 cccccccccccccccccccccccccccccccccccccccccccccccees 41 O LCONNECTINO GR ea le AL e rl a e te uh ret ee o 41 O ETUF O 42 ATTACHMENT A HOW TO RETURN SMARTPOWER SETUP TO INITIAL VALUE 45 ATTACHMENT B HOW TO USE TAPE RECORDER TO RECORD EQUIPMENT VOICE ke Product Introduction The MIS personnel of lots of enterprises after coming back to the office
13. Power will have bee sound So when the user wants to operate Power Switch he must press lastingly release the hand only when SmartPower has bee sound When Green Light is on it means it can be operated by LOCAL operation This time you can press the button twice to open or close the power Red Light means Power is on After leaving from operating by Local side please press the button lastingly till SmartPower has bee sound to cancel the operation by Local side By doing so the remote side can operate this route s power by webpage o Power State When the green light in SmartPower is on it means it is operated by Local side When the light is not ON it means it is operated by remote control The red light in SmartPower is on it means the power is ON If the light is not flash it means it is off If red light flashes slowly it means it is on delay start while red light flashes guickly it means it is on delay shutdown The o delay time for Start and Shutdown can be setup in the Power Monitor of the webpage e Compulsory Shutdown If the delay shutdown of the power is long you may press the power button lastingly till the first bee sound and then hearing the second sound about 10 seconds to shutdown the power compulsorily 2 2 LED Display In LED panel of SmartPower it will display all various currents total current and SmartPower temperature Normally the data LED displays is to
14. al Curen 1 Amp ija Ew Taip MAA O a O 5 Mo J te 1 5 8 Warning Tarp A it a A A a First Outlet 49
15. ating Light a Phone Line Connect Port 12 ID Current Indication ES RJ45 Network Connect Port Phone Indicating Light Route 1 4 Power Indication Route 5 8 Power Indication Network Indicating Light Breaker Protector 6 Stack Extension Interface Power Switch Power Switch Indicating Light Main Power Switch I Power Switch Socket UPS Connect Port Local Terminal Operate NT Port Connect Port Indicating Light ID Indicating Light 1 5 Power Environmental Explanation Power Socket NEMA 15R Max Main Output Current 15 Amp Power Input 95 264VAC 47 63Hz Power Freguency 50 60 HZ Operating Temp 0 60C Machine Frame Size 19 Standard Type Machine Frame Shape Size 445 x 216 x 44 mm WxDxH Machine Net Weight 3 5 KG Consumption Efficiency 12 5 W 1 6 Hardware Installation Ethernet HUB 1 7 Product Packaging Remote Power Monitor 1 CD Rom of User s Manual 1 Manual amp Utility Power Supply Cord 2 Safety Switch Line 8 Machine Frame Fixer 2 Screw 4 If any of the above accessories are missed or can t be used please contact with the location you purchased for replacement in 7 days Hardware Operation In this Chapter you may learn how to turn ON and OFF the power by button in the hardware of SmartPower as well as the represented meaning in LED panel 2 1 Power Switch Operation You can control power switch directly by the button in SmartPower When press the button Smart
16. choose Operated Event or Warning Event and choose date from date bar then press OK button It will show the event information e Download button means save the information to be a csv file in the HD Delete button means delete the information 4 6 Firmware Upgrade You may download the newest Firmware in the website of the supplier to proceed SmartPower Upgrade 4 6 1 Firmware Upgrade Production Name SP8H System Version 1 03 060927 Browse Firmware Upgrade Please Select File Steps of Upgrade are as below Step 1 Press BROWSE button Step 2 Select the catalogue of Firmware Renew File and press OPEN after selecting the file ose file Leckie O MyDoomens gt Mek Be My Recent Documents E Desktop Y My Documents hy Computer My Network File name ISPEV_1 0 060102_EN Places i Files of type E Files o Cancel 302 Step3 By means of upgraded Firmware Function when you press Upgrade Firmware Upgrade button it will display according to the following state Router will re start automatically and finish the firmware upgraded Updated Renewing please hold 55 Caution During renewing please dont proceed random shutdown or re start or the unpredicted error may happen If the file you choose is not Firmware file or it is old fashioned version you can t do the action of SmartPower Upgrading
17. d will finish Setup File Reset Updated Renewing please hold 55 Caution Durina renewing please dont proceed random shutdown or re start or the unpredicted error may happen When the file you choose is not SETUP File you can t proceed the action of SmartPower Setup File Reset 36 A Phonetic Operation Procedure This chapter is mainly to explain the operation procedure for SmartPower Phonetic System The users can use the phone to dial the voicemail to operate the Power Switch and read the electric current temperature and website This chapter is divided into the Main Procedure the Power Control Procedure and Power Electric Current Procedure After finish playing the phone voic for over 5 seconds if you do not press any key it will hang up the phone automatically to prevent from phone line jammed X The prompted Phonetic system password for this system account admin is 123456 mb 5 1 Main Procedure _ ED 7 p D ial Phone Mt moel Three times of incorrect password Identify the ncorrect password J password Correct a m Yes Three times of ncorrect password Check before dialing Please press 1 for Control Power Press 2 for Inquiring about Current Press 3 for inquiring Total Current Press 4 for inquiring about SmartPower device Temperature Press 5 for Inquiring about SmartPower IP 3 The present lhe F for SmartPower total current Is Temperatur
18. e CE XR MM AMO MRON O Amper senser The present outer Can not detect outer surrounding environmenta temperatureis XX temperature The gegree SENSE Is MEyLE pasene OF MOL existed 35 e 5 2 Power Control Procedure Please press to shutdown Facdity Power Press 2 to reboot it Go back to last stage please press E Closing Is normal or mol Yes Shutdown Facility Power Please wait Failure to Shutdown Computer Shutdown Facility Facility Power Completed Please press 1 to forte shutdown the Facility Power Go back to last stage please press E shido Facil Power Lomaoleled 2 ii Reboot ri normau ae mui Yes Reboot Facility nower Please WEL Please enter Pmver Code you mieng to control lo operate First Route of First yl et please press FUIT in telephone key Press to be back to Fast aya rym A k sorry Mo pona coda identify Fit you enterada is nol s correct existed Pleaze rein Insufficient Sorry you have na night to control set XX Please reenter chen By Sufficient nn code you chose se AA Curren state s Under opening Please reenter Closing Please re enter Press 1 fr Starting Equipment Power Ga back lo last slaga pienso press Y start Facility Powar Parse wall Starl Faceity Power Completed Fadure to reboot Computer Facility Please press to force start the facility power Go back to
19. e equipped with Overloading Breaker protector to prevent power overloading and equipment damage You can add temperature detector to control power switch according to surrounding temperature Execute the management function of Power On Off Reboot by means of Console Support nearby manual power switch a Support the setup of Power Supply sequence to prevent from all of switches starting simultaneously to cause the sudden overloading and bad effect to equipment working e Provide 20 sets of settable accounts and passwords to manage different power switches Preset switch time and arrange working schedule Support Windows Linux to carry out the work of safety shut down to prevent system from damage Support Function of Wake on Ring ATX equipment can be start normally Detect the electric currents of all routes are normal or not to prevent electric current from overloading and damage Messages warning E mail report execute the monitoring of the important eguipment in time Record the user s operating messages and abnormal messages for user s reference afterwards Offer API interface The administrator can develop the control software by himself by oneself Every circuit can detect UPS low electric signal and provide equipment safety shutdown process Provide the function for upgrade the Web Line Firmware 1 4 Hardware Environmental Explanation li Console Connect Port RS232 TM Total Current Indic
20. ent voice file You can utilize recorder procedure of Windows to record equipment voice file and reach it to the equipment of SmartPower a Turn on the recorder procedure in Windows to record your equipment voice message 2 Sound Sound Recorder Sime File Edit Effects Help Position 0 00 sec m jE EJ Turn on the recorder File Properties after selecting press the voice file content transform to CCITT u Law 8KHz 8 bytes J Sound Sound Recorder all aE Edit Effects Help M a Length t 0 00 sec Save Save AS UTE Properties for Sound Details Sound Copyright No Copyright information Length 0 00 sec Data Size O bytes Audio Format PCM 22 050 kHz 16 Bit Mono Format Conversion Ki To adjust the sound quality or use less space for this sound click Convert Now Choose from Vl formats Sound Selection Mame Tuntitled Y Save s Format PEO A EA Attributes 3 000 kHz 8 Bit Mono kb zegs cos 48 ED It will store the recorded equipment voice file to the catalogue you appointed Save As x Save in E Mu Documents dm E EE Es Save as type Sounds Pas Cancel Ze o It will store it while reaching SmartPower equipment on the equipment voice file of your computer please refer to 4 1 9 FT RL iL Evont Lipqrada Device Temp 32 T Tot
21. ete this schedule please double press the deleting illustration of this schedule 4 1 6 Network Detect When the Power Connected equipment is the web equipment you can setup the monitored web eguipment site monitoring interval time detective numbers of times reboot or not and re detect time Detect p PING Interval Time 192 168 110 o O EO a Re detect Time Detect When the Power connected equipment is the web equipment whether detect or not Equipment Network Address When the Power connected equipment is the web equipment it is the monitored web equipment site 20 PING Interval Time When the Power connected equipment is web equipment it is the Interval Time to execute PING network equipment Detect Times When PING failed detecting time is over this setup value it will send the warning message through the set message or email Reboot When PING failed detecting time is over this setup value whether the web eguipment shall be re started or not Re detect Time When re start the web eguipment delay the eguipment time and then re monitor the web eguipment 4 1 7 Electric Current Detect Detect the power current is abnormal or not This webpage can be setup for overloading shutdown overloading warning and lower warning ww Current Warning 0 04 amp Continuous Time Overload Y Overload shutdown 1 Amp varning O 55 Amp L
22. is relative to Greenwich time O Manual Setup You may also setup SmartPower system time by manual Just keyin the date and time you want to setup in the columns of Date and Time When you finish setup for the above data please make sure to press the key of Save to store all of the data setup a l c 3 4 Power Monitor After setup the above Webpage you can choose Monitor in Webpage Management Function List In this page you may not only operate Power Switch but also setup the relative data in every route of Power Eguipment LL mm En Temp PA Warm Tarn El a 1 4 Wn First Cartier oe 3 4 1 Power Switch Setup o If you want to link many sets of SmartPower firstly please select the exact SmartPower you want to set up fir 2 When you press Set button to turn orange it means you will setup that Power data Move Mouse to the explanation colum of Power Setup and keyin the explanation date of this Route Power Equipment o When you finish setup for the above data please make sure to press the key of Save to store all of the data setup NES 3 4 2 Power Switch Operation _ON a O 004mn Reboot 0 o Press left Key of Mouse twice to open or close all of the Eguipment Power o Display all route Power Status and Data and may use Mouse to press its left key twice to switch the Power If you want to reboot the equipm
23. it will reveal under switch column for convenience of the manager to distinguish the equipment name connected with all routes power Direct Shutdown When you select this column it means the power will be shut down directly after the setup delay time when you execute the action of power shutdown Safety Shutdown If you select this column it means when you execute the power shutdown action it will proceed the shutdown action for this route power first please refer to Computer Safety Shutdown Setup 4 1 5 and then close Start Delay Time When Power is ON it is time to wait for Power Start Delay Time Shutdown Delay Time When Power is OFF it is time to wait for Power Shutdown Delay Time 19 4 1 5 Working Schedule You may select the working schedule for setup the power eguipment ON or OFF here EE Schedule Recurrence Time Action Delete Month x Week Monday 0800 Week Monday 22 00 Ox Recurrence Manth it v D1 l oo v On v Recurrence you can select the action recurrence of this route s power The recurrence can be divided into year month week day For example If the recurrence is by day it means this route s power will activate at set time each day Time Setup the working time of this route s power It is dragged to the page bottom Action Setup this route s power s working schedule is on off or reboot Delete If you want to del
24. lick OK Uninterruptible Power Supply Properties Local Comp Ed Genera og On y fecovery Dependencies Log on as Local System account Allow service to interact with desktop 2 This account Password You can enable or disable this service for the hardware profiles listed below Hardware Profile Service Profile 1 Enabled i z 5 Double click on the Control Panel s Power Options icon n E Control Panel File Edit View Favorites Tools Help Q d LO Search Folders Hak Address m Control Panel l Net Network Setup Phone and ES Switch to Category View Connections Wizard Modem See Also ES s sy l AA S Frinters and Regional and Scanners and windows Update te ew Faxes Language Cameras 6 Help and Support Scheduled Security Sounds and Speech Tasks Center Audio Devices 82 Taskbar and User Accounts Miware Tools Start Menu 6 Select the UPS page UPS and then click on Select Power Options Properties Power Schemes Advanced Hibernate Uninterruptible Power Supply Curent power source Estimated UPS runtime Estimated UPS capacity Battery conditions Manufacturer None Model Configure Select a The UPS service is curently stopped 7 After open UPS Selection window choose the Generic from the Select _44 manufacturer Pull down list and then click Custom
25. mperature is lower than the setup temperature this route power equipment will re start automatically Source you may select the monitored device temperature or exterior temperature 4 1 9 Voice File Sending The user can record the voice file by sending to point out the equipment name for present power switch connected when operate by phone Y Configuration El Schedule Ta Network Current C Temperature 4 Voice Voice File Upload begin upload Browse begin upload Press BROWSE button to open File Select window and choose the voice file you will send and then press Begin Upload The Voice File Form is PCM A Law u Law 8K 8Bit and less than 40K about 5 seconds In regards to the recording operation for Voice File please refer to Attachment B e 4 2 System Setup In this webpage you may setup telephone answering numbers web basic data email server and message service setup for all of the relative data 4 2 1 Network Setup Setup Network basic data E SMS Server 4 SNN Network SEA sddress 192 168 1 10 255 255 255 0 Gateway 192 168 1 1 Domain Name Server Setup an C Web Server Setup v IP Address Setup to connect with Network IP address of this equipment Subnet Mask Setup Network mask of this equipment Gateway Setup exterior Gateway Site of this equipment DNS Server 1 The site of the first Web Area Serve
26. nt to use the decided HTTPS connect port normally for 443 you may change HTTPS connect port to be other value e g 8080 and then you may re connect to SmartPower and input the HTTP connect port you appointed e g https 192 168 1 10 8080 o When you finish setup for the above data please make sure to press the key of Save to store all of the data setup 3 3 Time Synchronization The time zone that SmartPower adopts is for 24 hours and will regard this time as the time basis that information will be recorded When you use for the first time you can choose TimeSync from function form in webpage After selecting you can proceed the setup of time synchronization s12 Eguipment Time Equipment Date yyyy mm dd 2006 03 20 Equipment Time hh mm ss 15 45 07 System Time PC Date yyyy mm dd 2006 03 20 PC Time hh mm ss 15 45 07 NTP Server Address time stdtime gov tw M o0 Time Zone GMT 108 y T h A oo ye ar lr A cn yn _ Manual setup Date yyyy mm dd 2006 03 20 Time hh mm ss 15 46 00 Sawe Equipment Time Setup is divided into three types Please choose one to setup as you want O Sync with PC SmartPower will setup the time of eguipment system as the computer date and time display as in the webpage O Sync with NTP Server Please choose to setup the same time as Server first and then point out your local time Please note this time area
27. ower Current Y Overload Shutdown When the equipment power current is over the setup current value if it exceeds the continuous time the power will be close automatically Continuous Time When the equipment power current is over the overloading shutdown current if it exceeds the setup continuous time the power for this route will be close automatically Overload Warning When the equipment power current is over the setup current value the warning message will be sent by the setup email and message to all of the account users Lower Current Warning When the equipment power current is less than the set current value it will send the warning message by setup email and message to all of the account users 4 1 8 Temperature Monitor When detect the temperature of SmartPower is abnormal is it necessary to proceed the action of open or close the power switch 21 HYN rene MR 2 E Device Temperature v SOuUrce Power Shutdown When the equipment power temperature is over than the setup temperature if it exceeds the continuous time the route of power will be close automatically Continuous Time When the temperature of equipment power is over than the setup temperature for power off if it is over the setup continuous time this route power will be close automatically Power Start If the equipment power had been close because of high temperature when the te
28. r DNS Server 2 The site of the second Web Area Server Http Port Open Marking this column means that allow user can open browser to connect the device by http protocol Http Port Provide the browser to be connected with the appointed Http port to this equipment Http SSL Port Provide the browser to be connected with the appointed Http SSL port to this eguipment nm API Port Provide the Application Program to be connected with the appointed connect port to this equipment This product provides API for the user to develop program connected with this eguipment to get the power electric current temperature status and control power please refer to the explanation 6 3 You must setup the network vent connecting the program with this eguipment 4 2 2 Email Server Setup When there is a warning the email service data setup for sending the warning case m4 Mail Server Email Server Setup SMTF Serer Address mail belhwin corr ty SMTP Part 25 sender Mail Address smartpowendbellwin com tw Mail Subject smartpower Warning SMTP Auth SMTP Account admin SMTP Password ill Dave SMTP Server Address When the warning message is sent by email you must help to send out the email to the main server address SMTP Port When the warning is sent by email you must help to send out the email to main server connect port The preset value is 25 Sender Mail Address When the Receiver gets the email it
29. t Computer Data Sources Event viewer Services Management ir Move this File E Copy this File Yg eS Publish this File to the Web Local Security Performance Poli E mail this file olicy yM Delete this file Dther Places 3 After entering Services and then double click on the Uninterruptible Power sc Supply service Hee ls Services File Action View Help EA Services Local DYN Services Local Uninterruptible Power Supply Description status Startup Log On As Bs Telephony Provides Tel Manual Local System Start the service Sy Telnet Enables are Disabled Local System Ba Terminal Services Allows multip Started Manual Local System Description j j Manages an uninterruptible power supply Sae e E TN es i Manages an UPS connected to the computer ity VMware Tools Service Provides sup Started Automatic Local System Eg volume Shadow Copy Manages arn Manual Local System Sea webclient Enables Win Started Automatic Local Service Sa windows Audio Manages au Started Automatic Local System Sa Windows Firewall Internet Con Provides net Started Automatic Local System Es windows Image Acquisition WIA Provides ima Manual Local System Sy Windows Installer Adds modifi Manual Local System N Extended A Standard 4 In the Uninterruptible Power Supply select the Log on as This account button input the appropriate account information and then c
30. tal current and SmartPower temperature If needs to display all routes currents pleas press the relative switch of that power switch At this moment you will hear bee sound At the same time the Local operating light will flash and LED panel will display the current of this route for 3 seconds Local Terminal Operate ID Indicating Light Indicating Light Total Current ID Current Indicating Light Indication e Temperature Display When you press Power Switch of 6 route and then press 8 LED panel will display the temperature of SmartPower for 3 seconds e Equipment ID Display When you press Power Switch of 7 route and then press 8 LED panel will display the equipment ID of SmartPower for 3 seconds This moment ID Indicating Light will be flashing Webpage Operation In this Chapter you can learn how to setup network data eguipment time power basic data and how to operate power switch via network quickly 3 1 Online Setup I After line make sure to input https 192 168 1 10 to connect with webpage manager A Remote Power Management 5ystem File Edit View Favorites Tools Help Q O 2 ddress E htpsWl92 168 1 10 2 After the logging screen appears please key in admin as user s name and key in admin in the blank of password SmartPower _ Remember my password When you key in the correct user s name and password as the instruction of Step
31. trator system Location Office TRAP Notification Recever IP Address 192 165 1 213 Recelver Port Community Enabled public MININ q i 1 Save System Name Display System Name on the program of SNMP Client System Contact Display System Contact Person on the program of SNMP Client System Location Display System Site on the program of SNMP Client Receiver IP Address When something happens to Trap and it is IP site which will be sent to Trap Receiver Port When something happens to Trap and intends to send to Trap server it is the Connect Port for Trap server The inner setup value is 162 Community When something happens to Trap and intends to transmit to Trap server the group will be sent to Trap server Enabled While mark the using option if something happens to Trap Trap Case Information will be sent to the appointed Trap server _ 26 4 2 5 UPS Setup Select when detect UPS is out of power it will shutdown all of the computer equipment automatically Ta Network Mail Server E SMS Server 4 SNMP UPS UPS Detect an TE e E E E IE S IS La S IS La stave 7 TE Save e 4 2 6 Other Setups You may setup when the user enters by phone the system will execute IVR process after several rings When SmartPower is connected with other phone you can setup the larger ring answering value
32. will be revealed in sender s data of email Mail Subject When the Receiver gets the email it will be revealed in Subject data of email SMTP Auth If the setup mail server needs to identify the user please mark this item and setup the account and password 24 SMTP Account Loaded account for email server SMTP Password Loaded password for email server 4 2 3 Message Server Setup When there is a warning setup the warning message data in the Message Server fa SMS Server Message Server Setup server Address 192 168 1 4 Port 2500 Equipment Name Remote Power Management System Account admin Password Cree Send SMS SMS Test Saye Server Address When the warning system is sending the message it helps to send the message to the server address Port When the warning system is sending the message it helps to send the message to the server main connect port The preset value is 2500 Equipment Name When the receiver gets the message it will be revealed in the data of Message Sender Account Account to load in Message Server Password Password to load in Message Server send SMS If it is needed to start Message Sending mechanic _25 4 2 4 SNMP Setup Tm Network amp Mail Server amp SMS Server JO SNMP UPS Other ien a Pe ae a E e a ee a ee i cen bee ANA AI A a E wb Sm ES h MIB System 1 ELA system Mame SmartPower oh system Contact Adminis