Home

COLORado 4 IP User Manual Rev. 5

image

Contents

1. 9 CONTOLODUON Sd 9 Progra Oe EE LO EE PR ETE 9 DNX i is Tc 10 DMX eoi ETC 10 HOSS OE SIGN al SO MITIS MERETUR RE NEU m 10 A uel ees cees 10 AUO EE 11 CUS LORIN MEM c X H OR 11 WEE La a O MP O a MU e aa 11 __ _ 223332 22 3 _ _ _ _ _ ___ _ __3 _ __ _ 4 11 Dimmer GUL Ves 12 SUR T SS STUNG 9 12 Control Panel Loteria titi 12 O 12 SEMOS LOCK QUE TR 12 Program Upload mr rrr TM 13 Rc MH C Te RE E RR RS E E RR ee 13 C89 860 5CI005 RESE etas e e Lecta podes DRE coats 13 _ 3 33 2 3 3 3 _ 22 22 2 2 3_ _ ___ _ __ _ _ _ _ _ 14 I T T RS 14 SVODE Ei Tc EP 14 EN EE 15 Menu Nap COMMS as assassina 16 AA
2. P isa 17 Colorado 4 IP User Manual Rev 5 S Table of Contents PROFESSIONAL DMX Vales Ceenn o E 18 DMX Values Continued EE 19 DMX Values Contmued RR RR 20 DIMAS Valles GONE e Dios 21 BMX Valles e dn e a te 22 DI Valles GONE rc re Y 23 o TECANICALIMO EN d Vu ME 24 _2 22 23 3 3 33 3 3 33 _3 33 3 lt 33 3 24 _ ___ _ ___ _ _ _ _____ _ _ _ _ __ _ _ _ _ _ ____ ___ _____ _ _ _ _ _ _ _ _ ___ ____ _ _ _ _ 24 Keeler Eelere 6 6 0 25 _ _ lt CC C lt CC 008 gt CCCCC 2 gt 26 Colorado 4 IP User Manual Rev 5 nu El Before You Begin uN 1 Before You Begin What Is Included COLORado 4 IP IP66 Power Input Cord Male Female 5 pin IP66 Adaptor Warranty Card Quick Reference Guide Claims Carefully unpack the product immediately and check the box to make sure all the parts are in the package and are in good condition If the box or the contents the product and included accessories appear damaged from shipping or show signs of mishandling notify the carrier immediately not Chauvet Failure to report damage to
3. Power In DMX In DMX Out Rear View Power Out Yoke Adjustment Safety Loop Side View AS ColoradoTM4 IP User Manual Rev 5 Dimensions Front View Side View Colorado 4 IP User Manual Rev 5 5 Setup 3 Setup AC Power AC Plug 41110 PROFESS AL i Each COLORado 4 IP has an auto ranging power supply that works with an input voltage range of 100 240 VAC 50 60 Hz To determine the power requirements for each COLORado 4 IP refer to the label affixed to the product You can also refer to the Technical Specifications in this manual The listed current rating indicates the maximum current draw during normal operation For more information you may download Sizing Circuit Breakers from the Chauvet website www chauvetprofessional com Always connect this product to a protected circuit with an appropriate electrical ground to avoid the risk of electrocution or fire To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugging it Never connect this product to a rheostat variable resistor or dimmer circuit even if the rheostat or dimmer channel serves only as a 0 to 10096 switch The COLORado 4 IP comes with an IP66 power input cord terminated with a proprietary IP66 connector and an IP66 to Edison power cord adapter If the power cord adapter that came with your product has no plug or you n
4. _ _ _ _ 1 Mantal ee ado BRETT EO Nem 1 O VINDOS assetto ute A IM E See M E E uie MR oat te S put MEME EL 1 Prod ctaka lance ninia m ES 2 SN e t T K eustede 2 Personal oale Ve uM e MUNI A EU DI E CIE 2 Mounting and FIG o a o KEE 2 FONE ana NIRO serao e a 2 A A cer 2 Expected GR TE e EE 2 ON PRENNE TTE ET e T ETE 3 FrOQUELDESCHDHON aspas E wm een eeine 3 Qi 4 MA e A e 5 3 568018 eec EA SE TNR 6 _ _ _ _ 3 2 33 32 lt 23 23 233 323 _ 3 lt 3 lt lt lt 2 2 3 _ 6 A A A 1 47 E 6 POWer Min digo a 7 A O 7 DINA REIS Fa sc TERT OOo erm 7 Masten Slave Cobre EE 7 _ 2 _ 3 23 322223 _ 323 3333 _______ ___ __ _ _ 8 CENA EU SES TTD pm 8 5101611012 MEPE EE ETE EOE COE EE E 8 3233 3 3 _ _ _ 2 gt gt gt 9 gt 9 gt 9 615 811 5 526 1612101812 1511611618825 7
5. 0700 079 LIX 1 4 080 089 Pix 2 3 090 099 Pix2 4 100U 109 Pix3 4 static static static static static static 1100 119 Pix 1 2 3 static 120 129 Pix 1 2 4 static 130U 139 Pix 1 3 4 static 140 U 149 Pix 2 3 4 static 150U 159 Pix 1 2 3 4 static 160U 179 Chase left to right 180 199 Chase ri ght to left 200 U 219 Chase left right left 220U 239 Random 240U 255 Pix 1 2 3 4 static Function Value Red 0000 255 0 1009 Green 0000 255 Jo 100 Blue 000 255 0 100 Function Value Dimmer 0000 255 0 100 Red 0000 255 Jo 100 Green 0000 255 0 100 Blue 000 255 0 100 Function Value Red gt 0000 255 0 100 Green 0000 255 Jo 100 Bue gt 0000 255 Jo 100 White 000 255 0 100 Percent Setting Percent Setting Percent Setting 21 Operation DMX Values Continued AR2 S Channel Function Value 2 Re 0000 25 Jo 100 3 Green 0000 255 0 100 4 Blue 0000 255 0 100 000 U 009 No Function 010U 019 1 Hz 020 029 2Hz 030 U 039 13 Hz 040 049 4 Hz 050 059 5 Hz 060 U 069 6 Hz 0700 079 7 Hz 080 U 089 8 Hz 090 099 9 Hz 6 Classic Strobe 100 109 110 Hz 1100 119 11 Hz 120 129 12 Hz 130 139 13 Hz 140 149 14 Hz 150 159 15Hz 1600 169 16 Hz 170 179 17 Hz 180 189 18 Hz 1900 199 19 Hz 200 U 255 20 Hz HSV Channel Function Value 3 Valu
6. One COLORado 4 IP becomes the master when running an Auto or Custom program or by being in Static mode You must configure each slave to operate in Slave mode During Master Slave operation the slaves will operate in unison with the master DO NOT connect a DMX controller to products operating in Master Slave mode The DMX controller signals may interfere with the signals from the master The Operation section of this manual provides detailed instructions on how to configure Master and Slaves Note For optimum control of the 16 bit dimming channels in the TR16 personality be sure that both dimming curves in SET gt DIMX and SET gt CURV are set to OFF If you are not familiar with or need more information about DMX standards Master Slave connectivity or the DMX cables needed to link this product to a DMX controller download the DMX Primer from the Chauvet website www chauvetprofessional com v Mounting Before mounting this product read and follow the Safety Notes For our CHAUVET Professional line of mounting clamps go to htip trusst com products Orientation Always mount this product in a safe position and make sure there is adequate room for ventilation configuration and maintenance Rigging The COLORado 4 IP consists of a double bracketed yoke and the body of the product Chauvet recommends using the following general guidelines when mounting this product The product is not intended for permanent insta
7. gt RGBW you will only be able to define the values of RED GREN green and BLUE The values of RED GREN green and BLUE configured from CAL gt CAL2 gt RGB W will define the color temperature shown when the RGB faders are set to 255 if SET gt COLO gt RGBW is active This setting allows you to select the CLASSIC 01 20 Hz strobe or SPECIAL Random Slow Fast strobe personalities 1 Goto the SET main level 2 Select a strobe personality SPEC or CLAS se Oo qe Colorado 4 IP User Manual Rev 5 CHAUIET PROFESSIONAL Menu Map Main Level STAT AUTO RUN DMX PERS EDIT Operation Programming Levels Description Combine red green blue and white to make a RED O GREN custom color 0 100 he str fr n 10 Automatic programs ADDR DMX mode SLAV Master Slave mode D 001 512 JSelects the DMX starting address 11 channel RGBW dimmer strobe color macro TOUR auto custom dimmer speed auto speed pixel selection 16 channel 16 bit RGBW dimmer strobe color TR16 macro auto custom dimmer speed auto speed pixel selection ARC 1 3 channel RGB control 4 channel RGB dimmer ARC 2 4 channel RGBW control 8 20 9 5chamel RGBW dimmer 5 chamei RGBW dimmer strobe PSV Sien HSV contro PIX1 12 channel RGB pixel control PIX2 16 channel RGB W pixel control HALO 4 channel 2700 K pixel control GREN Combi
8. 10 Preset dimmer speed from display menu Linear dimmer Nonlinear dimming curve 1 fastest Nonlinear dimming curve 2 Nonlinear dimming curve 3 Nonlinear dimming curve 4 slowest Pix 1 2 3 4 static Pix 1 static Pix 2 static Pix 3 static Pix 4 static Pix 1 2 static Pix 1 3 static Pix 1 4 static Pix 2 3 static Pix 2 4 static Pix 3 4 static Pix 1 2 3 static Pix 1 2 4 static Pix 1 3 4 static Pix 2 3 4 static Pix 1 2 3 4 static Chase left to right Chase right to left Chase left right left Random Pix 1 2 3 4 static Colorado 4 IP User Manual Rev 5 1101 FESSIO NAL Operation DMX Values Continued TR16 Channel Function Value Percent Setting Dimmer Lon 255 0 100 2 Fine Dimmer 0000 255 0 100 3 Red 0000 255 0 100 4 000 255 0 100 5 Green 0000 255 0 100 6 Fine Green 0000 255 0 100 7 Blue 0000 255 0 100 9 000 255 0 100 10 Fine White 000 255 0 100 000 010 No Function 011 U 030 IR 100 G 100 B 0 031 U 050 R 100 0 G 100 B 0 051 U 070 R 0 G 100 B 0 100 071 U 090 R 0 G 100 0 B 100 091 U 110 IR 0 100 G 0 B 100 111 U 130 IR 100 G 0 B 100 0 131 U 150 R 100 G 100 B 100 151 U 170 R 100 0 G 100 0 100 171 U 200 IR 100 G 100 B 100 W 100 11 Color Macro White 2010 205 White 1 206 210 White 2 2110 215 White 3 2160 220 White
9. 4 2210 225 White 5 226 0 230 White 6 231 235 White 7 236 0 240 White 8 241 245 White 9 246 0 250 White 10 251 255 White 11 Colorado 4 IP User Manual Rev 5 19 Operation DMX Values Continued TR16 Channel Function Cont 12 Classic Strobe 13 Programs 20 No function Slow to fast No function Lighting effect slow to fast No function No function 19 Hz 20 Hz No Function Auto 1 Auto 2 Auto 3 Auto 4 Auto 5 Auto 6 Auto 7 Auto 8 Auto 9 Auto 10 Custom 1 Custom 2 Custom 3 Custom 4 Custom 5 Custom 6 Custom 7 Custom 8 Custom 9 Custom 10 Percent Setting Select strobe function in the main menu under SET STRB Colorado 4 IP User Manual Rev 5 CHAUVET FESSIONAL Function Value Operation Percent Setting Auto Speed 000 U 255 0 100 Only when using Auto Custom Dimmer Speed Linear d DMX Values Continued TR16 Channel Cont 14 15 16 ARC 1 Channel 1 2 3 AR1 D Channel 1 2 3 4 ARC 2 Channel 1 2 3 4 Colorado 4 IP User Manual Rev 5 Preset dimmer speed from display menu immer Nonlinear dimming curve 1 fastest Nonlinear dimming curve 2 Nonlinear dimming curve 3 Nonlinear dimming curve 4 slowest Pixel Selection 000 009 Pix 1 2 3 4 static 010 U 019 Pix 1 static 020 U 029 Pix 2 static 030 039 Pix 3 static 040 049 Pix 4 static 050 U 059 Pix 1 2 060 069 Pix 1 3
10. COtORapo 4 User Manual d PROFESSIONAL Edition Notes Edition Notes Trademarks Copyright Notice Manual Use Document Printing Intended Audience Disclaimer Document Revision v du PROFES amp El a NAL The COLORado 4 IP User Manual Rev 5 covers the description safety precautions installation programming operation and maintenance of the COLORado 4 IP Chauvet released this edition of the COLORado 4 IP User Manual in April 2015 CHAUVETO is a registered trademark of CHAUVET amp Sons Inc d b a CHAUVET or Chauvet The CHAUVETO logo in its entirety including the CHAUVET name and the dotted triangle and all other trademarks in this manual pertaining to services products or marketing statements are owned or licensed by Chauvet Any other product names logos brands company names and other trademarks featured or referred to within this document are the property of their respective trademark holders Chauvet owns the content of this User Manual in its entirety including but not limited to pictures logos trademarks and resources O Copyright 2015 Chauvet All rights reserved Electronically published by Chauvet in the United States of America Chauvet authorizes its customers to download and print this manual for professional information purposes only Chauvet expressly prohibits the usage copy storage distribution modification or printing of this manual or
11. Master Slave operation The DMX controller may interfere with signals from the master product The master product should be the first product in the daisy chain The COLOR setting determines how the COLORado 4 IP generates the white color based on various RGB settings 1 Goto the SET main level 2 Select COLO 3 Select OFF RGBW or UC OFF When all the RGB faders are set to 255 the output is maximum although the resulting white color may not be balanced RGBW When all the RGB faders are set to 255 the resulting output is defined by the configured white color see White Calibration UC When all the RGB faders are set to 255 the output matches that of less efficient products Universal Color Operation Dimmer Curves Curve Settings D Control Panel Lock Passcode Settings Lock Out v II PROFESSIONAL This setting determines how fast the output of the COLORado 4 IP changes when you modify the values of the Red Green Blue White and Dimmer faders This setting provides four different options to simulate the dimming speed of an incandescent lighting product 1 Goto the SET main level 2 Select DIMX 3 Select a dimmer curve OFF DIM1 DIM2 DIM3 or DIMA4 OFF The output is proportional linear to the Dimmer and RGBW channel values DIM1 4 The output follows the Dimmer and RGBW channel values based on the corresponding dimmer speed being DIM1 the fastest and DIM4 the slowest This
12. PROFESSIONAL 5 Technical Information 24 Product Maintenance D Returns To maintain optimum performance and minimize wear you should clean this product frequently Usage and environment are contributing factors in determining the cleaning frequency As a rule clean this product at least twice a month Dust build up reduces light output performance and can cause overheating This can lead to reduced light source life and increased mechanical wear To clean your product Unplug the product from power Wait until the product is at room temperature Use a vacuum or dry compressed air and a soft brush to remove dust collected on the external vents Clean all external surfaces with a mild solution of non ammonia glass cleaner or isopropyl alcohol Apply the solution directly to a soft lint free cotton cloth or a lens cleaning tissue Wipe any dirt or grime to the outside edges of the lens surface Gently polish the lens surfaces until they are free of haze and lint Always dry the external surfaces thoroughly and carefully after cleaning them You must send the product prepaid in the original box and with the original packing and accessories Chauvet will not issue call tags Call Chauvet and request a Return Merchandise Authorization RMA number before shipping the product Be prepared to provide the model number serial number and a brief description of the cause s for the return Clearly label the package with
13. personality setting In this mode each product will respond to a unique starting address from the DMX controller All products with the same starting address will respond in unison 1 Select a DMX personality as shown in DMX Personality 2 Set the running mode a Goto the RUN main level b Select the ADDR programming level 3 Set the starting address a Goto DMX main level b Select the starting address D 001 512 The highest recommended starting address for each DMX mode is as follows DMX DMX DMX DMX DMX DMX Mode Address Mode Address Mode Address TOUR 510 TRI6 497 20 508 PIXI 501 ARC 1 510 AR2S 507 PIX 497 AR1 D 909 HALO 909 This setting controls how the product will respond when the DMX signal is lost 1 Goto the SET main level then select DERR a Select SAVE to make the product use the last command used when the signal is lost b Select BLAK to turn off the all the LEDs when the signal is lost The Static Color mode allows for RGBW color mixing without a DMX controller Go to the STAT main level Select the desired color RED GREN BLUE or WHIT Select the desired color value 000 255 Repeat for the other colors Select STRB Select the desired frequency 00 20 Or Wr Du x Colorado 4 IP User Manual Rev 5 Auto Programs Edit Customs Master Slave Color Settings Colorado 4 IP User Manual Rev 5 Operation Auto programs allow for dynami
14. BA General Information Technical Support Address Stokstraat 18 Email Eutech chauvetlighting eu 9770 Kruishoutem Belgium World Wide Web www chauvetlighting eu Voice 32 9 388 93 97 Outside the U S United Kingdom lreland Mexico or Benelux contact the dealer of record Follow their instructions to request support or to return a product Visit our website for contact details RoHS UL 1573 O CSAC22 2 No 166 115 E113093 COLORado 4 IP User Manual Rev 5
15. ED Lifespan DMX Master Slave CHAVYET PROFESSIONAL Auto Programs Auto Ranging Power Supply X U UU User Serviceable Read all the following Safety Notes before working with this product These notes include important information about the installation usage and maintenance of this product This product contains no user serviceable parts Any reference to servicing in this User Manual applies to properly trained Chauvet certified technicians Do not open the housing or attempt any repairs All applicable local codes and regulations apply to the proper installation of this product Avoid direct eye exposure to the light source while the product is on Always disconnect this product from its power source before servicing Always connect this product to a grounded circuit to avoid the risk of electrocution Do not touch this product s housing during operation because it may be very hot The product is not intended for permanent installation DO NOT submerge this product IP66 Regular outdoor operation is fine CAUTION When transferring product from extreme temperature environments e g cold truck to warm humid ballroom condensation may form on the internal electronics of the product To avoid causing a failure allow product to fully acclimate to the surrounding environment before connecting it to power Make sure there are no flammable materials close to this product while it is operating When hanging this pr
16. W 1 89 A 5 products T 5A 250 V U S Canada Hardwired IP66 Edison U S Power 40 W Quantity 4 Installed Optics 15 3 600 lux 129 26 0 20 Hz Cooling System Convection Connector Type Sockets ltem Code 01030648 Height 8 7 in 221 mm Technical Information Weight 22 4 lb 10 16 kg Voltage Selection Auto ranging 230 V 50 Hz 216 W 0 94 A 10 producis T5A 250V Worldwide Hardwired IP66 Local plug Lifespan 50 000 hours Current 1 000 A Channel Range 3 4 5 6 11 120r 16 UPC Number 781462209964 25 WORLD HEADQUARTERS Chauvet Contact Us General Information Technical Support Address 5200 NW 108th Avenue Voice 954 577 4455 Press 4 Sunrise FL 33351 Fax 954 756 8015 Voice 854 577 4455 Email tech chauvetlighting com Fax 954 929 5560 Toll free 800 762 1084 World Wide Web www chauvetlighting com UNITED KINGDOM AND IRELAND Chauvet Europe Ltd General Information Technical Support Address Unit 1C Email uktech chauvetlighting com Brookhill Road Industrial Estate Pinxton Nottingham UK World Wide Web www chauvetlighting co uk NG16 6NT Voice 44 0 1773 511115 Fax 44 0 1773 511110 MEXICO Chauvet Mexico General Information Technical Support Address Av Santa Ana 30 Email servicio chauvet com mx Parque Industrial Lerma Lerma Mexico C P 52000 World Wide Web www chauvet com mx Voice 52 728 285 5000 CHAUVET EUROPE Chauvet Europe BV
17. an RMA number Chauvet will refuse any product returned without an RMA number DO NOT write the RMA number directly on the box Instead write it on a properly affixed label Once you have received the RMA number include the following information on a piece of paper inside the box Your name Your address Your phone number The RMA number A brief description of the problem s Be sure to pack the product properly Any shipping damage resulting from inadequate packaging will be the customer s responsibility FedEx packing or double boxing are recommended Chauvet reserves the right to use its own discretion to repair or replace returned product s Colorado 4 IP User Manual Rev 5 nit E HAL Technical Specifications Dimensions and Weight Electrical Light Source Photometrics Thermal DMX Ordering Length 22 in 560 mm Power Supply Type Switching internal Parameter Consumption Operating Inrush current Power linking Fuse Power UO Power input connector Power output connector Power cord plug Type LED Color Quad color RGBW Parameter Illuminance O 5 m Beam angle Field angle otrobe rate Max External Temperature 113 F 45 C I O Connectors 5 pin XLR Product COLORado 4 IP Colorado 4 IP User Manual Rev 5 Width 5 4 in 138 mm Note Dimensions in inches rounded to the nearest decimal digit Range 100 to 240 VAC 50 60 Hz 120 V 60 Hz 222
18. c RGBW color mixing without a DMX controller 1 Goto AUTO 2 Select the desired auto AT 01 10 or custom program PR 01 10 You cannot edit any of the auto programs AUTO 01 10 However you can edit the custom programs PR 01 10 See Edit Customs below for details This setting allows the programming of up to 30 scenes for each of the 10 customizable programs including colors and effects 1 Goto the EDIT main level Select the desired auto program PR 01 10 Select the desired scene SC 01 30 Select the desired color or effect RED GREN BLUE WHIT STRB TIME or FADE Select the color or effect value 000 255 for colors and timers or 00 20 for strobe Repeat for the other colors or effects Return to the scene SC 01 30 level Repeat the settings of colors and effects for the other scenes ee I ND The Master Slave mode allows a group of COLORado 4 IPs the slave products to simultaneously duplicate the output of another COLORado 4 IP the master product without a DMX controller 1 Set each of the slave products a Goto RUN b Select SLAVE 2 Set the master product a Set the running mode to DMX as explained in DMX Control b Select an auto or custom program as explained in Auto Programs above or a static mix of colors The master product is the one that runs a program whether in Auto Custom or Static Color mode Do not connect a DMX controller to the products configured for
19. cent Setting 2 Red 0000 25 On 3 Grem 0000 255 0 100 4 Blue 0000 255 0 100 5 000 255 0 100 No function H 100 G 0 100 B 0 R 100 0 G 100 B 0 R 0 G 100 B 0 100 R 0 G 100 0 B 100 R 0 100 G 0 B 100 R 100 G 0 B 10096 0 H 100 G 0 100 8 0 100956 R 100 0 G 100 0 8 100 Color Macro White R 100 G 100 B 100 W 100 6 White 1 Balance White 4 White 5 White 6 White 7 White 8 White 9 White 10 White 1 1 No function Slow to fast No function Lighting effect slow to fast Sel No function Select strobe 000 U 009 No function function in 010U 019 1 Hz 0200 029 2Hz 030 U 039 3 Hz 0400 049 4 Hz SET gt STRB 050U 059 5 Hz 060 069 6 Hz 7 070 079 7 Hz 080 U 089 8 Hz 090 U 099 9 Hz Classic Strobe 100 U 109 10 Hz 1100 119 11 Hz 1200 129 12 Hz 130 U 139 13 Hz 1400 149 14 Hz 150U 159 15 Hz 160U 169 16 Hz 1700 179 17 Hz 180U 189 18 Hz 190U 199 19 Hz 200 U 255 20 Hz the main menu under Colorado 4 IP User Manual Rev 5 17 Operation DMX Values Continued TOUR Cont Channel Function 8 Programs 10 Dimmer Speed 000 U 11 Pixel Selection 159 179 199 J 219 7 239 240 255 18 Percent Setting No function Auto 1 Auto 2 Auto 3 Auto 4 Auto 5 Auto 6 Auto 7 Auto 8 Auto 9 Auto 10 Custom 1 Custom 2 Custom 3 Custom 4 Custom 5 Custom 6 Custom 7 Custom 8 Custom 9 Custom
20. e 000 255 0 100 PIX1 Channel Function Value 1 Pixel 1 Red 000 255 0 100 2 Pixel 1 Green 000 255 0 100 3 Pixel 1 Blue 000 255 0 100 4 Pixel 2 Red 000 255 0 100 5 Pixel 2 Green 000 255 0 100 6 Pixel 2 Blue 000 255 0 100 7 Pixel 3 Red 000 255 0 100 8 Pixel 3 Green 000 255 0 100 9 Pixel 3 Blue 000 255 0 100 10 Pixel 4 Red 000 255 0 100 11 Pixel 4 Green 000 255 0 100 12 Pixel 4 Blue 000 255 0 100 90 Percent Setting Percent Setting Percent Setting Colorado 4 IP User Manual Rev 5 CHAUVET FESSIONAL DMX Values Continued PIX2 Channel mb alol OINI OJO CC 3 h sch sch amp N HALO Channel MM AR2 D Channel amp NN Colorado 4 IP User Manual Rev 5 Function Value 000 255 0 100 000 255 0 100 000 255 0 100 000 255 0 100 000 255 0 100 000 255 0 100 Pixel 4 White 000 255 0 100 Function Value Pixel 1 Dimmer 2700K 000 U 255 0 100 Pixel 2 Dimmer 2700K 000 U 255 0 100 Pixel 3 Dimmer 2700K 000 U 255 0 100 Pixel 4 Dimmer 2700K 000 U 255 0 100 Function Value Dimmer 0000 255 0 100 Red 0000 255 Jo 100 Green 0000 255 0 100 Bue 0000 255 0 100 White 000 255 0 100 Percent Setting Percent Setting Percent Setting Operation 23 Technical Information v CHAUVET
21. eed to change the Edison plug use the table below to wire the new plug Connection Wire U S Wire Europe Screw Color AC Live Brown Yellow or Brass AC Neutra Silver AC Ground Green Yellow Green Yellow Green Colorado 4 IP User Manual Rev 5 Power Linking DMX Linking DMX Personalities Master Slave Connectivity MELO Colorado 4 IP User Manual Rev 5 Setup The COLORado 4 IP supports power linking You can power link up to 5 products at 120 VAC 9 products at 208 VAC or 10 products at 230 VAC This product comes with a power input cord This product does not come with a power linking cable however a power linking cable is available as an option You can link the COLORado 4 IP to a DMX controller using a standard DMX serial connection If using other DMX compatible products with the COLORado 4 IP you can control each individually with a single DMX controller The COLORado 4 IP uses the standard DMX data connection for the TOUR TR16 ARC 1 AR1 D ARC 2 AR2 D AR2 S HALO PIX1 PIX2 and HSV DMX personalities Refer to the Introduction for a brief description of these modes Refer to Operation to learn how to configure the COLORado 4 IP to work in these modes The DMX Values section will provide you with detailed information regarding the DMX modes The Master Slave mode allows a COLORado 4 IP the master to control one or more COLORado 4 IPs the slaves without a DMX controller
22. its content for any other purpose without written consent from Chauvet For better results print this document in color on letter size paper 8 5 x 11 in double sided If using A4 paper 210 x 297 mm configure your printer to scale the content accordingly Any person in charge of installing operating and or maintaining this product should completely read through the guide that shipped with the product as well as this manual before installing operating or maintaining this product Chauvet believes that the information contained in this manual is accurate in all respects However Chauvet assumes no responsibility for any errors or omissions in this document Chauvet reserves the right to revise and make changes to the content of this document without obligation that Chauvet notify any person or company of such revision or changes This does not in any way constitute a commitment by Chauvet to make such changes Chauvet may issue a revision of this manual or a new edition to incorporate such changes The COLORado 4 IP User Manual Rev 5 supersedes all previous versions of this manual Discard any older versions of this manual and replace with this version Author Date Editor Date D Couppe 3 30 15 M Trouard 04 21 15 Colorado 4 IP User Manual Rev 5 Tableof Contents Table of Contents _ _ _ _3_______ lt _ lt ____ ______________ ___ __ _ 1 Eege 1
23. l Rev 5 Program Upload This option allows you to copy the custom programs of one COLORado 4 IP onto other COLORado 4 IPs by using the Master Slave mode 1 Configure and connect the products in a Master Slave arrangement where the master product has the custom programs you want to transfer to the slave products From the master product go to the SET main level oelect UPLD When PASS shows press lt ENTER gt Enter the master access passcode as shown in Control Panel Lock When SEND shows press ENTER to start the upload Wait for the upload process to finish the display will show END before continuing or turning the products off Qi 9 pi dx T The Master Slave products will provide the status of the process by lighting up as follows Yellow indicates that the upload process is running Green indicates that the upload process completed successfully Red indicates that the upload process failed due to an error Recheck all cable connections and restart the process If the issue persists contact Chauvet Technical Support DO NOT upload the data from a COLORado 4 IP to a different product The other product may become inoperative Reset This setting allows you to reset the COLORado 4 IP to the default values including the custom programs 1 Goto the SET main level 2 Select REST 3 When PASS shows press ENTER 4 Enter the master access passcode as described in Control Panel Lock 5 Wait fo
24. llation When selecting an installation location consider easy access to this product for operation programming adjustments and routine maintenance Make sure to mount this product away from any flammable material as indicated in the Safety Notes If hanging this product make sure that the mounting location can support the product s weight Refer to the Technical Specifications for the weight bearing requirements of this product When hanging this product always secure to a fastening device using a safety cable Procedure The COLORado 4 IP comes with a multi purpose yoke to which you can either attach mounting clamps for hanging attach other COLORado 4 IP products horizontally or vertically or attach to the floor for use as a floor stand You must supply your own mounting clamps Make sure the clamps are capable of supporting the weight of this product Diagram 7 i mji CE Floor Mounting Overhead Mounting 8 Colorado 4 IP User Manual Rev 5 SSICMAL OF 4 Operation Control Panel Description Control Options Programming Colorado 4 IP User Manual Rev 5 Button MENU ENTER lt UP gt lt DOWN gt Operation Function Exits from the current menu or function Enables the currently displayed menu or sets the currently selected value in to the current function Navigates upward through the menu list and increases the numeric value when in a fu
25. mproving the ventilation around the product and reducing the ambient temperature to an optimal operating range In addition limiting the overall projection intensity may also help to extend the LEDs lifespan Colorado 4 IP User Manual Rev 5 2 Introduction Product Description Features Colorado 4 IP User Manual Rev 5 Introduction The COLORado 4 IP is a high power quad color RGBW LED linear wash product This product consists of four modules that house the internal power supply the main control the control panel the LED drivers the LED boards as well as the IP66 rated power and signal connectors 3 4 5 6 11 12 or 16 channel quad color LED linear wash product Operating modes 3 channel RGB control 3 channel HSV control 4 channel RGB dimmer 4 channel RGBW 4 channel 2700 K pixel control 5 channel RGBW dimmer 6 channel RGBW dimmer strobe 11 channel RGBW dimmer strobe macro auto custom dimmer speed auto speed pixel selection 12 channel R1 G1 B1 R2 G2 B2 R3 G3 B3 R4 G4 B4 16 channel 16 bit RGBW 16 bit dimmer macro strobe auto custom auto speed dimmer speed pixel selection 16 channel R1 G1 B1 W1 R2 G2 B2 W2 R3 G3 B3 W3 R4 G4 B4 W4 Silent operation Fantastic output with low profile footprint Stunning color mixing Pixel control of each LED IP66 rated suitable for outdoor operation introduction ET Overview Front View Control Panel
26. nction Navigates downward through the menu list and decreases the numeric value when in a function You can set the COLORado 4 IP start address in the 001 512 DMX range This enables control of up to 32 products in the 16 channel TR16 or PIX2 personality Refer to the Menu Map to understand the menu options The menu map shows the main level and a variable number of programming levels for each option To go to the desired main level press MENU repeatedly until the option shows on the display Press lt ENTER gt to select This will take you to the first programming level for that option To select an option or value within the current programming level press UP or lt DOWN gt until the option shows on the display Press ENTER to select In this case if there is another programming level you will see that first option or you will see the selected value Press MENU repeatedly to exit to the previous main level Operation DMX Personality DMX Control Loss of Signal Setting Static Color 41110 PROFESS AL i This setting allows you to choose a particular DMX personality 1 Goto the PERS main level 2 Select the desired personality TOUR TR16 ARC 1 AR1 D ARC 2 AR2 D AR2 S PIX1 PIX2 HALO or HSV See the DMX Values section for the highest starting address you can select for each personality Make sure that the starting addresses on the various products do not overlap due to the new
27. ne red green blue and white to generate BLUE a custom color 0 100 WHIT n a 0 Er STRB Selects the strobe frequency 0 20 Hz TIME Defines the step duration 0 slow to fast 255 i FADE Defines the fade duration slow to fast Colorado 4 IP User Manual Rev 5 15 PROFESSIONAL Menu Map Continued Main Level Programming Levels Description E n the passcode on or off ee SEND Uploads custom programs to other END COLORado 4 IP Passcode PASS REST Enter Passcode Defaults product to factory settings ame sa RGB set to 255 max output COLO RGBW RGB set to 255 balanced white Universal color balance OFF M UPLD omx om SET 088 3 Fast DIM1 to slow DIMA dimmer speeds V1 CV2 Large CV3 to small CV1 dimmer curves SAVE Continues with last command upon loss of DMX control BLAK Blacks out fixture upon loss of DMX SLCK SET main level access lock am SPEC Selects strobe personality used in TOUR and Ex TR16 personalities CAL1 WH Modifies the color macros used in the TOUR and 01 11 EC TR16 personalities PASS E CAL Enter B S CAL2 Defines the color temperature used when COLO is set to RGBW BLUE _ DE ass CALR Enter Passcode Defaults CAL to factory settings Ae ColoradoTM4 IP User Manual Rev 5 Y CH El Operation FESSIO DMX Values TOUR Channel Function Value Per
28. oduct always secure to a fastening device using a safety cable Always make sure you are connecting this product to the proper voltage in accordance with the specifications in this manual or on the product s specification label Never connect this product to a dimmer pack or rheostat Never disconnect this product by pulling or tugging on the power cable Do not operate this product if you see damage on the housing lenses or cables Have the damaged parts replaced by an authorized technician at once To eliminate unnecessary wear and improve its lifespan during periods of non use completely disconnect the product from power via breaker or by unplugging it Do not cover the ventilation slots when operating to avoid internal overheating The maximum ambient temperature is 104 F 40 C Do not operate this product at a higher temperature In case of a serious operating problem stop using this product immediately In the unlikely event that your Chauvet product may require service contact Chauvet Technical Support LEDs gradually decline in brightness over time mostly because of heat Packaged in clusters LEDs exhibit higher operating temperatures than in ideal single LED conditions For this reason using clustered LEDs at their fullest intensity significantly reduces the LEDs lifespan Under normal conditions this lifespan can be 40 000 to 50 000 hours If extending this lifespan is vital lower the operating temperature by i
29. r the reset process to finish Calibration Settings This setting allows you to reset the COLORado 4 IP to the default values of the color Reset macros in Whites Setting or Whites Calibration Go to the CAL main level When PASS shows press ENTER Enter the master access passcode as described in Control Panel Lock Go to CALR When PASS shows press ENTER Enter the master access passcode as described in Control Panel Lock O Pl Ur Ie e Colorado 4 IP User Manual Rev 5 13 Operation Whites Setting White Calibration Strobe Personality v 1111 PROFESSIONAL This setting allows you to select and edit the temperature of the white colors used in channel 6 Macros when in the TOUR mode or channel 11 in TR16 mode Go to the CAL main level Enter the master access passcode as described in Control Panel Lock Go to CAL1 Select a white color WH 01 11 Select a color RED GREN BLUE or WHIT Select a color value 000 255 7 Repeat for the other colors This setting allows you to select the white color shown by the COLORado 4 IP when the color setting is RGBW and the DMX controllers Red Green and Blue faders are set to 255 1 Gotothe CAL main level Enter the master access passcode as described in Control Panel Lock Go to CAL2 Select a color RED GREN or BLUE Select a color value 000 255 6 Repeat for the other colors When selecting CAL gt CAL2
30. setting determines the shape of the output curve of the COLORado 4 IP when you modify the values of the Red Green Blue White and Dimmer faders This setting provides three different options to simulate the dimming curve of an incandescent lighting product 1 Goto the SET main level 2 Select CURV 3 Select a dimmer curve OFF CV1 CV2 or CV3 OFF This output is proportional linear to the Dimmer and RGBW channel values CV1 3 This output follows the Dimmer and RGBW channel values based on the corresponding dimmer curve being CV1 the fastest and CV3 the slowest For optimum control of the 16 bit dimming channels in the TR16 personality be sure that both dimming curves in SET DIMX and SET CURV are set to OFF This setting enables you to activate or disable the control panel lock which keeps unauthorized personnel from changing the product s settings 1 20 10 the SET main level 2 Select KEY 3 Select ON or OFF When the control panel lock is active the product will prompt you to enter the passcode after 30 seconds of control panel inactivity or after turning on the product After being prompted to enter the passcode Press UP DOWN UP DOWN ENTER This setting enables you to activate or disable the main level SET settings lock which keeps unauthorized personnel from changing the product s settings 1 Goto the SET main level 2 Select SLCK 3 Select ON or OFF Colorado 4 IP User Manua
31. the carrier immediately may invalidate your claim In addition keep the box and contents for inspection For other issues such as missing components or parts damage not related to shipping or concealed damage file a claim with Chauvet within 7 days of delivery Manual Conventions Convention Meaning 1 512 A range of values in the text 50 60 A set of mutually exclusive values in the text SET A button on the product s control panel Settings A product function or a menu option MENU gt Settings A sequence of menu options 1 10 A range of menu values from which to choose in a menu Yes No A set of two mutually exclusive menu options in a menu ON A unique value to be entered or selected in a menu Symbols Symbols Meaning Critical installation configuration or operation information T Failure to comply with this information may cause the product not to work damage third party equipment or cause harm to the operator Important installation or configuration information Failure to comply with this information may keep the product from working Sr Useful information 4 The term DMX used throughout this manual refers to the USITT DMX512 A 1 digital data transmission protocol Colorado 4 IP User Manual Rev 5 A Before You Begin Product at a Glance Use on Dimmer Outdoor Use X Sound Activated Replaceable Fuse B Safety Notes D Personal Safety Mounting and Rigging Power and Wiring Operation Expected L

Download Pdf Manuals

image

Related Search

Related Contents

avertissement    Minox CD 112 Instruction Manual  Sioux Tools 5562 User's Manual  ダウンロード - グラフテック  取扱説明書 - 株式会社 P・マインド  3M Graphic Film Controltac HP 881 Latex Ink  Questionable Alignment Readings using an Imaging System  取扱説明書 [PDF形式]  取扱説明書 - Changer & Dresser Corp.  

Copyright © All rights reserved.
Failed to retrieve file