UPSilon 2000 Windows User`s Manual

image

Contents

1. UPSilon 2000 1 SIMPLE INSTALLATION Windows 95 98 NT 2000 ME XP e Hardware Installation see p3 1 Connect UPSilon 2000 cable to UPS communication port 2 Connect UPSilon 2000 cable to RS 232 port of PC 3 USB solution is optional offer Whenever use USB interface only MegaTec specific USB cable useable Contact our service center for details e Software Installation see p5 1 Insert UPSilon 2000 CD to the CD ROM UPSilon 2000 will display the installation menu or your can select run from windows start menu and execute setup exe UPSilon 2000 files will be copied into the directory you appointed Default C Program Files Megatec UPSilon 2000 2 Select language when install If you want to change language uninstall UPSilon and reinstall again for new selection 3 After installation For Windows 95 98 check if there is a Rupsmon Daemon icon in task bar For Windows NT go to control panel gt service and check if Rupsmon service has started see p6 4 Click UPSilon 2000 for Windows for parameter settings see p7 5 Click Select UPS to monitor local or remote UPS see p8 6 Click Settings to set Communication Type and Select Comm Port If Communication with UPS on the main screen this means you have connected with UPS see p9 For More Parameters Please Reference Other Topics UPSilon 2000 1 SIMPLE INSTALLATION NOVELL NETWARE V3 1X V4 X
2. 77 F 4 3 2 UPS Status z 2596 SCH BATTERY LEVEL Output Volt 125 0 VAC Display Area Line Freq 59 Hz 15 30 45 5 A 2 Batt Status Normal 4 3 3 Bar Chart VOLT CONDITION LINE UPS Testing Normal I 109 00 UPS Type ON Line Display Area L d L 4 Serial Port COM2 70 80 90 100 110 120 130 V Comm Status Connect F1 HELP F10 MENU ESC EXIT 4 2 2 File Descriptions File Descriptions of UPSilon for NetWare UPSilon NLM UPSilon for NetWare execution program UPSilon LOG UPS status history file UPSilon SCH Schedule ON OFF time configuration file UPSilon PRN UPS data analysis file this file could be operated with LOTUS or EXCEL for UPS status analysis UPSilon CFG UPSilon for NetWare configuration file Installation program will copy these files into the sub directory of SYS SYSTEM UPSilon 2000 23 NetWare Main Screen Description 4 3 Main Screen Description 4 3 1 Schedule Display Area Input AC Power Normal Battery Low Next Shutdown Time 04 07 1999 18 30 Next Startup Time 4 8871999 07 30 24 e Input AC Power Status of AC power when AC power failed UPS will start to supply the power to system UPSilon will broadcast the warning message of AC power failure to all the workstations This will also show the system shutdown countdown UPSilon will make all the workstations off line if AC power has not r
3. V5 X e Hardware Installation see p3 1 Connect male connector of UPSilon 2000 cable to UPS communication port 2 Connect female connector of UPSilon 2000 cable to RS 232 communication port of system If there is only a 25 pin RS 232 connector you can use the 9 pin to 25 pin adapter to convert it e Software Installation see p22 1 Login the file server as a SUPERVISOR or a user with access rights in sub directory SYS SYSTEM F gt LOGIN SUPERVISOR 2 Put the UPSilon CD in CD ROM 3 Execute INSTALL EXE in CD ROM A gt INSTALL 4 After installation please shutdown NetWare operating system and restart again The system will load the UPSilon NLM and execute it 5 When UPSilon for NetWare has been loaded server screen shows the successful loading message You could switch to the UPSilon with key ALT ESC 6 After installation if Connect is showed at Comm Status it means you have connection with UPS 7 If you have more than one com port on your File Server please insert two or more LOAD AIOCOMX command in the system AUTOEXEC NCF file after UPSilon 2000 installation For More Parameters Please Reference Other Topics 2 UPSilon 2000 CONTENTS FElntreaoadpetton es 1 1 1 PACKING INCLUDING v teea ee E E eE AE ESE E Ee 1 1 2 SYSTEM REOUIREMENTg 2 2 Hardware Installation cccesessessscvcvcesesessesssssceces 3 3 UPSilon 2000 for Windows esssessssseseccocsosscescocoossesseceo
4. Command File to Execute Set the file name to be executed before the system shutdown the full path and filename given Attention If the program which you execute can not quit automatically you would not be able to shutdown Windows and turn off UPS e Auto Save Application Files Configure auto saving all the opened applications and files before the system shut down If not given filename UPSilon will auto save in TMP e g Wnnnn TMP Check the closed filename in Close Files Record in function menu Attention UPSilon will try to close general applications and store files by artificial intelligence mode but UPSilon can not ensure that all the applicable software will be stored normally Shut Down Operating System Set to shut down it s own operating system e Turn Off UPS Set to turn off the UPS power supply Attention After shutting down system and turning off UPS please do not cut the power supply Otherwise UPS UPSilon 2000 1l Windows Functions 12 and computer would fail to start automatically when AC power restores Display Closed Files Record on UPSilon Restart Display the closed record on UPSilon restart if the auto saving function was set before closing the computer Shown as below Closed Files Record Closed Applications ThorBrowserWindClass Files Saved As Broadcast Settings Enable Pop Up Warnings The users can set whether or not appear the pop up warning on the scree
5. Q ee STARTED 03 26 1999 21 30 00 Shutdown File Server Schedule 03 27 1999 00 42 34 x UPSilon U2 Q ee STARTED 03 27 1999 00 42 53 x EXIT UPSilon xxx 03 27 1999 00 42 58 x UPSilon U2 0 zez STARTED 03 27 1999 00 46 16 EXIT UPSilon xxx 03 27 1999 01 00 47 x UPSilon U2 0 ee STARTED 03 27 1999 01 01 15 ees EXIT UPSilon xxx 03 29 1999 10 57 17 x UPSilon U2 0 zez STARTED 03 29 1999 10 57 26 e EXIT UPSilon ses 0342971999 11 51 33 x UPSilon U2 0 x STARTED 38 03 29 1999 11 51 41 en EXIT UPSilon 03 29 1999 16 56 31 ees UPSilon U2 0 see STARTED NetWare Main Menu Functions 4 5 Broadcast Messages When any power condition is detected file server will broadcast messages to workstations Here are the messages below lt WARNING gt AC POWER FAIL FS1 Shutdown in 10 min UPSilon detects AC fail start shutdown countdown lt Attention gt FS1 will Shutdown in 1 minutes Shut down warning of the last one minute FS1 AC Power restored Server won t be Shutdown UPSilon detects AC power restored and the server won t be shut down lt Attention gt UPS BATTERY LOW FS1 Shut down in 1 min UPSilon detects UPS battery low and the server will be shut down in one minute Battery Low Recovered Server won t be Shutdown UPSilon detects UPS battery power low restored and the server won t be shut down Battery Low Recovered Server Shutdown in 2 min UPS battery power low restored
6. Shut Doan Setup SNND Ska t Doan UPS Test Until Batt Low UPS 10sec Test UPS uto Test View History File View Log File 4 4 1 Configuration Configuration Tim Between AC Poser Fail ard initial warning message 5 Delay of Shuldom Server shen IC Power Failed Hin Delay Betucen Warning Message lt Delay of Shutdown Server ehan Hattery Low Hin furalion of OFS Auto Testing Hin Communication Serial Port Time of History fecording 1 Min Period of UPS uto Testing 3 Wach Hal tery Zel bg Se 28 Moi le Panaria in SIS E mail uf in Time Between AC Power Fail and initial warning message 28 UPSilon 2000 NetWare Main Menu Functions This option sets the delay time between AC power failure and initial warning message to all the workstations Sometimes the AC line power has a surge or temporary unstable voltage input and this setting will prevent this situation Therefore we set this delay time to make sure there is actually an AC power fail happened before we send out the warning message setting range 5 32 seconds default value 10 seconds e Delay of Shutdown Server when AC Power Failed This option sets the delay time between AC power fail and server shutdown When line power failed the UPS will supply the system with power The setting value should be smaller than the length of the time which the UPS supply setting range 2 999 minutes default value 10 minutes Attenti
7. U A 26 4 4 MAIN MENU FONCTION 28 4 401 Configuration suis sss ua a ud 28 4 4 2 Configure E mail ieis imis sas mkenis aha 33 4 4 3 Configure Poger EE E T EE 33 4 4 4 Schedule Ahutdown 34 4 4 3 Setup AN ee 35 4 4 6 Shutdown UPS ee arine aaia TVEAT ES EARI OETA 36 4 4 7 Test Until Batt Low 37 4 4 8 UPS Jee Testerenin ined opea teens 37 44 9 UPS Auto Testinin usi ius 38 4 4 10 View History File 38 BATT View Fogbhilesss sus sss ns 38 4 5 BROADCAST MESSAGES ss eeeseseeseeneeseetesets 39 4 6 SHUTDOWN PROCEDURE usseeseeeeeeseeeeseense neeese 40 UPSilon 2000 1 1 Introduction Introduction UPSilon 2000 is a smart UPS monitoring and controlling software UPSilon displays the status of UPS e g input amp output voltage line frequency load temperature and battery capacity in digital and graphic which can help the users monitor the quality of power supply Simultaneously the users can remotely monitor UPS via network and manage the power more effectively On AC failure or UPS battery low UPSilon 2000 will perform its monitoring function without people around UPSilon 2000 has some new ways to send the warning messages auto dialing and by E mail In addition UPSilon 2000 has a new Windows NT service function which allows the monitoring program to be executed automatically before log in UPSilon is available in many languages you can select the one that is most familiar for you to c
8. but AC power still failed UPSilon 2000 39 NetWare Shutdown Procedure 4 6 Shutdown Procedure 40 When an AC Failure or Battery Low occurs or execute the Scheduled ShutDown or Shutdown UPS function in Main Menu UPSilon will execute shutdown procedures If you want to execute a command file before system shutdown please create the file and save it as RUPSDOWN NCF in SYS SYSTEM When execute shutdown procedures UPSilon will execute RUPSDOWN NCF first if this file has been created The time needed for executing RUPSDOWN NCF can be set in Duration of UPS Auto Testing in Configuration See P30 for details of these settings UPSilon 2000 NetWare Shutdown Procedure IMUL 331 02 UPSilon 2000 User s Manual Copyright O Mega System Technologies Inc 2000 Rev 2 01E UPSilon 2000 41
9. introduction UPSilon Uninstall Remove UPSilon from Windows system 3 4 Functions After entering UPSilon a functional chart displays as below Ta Meter Digital Block chart Select UPS eg Function UPS Selection Dynamic Area Display Schedule Data Log Bity Bad UPS A I UPS Manufacturer Ol On Battery ee Status Event Log Commence Countdown 00 01 32 UPS Version HOZEZCIO Area 1999 05 26 09 55 24 UPS Connected 1999 05 26 09 53 32 UPS Connected l 999 05 26 09 56 47 Power Fail 3 4 1 UPS dynamic display area This area displays some relevant information of the UPS Users could select different display mode such as meter digital block and chart The information includes input voltage output voltage line frequency battery capacity load temperature etc UPSilon 2000 7 Windows Functions 3 4 2 UPS Status Area After the UPSilon software installed check whether the UPS is connected to the computer AC power is in normal status of UPS power supply and some relevant information of the UPS 3 4 3 Function selection area After a successful installation you can start to configure the parameter value Each parameter value will affect the normal operation of the UPSilon program Please configure the parameter value of the different function options according to the following chapter 3 4 3 1Select UPS Configure UPSilon Monitor local UPS or Monitor remote UPS The met
10. lim M i Beni Fiori Tima AJN DEA gl US Bieles maid ne LIPA eo ln Bai marki Pemarah e Daimi Walt HE 9 Sp 92 woe wm mm Lore Ire ba Bia E lU DA amp MI RI Bang Elalaa ermal Lg ium IR RI E tee TT a m itt Un kan 4 4 6 Shutdown UPS Shut down the file server and turn off UPS immediately If there is any users on the network with opening files the system will show a warning message and ask for confirmation 36 UPSilon 2000 NetWare Main Menu Functions to shut down file server If manager select YES the system will enforce the user to disconnect from network then shut down file server and UPS The UPS will be in sleeping state and wake up according to the system configuration Attention Do not use the DOMN command in the prompt In that case UPS will not be able to enter sleeping state and wake up automatically 4 4 7 Test Until Batt_Low This function makes the UPS to do a self testing of all functions The testing will last until UPS battery exhausted Execution mode press lt Enter gt in Main Menu for selecting Test until Bart Low and press Esc back to the main screen This Testing will be shown in bar of UPS Status In order to stop the test please go back to Main Menu and select Test until Batt_Low once again 4 4 8 UPS 10Sec Test This function would make the UPS to do a short testing This testing will last fo
11. 0v 59 0Hz 100 1999 05 27 14 5 1090w 123 0 59 0 Hz 100 1999 05 27 14 5 1090w 1250w 59 0Hz 100 96 1999 05 27 14 5 1090w 1250w 59 0 Hz 100 1999 05 27 14 5 1090w 1230v 59 0Hz 100 1999 05 27 14 5 1090w 1230w 59 0 Hz 100 96 UPSilon 2000 17 Windows Functions 3 4 3 5 Event Log You can check the date time and description of events in Event Log Shown as below 06 04 23 PM AC Failure 06 04 44 PM AC Power Restored 09 56 47 AM AC Failure 09 57 33 AM AC Power Restored 3 4 3 6History Calender In this section you can check the monthly event including AC fail battery low OS and UPS shutdown UPS self test etc Different color stands by different category press the block the specific date will be displayed in Power Events for Press PREV for last month event record Press NEXT for event record of the next month Press the button Exit for quitting 04 42 49 PM AC F 04 42 56 PM SELF TEST Si w 18 UPSilon 2000 Windows Functions 3 4 3 7 Control Command UPS directly for the following test Press control UPS Self Test for 10 Secs UPS Self Test n Mins UPS Self Test Until Battery Low Cancel UPS Self Test UPS Beep On Off the UPS supports command Q Shut Down Operating System and UPS vL gt 9 a trol koj UPS Self Testfor 10 Secs UPS Self Test 2 Mins ej UPS Self Test Until Battery Low Cancel UPS Self Test e UPS Beep On Off a Shut Down Oper
12. D MECA TEC UPSilon 2000 Uninterruptible Power Supply Software User s Manual For Microsoft Windows 95 Microsoft Windows 98 Microsoft Windows NT Microsoft Windows 2000 Microsoft Windows ME Microsoft Windows XP Novell Netware Linux FreeBSD COPYRIGHT ANNOUNCEMENT LIMITED WARRANTY THE PROGRAM AND ENCLOSED MATERIALS ARE PROVIDED AS IS WITHOUT WARRANTY OF ANY KIND EITHER EXPRESSED OR IMPLIED INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANT ABILITY AND FITNESS FOR A PARTICULAR PURPOSE THE ENTIRE RISK AS TO QUALITY AND PERFORMANCE OF THE PROGRAM AND ENCLOSED MATERIAL IS ASSUMED BY YOU LIMITATION OF REMEDIES Mega System Technologies Incorporation entire liability and your exclusion remedy shall be replacement of the media if you have met the conditions as described under Limited Warranty In no event will Mega System Technologies Incorporation be liable to you for any other damages arising out of your use of this program All mentioned trademarks are registered trademarks of their respective owners TECHNICAL SUPPORT UPSilon 2000 is developed by Mega System Technologies Inc If there is any question or comment about this product please feel free to contact us Mega System Technologies Inc Tel 886 2 87922060 Fax 886 2 87922066 E MAIL service megatec com tw FTP ftp ftp megatec com tw WWW http www megatec com tw Copyright 1999 2001 by Mega System Technologies Inc
13. ING In Novell NetWare printer setting PSERVER NLM do not select the RS 232 port for UPS communication UPSilon 2000 cable M2502 or M2505 is specially design Do not use any other RS 232 CABLES to connect UPS When select USB interface as communication port only Windows 95 98 NT 2000 ME workable UPSilon 2000 3 Windows Features 3 UPSilon 2000 for Windows 3 1 Features e Support Windows NT Service function e Support multiple shut down e Support multiple languages e Sending warning message by e mail automatically e Calling pager for the warning message automatically e Remote monitoring UPS via TCP IP or Internet e Detect AC fail and UPS battery low automatically Scheduling turn on off timing e Displaying the UPS status at graphic such as the temperature voltage load line frequency etc e Broadcasting warning message e Setting the countdown timing and the interval of each warning Setting UPS diagnostic and self test time e Before removing the system automatically close and store the applicable programs e Recording and analyzing the UPS status 4 UPSilon 2000 Windows Functions 3 2 Software Installation The SETUP program is required for UPSilon installation After installation the files will be copied to the MegaTec UPSilon 2000 directory Following the steps below 1 Turn on UPS and PC 2 Place the UPSilon 2000 CD into CD ROM UPSilon 2000 will display the in
14. arry out the software configuration and operation Today the Internet is widely used not only for PC but also for Server coming into the times of receiving and sending information 24 hours a day The power management without people has been a necessary function of UPS UPSilon 2000 with full functions will be the best partner of your smart UPS Packing including One UPSilon 2000 software CD One UPSilon 2000 cable UPSilon 2000 1 Introduction 1 2 System requirements UPSilon 2000 hardware and software requirements as follows Computer system RS232 communication port COM1 COM4 or USB port Match True RS 232 communication UPS Microsoft Windows 95 Microsoft Windows 98 Microsoft Windows NT v4 0 Microsoft Windows 2000 Microsoft Windows ME Microsoft Windows XP Novell NetWare v3 1x v4 x v5 x Linux FreeBSD UPSilon 2000 Hardware Installation 2 Hardware Installation Please go by the following steps 1 Connect male connector of UPSilon 2000 cable to UPS communication port D p ZE E u PC UPSilon 2000 CABLE UPS 2 Connect the female connector of UPSilon 2000 cable to RS 232 communication port of system If there is only a 25 pin RS 232 connector you can use the 9 pin to 25 pin adapter to convert it 3 COM Port Definition in NetWare UO Address IRQ COM1 3FX 4 COM2 2FX 3 COM3 3E8 4 COM4 2E8 3 WARN
15. ating System and UPS 3 4 3 8Closed Files Record In this section you can check the closed applications and saved files Method select Closed Files Record in the function menu It only records the latest saved information Shown as below UPSilon 2000 19 Windows Functions Closed Applications Files Saved As 3 4 3 9 About UPSilon You can learn some information about the UPSilon e g it s version and copyright if you select About UPSilon in function menu 3 4 3 10 Exit UPSilon Select Exit UPSilon in function menu to close the UPSilon 20 UPSilon 2000 NetWare Features 4 UPSilon 2000 for NetWare 4 1 Features e Auto sending warning messages by e mail e Auto sending warning messages by pager e Auto detecting AC power failure and UPS battery low e Providing the UPS expected time setting of power supply e History data recording e Auto shutting down the system and turning off the UPS when AC power failed e Broadcasting the warning messages to all the workstations e Display the system shutdown countdown e Able to operate on server and workstation Schedule on off in a week e Programmable UPS auto testing period e UPS status reporting on server screen including the input output voltage load line frequency temperature and so on e Local Network UPS monitoring through an Net Agent or SNMP Agent UPSilon 2000 21 NetWare Software Installation 4 2 So
16. csose 4 GE FEATURES e EE e saute E a hieoneeeniete 4 3 2 SOFTWARE INSTALLATION 5 3 3 START UP AND UNINSTALL UPSILON 2000 6 3 3 1 Start up UPsieon cece cece sence s EE ee 6 3 3 2 Uninstall UPSilon sesscessceascesenasess 6 S74 FUNCTIONS ee dE NENNEN NEEN ENEE H 3 4 1 UPS dynamic display area 7 3 4 2 OPS StQtus ATG 23 oes peniser eie p Bae eege state 8 3 4 3 Function selection area ss esscesscssesao 8 B74 Jal Select UPS pa NO Rs ones 8 SE E E EEN 9 Mk Schedules ii sss e Sie ashore dee 16 3 4 3 4 Data rege eege a ar ka ea ere dE 17 374535 Event bugs iene dese aie dere 18 3 4 3 6 History Calender eeeeeeeeeeeeeeeeeeeeeeneeeto 18 324 37 Control ss aan sn een Eed dee ge de 19 3 4 3 8 Closed Files Record 19 3 4 3 9 About UPSilon res eee eco eedo vindo ev eako deo erakas iea reson 20 3 4 3 10 Exit UPS Ones su kr iea aO 20 4 UPSilon 2000 for Net Ware ssssssssoscccesesssssscvcvces 21 4 HBATURES gralo pe pe ae e eO eno 21 4 2 SOFTWARE INSTALLATION 22 4 2 1 Software Installation Procedure 22 4 2 2 File Descriptions ssssss sseeseesennsneooon 23 UPSilon 2000 1 4 3 MAIN SCREEN DESCRIPTION 24 4 3 1 Schedule Display Area 24 4 3 2 Bar chart display area U U U U 25 4 3 3 UPS Status Display Area
17. e Pager y n This option sets whether to send the warning messages to inform the administrator by pager e Enable E mail y n This option sets whether to e mail the warning messages to inform the administrator UPSilon 2000 NetWare Main Menu Functions 4 4 2 Configure E mail You can configure to send the messages i e AC power fail UPS battery low or system shutdown signal detected by UPSilon to inform the system administrator by e mail The setting mode and figure is as below 1 Postoffice server IP address input the server IP address in digital e g 210 71 130 1 and press lt Enter gt to save 2 E MAIL ADDRESS input the e mail address for receiving the event messages and you can send the messages to different stuff respectively You should compart the addresses with comma and press lt Enter gt to save Email Configuration Postoffice xxx xxx xxx xxx 127 0 0 1 POWER EVENT E MAIL ADDRESS at FAIL Battery Low maintenanceGmegatec com tw AC Power Recovered maintenanceGnegatec com tw Battery Low Recovered maintenanceGmegatec com tw maintenanceGmegatec com tw Schedule Down Schedule Down Cancelled maintenance megatec com tu 4 4 3 Configure Pager You can configure to send the messages i e AC power fail UPS battery low or system shutdown signal detected by UPSilon to the system administrator by pager The setting mode and figure is as below 1 Modem Connect
18. estored in the setting time After operating system has been shut down the UPSilon will turn off UPS and the system will be restarted when AC power restored e The meanings of input AC Power are Normal AC Power Normal Failed AC Power Failed e Battery Low This shows whether the UPS battery is getting exhausted When UPS battery power low the UPS could supply system with power The UPSilon will broadcast the battery low situation to all the workstations and the system would be shut down in a minute UPSilon 2000 NetWare Main Screen Description e The meanings of Battery Low are NO UPS Battery Normal YES UPS Battery Low e Next Shutdown Time Next system shutdown time in the schedule setting e Next Startup Time Next start time of system in the schedule setting 4 3 2 Bar chart display area POWER LOADING 1 l l 1 l 1 L 0 20 40 O 80 100 120 9 BATTERY LEVEL 22 100 H 15 30 45 60 75 90 GO VOLT CONDITION LINE 107 00 70 80 90 100 110 120 130 VU e POWER LOADING Percentage of power loading When loading is more than 90 percent the bar will turn red to show the warning signal e BATTERY LEVEL UPSilon 2000 25 NetWare Main Screen Description Percentage of UPS Battery power When the battery power level drops below 20 percent The bar will turn red to show the warning VOLT CONDITION Input voltage of AC Power 4 3 3 UPS Status Display Area UPS Statu
19. for 0 5 second delay time At last input the pager number 3 Code to send you can input the event code for sending For instance Set the Modem connect to COM2 and dial 0 to access an outside line and pager number is 0 947123456 and 1234 means AC power failed Set Pager Numbers and Codes Modem Connected To COM2 K Event Pager Number Code To Send AC Failure 0 0947123456 1 234 UPS Battery Low 0 0947234567 112233 AC Power Restored 0 0943456789 33221 Recovered from Low Battery 00943987654 kees Impending Scheduled Shutdown 0 0959654321 Jesse Scheduled Shutdown Cancelled 00959654321 em Battery Bad o o959223344 Juan cma Attention The action should be done within 20 seconds from calling pager number to sending code transmission UPSilon 2000 Windows Functions D Automatic Shutdown Time Parameters UPS allows the users some time to shut down system before the UPS battery is exhausted The characteristic configuration of UPS makes it to be sure that system can be restarted and operated normally After AC Failure Commence Computer Shutdown Sequence in Set the continuous time for system operation after AC power fails Please refer to the UPS hardware manual or consult to the UPS supplier before your configuration setting range 1 2880min default value 10min If Low Battery Occurs Commence Shutdown Sequence in Set some time for syste
20. ftware Installation UPSilon for NetWare is a NetWare Loadable Module NLM The installation will copy files into SYS SYSTEM and modify the file AUTOEXEC NCF All these software installation procedures require the user is able to read and write files in sub directory SYS SYSTEM 4 2 1 Software Installation Procedure 22 1 Login the file server as a SUPERVISOR or a user with access rights in sub directory SYS SYSTEM F gt LOGIN SUPERVISOR Put the UPSilon CD in CD ROM Execute INSTALL EXE in CD ROM A gt INSTALL After installation please shutdown NetWare operating system and restart again The system will load the UPSilon NLM and execute it When UPSilon for NetWare has been loaded server screen shows the successful loading message You could switch to the UPSilon with key ALT ESC If you have more than one com port on your File Server please insert two or more LOAD AIOCOMX command in the system AUTOEXEC NCF file after UPSilon 2000 installation UPSilon 2000 NetWare Software Installation After installation the main screen of UPSilon for NetWare is as below UPSilon Version 2 0 NetWare Loadable Module Wednesday April 07 1999 PM 12 40 53 Input AC Power Normal Battery Low NO 4 3 1 Schedule Next Shutdown Time 04 07 1999 18 30 Next Startup Time 04 08 1999 07 30 Display Area POWER LOADING UPS Status 24 4 4 l 4 L L Monitor Comport UPS O 20 40 60 380 100 120 2 Temperature
21. he setting figure is as below Schedule ShutDown Sun Hon Tue Wed Thu Fri Sat S MUN 09 00 08 30 09 00 07 30 08 00 08 30 D 18 00 17 30 18 30 17 30 17 00 12 30 Start Up Time Format HH MM D Shut Down Time 24 hour clock eS Start Up Time system start up time e D Shut Down Time system shut down time e Format these inputs are in 24 hours format with HH MM be ignored with a blank input For instance in the scheduled shutdown table shown in the above the system will be turn on 9 00 next Monday morning and be turn off 6 00 at night The system will be turn on 8 30 Tuesday morning and be turn off 5 30 in the afternoon the rest may be deduced by analogy The system will not be turn on or turn off on Sunday Attention Do not turn off the UPS power switch That will make the UPS unable to wake up 4 4 5 Setup SNMP Choose this function to monitor UPS via Net Agent or SNMP Agent in Lan The meaning of each field is as detailed below UPSilon 2000 35 NetWare Main Menu Functions SNAP Configuration Use SNMP to Monitor the UPSTly n M IP Address 192 168 0 1 Community Name public Allow UPS Shutdown p n y E Use SNMP to Monitor the UPS Set this value to Monitor UPS via Net Agent or SNMP Agent MIP Address Set Net Agent or SNMP Agent s IP E Community Name Set public or private E Allow UPS Shutdown Shutdown UPS when power event occurs IE Poser inl Batter Le MI kani SE
22. hod press select UPS for the selection Shown as below Select Select Select a UPS to Monitor Monitor Monitor Monitor Local UPS Remote Local Monitor Remote UPS UPS UPS Cancel 1 A Monitor Local UPS Select monitor local UPS B Monitor Remote UPS UPSilon 2000 Windows Functions 1 Select monitor remote UPS 2 You can modify or insert the remote UPS data to the form and then exit 3 Select the UPS which you want to monitor and control in drop down menu 4 Start to execute the function to monitor remote UPS a 3 4 3 2 Settings Select the UPS and press settings for the parameter value configuration Shown as below UPSilon 2000 9 Windows Functions 10 mom General Settings Communication Type RS232 Demo Select Comm Port Configure communication port to connect with the UPSilon cable COM1 COM4 Password Set the password of the remote connection of the UPSilon The connection would be successful only if the right password is provided The password prevents the remote unconfirmed computer from connection Record UPS Data Set the record time interval about input amp output voltage line frequency load battery capacity and temperature UPSilon 2000 Windows Functions B Computer Shutdown Sequence Settings In this section you can set the functions you want to execute when the UPSilon detects the signal for closing the computer e Optional
23. m s continuous operation when battery low For the setting value the smaller is the better setting range 1 600min default value 1min Time Needed for Shutdown Sequence Before UPS Turn Off Set time interval from Windows shutdown to UPS power supply turn off It should be considered whether the time is enough for archiving before the system shutdown The time for archiving would be different for the amount and the size of the opened files setting range 0 2 99min default value 2min UPSilon 2000 15 Windows Functions e Pop Up Warning Message Every Set the time interval of displaying the warning messages setting range 10 600Secs default value 30Secs 3 4 3 3Schedule 16 UPSilon can set the scheduled time for UPS turn on off and self test Therefore the system could be operated without the management from system supervisor You can set what and how often the schedule execution is The setting category and operating frequency are as below e Actions Turn on UPS Shutdown Operating System and UPS UPS Self Test Until Battery Low UPS Self Test for 10 Secs UPS Self Test n mins e Frequency Once Daily Weekly Monthly Setting method press Schedule in function menu Select the date in the upper of left corner then press the key Add for the schedule Configuration After the action and frequency s selection press OK and back to the Schedule screen then the new schedule could be seen in the
24. n when the UPSilon detected AC power failure UPS battery low or the signal of closing the computer You can use the default message or you can set or modify the message on your own UPSilon 2000 Windows Functions EI Scheduled Shutdown Warning Scheduled Shutdown Aborted Attention Battery Bad zen j zen Enable E Mail In this configuration the messages could be sent to the administrator by e mail Shown as below 1 E mail Server IP Address In numbers E g 210 71 130 1 2 Send to E mail Address type the e mail address Send the message to different staff and space each e mail address with a comma The number of e mail address is unlimited E mail EI 210 71 249 66 service megatec com tw aaa megatec cr bb megatec com tw cc megatec com tw dd megatec com tw ga megatec com tw 1234 megatec com tw 9999 megatec co 8888 megatec com tw 777777 megatec Enable Pager UPSilon 2000 13 Windows Functions 14 In this function the users can set the messages to the system administrator by pager The configuration s mode and screen is as below 1 Modem connects to set the communication port which connects with the Modem The setting value is COM1 COM4 2 Pager number Input the pager number directly if you are using the special line i e the line which has no use for a switchboard If necessary please input the prefix code for outside line first Then add
25. on Please refer to the UPS power capacity in UPS user s manual for proper delay time setting for your system UPSilon 2000 29 NetWare Main Menu Functions 30 e Delay Between Warning Message When AC power failed the file server will send warning messages to all the workstations This option sets the duration between every warning message setting range 5 30 seconds default value 20 seconds e Delay of Shutdown Server when Battery Low This option sets the delay time between UPS battery low and file server shutdown When AC power failed the UPS will supply the power to your system from the UPS battery But if the UPS battery is in low capacity discard what is the setting delay time between AC fail and file server shutdown the system will shut down the file server in the delay time of this option This will protect the file server from instant turn off due to insufficient battery power setting range 0 2 minutes default value 1 minute e Duration of UPS Auto Testing This option is for setting both functions below 1 The battery discharge time of the UPS when doing the self testing UPSilon 2000 NetWare Main Menu Functions 2 This is to set a period of time for executing RUPSDOWN NCF before system shutdown See section P40 4 6 for details of these settings setting range 1 99 minutes default value 10 minutes Communication Serial Port This option sets the communication port be
26. r 10 seconds Execution mode press lt Enter gt in Main Menu for selecting UPS 10Sec Test and press Esc back to the main screen This Testing will be shown in bar of UPS Status In order to stop the test please go back to Main Menu and select UPS 10Sec Test once again UPSilon 2000 37 NetWare Main Menu Functions 4 4 9 UPS Auto Test This function will make the UPS to discharge the battery and to do the self testing The period of battery discharge is according to the setting in configuration menu 4 4 10 View History File This function could review the records of system history files It includes date time input output voltage line frequency load UPS battery capacity temperature and so on DATE TIME AC_in Out Hz Load Batt oF 047067199 5 01 047067199 047067199 047067199 047067199 047067199 Ki 047067199 047067199 047067199 047067199 047067199 d ad mb md ech md md md ech ech amb ech ech EaEaEaEaEa E EE EES EES ES TJ Sal Sal Gel laJ Sal al Gel maJ maJ maj maj maj EaEaEaEaEaEaEaEaEaEaEaEaE ch hb mk mk mi mh mk mk mk mk mk mk ech ROMO ND NON NON N NNN N A LO LO TI cians cen I Lo A EaEaEaEaEaEaEaEaEaEaEaEa E CH NO MD NO ND RO RON NON RON b i 4 4 11 View Log File This function could review the records of system log files It includes abnormal AC power status of UPS and so on UPSilon LOG 03 25 1999 22 16 49 ees UPSilon U2
27. record If you want to set more records repeat the above After UPSilon 2000 Windows Functions configuration press save for archiving or select the item then press remove for taking out the record Shown as below Date YYVIMMIDD EE gt EE Add Remove 09 00 AM 1999 05 27 Thursday lt lt Turn On UPS gt gt Daily 06 00 PM 1999 05 27 Thursday lt lt Shutdown OS and UPS gt Daily 12 00 AM 1999 05 27 Thursday lt lt Self Test till Battery Low gt gt Weekly 10 30 AM 1999 05 27 Thursday lt lt Self Test 10 seconds gt gt Weekly Next Scheduled Shutdown 1999 05 27 06 00 PM Next Scheduled Bootup 1999 05 28 09 00 AM Save Next UPS Self Test 1999 06 03 12 00 AM Cancel 3 4 3 4Data Log The UPS data could be recorded in this section such as the input and output voltage line frequency load battery capacity and temperature etc The record interval could be altered in the area of Automatic Shutdown Time Parameters in settings of the function menu In the section of Data Log press update for data refreshing and press clear for data deletion Shown as below 1999 05 27 14 5 1090w 1230v 60 0Hz 100 1999 05 27 14 5 1090w 123 0 60 0Hz 100 1999 05 27 14 5 1090w 126 0 60 0Hz 100 96 1999 05 27 14 5 1090w 126 0 60 0Hz 100 1999 05 27 14 5 1090w 125 0v 60 0Hz 100 1999 05 27 14 5 1090w 1250w 60 0Hz 100 96 1999 05 27 14 5 109 0v 125 0v 60 0Hz 100 1999 05 27 14 5 1090w 125
28. s Monitor Comport UPS Temperature 80 F z EO kb Output Volt 125 0 VAC Line Freq 60 Hz Batt Status Normal UPS Status Mormal UPS Testing Hormal UPS Type ON Line Serial Port COM2 Comm Status Connect Temperature the interior temperature of UPS Output Volt The output voltage of UPS Line Freq The line frequency of input voltage u gt gt a Batt Status UPS battery status Normal UPS Battery Normal Failed The UPS Battery Failed Please Examine and Repair 26 UPSilon 2000 NetWare Main Screen Description e UPS Status Normal Online UPS In a Normal Condition Batt Mode UPS supply the system with power Bypass AC power bypasses the system power directly Boost system power voltage is too low UPS boosts the system power e UPS Testing This shows whether the UPS is doing the self testing Normal UPS had done or did not do self testing Testing UPS self testing e UPS Type On line On line Type UPS Off line Off line Type UPS Serial Port Shows which communication port is used for UPS communication Comm Status Show the status of UPS communication Connect System connects to UPS Disconnect System did not connect to UPS UPSilon 2000 7 NetWare Main Menu Functions 4 4 Main Menu Functions Press F10 in the main menu of UPSilon for NetWare and this will be shown on the screen as follows Font igurat ion Configure E mail Configure Fager Schedule
29. s to Communication Serial Port configure which communication port connects to Modem The setting value 1 4 UPSilon 2000 33 NetWare Main Menu Functions 2 PAGER NUMBER input the calling pager number If necessary please input the code for outside line first then add for 0 5 second delay time the full pager numbers at last 3 Code to send you can input the sending code that stands for some event For instance Set the Modem to connect to COMI and dial 0 to access an outside line and the pager number is 0 0947 123456 and 1234 means AC power failed Pager Configuration Communication Serial Port 0 4 1 POWER EVENT PAGER NUMBER MESSAGE AC FAIL Battery Low Io AC Power Recovered 0 094 Battery Low Recovered 0 schedule Down Schedule Down Cancelled 4 4 4 Schedule Shutdown In this function you can set the ON OFF time of the file server every week Before the scheduled shutdown system will send out the warning messages to inform users on the network and it would permit users to finish the process on the network This warning message starts 5 minutes before scheduled shutdown and will be sent out every minute 34 UPSilon 2000 NetWare Main Menu Functions The system will shut down file server and UPS at the scheduled shutdown time The UPS will be in sleeping state and wake up according to the next scheduled turn on time T
30. stallation menu or you can select run from windows start menu and execute setup exe 3 Select language when install If desire to change language uninstall UPSilon and install again for new selection 4 After installation UPSilon 2000 files will be copied into the directory you appointed UPSilon 2000 5 Windows start up amp uninstall 3 3 Start up and Uninstall UPSilon 2000 3 3 1 Start up UPSilon After installation please restart the computer For Windows 95 98 check if there is a Rupsmon Daemon icon in task bar For Windows NT go to control panel gt service and check if Rupsmon service has started UP Seini NIE Rupsmon Daemon If you want to change the function configuration please run the UPSilon in the task bar directly or select UPSilon for Windows from UPSilon in program group of start menu in Windows 3 3 2 Uninstall UPSilon After installation there is 6 selection as below under UPSilon in Windows start menu If you want to remove the UPSilon from the system please select UPSilon Uninstall ei Help Register UPSilon l Rupsmon Daemon UPSilon for Windows A UPSilon Readme Tf UPSilon Uninstall e Help UPSilon introduction 6 UPSilon 2000 Windows Functions Register UPSilon UPSilon register form Rupsmon Daemon UPSilon core program UPSilon for Windows Enter into UPSilon main function figure UPSilon Readme UPSilon simple
31. tween UPS and file server RS232 port This RS232 port could only be used by UPS do not shared with other equipment setting range COM1 COM4 default value COM1 e Time of History Recording This option sets the delay time between every system status record in the history file setting range 0 120 minutes default value 1 minute Attention System status recording will be turn off when this option set as 0 e Period of UPS Auto Testing The battery of UPS would not be last long if it is always in the ample state Therefore you should make the UPS testing UPSilon 2000 31 NetWare Main Menu Functions 32 itself and using the power of battery once in a while That is exactly what the function of UPS auto testing is doing This option sets the period of UPS auto testing setting range 1 4 weeks default value 1 week e Battery Voltage Rating This option sets the reference voltage of the UPS battery The UPSilon could calculate the battery capacity only if the accurate input of the battery voltage This voltage setting is also the reference for showing UPS capacity Most of the on line UPS could provide this information for UPSilon and the users do not have to give the battery voltage setting here If the status of battery capacity shows incorrect value or you are using off line UPS you have to give the voltage rating of the UPS battery Please refer to the manual of UPS for battery voltage rating e Enabl

Download Pdf Manuals

image

Related Search

Related Contents

8. Secondary ELL Student Tracking Form  Mode d`emploi Fers Vapeur Program8  LG 55UB9500 Specification Sheet  Whistler XTR-445 User's Manual    Steuerung ELE7760 für Rolltore im Privatbereich  Bradford-White Corp D)W275T*(BN User's Manual  manuale e istruzioni montaggio new mobilsat  Fiche d`examen au cas par cas - DREAL Franche  SOUND HOUSE INC.  