Home
Owner`s Booklet Libreta del propietario
Contents
1. Press and hold 9 Date Time t x appears in display Release after full Display appears and Meter beeps Set Time 2 The hour flashes To change press J or on top of Meter to select the hour Like many alarm clocks to set PM scroll through hours until PM appears in Display Note PM does not display if Meter is factory set to 24 hour clock Press S to set 3 The minutes flash To change press por efto select the minutes Press 9 to set BEBE BEBB 8888 Mem Avg Ups Full Display 5 36 Hour PM 27 Minutes Set Date 4 The month number flashes To change press J gt or to g select the month Press 9 to set 5 The day number flashes To change press E or GJ to select the day Press Oto set 6 The year flashes To change press gt or GJ to ed select the year Press 9 to set Month Exit Set up To review settings press Q9 Make changes as needed per instructions above Press and hold until Display goes blank Options are saved Meter turns off 28 Memory Morning Averages 14 and 30 Day For Morning Average values only the earliest blood test result performed between 4 00 am 9 59 am according to Meter clock is used Meter clock must be set correctly see Set Up for accurate Morning Average values 1 Start with Meter off Press and release 9 Display shows 14 day Morning Average value and then 30 day Morning Average valu
2. 3 mL Water 73 D glucose 0 09 0 20 Viscosity Enhancing Agent 25 Inorganic Salts 1 8 Amaranth 0 08 and Preservatives 0 03 39 TRUEtrack Limited Lifetime Warranty Nipro Diagnostics Inc provides the following Warranty to the original retail purchaser of the TRUEtrack Meter 1 Nipro Diagnostics Inc warrants this Meter to be free of defects in materials and workmanship at the time of purchase If the meter is ever inoperative Nipro Diagnostics Inc will replace the Meter with an equivalent Meter at its option at no cost to the purchaser Failure of the meter due to abuse or use not in accordance with the instructions for use is not covered by this Warranty 2 This Warranty does not include the battery supplied with the Meter 3 Do not take the Meter apart This action will void the Warranty and cause the Meter to display false results 4 The duration of any implied Warranty including any implied Warranty of merchantability or fitness for a particular purpose shall be limited to the lifetime in use with the original user in accordance with any state law to the contrary 5 Nipro Diagnostics Inc disclaims liability for incidental or consequential damages for breach of any expressed or implied Warranty including any implied Warranty of merchantability or fitness for a particular use with respect to the Meter Some states do not allow the exclusion or limitation of incidental or consequential damages so t
3. 8 10 Match Code in Display with Code on Test Strip vial label being used If Codes do not match see Coding Press E Control Symbol appears in Meter Display a Control Test press lt to remove Control Symbol Control Symbol Turn Control bottle upside down Squeeze one drop of Control onto a clean tissue Wipe off bottle tip Gently squeeze a drop on a small piece of unused aluminum foil or clear plastic wrap Dispose after use With Test Strip still in Meter touch edge of Sample Tip to drop of Control and allow drop to be drawn into Test Strip Remove Test Strip from drop when Meter beeps Meter begins countdown 20 Note If Meter does not beep or begin countdown soon after placing Sample Tip to Control drop discard Test Strip Repeat test with new Test Strip If problem TRUEcontror persists see Troubleshooting TI ER MES Resin o 11 Compare result to Control range D ease i fori ir di sy i printed on Test Strip vial label Toc 3 Conservar entre 36 86 F 2 30 Q If result is in range System A can be used for testing blood O 31 61 mg dL If result does not fall within 1 87 117 mg dL range repeat test using a new 2 247335 mg dL Test Strip Note Control Test result shows the Control Symbol in the Display Note When using the meter for the first time check the unit of measure in the meter Display after performing a control or blood test Result
4. RUE rack Owner s Booklet 24 7 Customer Care English or Spanish 1 800 803 6025 www niprodiagnostics com Manufactured by NIP O DIAGNOSTICS Fort Lauderdale FL 33309 U S A 2015 Nipro Diagnostics Inc TRUEtrack and the Nipro Diagnostics logo are trademarks of Nipro Diagnostics Inc A4NPDO3 Rev 26 TRYEtrack For quick reference only not intended as a substitute for complete instructions Please read entire Owner s Booklet and product Instructions for Use before testing Welcome to the TRUEtrack Blood Glucose Monitoring System Congratulations on your purchase of the TRUEtrack Blood Glucose Monitoring System You now have a very simple and accurate way to test your blood glucose sugar level anytime anywhere Our Commitment to You Our goal is to provide you with quality healthcare products and dedicated customer service If you have questions about using TRUEtrack products visit our web site at www niprodiagnostics com Instructions for use of the System in a professional multi patient setting are included in the Quality Assurance Quality Control Manual The QA QC Manual is available call 1 800 803 6049 or 1 954 677 4599 CAUTION Please read complete Owner s Booklet and all product Instructions for Use Expected Results for people without diabetes Plasma Blood Glucose Result Before eating lt 100 mg dL Importance of Blood Glucose Monitoring The more you know about diabetes
5. A Insert a Strip into the Test Port ab The Meter is working properly if WM e the full Display appears then 8888 8888 e the time appears in the upper m n part of the Display and then Oot e the Drop Symbol begins to blink ee If an error message appears in the Display Full Display the Meter will not perform a test See Troubleshooting or call for assistance see cover for phone number J 4 Caution If any segments are missing in the Display when Meter is first turned on do not use the Meter for testing Call for assistance Control Test We recommend performing Control Tests for practice before using your Meter for the first time to test your blood Control Tests should be performed For practice to ensure your testing technique is good Occasionally as you use the vial of Strips When opening a new vial of Strips If results seem unusually high or low If a vial has been left open or exposed to extreme heat or cold or humidity e If Meter damage is suspected Meter was dropped crushed wet etc Note Three levels of TRUEcontrol Glucose Control Solution are available for Quality Control Testing It is important to perform Control Tests with more than one level of Control to assure your System is working properly and your testing technique is good Contact place of purchase or call for assistance to obtain Control Caution Control ranges printed on Test Strip vial label are for Control Test
6. the better you will be able to take care of yourself A Doctor or Diabetes Healthcare Professional will determine your target range for your blood glucose results and how often to test Having the majority of your results within your target range helps slow or stop complications of diabetes Having most blood glucose results within your target range shows how well a treatment plan is working to control glucose levels NEVER change your treatment plan without consulting with your Doctor or Diabetes Healthcare Professional Use of the TRUEtrack in a manner not specified in this Owner s Booklet is not recommended and may affect your ability to determine your blood glucose FOR PATIENTS IMPORTANT HEALTH and SAFETY INFORMATION WARNING NEVER reuse Test Strips NEVER wipe Test Strips with water alcohol or any cleaner DO NOT attempt to remove blood or control sample from Test Strips or clean Test Strips and re use Reuse of Test Strips will cause inaccurate results o NEVER add a second drop of sample to Strip Adding more sample gives an error message The TRUEtrack Blood Glucose Monitoring System is for one person use ONLY DO NOT share your Meter or your Lancing Device with anyone including family members DO NOT use on more than one person ALL parts of your Blood Glucose Monitoring System could carry blood borne diseases after use even after cleaning and disinfection For cleaning and disinfecting your Meter see Mete
7. SEs Reason Temperature Error Temperature change too quick Temperature Too Cold Meter temperature less than 50 F Temperature Too Hot Meter temperature greater than 104 F Sample Not Detected or Using Wrong Test Strip Used Test Strip or Test Strip outside of vial too long 35 Action Wait 10 minutes for Meter and Test Strips to reach room temperature before testing Move Meter and Test Strips to area between 50 104 F before testing Move Meter and Test Strips to area between 50 104 F before testing Retest with new or correct Test Strip and larger sample Repeat with new Test Strip If error persists call for assistance Messages continued Display im Li ao m L wu E 1 cio L Ll Reason Meter Error Test Strip Error Very high blood glucose result higher than 600 mg dL Test Stri Remove During Test Meter Error Code Chip Error 36 Action Call for assistance Retest with new Strip If error persists call for assistance If you have symptoms such as fatigue excess urination thirst or blurry vision follow your healthcare professional s advice for high blood glucose Retest with new Test Strip If error persists call for assistance Call for assistance Remove Code Chip and reinsert If error persists call for assistance Messages continued Display Reason L L Communication L l Error Low Ba
8. is complete Note Used Strips and lancets are considered biohazardous Dispose used Strips and lancets in approved biohazard container 22 From Forearm 1 Select area to be lanced Wash with soap and warm water rinse and dry thoroughly 2 Rub area vigorously or apply a warm compress to increase blood flow FZ af 3 Place end of Lancing Device firmly aU against forearm Press trigger button Apply firm pressure on lancing device EN for 10 seconds d Note Some lancing devices include a special end cap for alternate site testing Check lancing device Instructions for Use Important Notes Regarding Forearm Testing Check with your Doctor or Diabetes Healthcare Professional to see if forearm testing is right for you e Results from forearm are not always the same as results from fingertip e Use fingertip instead of forearm for more accurate results Within 2 hours of eating exercise or taking insulin If your blood sugar may be rising or falling rapidly or your routine results are often fluctuating If you are ill or under stress If your forearm test results do not match how you feel If your blood sugar may be low or high If you do not notice symptoms when blood sugar is low or high 23 How to Test Blood Glucose Check supplies Always check your supplies before using Check Meter for dames damaged or cracked Display missing or damaged buttons If any damage is seen do no
9. must display in the correct unit of measure mg dL If the result does not display in the correct unit of measure DO NOT use the meter and DO NOT use the meter result to determine treatment Caution If Control Test result is outside range test again If result is still outside range System should not be used for testing blood Call for assistance see cover for phone number 12 Remove Strip from Meter and discard Meter turns off Recap Control bottle tightly 21 Obtaining a Blood Sample Refer to Lancing Device Instructions for Use for detailed instructions The Lancing Device is for single patient use ONLY For cleaning disinfecting your Lancing Device see Lancing Device Care in the Lancing Device Instructions for Use Wash your hands thoroughly with soap and warm water after handling the Meter Lancing Device or Test Strips Contact with blood presents an infection risk e Never share lancets or lancing device e Lancets are for single use only Do not re use From Fingertip 1 Prepare fingertip by washing hands in warm soapy water Rinse well Dry thoroughly 2 Place end of Lancing Device against tip of finger Lance fingertip 3 Set Lancing Device aside To help blood drop form DM hand to waist level gently massaging finger from palm to fingertip Allow blood drop to form before attempting to apply to Test Strip Always recap remove and discard used Lancet in appropriate container when testing
10. quantitative system that is used for self testing and point of care bedside testing of human whole blood only Check Codes Code in Meter Display must match Code on vial of TRUEtrack Test Strips being used and Code Number printed on Code Chip Meter displays results as plasma values Use only TRUEtrack Test Strips and TRUEcontrol Glucose Control Solution with TRUEtrack Meter Do not use for diagnosis of diabetes or for testing blood glucose in newborns The TRUEtrack is recommended for testing of human capillary whole blood only TRUEtrack is not recommended for use with venous samples Perform Quality Control Testing before performing a blood test for the first time Note Three levels of TRUEcontrol Glucose Control Solution are available for Quality Control Testing We recommend testing at least 2 levels of Control Contact place of purchase or call for assistance to obtain Control Set date and time for correct Morning Average values When using the meter for the first time check the unit of measure in the meter Display after performing a control or blood test Result must display in the correct unit of measure mg dL If the result does not display in the correct unit of measure DO NOT use the meter and DO NOT use the meter result to determine treatment 5 Health Related Information For Healthcare Professionals If comparing results between TRUEtrack and a lab system perform a TRUEtrack blood test within
11. results only and are not suggested levels for your blood glucose Do not drink Glucose Control Only the most current Control Test result is stored in Memory How to Test Glucose Control Use ONLY TRUEcontrol Glucose Control Solution l 3 4 Note Use Test Strip quickly after removal 22 939 5 with the TRUEtrack Meter Wash hands with soap and water dry thoroughly Allow Control vial of Test Strips and Meter to adjust to room temperature 68 77 F Write date first opened on Control Label and or Test Strip vial label Check dates on Control label and Test Strip vial label Do not use Control if 3 months past written opened date or past date printed next to EXP whichever comes first Do not use Test Strips 120 days past written opened date or past date printed next to EXP whichever comes first Discard out of date products and use new products if either date has passed LOT BLOAI8 Swirl or invert bottle gently to mix Control DO NOT SHAKE CODE 1027 Remove Test Strip from vial Recap vial immediately 4 Lj i from vial Test Strips that have been left out of vial too long will give an error message If error message appears in Display discard old Test Strip and test with new Test Strip Insert Test Strip Contact End Contacts facing up into Test Port Meter turns on Keep Test Strip in Meter until testing is finished 19 Contacts Face Up 6 Note If you decide not to perform
12. 30 minutes of lab test Results from TRUEtrack are considered accurate if within 20 of lab results If patient has recently eaten fingerstick results from TRUEtrack can be up to 70 mg dL higher than venous lab results Do not use venous blood with TRUEtrack 5 Instructions for use of the System for more than one person may be found in the Quality Assurance Quality Control Manual The QA QC Manual is available call 1 800 803 6025 or 1 954 677 4599 Table of Contents Fast Test Guide ue sen d eh inside front cover Introductory Information sse 1 6 Know Your System METE oes UU DIODORUS 8 10 Test SUHIDicuset uei itd eq ERE eite 11 Test Strip Vial Eabel i inediti ipte 12 Control Bottle Label see 13 Getting Started Coding oos eene eon pedir Quality Control Tests Automatic Self Test Control Test Testing your Blood How to Obtain a Blood Sample ss How to Test Blood Glucose sss System Out of Range Warning Messages Set Up Time Date e ent Memory Morning Averages 14 and 30 Day Viewing Results in Memory Care Cleaning Disinfection and Troubleshooting Caring for TRUEtiA k 5t one ope bone aaa 31 32 Changing Battery suisse tessera tete tei s 33 Troubleshooting Display Messages eoe eee n tes System Specifications nitent iiber netten tits Chemical Composition Meter Warranty sss l
13. XP whichever comes first Control Range Range of numbers in which Control Test result must fall to assure System is working properly Caution Use of Test Strips or Glucose Control past the Expiration Dates may give incorrect test results Discard out of date products and test with new products Glucose Control Control Bottle Label TRUEcontrol Glucose Control Control de Glucosa Level TE en diagn stico 6 86 F 2 30 Q R NI CONGELAR EXP 2017 10 31 oo q g 3 E o d MSNPDOI Rev 20 Lot Number LoT Used for identification when calling for assistance Expiration Dates EXP Write date first opened on bottle label Discard bottle if either 3 months after opening or date printed next to EXP on bottle label has passed whichever comes first Control Level 0 1 or 2 Three levels of TRUEcontrol Control are available We recommend testing at least 2 levels of Control Use the number on the cover for information on how to obtain different levels of Control Getting Started The Meter turns on automatically when a Test Strip Contact End is inserted into the Test Port or when is pressed see Set Up and Memory The Meter turns off automatically after the Test Strip is removed from the Test Port or after 2 minutes of non use Meter comes with pre set time and date Before using the Meter for the first time or after a battery change check the time and date and update as need
14. d on Test Strip vial Discard unused Test Strips from vial 120 days after opening or after date printed next to EXP whichever comes first Use of Test Strips past either date may give incorrect results Close vial immediately after removing Test Strip Use Test Strip quickly after removal from vial Never store Test Strips outside of vial Store in a dry place at room temperature below 86 F DO NOT REFRIGERATE OR FREEZE e Do not reuse Test Strip Do not bend cut or alter Test Strips in any way Code Chip Care Code Chip must remain in Meter until all Test Strips from box are used then discard old Code Chip e Insert new Code Chip from new box of Test Strips immediately before using Test Strips 32 Changing Battery Replace battery when Low or Dead Battery Symbols appear in Display or Meter does J f not turn on 1 Lift tab on Battery Cover Low Dead 2 Turn Meter over tap gently to loosen and remove battery E ak e 4 t 3 Insert new battery positive side up Close cover Note Use non rechargeable 3V lithium battery CR2032 4 Discard old battery in appropriate container 5 Turn Meter on If Meter will not turn on check that battery was installed properly If not reinsert battery and try again Call for assistance if problem persists Warning Battery is not rechargeable If you have a cable or a cradle for downloading results to a computer DO NOT plug the usb cable end into an elect
15. e 2 Meter switches between 14 and 30 day Morning Average values for 2 minutes before turning off 3 Ifthere are no Morning Average values 3 dashes are displayed 4 Press and release to view results in Memory Press and hold Sto turn Meter off or Meter turns off after 2 minutes of inactivity No Averages 29 Viewing Results in Memory Memory stores 365 results which are displayed from most recent to oldest The oldest result is removed from Memory when Memory is full and a new result is added 1 Start with Meter off Press and release 9 Meter displays date and time followed by 14 and 30 Day Morning Averages Press again to view most recent result in Memory 2 Press gt and release to advance to the first blood glucose result in Memory 3 Press B gt and release again to view the latest Control Test result The Control Test result shows the Control Symbol in Display Only one Control Test result is stored in Memory 4 Continue to press and release JE to advance through the blood glucose results Holding E gt scrolls through the results quickly Press and release amp amp fto reverse through the results 5 Press and hold S to turn Meter off Meter also turns off automatically after 2 minutes of inactivity 30 Caring for TRUEtrack e Store System Meter Glucose Control Test Strips in Carrying Case to protect from liquids dust and dirt e Store in a dry place at room
16. ed see Set Up Coding Code Chip is packaged with each box of Test Strips Note After all Test Strips are used from box 1 remove Code Chip from Meter and discard Open new box of Test Strips and insert new Code Chip into Meter before testing Start with Meter off Remove and open Code Chip package from box of Test Strips to be used Match A Code printed on Code Chip to Code agne 1027 printed on vial label OT EAG45A4 Caution If Codes do not match do not use Test Strips Call for assistance 2 If Codes match insert Code Chip into Code Chip Port as shown locking in place 3 Insert Test Strip into Test Port Code i027 Meter turns on Code and number appear in Display CODE 1027 4 Match to Code number LOT EA645A4 on vial label If Codes match begin testing Caution If Code shows in Display reinsert Code Chip and then reinsert Test Strip If Code still shows in Display or if Codes do not match DO NOT use Test Strips Test results could be incorrect Call for assistance Quality Control Testing To assure you are getting accurate and reliable results TRUEtrack offers two kinds of quality control tests These tests let you know that your TRUEtrack System is working properly and your testing technique is good Automatic Self Test An Automatic Self Test is performed by the Meter each time a Test Strip is inserted correctly into the Test Port amp
17. hanged by user 10 Time is PM Note AM does not appear PM is not an option if factory setting is for 24 hour clock MO OB WN Fe Test Strip Front of Test Strip D rmm D Contact End Insert into Meter with Contacts metallic blocks facing up before adding sample Sample Tip Touch sample blood or Glucose Control to edge of Tip Placement of Sample to Test Strip Correct Incorrect e Allow sample blood or Glucose Control Contacts drop to be drawn into Sample Tip Face Up Caution Holding the Test Strip Sample Tip to the blood sample too long after the Meter begins testing may cause inaccurate results Note Do not apply blood or Glucose Control to top of Test Strip e Do not smear or scrape drop with Test Strip e Do not apply more sample to Test Strip after removing from drop Note Do not insert Sample Tip with sample into Meter for testing May damage meter 11 Test Strip Vial Label CODE 1027 QD LOT EA645A4 EXP 2017 10 31 3 O 31 61 mg dL 1 87 117 myd 4 2 247335 mg dL May 30 2015 3 D Code Match Code in Meter Display with Code on Code Chip and Code on Test Strip vial label before testing All Codes MUST match for accurate results 2 Lot Number LoT Used for identification when calling for assistance Expiration Dates EXP Write date first opened on vial label Discard vial and unused Test Strips 120 days after written date or date printed next to E
18. he above limitations or exclusion may not apply 6 This Warranty gives the user specific legal rights and the user may also have other rights which vary state to state Your Nipro Diagnostics Inc Customer Care Representative will be able to provide detailed information regarding procedures for returning your Meter if necessary References 1 American Diabetes Association Diagnosis and Classification of Diabetes Mellitus Diabetes Care Volume 36 Supplement 1 January 2013 2 FDA Public Health Notification Use of Fingerstick Devices on More than One Person Poses Risk for Transmitting Blood Borne Pathogens Initial Communication 2010 http www fda gov MedicalDevices Safety AlertsandNotices 3 CDC Clinical Reminder Use of Fingerstick Devices on More than one Person Poses Risk for Transmitting Bloodborne Pathogens 2010 http www cdc gov injectionsafety Fingerstick DevicesBGM html 4 Atkins S H Dasmahapatra A Jaker M A Chorost M I Redd S Fingerstick Glucose Determination in Shock Annals of Internal Medicine 114 1020 1024 1991 5 Data on file 6 Larsson Cohn U Difference between capillary and venous blood glucose during oral glucose tolerance tests Scand J Clin Lab Invest 36 805 808 1976 7 US Food and Drug Administration Blood Glucose Meters Getting the Most Out of Your Meter Electronic Version Retrieved December 22 2009 from http www fda gov MedicalDevices Safety AlertsandNotices Tipsa
19. nc EE Know Your System Meter Front of Meter Top of Meter term 3 amp Button Decrease numbers in Set Up remove Control Symbol move backward by time date when viewing results in Memory Q 9 Button Select settings view Morning Average values view results in Memory F gt Button Increase numbers in Set Up add Control Symbol move forward by time date when viewing results in Memory Display Shows test results messages user prompts and other information Test Port Insert TRUEtrack Test Strip here 8 Back of Meter Right Side of Meter SN 123456 i MEINI TILTI LL Left Side of Meter Data Port Contact Customer Care at the number located on cover for more information Code Chip Port Insert the Code Chip here Battery Compartment Use one non rechargeable 3V lithium battery CR2032 positive side up Note See Changing Battery for details 9 Meter Label Contains telephone number for assistance Serial Number Label Identifies Meter when calling for assistance Display ut ul Time Date 14 30 Day Average Code Result in Memory 14 or 30 Day Morning Average Test result Battery Symbol see Display Messages Temperature Symbol see Display Messages Drop Symbol Apply blood or Glucose Control 8 Control Symbol see Glucose Control Test 9 Unit of Measure Note Factory Set Cannot be c
20. ndA ticlesonDeviceSafety ucm109371 htm A4NPD04 Rev 26 EN 40
21. r Care Cleaning Disinfection For cleaning and disinfecting your Lancing Device see the Instructions for Use Caution We suggest cleaning the Meter when visibly dirty Wash your hands thoroughly with soap and warm water after handling the Meter Lancing Device or Test Strips as contact with blood presents an infection risk IMPORTANT INFORMATION Health Related Information DO NOT perform capillary blood glucose testing on critically ill patients Capillary blood glucose levels in critically ill patients with reduced peripheral blood flow may not reflect the true physiological state Reduced peripheral blood flow may result from the following conditions for example e shock e severe hypotension e severe dehydration e hyperglycemia with hyperosmolarity with or without ketosis e Low blood glucose hypoglycemia symptoms may be trembling sweating intense hunger nervousness weakness and trouble speaking e High blood glucose hyperglycemia symptoms may be intense thirst a need to urinate often a dry mouth vomiting and headache If you have any of these symptoms check your blood glucose If your result does not match the way you feel repeat the test If your results still do not match the way you feel call your Doctor or Healthcare Professional 4 Important Information For the most accurate results using TRUEtrack Read all instructions before testing TRUEtrack is an in vitro outside body
22. rical outlet Trying to recharge the battery or power the meter by plugging into an electrical outlet will cause meter to catch on fire or melt Caution Battery is not rechargeable Battery might explode if mishandled or incorrectly replaced Do not dispose of battery in fire Do not disassemble or attempt to recharge battery Dispose according to local country specific regulations Note Replacing battery may affect date and time settings Check date and time by going to Set Up and scrolling through the time date settings by pressing 9 33 Troubleshooting 1 After inserting Test Strip Meter does not turn on Reason Test Strip inserted upside down or backwards Test Strip not fully inserted Test Strip Error Dead or no battery Battery in backwards Meter Error Action Remove Test Strip Re insert correctly Remove Test Strip Re insert Strip fully into Meter Repeat with new Test Strip Replace battery Battery positive side must face up Call for assistance 2 After applying sample test does not start Meter does not beep or begin countdown Reason Sample drop too small Sample applied after two minute shut off Problem with Test Strip Problem with Meter Action Repeat test with new Test Strip and larger drop Repeat test with new Test Strip and apply drop after Meter beeps Repeat with new Test Strip Call for assistance Messages Display TI TI TI uA Eam EE uu m
23. t use Meter Call for assistance Check Test Strip vials for damage Discard any vials that appear cracked or broken 1 Check dates on Test Strip vial being used Do not use if 120 day past written date or date printed next to EXP whichever comes first 2 Wash hands and forearm for alternate site testing Rinse well and dry thoroughly 3 Remove Test Strip from vial Recap vial immediately Note Use Test Strip quickly after removal from vial Test Strips that have been left out of vial too long will give an error message when used Discard old Test Strip and use new Test Strip for testing Ww 4 With Meter off insert Test Strip Contact End Contacts facing up into Test Port Meter turns on Keep Strip Contacte in Meter until testing is Face finished YR N TD d 24 5 Match Code in Display to Code on Test Strip vial being used If Codes do not match see Coding Drop yen appears in Display Lance fingertip or forearm Allow drop to form With Test Strip still in Meter touch edge TRUEtrack of Sample Tip to blood drop and allow blood to be drawn into Strip Remove Test Strip Sample Tip from sample drop immediately after the Meter beeps and starts to countdown on Meter Display P A Caution Holding the Test Strip Sample Tip to the blood sample too long after the Meter begins testing may cause inaccurate results Note If Meter did not beep or begin countdown soon after touching blood drop
24. temperature 36 86 F DO NOT REFRIGERATE OR FREEZE e Do not keep meter in an area where it may be crushed i e back pocket drawer bottom of bag etc Meter Care Cleaning Disinfection To Clean the Meter removing blood or soil Cleaning removes blood and soil disinfecting removes infectious agents We suggest cleaning your Meter when visibly dirty Never put Meter in liquids or allow any liquids to enter the Test Port Wipe Meter with a clean lint free cloth dampened with 7096 Isopropyl alcohol Let Meter air dry thoroughly before using to test Do not use bleach to clean the Meter For assistance contact Customer Care using the phone number on the cover of the Owner s Booklet For Healthcare Professionals please refer to the Quality Assurance Quality Control Manual for instructions on Meter care cleaning and disinfection Instructions for use of the System for more than one person may be found in the Quality Assurance Quality Control Manual The QA QC Manual is available call 1 800 803 6025 or 1 954 677 4599 31 Glucose Control Care e Write date opened on Control label Discard 3 months after opening or after date printed next to EXP whichever comes first e After use wipe bottle tip clean and recap tightly e Store at room temperature 36 86 F DO NOT REFRIGERATE OR FREEZE Test Strip Care e Store Test Strips in original vial only Do not transfer old Test Strips to new vial Write date opene
25. to Sample Tip discard Test Strip Repeat test with new Test Strip and new blood drop If problem persists see Troubleshooting 9 After countdown result is displayed with date and time Remove Test Strip and discard Result is stored in Memory Meter turns off Note When using the meter for the first time check the unit of measure in the meter Display after performing a control or blood test Result must display in the correct unit of measure mg dL If the result does not display in the correct unit of measure DO NOT use the meter and DO NOT use the meter result to determine treatment 10 Record result in log book Note Used Test Strips and lancets are considered biohazardous Dispose used Test Strips and lancets in approved biohazard container PNA 25 System Out of Range Warning Messages CAUTION TRUEtrack measures blood glucose results from 20 600 mg dL If blood glucose result is less than J 20 mg dL Lo appears in Meter L C Display If blood glucose result is greater Li than 600 mg dL Hi appears in FI Meter Display Always repeat test to confirm Low Lo and High Hi results If results still display Lo or Hi call your Doctor or Diabetes Healthcare Professional immediately Note Lo results are included in the Morning Average as 20 mg dL Hi results are included as 600 mg dL 26 Set Up Time Date 1 Start with Meter off Do not insert Test Strip
26. ttery j Dead Battery Cade Code Chip Error WARNING Out of range Hi Result 600 mg dL Out of range Lo Result 20 mg dL 37 Action Turn Meter off and on again If error persists call for assistance About 50 tests can be done before battery must be replaced Replace battery Remove Code Chip and re insert If error persists call for assistance WARNING Retest with new Test Strip If result is still Tabi xe lu contact Doctor immediately System Specifications Result Range 20 600 mg dL Sample Size Minimum 1 microliter 1 uL Sample Human capillary whole blood or TRUEcontrol Glucose Control Solution Test Time 10 seconds Result Value Plasma values Assay Method Electrochemical Reference Method Yellow Springs Instrument YSI Power Supply One 3V lithium battery CR2032 non rechargable Battery Life Approximately 1 100 tests or 1 year Automatic shut off After two minutes of non use Weight 1 66 ounces Size 3 52 x 2 15 x 0 67 Memory Size 365 blood glucose results 1 Control Test result Operating Range Meter amp Test Strips Relative Humidity 10 9096 Non condensing Temperature 50 104 F Hematocrit 30 5596 Note Use within specified environmental conditions only 38 Chemical Composition TRUEtrack Test Strips Glucose Oxidase fe ag sp 2 5 Units Mediators Buffers and Stabilizers TRUEcontrol Glucose Control Contents Volume
Download Pdf Manuals
Related Search
Related Contents
YGE L-series 60HV and 90HV electronic speed controller (ESC Druck DPI 610/615 取扱説明書 - 三菱電機 Blankenhorn - Knapptools Copyright © All rights reserved.
Failed to retrieve file