Home

Meriam M1 Series Digital Manometer Data Sheet PDF

image

Contents

1. M1 Series Digital Manometer Calibrator M1 Series Advantages Engineering Units 8 selectable Inches of H O 20 C mm of H O 20 C mm of Hg 0 C Inches of Hg 0 C kPa mBar Bar PSI and user selectable Media Compatibility Non isolated sensor for clean dry non corrosive gases Pressure Limits DN units 3 x F S on high side only or 200 PSI whichever is less GN or AN units 3 x F S range or 200 PSI whichever is less Accuracy No temperature effect over the entire operating range 14F to 122 F 10C to 50 C Min Max M101 only Displays the MIN and MAX pressures absolute pressure versions Applications M1 Series Digital Manometer Calibrator The M1 Series of handheld manometers from Meriam Process Technologies meriam A SCOTT FETZER COMPANY combines form fit and function to deliver precision pressure measurement for field plant or lab use For reference indication and shirt pocket convenience select the low cost M100 Digital Manometer with its 0 25 FS accuracy Or specify the M101 Calibrator when better accuracy is needed for more exacting measurements The M101 delivers 0 10 FS accuracy and additional features normally found on higher priced instruments Both models are available in differential gauge and Leak testing for low pressure gas systems e Pressure drop monitoring across filters e Monitoring vacuum on condensers or pumps e Verific
2. 3 16 Hose Barb to 1 8 MNPT PN A34142 2 GN0030 EA Gauge 6 Adapter 1 8 O D Tube to 1 8 MNPT PN A34012 GN0050 0 to 50 00 PSI Gauge A34477 Basic Test Kit Includes GN0100 0 to 100 0 PSI Gauge Nylon Tubing 10 FT PN A34103 2 Adapter Brass Tubing to 1 8 MNPT PN A34102 AN0775 el AN1551 0 to 1551 mm Hg Absolute 9A000053 ABS plastic carrying case AN2585 0 to 2585 mm Hg Absolute 9P000058 Spare Protective Boot Red each M1 comes standard with a protective boot Z1055 NIST Traceable Certificate with Data NCAT105 Meriam Process Technologies 10920 Madison Ave Cleveland OH 44102 TEL 216 281 1100 FAX 216 281 0228 EMAIL sales meriam com www meriam com
3. ation of CPAP or BIPAP systems for home or hospital settings Hold M101 only Freezes the pressure measurement on the display however the bar graph is still active Ave M101 only Displays a continuous filtered average of the pressure measurements Temp Displays the internal ambient temperature of the M1 in C or F Record Mode The M1 can store up to 240 pressure measurements e Automatic the current value is automatically stored every 5 seconds for up to 20 minutes e Manual the current value is stored every time the Units key is pressed up to 240 times Meriam Process Technologies 10920 Madison Ave Backlight A green backlight is user activated via the backlight key Ared backlight is automatically activated during an error over range condition Auto Shutoff To conserve battery life the M1 will automatically power off after 20 minutes of keypad inactivity Field Recalibration M1 can be calibrated in the field for zero and span Low Battery Indication BAT icon is displayed when batteries require replacement Approximately 2 hours of run time is provided on a low battery condition Bar Graph Horizontal bar for full scale pressure reference 0 100 Cleveland OH 44102 M1 SERIES Digital Manometer Calibrator Technical Specifications Base Unit e Lightweight and ergonomic e 12 ounces and 6 0 x 3 0 x 1 0 with ESD e Dissipative polycarbonate Keypad Sealed memb
4. rane type with 4 dome style contact buttons e Temperature Specifications e Storage 40 F to 140 F 40 C to 60 C e Operating 14 F to 122 F 10 C to 50 C Ay meriam A SCOTT FETZER COMPANY Connections 1 8 female NPT 316 S S All models have a P1 and P2 port GN and AN units have a sintered metal disc installed on P2 NIST Traceable Accuracy e M100 Digital Manometer 0 25 F S e M101 Calibrator 0 10 F S Certifications e CE Mark comes standard with product e NIST Traceable Certificate with Data optional a i jal m Digit eter Power oe a a a e 3 AA batteries providing over 300 hours of continuous Temperature Specifications use e Storage 40 F to 140 F 40 C to 60 C e Operating 14 F to 122 F 10 C to 50 C Ordering Information Type Range DIGIA Model No amp Description DN0028 0 to 28 00 H20 Differential M100 specify pressure range Digital Manometer DN0138 0 to 138 0 H20 Differential M101 specify pressure range Calibrator DNO416 0 to 416 0 H20 Differential All models include the protective red rubber boot 4 AA batteries and hard copy of the user s manual DN0832 0 to 832 0 H20 Differential Optional Accessories DN2000 0 to 2000 H20 Differential GN0005 0 to 5 000 PSI Gauge A34386 Calibration Kit Includes 3 Nylon tubing 6 ft PN A34103 3 GNO0015 0 to 15 00 PSI Gauge 2 Tee Brass 1 8 O D Tubing PN A34112 1 Adapter

Download Pdf Manuals

image

Related Search

Related Contents

Impex MWM-981 Owner's Manual  WL400 Quick Start Guide  MANUEL D`UTILISATION TRONÇONNEUSE CS-4400  Lenovo B40-80  Sonicare Airfloss  ASUS N Series User's Manual  User manual - Whaley Food Service  User Manual  Notice d`instruction  Corsair 4 GB Registered DDR DIMM ECC PC2700 (333 MHz)  

Copyright © All rights reserved.
Failed to retrieve file